TEMPERATURE CONTROLLERS

Similar documents
Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Series 1140 and 1141 Temperature Regulators

Indirect gas-fired air heater

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

13-1. Temperature Regulator

INSTALLATION AND MANINTENANCE INSTRUCTIONS

ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key

Marsal Deck Ovens: MB42, MB60, MB236, MB866, SD236, SD248, SD260, SD448, SD660, SD1048, SD1060, SD866, SD10866, WF42, WF60

FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS

GAS OVEN SERVICE MANUAL

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: XPN AQUAS Pool Package

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: AP AQUAS Pool Package

INFINITY FLUIDS CORPORATION

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Columbia Boiler Company

The Expertise for Components

Thermostatic mixing valves with interchangeable cartridges

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

Niles Steel Tank Hot Water Generator Installation and Operation Manual

TITAN FLOW CONTROL, INC.

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

Installation Instructions Air Pump

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

FIREPLACE INSTALLATION

BERMAD Fire Protection

SECTION P3 LINE HEATER

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

HOME OWNER S INFORMATION Induced Combustion Gas Furnace

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

TECHNICAL DATA. model c-2

Installation Guide. Engineering Excellence. Single Handle Tub & Shower Valve Set: 4010B 4011B

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

LGB Gas fired boiler

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE

SuperKlean Washdown Products

INSTALLATION & SERVICE MANUAL

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

THE HARD WATER WATER HEATER

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

24 VAC SYSTEM CONTROL KIT

EZ TANKLESS EZ 101 & 202 OPERATION & INSTALLATION MANUAL

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

569, 570, 571, 572 Series

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: OXN 400/ /802 AQUAS Pool Package

Inta City Concealed Shower Mixing Valve CT80010CP

Operation & Maintenance Manual

Powers TM Controls TH 188 Unit Mounted Thermostat

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

FLUID POWER ENERGY, INC. W229 N591 Foster Court Waukesha, WI THERMOSTATIC VALVES. Instruction and Application Guidelines

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

TECHNICAL DATA OBSOLETE

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

User s Information Manual

Model BW9 Gas-Fired Direct Vent Condensing Water Boiler

! WARNING. Before using product, read and understand instructions.

GOLD CGt. User s Information Manual. Natural gas-fired water boiler with tankless heater

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

User s Information Manual Galaxy GG/GX Series, Sentry S/SX Series and Sentinel SE Series Gas Boilers with Continuous Burning Pilot

MASCOT Quick Setup Guide

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

ECLIPSE INFORMATION GUIDE

ERGOMAX 7 INSTALLATION

569, 570, 571, 572 Series

TK-1001, 1101, 1201, 1301, 1601

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

OPERATING AND MAINTENANCE MANUAL

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

24 VAC SYSTEM CONTROL KIT

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: XPN 400/ /802 AQUAS Pool Package

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

OTO BONDER OWNER S MANUAL WITH CIRCULATING SYSTEM MACHINERY DIVISION - - L to R Unit Shown

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

INSTALLER: THIS MANUAL MUST BE LEFT WITH THE APPLIANCE. CONSUMER: KEEP THIS MANUAL FOR FUTURE REFERENCE. WARNING

SECTION 1 - INSTALLATION UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER 1.1 MODE

Mounting and Operating Instructions EB 2231 EN

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER

Wilbur Curtis Company, Inc.

Transcription:

Instruction Manual: H1 T-12 Thermostat PILOT GUARD INTRODUCTION: SCOPE: This instruction manual includes installation, operation, and parts information for the Kimray Thermostat and Pilot Guard. Refer to separate manuals for instructions covering actuators, controllers, maintenance, and accessories. When servicing valves, always use only Kimray replacement parts. For specifi c model numbers, part numbers, and repair kit numbers, refer to the Kimray Catalog, Section H1, or to the packing slip which is enclosed with each valve. Only trained and qualified individuals should attempt to install, operate, or maintain any Kimray products or accessories. The following instructions should be reviewed and completely understood before attempting any installation, operation, or maintenance. If you have any concerns or questions about these instructions, contact your Kimray sales offi ce before proceeding. AVAILABLE MODELS: SPECIFICATIONS: Normal Service: Liquid or Gas Features: Temperature Range: -30f to 750f -34c to 399c Connection Size: Connection Style: Actuation: Body Material: DESCRIPTION: 1/2 NPT, 3/4 and 1 available with separable socket NPT Direct or Indirect Cast Iron, Ductile Iron, Steel, 12L-14, 303 Stainless, 316SS6 Stainless Supply range: Safety: 5 to 30 psi.3 to 2 bar Construction Materials: Shut down of fuel gas, with manual reset Pilot fl ame monitoring Kimray thermostats are designed to control set temperature in indirect heaters, emulsion treaters, reboilers, steam generators, heat exchangers, cooler shutter controls, and salt bath heaters. The Pilot Guard is designed to monitor the pilot fl ame to a burner in case the fl ame is extinguished. A name tag is attached to the upper bonnet housing on each Thermostat. The name tag lists the serial number, model number, and pressure rating. Body T-12 Cast Iron Ductile Iron Steel Body Pilot Guard 12L-14 316SS6 Body Sep Socket Carbon Steel 316SS6 Sensing Element 304 Stainless Elastomers Nitrile Viton Afl as 1

