SEQUENTIAL CIRCULATOR

Similar documents
SEQUENTIAL CIRCULATOR

SEQUENTIAL CIRCULATOR MODEL 3008

SEQUENTIAL CIRCULATOR MODEL 3008

Multi-Flo Model #1545-KT. Multi-Flo Model #1545-F

Bio Compression s SC-3004-DL

SC-3008-DL SEQUENTIAL CIRCULATOR

Instructions For Use SC-2004-OC, SC-2004FC-OC and SC-2008-OC. Sequential Circulators

Model IC-1545-DL Multi-Flo DVT Combo

Compression therapy device & accessories Model 701A User manual

TributeNightTM. user guide

DELUXE ALTERNATING PRESSURE SYSTEM USER GUIDE

MODEL 7000 SUCTION UNIT

Dyna-Form Air. Alternating Pressure Relief Overlay System

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

AIR EXPRESS LAL. P1500 LOW AIR LOSS THERAPY SYSTEM REF C1500 Control Unit REF M1500 Mattress. Operator s Manual P/N /03

16 OUTDOOR MISTING FAN

With Remote Control. English

MaxiCompressor. Limited Warranty. High Performance 50 PSI Compressor 501-S

CircuFlow Quick Setup Guide

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

User Manual standard for Medical Electrical. Control Number 95CG. Classified by. Underwriter s Laboratory Inc. for UL

16 Stand Fan with Remote Control Model No: FS3-40R-30

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

Food Slicer Visit our website at:

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0040A

Reliability in Laboratory Centrifuges Since Operator s Manual. Models 614B, 614L, 614U/UL and 614V/VL Laboratory Centrifuge. Rev. 5.

SAVE THESE INSTRUCTIONS

18 INCHES, OSCILLATING STAND FAN

Service Centers: Conair Consumer Products Inc. 156 Parkshore Drive. Brampton, Ontario L6T 5M1

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

INSTRUCTIONS FOR OPERATION AND CARE OF

The FAWSsit USER CARE GUIDE

Anti-Decubitus Air Alternating Pressure Mattress System Operation Manual

CLEAN MIST SMART HUMIDIFIER Instruction Manual and Warranty Information IM0031B READ AND SAVE THESE INSTRUCTIONS

Stand Fan. English. Owner s Guide. Model F R

HR1-08R-21 Reflective Heater Operating Instructions. Model No. HR1-08R Soleus Air International

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

Med-Aire 8 Alternating Pressure Mattress Replacement System With Low Air Loss OPERATOR S MANUAL

INSTRUCTIONS FOR OPERATION AND CARE OF

Instruction Manual Item No.: V~, 60Hz

Antari Low Fog Machine

I N ST R UC T I ON MODEL 2612 & 2712 SLICERS MODELS 2612 ML ML FORM (12-98) 2612 SLICER

Natural Mist Humidifier. Vicks. (Model V3500) IMPORTANT! READ AND SAVE THESE INSTRUCTIONS. Use and Care Manual

With Remote Control. English. Model

INSTALLATION AND OPERATION MANUAL

USER INSTRUCTION MANUAL SAPPHIRE SERIES 800

10 Table/Wall Mount Fan Model No: FTY-25 Operating Instructions FTY Soleus Air International

IMPORTANT SAFETY INFORMATION

User s Manual. Alternating Air Mattress Model No.: MA-6100

100 Series Maxi Internal Filters

WA A Aqua Sub Bottom-load Water Cooler

SERVICE PROCEDURES. Mattress 2 Pipe Overlay or Replacement

CLEAN MIST SMART HUMIDIFIER Instruction Manual and Warranty Information IM0002E READ AND SAVE THESE INSTRUCTIONS

AMBIENCE Low Air Loss Mattress Replacement System

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

Instruction Manual Item No.: V~, 60Hz

Med-Aire Assure 5 Air + 3 Foam Base Alternating Pressure and Low Air Loss Mattress System

INSTRUCTION MANUAL. Instruction Manual High Throughput Homogenizer

IMPORTANT SAFETY INFORMATION

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

PARTS AND SERVICE MANUAL FOR. DIMPLEX PURIFIRE ELECTRIC STOVE Model TDS8515

557X-558X Comfort Care & Cozy Comfort, Premier Recliner 567X-5680 XL Cozy Comfort & XL Cozy Comfort Swing-Arm, Premier Recliner

IMPORTANT SAFETY INFORMATION

CLEAN MIST DUAL TANK SMART HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

Digital Fabric Steam Press

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY

IMPORTANT SAFEGUARDS Danger! Danger of burns!! Important!

