Technical Application Guide for UP-SHINE LED Panel Light UP-PL-4W-AN
Introduction Up-shine LED panel adopts high lumen SMD LED with CRI >8. Top branded driver comes with triac dim, -1V dim and DALI dim, it has perfect dimming range and shares great compatibility with worldwide famous brand dimmers. The ultra slim profile fits seamlessly into any work place. It is available in various installation ways: embedded into ceiling, suspended with hanging wires, surface mounted in a concrete ceiling by using surface mounting frame. Up to 8% energy saving compared to standard CFL Long lifetime of 4, hours Triac dim, -1V dim, DALI dim wide beam angle CCT: K 4K 5K 57K No UV/IR light Environment friendly, without Mercury or any other hazardous substances Application notes IP4 for indoor use only Professional electrician for installation only Switch off before installation Do not touch when in use Keep away from hot steam and corrosive gas Application Areas Office & school lighting: office room, meeting room, class room etc. Commercial lighting: shopping mall, super market, retailer shops etc. Other situations: hospital, laboratory, dust-free workshop etc. Certificates SAA
Product Information 115 8 25 Technical Specifications Model Voltage Power Power Factor UP-PL-4W-AN AC2V 4W. UP-PL-4W-AN-D AC2V 4W. Driver data Sheet Lumen (±5%) CCT 55 K 75 4K 8 5K 85 57K 5 K 7 4K 75 5K 85 57K Beam angle Lifespan CRI Dimmable Dimension o 4h 8 No 115*25*8mm o 4h 8 Yes 115*25*8mm Fixture Compatibility Rated Wattage Driver data DIM Non-dim Input rated Voltage AC2V AC2V Frequency 5Hz 5Hz Input Voltage AC2-24V AC2-24V Efficiency 8% 8% Total load Wattage 4W±5% 4W±5% Power Factor.. Rated input current.2a.2a Full load output Voltage DC5-8V DC5-8V Rated output current 5mA 5mA Output current range 5mA±5% 5mA±5% Power tolerance ±5% ±5% Current output tolerance ±5% ±5% Dimming range 8%-1% Dimmer Triac dimmers Short circuit protection PASS PASS Over voltage protection PASS PASS Over temperature protection PASS PASS Withstand voltage AC75V AC75V Electrical Classification Ingress Protection Operating Temp Operating Humidity Storage Temp 4W Ⅱ IP4-2 o C~45 o C ~% -2 o C~5 o C
Spectral Distribution K 4K.8 Max=58 [1.=2].5SDCM FK.8 Max=7171 [1.=2] 2.SDCM F4K.7.7...5.4. x=.444 y=.44.5.4. x=.841 y=.81.2.2.1.1. 8 5 7 8. 8 5 7 8 5K 57K.8 Max=75 [1.=2] 1.7SDCM F5K.8 Max=742 [1.=2] 4.1SDCM F57K.7.7...5.4. x=.48 y=..5.4. x=.47 y=.54.2.2.1.1. 8 5 7 8. 8 5 7 8 Photometric Diagram K 4K - - -/+18 MH=1m C/18 C/27 Flux out: 27 lm.281ft 4., 118.8fc 1m., 7lx.52ft 8.522, 2.71fc 2m 1.7, 1.8lx 1.1ft 7.85cm 2.2ft.7cm - - -/+18 MH=1m C/18 C/27 Flux out: 28 lm.281ft 4.8, 1.fc 1m.8, 1lx.52ft 8.52,.47fc 2m 1.7, 28.lx 1.2ft 1.cm 2.41ft 21.8cm.84ft.788, 1.21fc m 4.77, 142.1lx.ft 2.55cm.84ft.787, 4fc m 4.7, 145.8lx.1ft 2.7cm 1.ft 2.11, 7.428fc 4m 22., 7.5lx 4.4ft 1.4cm 1.ft 2.1, 7.1fc 4m 22., 82.1lx 4.81ft cm - AVERAGE BEAM ANGLE(5%): 