INSTALLATION: CONCEPT: Before starting the installation of a burner control system, it is important to understand what the equipment is for and why it will be installed. Above is a typical temperature control installation, notice the redundancy. This is for YOUR SAFETY and the SAFETY of the equipment. If one component in the loop fails then the entire system is shut down. 1. Supply Gas- Usually 30 psi is required to operate the pilots and valves in the system. At any time, interrupting the fl ow of supply gas will shut the entire system down. 2. Pilot Guard - Everything starts with monitoring the pilot fl ame. Supply gas to the entire system must run through the pilot guard. If the pilot guard detects the fl ame, it will allow supply gas to pass 3. 4. to the T-12M. If the fl ame goes out, the pilot guard will block supply gas to the entire system and shut it down. T-12M - The T-12M monitors the high temperature set point of the system. When the temperature of the system is in operating range, supply gas is allowed to pass through to the T-12 and the fi rst pressure open valve. If the temperature climbs above set point in the system, the T-12M will stop supply gas to the T-12 and also to the fi rst valve on the burner main line, causing the entire system to shut down. T-12- When the system is within operating range, the T-12 will have supply gas to operate from the T-12M, then the T-12 will throttle the valve that controls the burner fl ame to maintain a constant temperature. 2

INSTALLATION CONT: BEFORE INSTALLATION: Be sure you fully understand the application, operation, and connection of the device before installing. WARNING: Only trained personnel should install or service a control valve or control device. Control valves and other control devices should be installed, operated, and maintained in accordance with international codes and regulations, manufacturer s instructions, and proven best practices. 2. Install thermostat into separable socket (recommended) being sure to use proper piping practices. Be sure to use TFE tape or pipe thread sealant on external pipe threads. 3. Install tubing from source of instrument gas, designated Instrument Supply 4. Install tubing to the diaphragm housing of the control valve being operated or when applicable the next controller, designated Output. Instrument Supply Personal injury, equipment damage, property damage, leakage, or bursting of pressure-containing parts may result if the valve is overpressured or installed where service conditions could exceed the limits given in the SPECIFICATIONS section. Overpressure protection should also be provided if the valve inlet pressure may exceed the safe working pressure of the equipment downstream. To avoid injury or damage, install pressure-relieving or pressure limiting devices to prevent service conditions from exceeding those limits. Consult the appropriate code, regulations, or standards. Consideration should be given to the potential risk of injury or property damage due to escaping fluid. To avoid such risks, install the regulator in a safe location. Separable Socket: Pilot Guard: Output 1. Remove all plastic plugs from the 1/4 NPT openings. 1/4 tubing (not provided ) must be installed. 2. Install Pilot Guard into the proper opening so that the tip of the sense rod will be in the pilot fl ame. The entire probe does not need to be emerged in the fl ame. Be sure to use TFE tape or pipe thread sealant on the external pipe threads. 1. 2. 3. 4. Inspect the openings in the vessel for foreign material and clean the connection ports to remove scale, chips, and debris. Kimray always recommends installing thermostats with separable sockets. Install the separable socket using good piping practice. Be sure to use TFE tape or pipe thread sealant on external pipe threads. A person should never stand directly over or in front of a valve or controller when the system is pressurized. Make sure the separable socket is completely submerged in liquid or fl ow stream. Partial submersion will give erratic temperature transfer to thermostat. Pack separable socket full with high temp bearing grease. This helps in heat transfer and prevents air space. 3. Install tubing from source of instrument gas, designated Instrument Supply 4. Install tubing to the diaphragm housing of the control valve being operated or when applicable the next controller, designated Output. Instrument Supply WARNING: if hazardous or fl ammable gas is being used for instrument gas, and the pilot is in an enclosed area, personal injury or property damage could result from accumulated gas being released through the vent. To avoid potential risk provide adequate ventilation or pipe away vented gas. Output Thermostat: 1. Remove all plastic plugs from the 1/4 NPT openings. 1/4 tubing (not provided) must be installed. 3