MODEL SF-420. Fabric Steamer. by Top Innovations, Inc. Please read all instructions before use. Mail in your warranty registration card.

MS-11 Flat Panel Reflective Heater Operating Instructions. Model No. MS Soleus Air International

The CENTURY. High Performance Oscillating Fan OWNER S GUIDE FOR MODELS 9002X & 9702X

User Instruction Manual

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

PRELUDE. User Manual. PA3500 Mattress Overlay System. Guarantees and Warranty. 1.1 General Information 1.2 Intended Use. 3.1 Unpacking 3.

OWNER S MANUAL COOL MOISTURE HUMIDIFIER 1.25 GALLON (4.7 LITERS) OUTPUT PER DAY* RCM-832N. *Output dependent on room temperature and humidity.

BL Series INSTRUCTIONS

ISTRUZIONI PER L USO. Climatizzatore CT300 - CT300H

Feel Perfect Heated Throw with SleepPerfect Technology Instruction Booklet Please read these instructions carefully and retain for future reference.

OGCF2002A User Manual

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

MaxiCompressor. evo. High Performance 50 PSI Compressor TH PLACE ADEL, IOWA 50003

English 1 AIR ALTERNATING PRESSURE MATTRESS REPLACEMENT SYSTEM

Sealed Electric Wall & Floor Mounted Towel Warmers. heatingthroughinnovation. Installation, Operating, Maintenance and After Sales Manual.

MP BB. ElEcTrIc FIrEplAcE HEATEr. INSTrUcTION MANUAl ATTENTION:

Nilfisk Inc Winnetka Avenue North Minneapolis, MN REV.03( ) VF80189

6.6L Stainless Steel Urn. User Manual

Service Manual. Model Number: Compact Fireplace DF203A DF2006. UL Part Number to 800

Cavitator Ultrasonic Cleaner Instruction Manual

Convertible Powered/ Non-Powered Dynamic Mattress System. Operation Manual. Distributed by:

USER MANUAL SAVE THESE INSTRUCTIONS


ULTRASONIC HUMIDIFIER With Night Light and Fragrance Diffuser

Piccolo Cyclonic Vacuum Cleaner

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Ultrasonic Humidifier

CLEAN MIST DUAL TANK SMART HUMIDIFIER. Instruction Manual and Warranty Information TABLETOP & FLOOR STANDING WITH REMOTE CONTROL

HM & HM Ultra Thin Micathermic Heater. Model No. HM / HM Soleus Air International

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Instructions for Installation and Use

MANUAL VERSION SERIAL # X-1 MINI PRO OWNER S MANUAL ASSEMBLY & OPERATOR INSTRUCTIONS 1.0

Transcription:

SEQUENTIAL CIRCULATOR MODEL 2008 BIO COMPRESSION SYSTEMS, INC. Phone: 201-939-0716 / Toll-Free Phone: 800-888-0908 Fax: 201-939-4503 E-mail: biosystems@biocompression.com www.biocompression.com U.S. BASED MANUFACTURER 1

Congratulations on the purchasing of your BIO COMPRESSION SYSTEMS MODEL # SC-2008 Sequential 8 Circulator System The durable, high quality material used in the manufacturing of this product will ensure you long lasting performance. On rare incidences when problems occur, you can feel confident that your pump and garment are backed by the best warranty and customer service in the industry! By simply dialing our toll free number for customer service 800-888-0908 warranty repairs or adjustments will be performed in a timely manner with minimal inconvenience to you Should a warranty repair require an extended length of time, if available, a pump from our loaner inventory will be made available to you, so as to prevent any interruption in your treatment schedule. 2

