Small Digital Thermostat Controller Temperature Control

Similar documents
5+2 Day. up to HEAT COOL

Installation Instructions

Installation Instructions HEAT COOL FAN POWER

7-Day. Digital Thermostat. residential. & 2-cool

asy Single Day up to 2-heat & 2-cool Stat

HEAT COOL 5+2 DAY PROGRAMMABLE 1-STAGE HEAT, 1-STAGE COOL. Installation Instructions TSTATCCPQ501 TSTATBBPQ501 P Digital Thermostat I2:00

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

Installation Instructions

Owner s Manual. Digital Thermostat. Non-Programmable

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCNB001 TSTATBBNB001 P Digital Thermostat

Installation Instructions

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCPS101 TSTATBBPS101 P Digital Thermostat 6:03

Installation Instructions

Non-Programmable Digital Thermostat

2 - Wire Programmable Digital Thermostat

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

OWNER'S MANUAL T0140. Contents Page #

HEAT HEAT PUMP TOTALINE. Installation Instructions DIGITAL THERMOSTAT MODEL P FM. I2:00 Mo COOL

INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

HEAT HEAT HEAT COOL COOL

Programmable 5-2 Day Digital Thermostat

Owner s Manual. Digital Thermostat

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

5+2 Day. up to HEAT COOL

INSTALLATION INSTRUCTIONS FAN COIL PROGRAMMABLE DIGITAL THERMOSTAT. Meets California Title 24

XFlat Blade. Installation Instructions DIGITAL THERMOSTAT 53DFS250-SL. CoolingOnly,Heat Cool,and Heat Pump MULTI-STAGE SEVEN DAY PROGRAMMABLE

HEAT COOL HEAT PUMP MULTI-STAGE SINGLEDAYPROGRAMMABLE TSTATCCPB101 TSTATBBPB101 P Digital Thermostat

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat:

5+2 DAY INSTALLATION. Digital Thermostat. residential. & 1-cool. up to. 1-heat PROGRAMMABLE HEAT COOL HEAT PUMP THERMOSTAT. Venstar Inc.

7-Day. Digital Thermostat. residential. & 2-cool

Auto-Changeover: A mode in which the thermostat will turn on the heating or cooling based on room temperature demand.

WARNING Important Safety Information

WARNING Important Safety Information

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

INSTALLATION INSTRUCTIONS

DIGITAL THERMOSTAT Up To 2 Heat & 2 Cool Stages with Humidity Control

OWNER S MANUAL Venstar Inc. 08/07

Auto-Changeover: Cool Setpoint: Deadband: Differential: Heat Setpoint: Icon: Mode: Non-Programmable Thermostat: Programmable Thermostat:

SC Installation, Operation & Application Guide

HEAT HEAT HEAT COOL COOL

PRO Installation. Touch Wi-Fi Thermostat

CTS Series. Owner s Manual. Full Color Touch Screen Display. and Installation Instructions. High Resolution Digital Thermostat

Safety & Installation Instructions

SC Installation, Operation & Application Guide

T-32-TS Touchscreen Thermostat. Installation Manual

Safety & Installation Instructions

Safety & Installation Instructions

OWNER S MANUAL Venstar Inc. 08/07

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

PRO Installation. Touch Wi-Fi Thermostat

WARNING Important Safety Information

OWNER S MANUAL Venstar Inc. 08/07

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

PRO Installation. Thermostat Wi-Fi

HEAT COOL. Meets Commercial California Title 24

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

SC Installation, Operation & Application Guide

Owner s Manual. Premier Series Digital Thermostat. and Installation Instructions. Non-Programmable with Humidity Control COMMERCIAL

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Installation Instructions

PECO. WavePRO Wireless System INSTALLATION GUIDE: T2500 THERMOSTAT AND R2500 RECEIVER. The Peco WavePRO Wireless System

COMMERCIAL. model SFTHCP742WFC. Premier Series Digital Thermostat. Programmable. Owner s Manual. and Installation Instructions

