INSTALLATION AND OPERATING INSTRUCTIONS

Similar documents
INSTALLATION AND OPERATING INSTRUCTIONS Page 1

INSTALLATION AND OPERATING INSTRUCTIONS

Control Series Operation Instructions Page 1. "Digi VII"

INSTALLATION AND OPERATING INSTRUCTIONS

Owner s Manual for the Passport Series Rooms PS 44 With SaunaLogic Control

Hallmark Rooms HM 55C and HM 66C Owner s Manual with SaunaLogic Control and Bluetooth Sound System

Owner s Manual for the Passport Series Rooms PS 46 and PS 57 With Saunalogic Control

Infrared Room Installation & Operation Instructions

Infrared sauna SUN S Pure Infra User Manual

*WARNING HAMEREC INSTALLATION AND SERVICE INSTRUCTIONS

S-Series 3 Person Infrared Sauna Touch Pad and Bluetooth IG-870-SH/S870 User Manual

S-Series 3 Person Infrared Sauna Touch Pad and Bluetooth IG-830-SH/S830 User Manual

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-530 BH

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-670EX/E300-CX

NEOSAUNA SERENITY SAUNA INSTRUCTION MANUAL Read all instructions carefully before using this wooden sauna room SKUS: SAU-SER-4C-B, SAU-SER-4C-C

S-Series 3 Person Infrared Sauna IG-870-SH/S870 User Manual

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI80

InfraSauna Custom Cut Installation Guide

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI 40 CE

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI10

INFRARED SAUNA ROOM. Thank You for purchasing Our American Made Product! Proudly Made in the USA! PRECISION THERAPY 4 PERSON SAUNA USER MANUAL

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-540BX/B400-X. Important: Please record your serial number here

ARLEY STEAM SHOWER ENCLOSURE

LEVENS STEAM SHOWER ENCLOSURE

Steamist Sauna Heaters

FREWIN STEAM SHOWER ENCLOSURE

OWNER S MANUAL ONE-PERSON & TWO-PERSON SAUNAS WITH CERAMIC OR CARBON HEATERS

SYSTEM BASIC WHIRLPOOLS

MrSauna Heater SUSSMAN TABLE OF CONTENTS. Installation and Operating Instructions GROUP. Floor Mounted Models: SA-10 SA-14 SA-12 SA-16

OWNER S MANUAL THREE-PERSON & FOUR-PERSON CORNER SAUNAS

OWNER S MANUAL FOUR-PERSON & SIX-PERSON SAUNAS

ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

TRANQUILITY ADVANCED HEATING SYSTEM

Installation Manual 2 PERSON STANDARD SAUNA 200S

SK SERIES INSTALLATION INSTRUCTIONS 1

ECO SPA & POOL OWNERS MANUAL & INSTALLATION GUIDE

SK45, SK60, SK80 SK45-3, SK60-3, SK80-3

infrared essential lounge owner s manual

Whirlpool Bathtub Model Number: MT618

OWNER S MANUAL 1-2 PERSON SAUNA

UNIVERSAL TEE STYLE Hydromassage Bath Heater INSTALLATION INSTRUCTIONS

4230/6230/9230 SERIES OWNERS OPERATION GUIDE

Owner s Manual. Model PH050006

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

ULT L IMAT A E SERIES SOLID-STA T T A E SYSTEM OPERAT A ION MANUAL 8600

Spa Control System OWNER S MANUAL

OWNER S MANUAL 1-2 PERSON SAUNA

INSTALLATION/OPERATING INSTRUCTIONS. AQUEFIER POOL HEATERS Model TK125T

Oceanic Sauna Heater Manual

ELECTRIC FLAT PANEL FIREPLACE HEATER

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

INSTALLATION, OPERATION AND MAINTENANCE

IMPORTANT INSTALLATION and OPERATING INSTRUCTIONS

OWNER S MANUAL FOUR-PERSON & SIX-PERSON SAUNAS

OWNER S MANUAL Serenity Half Sauna

Bubble Massage Bath (Include Electronic Drain)