The Model # SC-2008 Sequential Circulator is a manual (not software driven) 8 chamber sequential, pneumatic compression device intended for either primary or adjunctive treatment of primary or secondary lymphedema. The device is also intended for additional or alternate treatment of venous insufficiency and venous stasis ulcers associated with venous insufficiency as well as general treatment for swelling of the extremities. The device is intended for both home and hospital use. CAUTIONS AND PRECAUTIONS CAUTION: Federal law restricts this device to sale by, or on the order of, a licensed physician. CAUTION: High pressure should be set with caution on patients with peripheral arterial occlusive disease. CAUTION: To prevent the potential for reverse pressure and retrograde flow, do not adjust the gradient pressures without physical supervision. CAUTION: If you experience pain or unusual symptoms during use, discontinue treatment and consult your physician immediately. CAUTION: In the event of a power failure, simply unplug the garment from the pump to release any residual pressure in the garment. CAUTION: The system is not intended for use during sleep. SYMBOL DEFINITIONS = REFER TO DOCUMENTATION BEFORE USING AND SERVICING = TYPE B APPLIED PART = CLASS II PROTECTION 3

CONTRAINDICATIONS Infections in the limb, including cellulitis without a minimum of 72 hours of appropriate antibiotic coverage The presence of lymphangiosarcoma Deep Vein Thrombosis Inflammatory phlebitis or episodes of pulmonary embolism Uncontrolled congestive heart failure GENERAL EQUIPMENT SPECIFICATIONS Model # SC-2008 - Sequential 8 is an 8 chamber, Gradient, Sequential Pneumatic Compression Device. DIMENSIONS: H X W X D in INCHES 5.5 x 12 x 8 WEIGHT: 8 lbs INFLATION: 44 Seconds DEFLATION: 5.5 SECONDS CYCLE TIME: 5.5 SECONDS / CHAMBER ( Electrical Specifications under separate section) PACKAGING, SHIPPING & STORAGE The Model # SC-2008 is shipped in a specially designed (275 test) corrugated reusable carton with protective end-caps which envelope each end of the pump, thereby suspending the pump on all four sides within the carton. This packaging design prevents damage to the pump (which would ordinarily be sustained) when the carton is thrown or handled roughly by the carriers. NOTE: The carton and end-caps should be saved for re-use each time the pump is either transported or shipped. When transporting, for added convenience, the carton is equipped with a fold-up handle assembly The device should be stored in a secure area, ideally 60 to 80 degrees (F), however, short term storage or shipping with exposure to temperatures of 20 F to +110 F will not harm the unit. To maximize the unit s life, however, time should be allowed for temperature adjustment prior to use, when moving to areas of contrasting temperature. It is also advisable to avoid extreme heat ( +110 F) or cold (-20 F) when long term storage is contemplated. 4

CONTROLS & INDICATORS 3 2 1 4 5 4a 5a CONTROL DESCRIPTIONS 1.) Lighted On/Off Switch 2.) Pressure Adjustment Knob, Locking To prevent against involuntary changes in the pressure setting due to inadvertent movement of the Pressure Adjustment Knob, a new locking Knob has been implemented on all model pumps to provide for safer, more effective therapy. After the pressure has been set, simply by turning the smaller inner locking knob clockwise to tighten, the pressure adjustment knob will now remain secure in place. Turning the inner knob counter -clockwise will enable the pressure adjustment knob to again turn free without resistance. Caution: Care must be taken not to Over-Tighten the inner locking knob as only minimal force is required to lock pressure setting in place. Note: Changing the inner knob to a 1/2 x 8/32 Allen head set screw will upgrade this feature to tamper proof. 3.) Pressure Gauge (mmhg) 4.) Air Ports (Numbered) Ports #1-#4 Ports #5-#8 4a) Capped Air Supply Ports for Latch Connector Bar Blocker Ports #1-#4 Ports #5-#8 NOTE: Unless using Bilaterally, Ports should remain capped off and removed only when the addition of a second garment is required. 5.) Receptor Ports for Latch Connector Bar 5a.) Auxiliary Receptor Ports for additional Latch Connector Bar when bilateral treatment is employed 5

UPPER EXTREMITY GARMENT WITH TUBING PLUGS ATTACHED 6 6 6. Latch Connector Bar To match up with air intake ports on face of pump. 6