Installation Instructions

RTH8500 Series. Quick Installation Guide. Included in your box. Programmable Thermostat. Quick Install Guide Screws and anchors. RTH8500 Thermostat

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

Programmable 5-2 Day Digital Thermostat

WARNING Important Safety Information

Programmable Thermostat

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Commercial Touchscreen Thermostat

CT2800 Programmable Thermostat

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

ATP21W02 CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS REMOVING OLD THERMOSTAT 2 THERMOSTAT DETAILS

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

P/N TSTAT0709 DIGITAL THERMOSTAT. Installation Instructions HEAT COOL. Warmer HEAT PUMP. International Comfort Products 2003

INSTRUCTION MANUAL P Heating and 1 Cooling

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

Set & $ave. Model Programmable Thermostat. installation and operation manual

Safety & Installation Instructions

CAUTION. FCC Compliance Statement

Installation, Start-Up, and Operating Instructions

WARNING Important Safety Information

CAUTION. FCC Compliance Statement

tcu.z Commercial Programmable Thermostat Installation Instructions

MagicStat CT3300 Programmable Thermostat

SC Installation, Operation & Application Guide

Installer Guide. WARNING Important Safety Information. 1 Specifications

Comfort System T-21-P Touchscreen Thermostat Installation Manual

7-DAY or 5/2-DAY PROGRAMMABLE, OR NON-PROGRAMMABLE THERMOSTAT INSTALLATION AND OPERATING INSTRUCTIONS

Programmable Thermostat

Operator: Save these instructions for future use!

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Siemens Thermostats. RDY2000BN Thermostat

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

1 For All Programmable Digital Thermostat

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

Transcription:

www.klimaireintl.com Small Digital Thermostat Controller Temperature Control Small-Fiac IOM Manual KLIMAIRE International +1.647. 477. 3333 +1.646. 808. 0240 klimaireintl@klimaireintl.com

Digital Thermostat residential THERMOSTAT T1010 Single Day PROGRAMMABLE up to 2-heat & 2-cool HEAT COOL HEAT PUMP Control up to 2 Heat & 2 Cool Stages HP Stages: 2 Heat, 2 cool Single Day Programmable 4 Settings Per Day Auto Changeover 5 min. Built-In Compressor Protection Back-Lit Display One For All Works with Virtually All Equipment O or B Terminal Non-Volatile Memory Keypad Lockout Display Either F or C Use with most Air Conditioning & Heating Systems including: 1 or 2 Stage Electric Cooling & 2 Stage Gas Heating, Heat Pump, Electric or Hydronic Heat. INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

Table Of Contents Step #1: Preparation Step #2: Remove & Replace Old Thermostat Step #3: Wire Connections 2 3 4 Sample Wiring Diagrams 5 Step #4: Test Operation Trouble Shooting 12 13 CAUTION Follow Installation Instructions carefully. DISCONNECT POWER TO THE HEATER - AIR CONDITIONER BEFORE REMOVING THE OLD THERMOSTAT AND INSTALLING THE NEW THERMOSTAT. WARNING P/N T1010 This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

AUTO AUTO AUTO AUTO AUTO STEP #1 COOL 76 HEAT 68 PREPARATION Proper installation of the thermostat will be accomplished by following these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance. COOL 76 Assemble tools. HEAT 68 Flat Blade Screwdriver Wire cutter & Stripper Drill with 3/16 inch Drill Bit (when not using j-box) COOL 76 HEAT 68 COOL 76 HEAT 68 Make sure your Heater/Air Conditioner is working properly before beginning installation of the thermostat. Carefully unpack the thermostat. Save the screws, wall anchors, and instructions. COOL 76 HEAT 68 Turn off the power to the Heating/Air Conditioning system at the main fuse panel. Most residential systems have a separate breaker for disconnecting power to the furnace.