POOL HEATER INSTALLATION, OPERATION AND MAINTENANCE

OWNER S MANUAL CORNER SAUNAS SA1312/SA1320/SA2412DX/SA2420DX. Rev. 5/16, Ver. 5

6500/7500 SERIES OWNERS OPERATION GUIDE

Sauna Craft CTT Heater Installation Manual

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

INFRARED SAUNA OWNER S MANUAL

Installation Manual. Model: SAUNAS-250P

Wall Mount Electric Fireplace

E2 Series Installation

Important Installation Guide & Operating Instruction

AT and 3T STEAMBATH GENERATORS For Models 4kW thru 14kW With T100 Control (Includes Optional Warm Start)

Gallery Electric Fireplaces

mr.steam Lexington Collection Feel Good Inc. REFER TO INSTALLATION, MAINTENANCE MANUAL PROVIDED WITH PRODUCT FOR COMPLETE INSTRUCTIONS

Model. Serial No. Installation, Operation and Maintenance Manual. Lexington Collection ELECTRIC TOWEL WARMERS. mr.steam. Feel Good Inc.

OWNERS OPERATION GUIDE

IMPORTANT INSTRUCTIONS READ & SAVE

ELECTRIC FIREPLACE WITH MANTEL MODEL WS-Q-03 OWNERS MANUAL

Dear Customer, The whole TheraSauna team is looking forward to serving your needs.

Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W

SYSTEM INSTALLATION AND SERVICE AT AND 3T STEAMERS

ELECTRIC FLAT PANEL FIREPLACE HEATER

WALL MOUNTED ELECTRIC FIREPLACE HEATER. Model # : Onyx Ivory Mirror OWNER S MANUAL. AC V 60Hz 1500W

NO VENTING REQUIRED 120V AC;

FLCH4R Garage and Utility Electric Heater

OWNER S MANUAL. Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER. Model Number: EFW-XB60B WARNING CAUTION

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

Hardwired Model Shown. Installation & Operation Manual for WarmlyYours Infinity Towel Warmers

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

2004 Owner s Manual. USA and Canada. S-100 S-200 S-600 S-700 S-300 Infrared S-400 Infrared S-500 Extreme S-800 Extreme

Wall Hanging Mode. Pedestal Mode

Index. Welcome

Installation and Operation Manual MG-304. Please read this manual carefully before use.

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

Personal Hydro-Massage System: 10-Jet Tower Model. Owner s Manual AB Kohler Co.

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

USER MANUAL

INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPSCLCMCQRL Merchandising Hot Cabinets

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Owner s/operator s Manual

Alice. In Wall Recessed Electric Fireplace Model Number: (EF172B, EF173B, EF174B, EF175B, EF176B) OWNER S MANUAL

AWP 3260 CWH Installation Instructions Hydro-massage Bathtub - UL 1795

IMPORTANT INSTRUCTIONS READ & SAVE

Transcription:

SECTION 1: GENERAL INFORMATION SaunaLogic Control Control Box CB PK-1 "Viki" Heater Sauna Series Models 4.5, 6.0, 8.0 (1720-45-02, 1720-60-02, 1720-80- 02) with "SaunaLogic" Control Read all instructions carefully before installation. Please leave all instructions and warranty with the owner. Prolonged exposure to elevated temperatures is capable of inducing hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches several degrees above the normal body temperature of 98.6 F. The symptoms of hyperthermia include an increase in the normal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of the hyperthermia include failure to perceive heat, failure to recognize the need to exit the room, unawareness of impending hazard, fetal damage in pregnant women, physical inability to exit the room and unconsciousness. The use of alcohol, drugs, or medication is capable of greatly increasing the risk of fatal hyperthermia. These heaters are ETL approved for permanent installations and electrical connections. Built with splash proof construction, the conducting parts are protected against water. All wiring must be performed in accordance with national and local codes. See Diagram 2 for wire and room size requirements. These heaters are wall mounted. Do not take a sauna if using alcohol, drugs or medications. Pregnant women or persons with poor health should consult their physician before using any sauna. Caution fire hazard: Do not use the sauna room for drying clothes, bathing suits, etc. Do not hang towels above heater or place any object other than the rocks supplied on the heater. If any darkening of the wall around the heater is noticed discontinue sauna use immediately. Inspect sauna regularly for required maintenance to heater, control and benches. Replace wood surfaces which show any signs of deterioration. The heater gets extremely hot during operation and should not be touched or burns may result. Minors should be adequately supervised