ELECTRICAL SPECIFICATIONS The Model # SC-2008, Sequential Circulator s electrical pump and components are double insulated and thus do not require a protective ground. As a result, the Model #SC-2008 is equipped with an 18 gauge, 2-wire, 10 ft. power cord, secured through the pump casing with a Heyco strain relief bushing. Affixed to the rear exterior of the pump is a 3 x 3 Foil Label containing the Electrical Specifications printed in contrasting black type. These specifications are printed in both English and French and contain the following: ELECTRICAL RATING: 120 VAC, 60Hz, 0.5 A CARACTERISTIQUES ELECTRIQUES: 120 V c.a., 60 Hz, 0, 5 A When servicing, use only identical replacement parts. Do not remove cover. Refer to qualified service personnel. Lors des reparations, utilisez, exclusivement des pieces de re change identiques. No retirez pas le couvercle. Consultez un tech niciaen qualifie. WARNING: REPLACE FUSE WHERE MARKED ADVERTISSEMENT: REMETTRE LE FUSIILE A L ENDROIT INDIQUE Fuse rated 3 Amps Time Delay, 250 VAC Fusible de 3 A a retardemente, 250 V c.a. Continuous Operation with Intermittent Loading TYPE B APPLIED PART CLASS II Pie ce Applique e Type B CLASSE II ETL 9801681 CONFORMS TO CONFROM A CE UL Std 60601-1 Authorized service personnel, in addition to possessing proper tools and testing equipment have access to electrical schematics, calibration criteria and an inventory of identical replacement parts. 7

CLASSIFICATION 1. Class of protection against electrical shock.. CLASS II EQUIPMENT 2. The degree of protection against electric shock.. APPLIED PART TYPE B 3. Mode.. CONTINUOUS OPERATION WITH INTERMITTENT LOADING 4. According degree of protection against ingress of water.. IPXO FUSE REPLACEMENT Occasionally power surges, etc. or normal age can result in a blown outer safety fuse located in the rear of pump, adjacent to the power cord. The safety fuse may be replaced by the user or caregiver, provided it is replaced with an identical type (T3AL 250V). Prior to removal of fuse, disconnect power cord from socket. While pushing inward on fuse cap, turn counter clockwise to release cap and remove fuse. After placing new fuse in cap slot, push cap and fuse inward and turn clockwise to lock in place. NOTE: The outer safety fuse is the only item serviceable by someone other than a Bio Compression Systems technician at the factory. Bio Compression Systems technicians have been trained specifically for the manufacturing and repair of all Bio Compression Systems products. NOTE: Having no electromagnetic or radio frequency signal sensitive type components, this device neither generates, nor is it affected by any of this type of interference. Further, its accuracy remains consistent in the presence of such devices emitting this normal type of interference PUMP ENCLOSURE The pump enclosure is constructed of Cycolac which is a trademark of General Electric. UL FLAME RATING: Under file #E47016, The UL Test method of UL 94, @ 23 C, resulted in a Flammability Rating of (2.3 VO) 8

UNPACKING EQUIPMENT SEQUENTIAL CIRCULATOR By laying carton on its side, slide pump out with protective end caps still attached. After removing pump from carton, protective end caps may be detached by gently pulling off each side. NOTE: Be sure to SAVE carton and end caps for future transporting or shipping. When transporting, the carton is equipped with fold-up handles for easy carrying. SLEEVE/GARMENT Remove sleeve from package and unroll both tubing sections which are permanently attached to garment with tubing plugs attached to the end of each tubing section. TUBING: The garment tubing is produced in pleural form consisting of two groups of 4 tubes bonded together and color coded with 3 tubes in blue and 1 tube in black. This color coding prevents attachment of both tubing bundles to the pump is reverse order. The tubing is 80A durometer PVC with each tube measuring.281 x.187 with a Tolerance of +/-.005. OPERATING INSTRUCTIONS Having familiarized yourself with controls and features of this equipment, you are now ready to begin your treatment according to your physician s prescribed course of therapy. 1. Make sure that your circulator is plugged into a safe, properly secured, 110 V, AC outlet. 2. Place unit on a sturdy table or other type of surface closed to where you will be sitting. The unit has non-slip rubberized feet on the bottom, however placing paper or other items underneath may defeat that purpose, causing the unit to slide off of surface. 3. Setting /Adjusting Pressure Each of the 8 chambers has a fill time of only 5.5 seconds per cycle. Setting the pressure is accomplished by adjusting the pressure only during the filling of chamber #1 which only allows you 5.5 seconds and may require repeating the procedure below until the desired pressure is attained. Once the pressure in chamber #1 is set, the pump automatically proportionally adjusts lower gradient pressures in the remaining chambers (#2 through #8). 9