114.2 DEG -25-2 - -1-5 5 1 2 25 1.4ft 1.4, 4.754fc 5.5ft 5m 14.8, 51.17lx.25cm Height Eavg, Emax Angle: 11.8deg Diameter - AVERAGE BEAM ANGLE(5%): 11 DEG -25-2 - -1-5 5 1 2 25 1.4ft 1., 4.87fc 51.2ft 5m 14.7, 52.48lx 54.4cm Height Eavg, Emax Angle: 111deg Diameter 5K 57K - - -/+18 MH=1m C/18 C/27 Flux out: 2828 lm.281ft.5, 1.7fc 1m 5.4, 141lx.52ft 8.487,.4fc 2m 1.5, 2lx 1.2ft 1.75cm 2.ft 2cm - - -/+18 MH=1m C/18 C/27 Flux out: 284 lm.281ft 4.7,.fc 1m 7., 7lx.52ft 8.5,.82fc 2m 2.4, 1.8lx 1.1ft 1.cm 2.8ft 21.2cm.84ft.772, 2fc m 4., 145.lx.5ft 2.25cm.84ft.81, 1.7fc m 41.11, 14lx.57ft 1.8cm 1.ft 2.2, 7.7fc 4m 22.84, 81.8lx 4.78ft 4.cm 1.ft 2.148, 7.7fc 4m 2., 82.4lx 4.77ft 42.52cm - AVERAGE BEAM ANGLE(5%): 114. DEG -25-2 - -1-5 5 1 2 25 1.4ft 1.58, 4.8fc 5.8ft 5m 14.2, 52.41lx 5.75cm Height Eavg, Emax Angle: 114.47deg Diameter - AVERAGE BEAM ANGLE(5%): 114. DEG -25-2 - -1-5 5 1 2 25 1.4ft 1.75, 4.2fc 5.ft 5m 14.8, 5.8lx 5.cm Height Eavg, Emax Angle: 114.45deg Diameter
Polar Diagram Comparison - O +/-18 O O - O O - O O - O O - O O O AVERAGE BEAM ANGLE (5%): 114.2DEG C/18, 11 deg C/21, 114. deg C/24, 114.1 deg C/27, 114.4 deg Driver lifetime & LED light decay rate Driver Lifetime LED Light Decay Rate 11%.4 Lifetime (hours) 8 7 5 4 2 1 5 o C 75 o C 85 o C 5 o C o C Capacitor Tc ( o C) % Luminous Flux % 1% 5% % 85%.5..25.2. 8% 75% FLUX.1.5 U'V' 7%. 1 2 4 5 7 8 1 LifeTime (hours) Temperature The testing is operated at 25 C The lifetime of capacitor, minimum of 5, hours if operated at C, will be doubled whenever the temperature drops 1 C The highest withstand temperature of IC, MOS could be C The highest withstand temperature of LED junction temperature is C Temperature ( o C) 1 8 7 5 4 2 1 14:2:22 :2:1 1:11:1 17:2:1 17:5:1 18:44:1 1:5:1 2:2:1 21:17:1 22:8:1 22:5:1 2:5:1 :41:1 1:2:1 2:2:1 :14:1 4:5:1 4:5:1 5:47:1 :8:1 7:2:1 8:2:1 Time IC Capacitor MOS PCB Fitting Voltage transformer Environmental temperature The driver lifespan is based on capacitor working temperature.
Installation 1.Recessed into ceiling 1. Remove ceiling plaster slab 2. Connect power supply. Fix the panel light into right place 4. Stabilize the panel 2. Suspending 1. A.Fix the anchor into target place on the ceiling B.Fix the installation mount on the ceiling with plastic anchor 2. Hang the panel to ceiling with suspended installation kits. Adjust the length of steel wire. Connect the power supply. Surface mounted 1. Fix the frame on the ceiling with screw 2. Pull down the side frame. Push the panel into the frame, connect the driver 4. Install the side frame 5. Turn on the power switch, finish the installation Packaging Information SIZE(CM) N.W/pc (KGS) G.W.(KGS) Q'TY(PCS) Carton 1*22.5* 2.7 1.5 5 2'' standard container 4'' standard container CTNS Q'TY(PCS) VOLUME(CBM) 2 1 28 52 2 5 Phone: +8 755 21 72 Add: 2nd building Dingfeng High-Tech Zone, Fuyuan 1st road, Fu Yong Sub-district, Bao'an, Shenzhen China