Page 2 DIAGRAM 1 MOUNTING BRACKET LOCATION AND MINIMUM DISTANCE TO COMBUSTIBLE MATERIAL K CB PK-1 Temperature 6 1/4" 13 3/4" 18" min 2" 15 3/8" B 6½" Min. A Screws Use the long screws in the upper holes of the mounting bracket D 2" 6½" Min. 2" Guard Rail C (Upper Bench) 1" 18" min 46 3/4" Minimum 20 1/4" CB PK-1 10" max 73 1/2" Minimum Recheck your distances from the heater to combustible materials to be sure you have the proper minimum distances. OBSERVING MINIMUM DISTANCES IS REQUIRED TO REDUCE FIRE HAZARD MINIMUM "A" "B" "C" "D" "K" HEATER DISTANCE DISTANCE DISTANCE DISTANCE DISTANCE Viki 4.5 3" 4" 4" 12 1/4" 26 1/2" Viki 6.0 4" 5" 5" 12 1/4" 26 1/2" Viki 8.0 5" 6" 6" 12 1/4" 26 1/2" DIAGRAM 2 HEATER MODEL / Product Number Viki 4.5 1720-45-02 Viki 6.0 1720-60-02 Viki 8.0 1720-80-02 KW 4.5 6 Floor Area MINIMUM ROOM Ceiling Height 12 sq. ft. 73 1/2" 21 sq. ft. 73 1/2" 8 31 sq. ft. 73 1/2" Volume Cu.Ft. MAXIMUM ROOM Ceiling Volume Height Cu.Ft. 100 96" 210 175 250 96" 96" 310 425 PHASE Power Supply to CB PK-1 WIRE SIZE CB PK-1 to Heater VAC AMPS 1 208 21.6 2 # 10AWG+ GR 2 # 10AWG+ GR 1 240 18.8 2 # 10AWG+ GR 2 # 10AWG+ GR 3 208 12.5 3 # 12AWG+ GR 3 # 12AWG+ GR 3 240 10.8 3 # 12AWG+ GR 3 # 12AWG+ GR 1 208 28.8 2 # 8AWG+ GR 2 # 8AWG+ GR 1 240 25 2 # 10AWG+ GR 2 # 10AWG+ GR 3 208 16.7 3 # 12AWG+ GR 3 # 12AWG+ GR 3 240 14.4 3 # 12AWG+ GR 3 # 12AWG+ GR 1 208 38.5 2 # 8AWG+ GR 2 # 8AWG+ GR 1 240 33.3 2 # 8AWG+ GR 2 # 8AWG+ GR 3 208 22.2 3 # 10AWG+ GR 3 # 10AWG+ GR 3 240 19.2 3 # 10AWG+ GR 3 # 10AWG+ GR