Loosen the inner locking knob by turning a few turns counter clock-wise enabling the pressure adjustment knob (the larger knob) to turn freely. If the pump is running, shut pump off and wait for the switch light to go out. Remember, often when shutting pump off, the switch light will remain on until the cycle is completed, making it ready to start on chamber #1 when beginning your next treatment. Once switch light goes out, you are ready to start your pressure adjustment. Press switch to on position and immediately turn knob clock-wise to increase the pressure setting or counter clock-wise to decrease pressure setting as reflected on the gauge needle. Remember, you can only adjust the pressure while chamber #1 is in the filling cycle. Once the needle on the gauge dips momentarily and air is no longer coming out of port #1, you must shut pump off (if setting is not completed) and wait for switch light to go out before repeating procedure to finish setting/adjusting pressure. Once the desired pressure has been attained, tighten the smaller locking knob by turning it clock-wise. Take care not to over-tighten knob as it only takes slight pressure to lock the pressure adjustment knob in place. NOTE: You may have to repeat this procedure several times, given the short cycle time for each chamber and since you can only set the pressure on port number one, the highest pressure of the eight chambers. After you have set the desired pressure, shut the pump off until you are ready to use it and have your garment securely fastened. Remember upon shutting the pump off, the switch may stay lighted until the timer completes its cycle! Upon completion of the cycle, the switch light will automatically shut off. The physician is required to prescribe these settings, but general guidelines are listed below: 60mmHG is the general rule of thumb for most patients. However, other circumstances may require adjustments to the compression used. Presence of fibrotic tissue may require as much as 80mmHG in order to break up the fibrotic tissue and achieve reduction. Once the tissue is soft, the compression can be readjusted to 60mmHG. Patients with a history of Congestive Heart Failure, which is controlled with medication should never be in a supine position while pumping. They should be in a reclined position with elevated legs during treatment. Their treatment regimen duration may be divided into twice a day 30 minutes per treatment. 10

Patients with a history of Deep Vein Thrombosis with or without a filter may require less compression. These patients will generally tolerate 40mmHG. These patients with a filter may need to divide their treatment into twice a day, 30 minutes per treatment. It is suggested that the provider obtain a Negative Doppler study from the physician for their records. All compression settings should be discussed with the physician. It is ultimately his/her responsibility to prescribe the setting and it should be written on the prescription upon referral. Every patient is unique and communication with the physician is important when setting pressures. 4. Take the LATCH CONNECTOR BAR which is located at the end of the tubing on your garment. Holding in one hand with the numbers facing up, squeeze ends together to line up (1 to 1) & (4 & 4) to Air Supply Ports (#4) then push onto AIR SUPPLY PORTS (#4). You should hear a click when fully engaged. 5. Repeat the previous steps to attach the LATCH CONNECTOR BAR (#6) to the remaining AIR SUPPLY PORTS (#4) if using more than one garment 6. Unzip sleeve/garment gently down to bottom stop (zipper does not separate). Place garment onto arm or leg and zip up to top of garment 7. Press PUMP SWITCH (#1) up to PUMP ON position. Allow two to three complete inflation/resting cycles before the garment reaches its pre-set therapeutic pressure. At this point, you may start timing treatment duration. 8. As each chamber of the garment inflates, the PRESSURE GAUGE (#3) will dip down momentarily then return to reflect the actual pressure in the chamber. This will continue as each chamber becomes pressurized during every cycle. BILATERAL TREATMENT APPLICATION When bilateral treatment is required, remove Latch Connector Bar Blocker from Auxiliary Air Supply Ports (#4a) under controls & indicators) and attach the garment s in the same manner as previous described. 11