AUTO AUTO AUTO AUTO STEP #2 COOL 76 HEAT 68 COOL 76 HEAT 68 REMOVE & REPLACE OLD THERMOSTAT Remove the cover of the old thermostat. If it does not come off easily check for screws. Loosen the screws holding the thermostat base or subbase to the wall, and lift away. COOL 76 HEAT 68 COOL 76 HEAT 68 Disconnect the wires from the old thermostat. Tape the ends of the wires as you disconnect them, and mark them with the letter of the terminal for easy reconnection to the new thermostat. Keep the old thermostat for reference purposes, until your new thermostat is functioning properly.

AUTO STEP #3 WIRE CONNECTIONS COOL 76 HEAT 68 If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below, or the wiring diagrams that follow. Wire from the old thermostat terminal marked Function Install on the new thermostat connector marked G or F Fan G Y1, Y or C Cooling Y1 W1, W or H Heating W1,O,B Rh, R, M, Vr, A Power R C Common C * O/b Rev. Valve W1,O,B** Y2 W2 2nd Stage Cool 2nd Stage Heat Y2 W2 * C may not be used on all systems. ** O/b is used if your system is a Heat Pump.

Sample Wiring Diagrams Gas or Electric Heat 5 Wire, 1 Stage Cooling, 1 Stage Gas Heat Residential Gas or Electric Heat*, Electric Cool, split systems & package units R G Y1 W2 W1 Y2 C B O POWER FAN COMPRESSOR GAS VALVE or STRIP HEAT COMMON R G Y W C * If using first stage electric heat, this option must be selected ON (see page 11, step #6 of Owner s Manual).

Sample Wiring Diagrams Gas or Electric Heat 4 Wire, 1 Stage Cooling, 1 Stage Gas Heat Residential Gas or Electric Heat*, Electric Cool, split systems & package units R G Y1 W2 W1 Y2 C B O POWER FAN COMPRESSOR GAS VALVE or STRIP HEAT R G Y W * If using first stage electric heat, this option must be selected ON (see page 11, step #6 of Owner s Manual).

Sample Wiring Diagrams Gas or Electric Heat 6 Wire, 2 Stage Cooling, 1 Stage Gas Heat Residential two stage cooling with Gas or Electric Heat*. B O R G Y1 W2 W1 Y2 C POWER FAN COMPRESSOR GAS VALVE or STRIP HEAT 2nd STAGE COOLING COMMON R G Y W Y2 C * If using first stage electric heat, this option must be selected ON (see page 11, step #6 of Owner s Manual).

Sample Wiring Diagrams Gas or Electric Heat 6 Wire, 1 Stage Cooling, 2 Stage Heat Residential & commercial 1 Stage Cooling, with 2 Stage Gas or Electric Heat* B O R G Y1 W2 W1 Y2 C POWER FAN COMPRESSOR 2nd STAGE HEATING GAS VALVE or STRIP HEAT COMMON R G Y W2 W C * If using first stage electric heat, this option must be selected ON (see page 11, step #6 of Owner s Manual).

Sample Wiring Diagrams Gas or Electric Heat 7 Wire, 2 Stage Cooling, 2 Stage Heat Commercial Gas or Electric Heat *, Electric Cool, split systems & package units including Commercial Heat Pumps ** B O R G Y1 W2 W1 Y2 C POWER FAN COMPRESSOR 2nd STAGE HEATING GAS VALVE or STRIP HEAT 2nd STAGE COOLING COMMON R G Y W2 C Y2 W * If using first stage electric heat, this option must be selected ON (see page 11, step #6 of Owner s Manual). ** Commercial heat pumps do not have the heat pump turned ON in advanced setup (see page 11, step #4 of Owner s Manual).

Sample Wiring Diagrams Heat Pump 5 Wire, 1 Stage Cooling, 1 Stage Heat-Heat Pump* with O or b reversing valve**. Residential Heat Pumps, split systems & package units, with no auxiliary heat. R G Y1 W2 W1 Y2 C B O POWER FAN COMPRESSOR R G Y REVERSING VALVE** O/B COMMON C * This option must be selected ON during advanced setup (see page 11, step #4 of Owner s Manual). ** This option must be selected O or b during advanced setup (see page 11, step #5 of Owner s Manual).