Model T-12 START-UP & TEST: WARNING: Before performing any service, be sure that the thermostat is fully isolated and that all pressure upstream and downstream has been relieved. Use bypass valves or fully shut off the process. WARNING: When handling fire always be aware of your companies fire safety rules and understand the burner manufactures start up procedures. Never assume that a check valve is fully blocking the downstream line. Never tighten any fi tting or the main connections to the thermostat while there is pressure on the line. 1. Open the bypass valve around the safety valve. If the bypass valve is omitted, proceed to step 2. 2. Adjust the Pilot Guard for an output gauge pressure reading of approximately 50% of the supply pressure. (Counterclockwise to increase pressure and clockwise to decrease pressure). 12. Making sure the T-12 is set to a higher temperature then the T-12M, push down on the reset lever of the T-12m. At this time burner valves should open and ignite the burner fl ame. 13. Monitor burner temperature until it reaches your required safety shut off temperature. Turn T-12M control knob counterclockwise until output pressure to T-12 and fi rst control valve stops. This will be your shut off temperature, make sure the temperature on your temperature gauge matches the temperature indicator on the T-12M. 14. At this time all valves should be closed and the entire system shut down. The system will need to cool below T-12M set point before setting the T-12 thermostat. 15. Once the system has cooled down, pilot light start up procedure has been repeated and burner fl ame is lighted the T-12 thermostat can be set. 16. The T-12 thermostat will control the main burner valve and maintain a constant temperature in the vessel. Once the burner fl ame is active, the temperature can be increased by turning the control knob clockwise to increase temperature or counterclockwise to decrease temperature. ( Turning T-12 thermostat more then 1 1/4 turn counterclockwise will take it out of calibration). 3. Light the pilot light according to the standard procedures taking all the necessary safety precautions. 4. 5. 6. Watch the output gauge. As the temperature increases, the pressure on the output gauge will rise upward. As this occurs, readjust the Pilot Guard control knob to maintain an output pressure of approximately 50% of the supply pressure. (Adjust the knob clockwise to decrease the output pressure). Continue the process in step 4 until little change in the pressure reading on the output gauge is observed. (This time interval could be 15-20 minutes or longer). This process adjusts the Pilot Guard to the maximum pilot fl ame temperature and insures a rapid system shut down if the pilot fl ame goes out. When the output pressure stabilizes, the control knob can be turned counterclockwise for the 100% output pressure, the Pilot Guard is now set. Close the bypass valve. TROUBLE SHOOTING: SYMPTOM Erratic temperature changes Continuous venting POSSIBLE CAUSE Bent sensing element (element should be centered in base and should ring ) Incomplete immersion of probe Oversized burner valve Dirty pilot plug seat Hole in diaphragm Weak pilot plug spring Faulty O-ring 7. 8. The burner system should now be cycled. Occasionally, drafting occurs during the burner cycle and cools down the Pilot Guard enough for shutdown. If this occurs, turn the control knob counterclockwise approximately 1/8 of a turn at a time, until drafting will not cause a system shutdown. Should the system ever shutdown, it is necessary to determine what caused the shutdown. if a cooling effect, due to drafting occurred, readjust the control knob counterclockwise approximately 1/8 of a turn at a time, until drafting will not cause a system shutdown. MAINTENANCE: Maintenance should be performed on a regular basis. An initial inspection interval of 12 months is recommended. Depending on the service conditions of the thermostat, the inspection interval may be decreased or increased. 9. To restart after shutdown, open the bypass valve and light the pilot. When the output pressure of the Pilot Guard reaches 100% of the supply pressure, the system is operating and the bypass valve must be closed. If the bypass valve has been omitted, repeat steps 2-8. 10. Once the Pilot Guard is stable, proceed to the T-12M. The next steps require that a temperature gauge be installed in the system. 11. On the T-12M and T-12 turn the control knobs clockwise until they stop. On the T-12m turn control knob counterclockwise to desired shut down temperature. ( Turning more then 1 1/4 revolutions will take the thermostat out of calibration). 5 WARNING: If the thermostat leaks fluid, it indicates that service is required. Failure to take the thermostat out of service immediately may create a hazardous condition. Detailed repair instructions are available for your specifi c thermostat. Repair Kits are available. Consult the Kimray Catalog, Section H, or the packing slip which is enclosed with each valve for the correct Repair Kit number.

This is a general representation of a Pilot Guard. For specifi c parts and their orientation refer to the Kimray Catalog or the packing slip which is enclosed with each regulator. Key Description Key Description Key Description 1. O ring 11. Pilot Plug 21. Sensing rod extension 2. Seat 12. Seat 22. Spool 3. Adjusting Knob 13. Bellow Assembly 23. Base Assembly 4. Name plate 14. Gasket 24. O ring 5. Set screw 15. Gasket 25. Screw 6. Drive screw 16. Breather Plug 26. Spring 7. Cap 17. 1/4 NPT 27. Bonnet 8. Screw 18. Metal Diaphragm 28. Nipple 9. Gauge 19. Sensing Rod 29. Tee 10. Supply Connection 20. 1 NPT 30. Output 6

Model T-12 This is a general representation of a Pilot Guard. For specifi c parts and their orientation refer to the Kimray Catalog or the packing slip which is enclosed with each regulator. Key Description Key Description Key Description 1. Bonnet 9. Output connection 17. 1/4 OD Tubing 2. Dial 10. Pilot plug 18. Supply connection 3. O ring 11. Seat 19. 1/2 NPT 4. Seat 12. Upper plate 20. Base 5. Pointer 13. Diaphragm 21. Screw 6. Set screw 14. Lower plate 22. Spring 7. Drive screw 15. 1/8 NPT 23. Housing 8. 1/4 NPT 16. Elbow 7