Page 3 SECTION 2: MOUNTING OF SAUNA HEATER AND PK-1 HANGING THE HEATER Using the template provided, drill four 9/64" holes to fasten the heater to the wall. Install two of the four 1/4" x 1 1/8" hex head lag screws (supplied with the heater) into the upper two holes. Tighten these screws until their heads are about 1/8" from the wall surface. The screws must be threaded through the wall into a framing member or backing board to support the heater weight. Hang the heater on the two upper screws. Locate the other two ¼" x 1 1/8" hex head lag screws (supplied with the heater); install them into the two lower mounting holes. Tighten to lock the heater in place. See Diagram 1 for the heater location details and the necessary clearances to combustible materials. Remove the cover of the PK CB-1 Control Box to gain access to the 4 mounting holes in the back of the box. The control box can be mounting inside the sauna room on a wall according to Diagram 3. Or it can be mounted outside the sauna room. Locate the 4 screws 3/16 x 3/4"supplied into the 4 mounting holes. (See Diagram 3) SECTION 3: PLACING OF ROCKS (SEE DIAGRAM #10) The rocks supplied with the heater have been chosen to provide the best heater performance. Use of any other type of rock may void the heaters warranty. Never operate the heater without rocks in place! Rinse the rocks with water before placing in the heater. Carefully place the rocks loosely so that the air can circulate through the heater. Packing the rocks too tightly may cause the heater high limit switch to trip. The rocks must fully cover the heating elements. Attach the guard with the screws provided. SECTION 4: ELECTRICAL HOOK-UP Electrical installation must be made by a licensed electrician in accordance with the National Electrical Code and local regulations. Remove the screws from the CB PK-1 control box to access the electrical connections. Route the wires through the holes provided on the bottom of the control box and connect the wires to the terminal block. To determine the correct wire size, refer to Diagram 2. Use copper supply wire only, suitable for minimum 90 degrees C. The heater must be grounded! See Diagram 6 for proper connections. SECTION 5: TEMPERATURE SENSOR Feed the 17 ft "low voltage" sensor wire from the sensor location to the control box (CB PK-1) location. Sensor wire must be routed completely separate (as per low voltage electrical wiring codes) from any wiring carrying over 50 volts. It may be necessary to drill holes to string the wire through the studs or ceiling joists. Using a flat tip screwdriver, unsnap sensor cover from sensor. Mount sensor to a finished wall directly above heater and two (2) inches down from ceiling using two (2) screws (provided) as shown in Diagrams 1, 3 & 5. Connect wires into CB PK-1 on the 3 pin plug labeled "JT2" of the circuit board. Fire sprinkler systems used inside any sauna room should be properly rated for sauna room temperatures. Do not pour chlorinated pool or spa water on heater. Excessive water use on heater may cause damage and void warranty. Do not install a shower in the sauna room. Electric Shock Hazard - High voltage exists within this equipment. There are no user serviceable parts in this equipment. All installation and service to this equipment should be performed by qualified licensed personnel in accordance with local and national codes. Do not construct sauna room so as to restrict air flow through the bottom of the heater. Packing the rocks too tightly may cause the heater high limit switch to trip.

Page 4 DIAGRAM 3 Sensor protective cover. Locate top of sensor 2" from ceiling and directly above of heater. SaunaLogic Control Box (CB PK-1) can be outside of the sauna room or installed inside sauna room. If inside sauna room see diagram below for spacing requirements. Minimum ceiling spacing. tongue and groove 2x4 supports CB PK-1 Control Box Minimum spacing. Maximum spacing. Power Input 7' SJTW Wire provided with heater 15' Low Voltage wire provided with control. DIAGRAM 4 DIAGRAM 5 SaunaLogic Control Back of sensor Insert screwdriver tip here to unsnap sensor cover from sensor. Note vertical orientation of

Page 5 SECTION 6: HEATER SCREEN (GUARD RAIL) Install a wooden heater guard to prevent the sauna bather from accidentally touching the sauna heater. Install the heater guard rail with the dimensions shown in Diagram 8. SECTION 7: SAUNALOGIC CONTROL INSTALLATION & OPERATION INSTALLATION ROUGH IN The SaunaLogic control must be mounted outside the sauna room in a dry environment. To mount the control cut an 1" hole in the wall behind control location. Route the control wire from CB PK-1 to the control. Note: Use the factory supplied cable only! Do not staple through or otherwise damage the cable! Connect the control cable to the SaunaLogic and secure the control to the wall by 2 mounting screws provided. Connect the other end of the control cable through the electrical access hole on the bottom of the control box and connect it to "JT1". OPERATION When power is connected to the heater, the room temperature setting is automatically preset to 176 F and the bath time is set to 60 minutes. These settings are adjustable (as described below) from 125 to 194 and from 0 to 60 minutes and any changes are remembered by the heater for your next bath. Should the heaters power be lost then restored, the settings will return to their default values. With the power to the heater turned on, press the control ON/OFF button once. The room temperature will be displayed on the control. The heater will turn on and begin heating the room. Once the selected bath temperature is reached, the heater will turn heater on and off again as needed to maintain the desired temperature. At the end of the selected time, the control will turn itself off and the control display will turn off. SETTING THE TIME AND TEMPERATURE To set the time, press the control ON/OFF button to turn on the heater. Press the TIME "+" or "-" buttons on the control to increase or decrease time for desired setting. The maximum of time is 60 minutes. Do not locate benches over heater. Refer to Diagram 1 for minimum clearance of ceiling above heater. Minimum clearance from heater to wooden surfaces (benches, side walls, heater fence etc. refer to Diagram 1). Mounting brackets supplied. Provides proper clearance from wall behind heater. Use only copper wire of the size and type indicated in the Heater Specification Chart and the temperature rating indicated on the heater junction box. All heaters and controls must be grounded per NEC to prevent electrical shock in case of unit failure. Electrical outlets or receptacle must not be installed in a sauna room. A guardrail or fence is required around the heater to prevent burns from accidental contact. To set the temperature, press the control ON/OFF button to turn on the heater. Press the TEMP "+" or "-" buttons on the control to increase or decrease temperature for desired setting. The maximum temperature is 194 F (90 C).