Sample Wiring Diagrams Heat Pump 6 Wire, 1 Stage Cooling, 2 Stage Heat-Heat Pump* with O or b reversing valve**. Residential Heat Pumps, split systems & package units, with auxiliary heat. B O R G Y1 W2 W1 Y2 C POWER FAN COMPRESSOR 2nd STAGE HEATING REVERSING VALVE** COMMON R G Y W2 O/B C * This option must be selected ON during advanced setup (see page 11, step #4 of Owner s Manual). ** This option must be selected O or b during advanced setup (see page 11, step #5 of Owner s Manual).

AUTO AUTO AUTO AUTO STEP #4 COOL 76 HEAT 68 TEST OPERATION Turn the power on to the Heating/Air Conditioning system. COOL 76 HEAT 68 COOL 76 HEAT 68 COOL 76 HEAT 68 Press the MODE button repeatedly until the HEAT icon appears on the display. Press the UP or DOWN buttons until the set temperature is 10 degrees above room temperature. The HVAC unit should energize in the heating mode. Press the MODE button repeatedly until the COOL icon appears on the display. Press the UP or DOWN buttons until the set temperature is 10 degrees below room temperature. The HVAC unit should energize in the cooling mode. NOTE: Most equipment has a time delay of 5 minutes between cool cycles. This feature is defeatable on the thermostat (see page 12, step #9 of Owner's Manual). Press the UP button until the setpoint is equal to the room temperature. Press the FAN button to Fan On. The fan should turn on and run continuously.

AUTO AUTO AUTO TROUBLESHOOTING COOL 76 HEAT 68 SYMPTOM: When using 4 wires (R, G, W, Y), the air conditioning equipment tries repeatedly to turn on, but cannot. At times the display dims or disappears. CAUSE: There is not enough power available to "power share". REMEDY: Connect a 270 ohm, 10 watt power resistor at the furnace as shown below. For Problem A/C For Problem Heat R G W Y C R G W Y C TR300-10w TR300-10w COOL 76 HEAT 68 SYMPTOM: The air conditioning does not attempt to turn on. CAUSE: The compressor timer lockout may prevent the air conditioner from turning on, for a period of time. REMEDY: See page 12 of the Owner's Manual and configure step #9 to defeat the 5- minute compressor lockout. COOL 76 HEAT 68 SYMPTOM: The display is blank. CAUSE: Lack of proper power. REMEDY: Make sure power is turned on to the furnace and 24vac between R & W. If C is used, 24vac between R & C.

AUTO AUTO TROUBLESHOOTING COOL 76 HEAT 68 COOL 76 HEAT 68 SYMPTOM: When controlling a residential heat pump, and asking for cooling, the heat comes on. CAUSE: Heat pump is not selected "ON" in the Advanced Setup. REMEDY: See page 11 of the Owner's Manual and configure step #4 to enable heat pump operation. SYMPTOM: When calling for cooling, both the heat and cool come on. CAUSE: The thermostat is configured to control a heat pump and the HVAC system is a "conventional" (non-heat pump) system. REMEDY: See page 11 of the Owner's Manual and set step #4 to OFF to enable gas electric operation. 4Z95 STAR FCc T1010 Tested to Comply with FCC Standards FOR HOME OR OFFICE USE

Digital Thermostat residential THERMOSTAT T1050 5+2 Day PROGRAMMABLE up to 2-heat & 2-cool HEAT COOL HEAT PUMP Control up to 2 heat & 2 Cool Stages 4 Settings Per Day Self-prompting programming Auto changeover Separate weekday, Saturday & Sunday programming Back-Lit display One For All Works with Virtually All Equipment 5 minute Built-In Compressor Protection Non-Volatile memory Dual setpoint with adjustable deadband Keypad lockout O or B Terminal Display either F or C Use with most Air Conditioning & Heating Systems including: 1 or 2 Stage Electric Cooling & 2 Stage Gas Heating, Heat Pump, Electric or Hydronic Heat. INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