END OF TREATMENT When your treatment time is completed, press the Lighted Pump Switch (#1) down to the PUMP OFF position. As noted earlier, although the pump shuts off, the switch may remain lighted until the timer completes its cycle, at which time it will automatically shut off. Once the light has shut off, if desired you may remove plug to cut total power from device. It is now safe should you wish to disconnect garment from your arm or leg as well as from pump. 1. Squeeze LATCH CONNECTOR BAR (#6) and pull outward to remove garment from pump. 2. Grasp four tubes in hand near LATCH CONNECTOR BAR (#6) and pull plug outward away from pump to remove. 3. First gently bend your arm or leg (depending where garment is located) to release partial air from chambers. 4. Continue to assist in the evacuation of air from garment, working from top to bottom. 5. Once the garment feels loose enough, you can unzip the garment all the way to bottom and remove. 12

WARRANTY INFORMATION You can feel confident that your product is backed by the best warranty in the industry covering any and all malfunctions (including parts and labor) resulting from component and/or manufacturing defects. Compression Pump = 3 years from date of purchase / invoice Sleeves/Garments = 1 year from date of purchase / invoice NOTES: Serial Number: Date Purchased: Local Representative/Dealer: Phone Number: REPAIR SERVICE 1-800-888-0908 BIO COMPRESSION SYSTEMS, INC. 120 West Commercial Ave., Moonachie, NJ 07074 www.biocompression.com 13

MAINTENANCE AND STORAGE Exterior Pump Case Cleaning Instructions: 1. Clean the exterior case and tubing with a damp (not wet) cloth using mild soap and water solution once per month or as needed. WARNING! Only an authorized technician may open the pump Before cleaning, unplug power cord from electrical outlet GARMENT CLEANING/DISINFECTING INSTRUCTIONS: Disconnect garment from device. 2. Open garment to expose all sides either by separating Velcro type hook and loop or by unzipping (depending on type of garment). WARNING! Do not allow liquids to enter the pump, as this can present an electrical hazard Always allow the pump to dry before using Do not use bleach on the pump 3. Cleaning solution should consist of 1/3 cup of laundry detergent per 1 gallon of warm tap water. Use either a large sink or plastic tub able to hold enough solution (depending on size and quantity of garments) to completely submerge the garment leaving the latch connector bars out of the water. 4. Garment should be soaked for 30 minutes with mild agitation every 5 to 10 minutes while keeping it below water surface. 5. Thoroughly rinse garment with warm tap water and allow to air dry. WARNING! Never allow the Latch Connectors to be submerged into the water. If water enters the inside of the garment, damage may occur to the device. 6. Harder to remove soil on surface of garment may require additional washing by hand with a clean towel while submerged. Avoid using any abrasive materials such as scrubbing pads or chemicals that could cause damage to the exterior surface of garment. 7. Re-Submerge garment for 30 minutes (with exception of tubing connectors) in solution consisting of 1 cup of bleach per 1 gallon of warm tap water, again agitating garment every 5 to 10 minutes while keeping garment below water surface. Rinse garment thoroughly with warm tap water and allow to air dry. This completes the disinfecting step. WARNING! DO NOT place garment in washing machine. WARNING! DO NOT use the tubing or valves as handles for carrying, handing or storing garment. 14

OTHER BIO COMPRESSION SYSTEMS PRODUCTS ALSO AVAILABLE: SEQUENTIAL CIRCULATOR MODEL 2004 SEQUENTIAL CIRCULATOR MODEL 2004-FC (FAST CYCLE) SEQUENTIAL CIRCULATOR MODEL 3004 SEQUENTIAL CIRCULATOR MODEL 3004-FC (FAST CYCLE) SEQUENTIAL CIRCULATOR MODEL 3008 THE BIOCRYO SYSTEM MULTI-FLO DVT COMBO PROPHYLASIX SYSTEM BIOARTERIAL PLUS (ARTERIAL BLOOD FLOW ENHANCEMENT SYSTEM) COMPRESSION THERAPY GARMENTS INCLUDING OUR CUSTOM GARMENTS 15

O r g a n i z a t i o n Bio Compression Systems, Inc. 120 West Commercial Avenue Moonachie, NJ 07074 Toll-Free Phone: 800-888-0908 / Phone: 201-939-0716 Fax: 201-939-4503 E-mail: biosystems@biocompression.com Website: www.biocompression.com Emergo Europe Prinsessegracht 20 2514 AP, The Hague The Netherlands L-005 Rev. B 16