Page 6 TO PROGRAM A DELAY START Turn your control on by pressing the power button, in the center of the control pad. Press the "set" button, directly to the left of the time display window until your display shows a flashing semi-colon in between the 4 digits. Example: 00:45. Use your +/- keys to adjust the time to the desired amount of delay before the sauna starts. Example: to program an 8 hour and 30 minute delay you would have display like this: 08:30. At this point you may simply walk away, (do not turn the control off). The control will time down for the programmed amount of delay and then start on it's own. Note: Always remember that if you have the flashing semi-colon in your time display, you are in the delay start mode. Use the "set" button to toggle between delay and instant start. Shower Sauna (10-15 min.) SECTION 8: LIGHT INSTALLATION The Saunalogic control is ONLY capable of operating the Spectr-Light kit. Spectra-Light kits are available as an accessory and come with 3 internal color therapy, 2 interior white and 3 exterior white lights. These lights are connected directly to the CB PK 1 contactor box using wiring harnesses supplied with the Spectra-Light kit. Once installed the Saunalogic control has three buttons built in to control the three various light circuits. Special wiring harness extensions are available to make minor changes to bulb placement. Note: Any other lighting options or packages that are used will require a separate switching device and additional light distribution and power circuits to be run. Shower or swim Rest (10-15 min.) SECTION 9: HIGH LIMIT CONTROL (RESET BUTTON) The sauna heater has a built-in high limit control, which automatically turns off the heater if the temperature inside the sauna room rises to an abnormally high level. The Saunalogic control will display "HL" if the high limit control has shut the heater off. To restart the heater, let the heater cool, then push the "On/Off" button on the control panel. If the high limit continually shuts off the heater, contact a service representative at 1-800-780-4427 for additional support. Relax with juice or water You liked it? Do it once again and you will feel great.

Page 7 SECTION 10: HOW TO TAKE A SAUNA ~ When taking a sauna, allow time to relax completely. ~ Remove clothing and jewelry...if required, wear a towel loosely. ~ After 10 minutes or when perspiration begins, leave sauna and relax in dressing area...follow with a cool shower. ~ Cooling time should equal time spent in sauna. Enter sauna room again and stay 5 or 10 minutes. ~ Repeat the cycle 2 or 3 times; end with a brisk shower...rinse in cool water. ~ Dress when completely dry and perspiration has stopped. ~ Some sauna bathers enjoy the soothing effect of steam by splashing water on the heated sauna rocks. Use only one dipper full (approximate ½ cup) at a time and keep clear of the steam as it rises off the rocks. ~ Do not smoke, exercise or drink alcoholic beverages in the sauna room. ~ Do not pour chlorinated pool or spa water on the heater or corrosion damage may result. The "CAUTION" and "" placards must be mounted in accordance with Section 10. SECTION 11: PLACARDS Two metal placards are included in the Installation Instruction Envelope packaged with every Sauna Heater. The CAUTION placard must be attached to the interior wall of the sauna room directly above the heater where it is visible to the bather. The placard must be attached to the door of the sauna room. SECTION 12: ROOM CONSTRUCTION For safety and reliability, the following rules must be addressed. ~ No permanent locking or latch system is to be used on the sauna door. ~ Acceptable door fittings are: magnetic catches, friction catches, spring or gravity loaded closures. The door must always open outwards. ~ No shower may be installed in a sauna room. ~ No electrical receptacle shall be installed in a sauna room. ~ The enclosed : Reduce the risk of overheating...warning plate must be mounted on the interior wall above the heater. ~ The enclosed CAUTION: Reduce the risk of fire...caution plate must be mounted on the interior wall above the heater. ~ The heater should not be operated without its container properly filled with rocks and the rock guard in place. ~ If an intercom speaker is installed, it should be away from the heater and as close to the floor as possible. ~ Fire sprinkler systems installed inside any sauna room should be properly rated for sauna room temperatures. ~ Always mount the heater according to these installation instructions. For safety purpose sauna door must open out and not lock. Never use a wood stain, seal or preservative on the inside of your sauna room. Light fixtures get very hot during operation. Locate light fixture where it will not be a burn hazard.