Table Of Contents Step #1: Preparation Step #2: Remove & Replace Old Thermostat Step #3: Wire Connections 2 3 4 Sample Wiring Diagrams 5 Step #4: Test Operation Trouble Shooting 12 13 CAUTION Follow Installation Instructions carefully. DISCONNECT POWER TO THE HEATER - AIR CONDITIONER BEFORE REMOVING THE OLD THERMOSTAT AND INSTALLING THE NEW THERMOSTAT. WARNING P/N T1050 This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

STEP #1 Proper installation of the thermostat will be accomplished by following these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance. Assemble tools. PREPARATION Flat Blade Screwdriver Wire cutter & Stripper Drill with 3/16 inch Drill Bit (when not using j-box) Make sure your Heater/Air Conditioner is working properly before beginning installation of the thermostat. Carefully unpack the thermostat. Save the screws, wall anchors, and instructions. Turn off the power to the Heating/Air Conditioning system at the main fuse panel. Most residential systems have a separate breaker for disconnecting power to the furnace.

STEP #2 REMOVE & REPLACE OLD THERMOSTAT Remove the cover of the old thermostat. If it does not come off easily check for screws. Loosen the screws holding the thermostat base or subbase to the wall, and lift away. Disconnect the wires from the old thermostat. Tape the ends of the wires as you disconnect them, and mark them with the letter of the terminal for easy reconnection to the new thermostat. Keep the old thermostat for reference purposes, until your new thermostat is functioning properly.

STEP #3 WIRE CONNECTIONS If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below, or the wiring diagrams that follow. Wire from the old thermostat terminal marked Function Install on the new thermostat connector marked G or F Fan G Y1, Y or C Cooling Y1 W1, W or H Heating W1,O,B Rh, R, M, Vr, A Power R C Common C * O/b Rev. Valve W1,O,B** Y2 W2 2nd Stage Cool 2nd Stage Heat Y2 W2 * C may not be used on all systems. ** O/b is used if your system is a Heat Pump.

Sample Wiring Diagrams Gas or Electric Heat 5 Wire, 1 Stage Cooling, 1 Stage Gas Heat Residential Gas or Electric Heat*, Electric Cool, split systems & package units O R G Y1 W2 W1 Y2 C B POWER FAN COMPRESSOR GAS VALVE or STRIP HEAT COMMON R G Y W C * If using first stage electric heat, this option must be selected ON (see page 12, step 5 of Owner s Manual).

Sample Wiring Diagrams Gas or Electric Heat 4 Wire, 1 Stage Cooling, 1 Stage Gas Heat Residential Gas or Electric Heat*, Electric Cool, split systems & package units O R G Y1 W2 W1 Y2 C B POWER FAN COMPRESSOR GAS VALVE or STRIP HEAT R G Y W * If using first stage electric heat, this option must be selected ON (see page 12, step 5 of Owner s Manual).

Sample Wiring Diagrams Gas or Electric Heat 6 Wire, 2 Stage Cooling, 1 Stage Gas Heat Residential two stage cooling with Gas or Electric Heat*. O R G Y1 W2 W1 Y2 C B POWER FAN COMPRESSOR GAS VALVE or STRIP HEAT 2nd STAGE COOLING COMMON R G Y W Y2 C * If using first stage electric heat, this option must be selected ON (see page 12, step 5 of Owner s Manual).

Sample Wiring Diagrams Gas or Electric Heat 6 Wire, 1 Stage Cooling, 2 Stage Heat Residential & commercial 1 Stage Cooling, with 2 Stage Gas or Electric Heat* O R G Y1 W2 W1 Y2 C B POWER FAN COMPRESSOR 2nd STAGE HEATING GAS VALVE or STRIP HEAT COMMON R G Y W2 W C * If using first stage electric heat, this option must be selected ON (see page 12, step 5 of Owner s Manual).

Sample Wiring Diagrams Gas or Electric Heat 7 Wire, 2 Stage Cooling, 2 Stage Heat Commercial Gas or Electric Heat *, Electric Cool, split systems & package units including Commercial Heat Pumps ** O R G Y1 W2 W1 Y2 C B POWER FAN COMPRESSOR 2nd STAGE HEATING GAS VALVE or STRIP HEAT 2nd STAGE COOLING COMMON R G Y W2 C Y2 W * If using first stage electric heat, this option must be selected ON (see page 12, step 5 of Owner s Manual). ** Commercial heat pumps do not have the heat pump turned ON in advanced setup (see page 11, step 3 of Owner s Manual).

Sample Wiring Diagrams Heat Pump 5 Wire, 1 Stage Cooling, 1 Stage Heat-Heat Pump* with O or b reversing valve**. Residential Heat Pumps, split systems & package units, with no auxiliary heat. O R G Y1 W2 W1 Y2 C B POWER FAN COMPRESSOR R G Y REVERSING VALVE** O/B COMMON C * This option must be selected ON during advanced setup (see page 11, step 3 of Owner s Manual). ** This option must be selected O or b during advanced setup (see page 12, step 4 of Owner s Manual).

Sample Wiring Diagrams Heat Pump 6 Wire, 1 Stage Cooling, 2 Stage Heat-Heat Pump* with O or b reversing valve**. Residential Heat Pumps, split systems & package units, with auxiliary heat. O R G Y1 W2 W1 Y2 C B POWER FAN COMPRESSOR 2nd STAGE HEATING REVERSING VALVE** COMMON R G Y W2 O/B C * This option must be selected ON during advanced setup (see page 11, step 3 of Owner s Manual). ** This option must be selected O or b during advanced setup (see page 12, step 4 of Owner s Manual).

STEP #4 TEST OPERATION Turn the power on to the Heating/Air Conditioning system. Press the MODE button repeatedly until the HEAT icon appears on the display. Press the UP or DOWN buttons until the set temperature is 10 degrees above room temperature. The HVAC unit should energize in the heating mode. Press the MODE button repeatedly until the COOL icon appears on the display. Press the UP or DOWN buttons until the set temperature is 10 degrees below room temperature. The HVAC unit should energize in the cooling mode. NOTE: Most equipment has a time delay of 5 minutes between cool cycles. This feature is defeatable on the thermostat (see page 13, step 8 of Owner's Manual). Press the UP button until the setpoint is equal to the room temperature. Press the FAN button to Fan On. The fan should turn on and run continuously.

TROUBLESHOOTING SYMPTOM: When using 4 wires (R, G, W, Y), the air conditioning equipment tries repeatedly to turn on, but cannot. At times the display dims or disappears. CAUSE: There is not enough power available to "power share". REMEDY: Connect a 250 ohm, 10 watt power resistor at the furnace as shown below. For Problem A/C For Problem Heat R G W Y C R G W Y C TR300-10w TR300-10w SYMPTOM: The air conditioning does not attempt to turn on. CAUSE: The compressor timer lockout may prevent the air conditioner from turning on, for a period of time. REMEDY: See page 13 of the Owner's Manual and configure step 8 to defeat the 5- minute compressor lockout. SYMPTOM: The display is blank. CAUSE: Lack of proper power. REMEDY: Make sure power is turned on to the furnace and 24vac between R & W. If C is used, 24vac between R & C.

TROUBLESHOOTING SYMPTOM: When controlling a residential heat pump, and asking for cooling, the heat comes on. CAUSE: Heat pump is not selected "ON" in the Advanced Setup. REMEDY: See page 11 of the Owner's Manual and configure step 3 to enable heat pump operation. SYMPTOM: When calling for cooling, both the heat and cool come on. CAUSE: The thermostat is configured to control a heat pump and the HVAC system is a "conventional" (non-heat pump) system. REMEDY: See page 11 of the Owner's Manual and set step 3 to OFF to enable gas electric operation. 4Z95 STAR FCc T1050 Tested to Comply with FCC Standards FOR HOME OR OFFICE USE