Page 8 DIAGRAM 6 WIRING DIAGRAM: CONTROL AND HEATER MODELS Viki 4.5, 6.0 & 8.0 (1720-45-02,1720-60-02,1720-80-02) SaunaLogic and CB PK-1 Back Element Middle Element Front Element 1 2 GND T1 T2 Viki Heater 1720-45-02 1720-60-02 1720-80-02 GND T1 T2 K2 K4 K1 K6 K3 K5 Transformer GND L1 L2 CB PK-1 Box 240V 1phase POWER INPUT Interior Lights Temp. Sensor SaunaLogic Control High Limit Exterior Lights Color Therapy Lights

Page 9 DIAGRAM 7 TYPICAL PRE-CUT WALL CONSTRUCTION 2x4" framing 1/2" wallboard DIAGRAM 8 HEATER SCREEN (GUARD RAIL) min 2" fiberglass insulation foil vapor barrier T&G soft wood 1/2" wallboard min 1" min 2" Heater screen DIAGRAM 9 VENTILATION High Limit Sensor DIAGRAM 10 a. Loosely place rocks between the elements so air flow is not restricted. c. Loosely place rock 2 to 3" deep over the element tops. Incorrect Placement of Rocks Wall Bracket Rock Bottom Should have rocks between the front element and the outer wall of the heater. b. Rocks must be placed between the elements and the wall of the rock compartment. Locate vent under the top bench 1. Put smaller rocks in first around the outer perimeter of the rock compartment. 2. Completely fill all four sections (front, 2 center sections between elements, and back). 3. In the outer sections, use smaller rocks placed more tightly (see note b). 4. Place rocks loosely in the center 2 sections (see note a). 5. Be sure rocks completely cover the elements (see note c). 6. Loosely cover the tops of all elements with rocks a minimum of 2 to 3.

Page 10 SECTION 13: VENTILATION In a private sauna, the air should be changed about 6 times an hour. This can be achieved by making a vent opening (fresh air inlet) in the sauna wall below the heater. The air outlet must be lower than the upper benches, as far as possible from the heater and about two feet higher than the fresh air inlet vent, See Diagram 9. It is recommended that ventilation openings meet the requirements of UL Specification 875. The minimum opening should be determined using one of the following formulas: For R<31, V>9.3, For R>31, V>0.3R where R=the floor area of the room in square feet and V=the minimum vent size in square inches. SECTION 14: MAINTENANCE The sauna, like a bathroom, should be kept clean and odor free. Towels or mats should always be used on benches and floor as perspiration otherwise penetrates the soft wood. Air out the sauna often by keeping the door and vents open when the sauna is not in use. Saunas that are in daily use should be washed down at least once a week to keep them clean and the air fresh. Duckboard should be removed from the sauna, the sauna floor mopped and dried in a conventional manner, and the duckboard thoroughly scrubbed and dried before returning to the sauna room. The sauna heater should be wiped down occasionally with a damp cloth to remove lint and dust. The rocks should be removed once a year for cleaning and small or crumbled rocks replaced. To clean and remove perspiration stains, use soap or detergent in warm water, best applied with a scrub brush. Badly soiled surfaces may require sanding. Sand paper wrapped around a wooden block works well. Benches and supporting structure must be inspected annually for potential deterioration due to age, dry rot or abuse. Any boards with signs of deterioration should be replaced immediately to avoid possible injury. SECTION 15: TROUBLESHOOTING If control displays "SN" it means no sensor is connected. Refer to Section 5 for sensor installation information. If control displays "HL" it means the high limit is open and the heater is too warm. Refer to Section 9 for high limit information. For troubleshooting or service questions call 1-888-780-4427 and ask to speak with service. Prior to calling, please have the Model and Type number available. You may also email us at techsupport@saunatec.com