UL Revision 5. - Commercial Door Installations -

Similar documents
STANDARDS UPDATE NOTICE (SUN) ISSUED: March 19, 2018

NORMS AND REGULATIONS FOR AUTOMATIC DOORS & ENTRANCE CONTROLS

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FT-EPB Series. Single Motor

Standards in Security Shutters & Fire Shutters (UK & USA)

STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES

Safety Standard for Automatic Residential Garage Door Operators. SUMMARY: The Consumer Product Safety Commission ( Commission or CPSC ) is

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FST-EPB Series. Single Motor

Solar Powered. Solar Powered. Model Installation/Owner s Manual. Solar Powered Vehicular Swing Gate Operator. UL 325 August 2018 Standard

Hand Chain (Model FCF) &

INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011

Fire and Smoke Door Inspections Qualified Training 02/03/17

RITTNER FRENCH ASSOCIATES Rittner French Associates / Rittner Products, Inc.

Besam SW200i-Fold Folding Door Series. Owner s Manual

CHAPTER SIX Automatic Gates

NFPA 80 Overview January 21, 2016

Get Your Firehouse Connected with the Next Generation of Commercial Door Operators from LiftMaster.

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

SAF-BCF SECOND REVISIONS WITH STATEMENTS

Federal Register / Vol. 81, No. 67 / Thursday, April 7, 2016 / Rules and Regulations

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

STANDARD DETAILS & SPECIFICATIONS Spec No _SI _ Rev. Date 10/20/11

NFPA 96, 2017 REVIEW SUMMARY

NFPA 72 is in the same cycle as NFPA 80. The extracted text will be updated with a Second Revision during the second draft meeting.

ELITE SERIES COMMERCIAL HIGH-TRAFFIC AC SLIDE GATE OPERATOR

Bold items are particular to the City of Euless

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

Floor Protectors and Wall Shields. Solar Reflectance Roof Covering Materials

SECTION EXTERIOR LIGHTING

Safety Tips for the Office

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

DIVISION 14 - CONVEYING SYSTEMS. 1. Passenger Elevators 2. Vertical Platform and Inclined Wheelchair Lifts.

MANUAL RESET ALARM RELEASE

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

GUIDELINES FOR INSPECTING GROUND BASED SPARKLING DEVICE (GBSD) RETAIL SALES FACILITIES

ARCHITECTURAL SPECIFICATIONS

NEMA Applications Guide

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

Construction Codes Advisory Council

GT1175 Slide Door OWNER S MANUAL

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

ELITE SERIES COMMERCIAL HIGH-TRAFFIC AC SWING GATE OPERATOR

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018

FAQs - Codes and Listings

SECTION WET-PIPE SPRINKLER SYSTEMS

TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2

CHECKFIRE 110 DETECTION AND ACTUATION SYSTEM

New Facilities. Minimum Requirements

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

RAGAGEP UPDATE. Douglas Reindl, Director, IRC 2016 IRC R&T Forum

Hydraulic Residential Elevator OWNER S MANUAL

dhf General Information Automated Gates Guidance for enforcement bodies

Committee Input No. 28-NFPA 13R-2013 [ Global Input ]

Engineering Specifications

About the Instructor & Presenter:

MANUAL RESET ALARM RELEASE

D. Reference Standards (Utilize latest editions available):

NFPA 45 NFPA 211 NFPA 1600

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

SURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin

1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors.

ELITE SERIES INDUSTRIAL AC SLIDE GATE OPERATOR

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ENGINEER AND THE TECHNICIAN DESIGNING FIRE PROTECTION SYSTEMS.

Report on First Revisions with Statement June 2014 NFPA 101

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

Florida Building Code 2010

CHAPTER 7 ALTERATIONS LEVEL

NFPA 72 Code Changes vs 2013

Life Safety - Means of Egress/Exits NFPA 101

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

Are You Prepared? The impending impact of Code on Servicing Security Systems

CARBON DIOXIDE SYSTEMS FOR BEVERAGE DISPENSING PERMIT REQUIREMENTS

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

RELEASE DEVICE CONTROLS

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

Public Comment No. 3-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

PHOTOLUMINESCENT EXIT SIGNS EVALUATED AND TESTED TO UL924

(h) Pesticide Application.

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

Design & Construction Standards, Revised January

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

FIRE & LIFE SAFTEY STANDARD

January 1, 2014 Mandatory Effective Date

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

MANUFACTURING TECHNICAL INSTRUCTIONS - SAFETY REVIEW DATE: 10/29/2002

Developing a Healthcare Facility Fire Door Inspection Program

Refurbishment or New Site Spot Check Checklist

INSTALLATIONN GUIDE & OPERATION MANUAL

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

SECTION AUTOMATIC TRANSFER SWITCHES

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Changes in NFPA

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

Rapid Intervention Team

ICC Update - Laboratory Issues Code Changes / Proposals / Trends of Interest 10/2005

IMC Significant Changes Summary Tier I

Transcription:

UL325 2010 Revision 5 - Commercial Door Installations -

UL325 - Scope - Door, Drapery, Gate, Louver, and Window Operators and Systems Covers electric operators for doors, draperies, gates, louvers, windows and other opening and closing appliances rated 600v or less to be employed in ordinary locations in accordance with the National Electric Code, NFPA 70

UL325 General Information UL325 contains nationally recognized minimum safety requirements Commercial compliance is voluntary, but may be site required Declaring compliance requires testing, qualification and regular inspections Compliance to UL325 required when the UL Mark is displayed AHJ s (state and local) typically rely on compliance to standards through Certification such as the UL Mark ICC/IBC NEC State and Local Building Codes

UL325 2010 Revision Presentation Topics New Guideline Background Commercial vs. Residential Applications UL Definition of Commercial Door Operator Impacted Commercial Industry Applications External Entrapment Protection Miscellaneous Instructions & Documentation ***Compliance Effective Date August 29, 2010***

Adoption of UL325 2010 Revision UL325 revisions were adopted using Standards Development Process UL325 Standard Technical Panel (STP) DASMA (Door and Access Manufacturers Assoc.), producers, supply chains UL, testing/standards organizations, Certifiers, CPSC General academia Managed through the UL Collaborative Standards Development System (CSDS) Comments to proposals anyone can participate Ballots Registered STP voters only ANSI (American National Standards Institute) has been canvassed

UL325 Commercial vs. Residential Federal law (Consumer Products Safety Commission) states that no company shall manufacture an operator for sale for use in residential applications that does not meet UL 325 requirements for such applications UL 325 Residential UL 325 Commercial / Industrial Some US States have laws that impose criminal and/or monetary penalties when using a Commercial Door Operator on a Residential installation Note: Residential installation defined as construction consisting of 1 to 4 single family units

UL325 (Current) Commercial vs. Residential Commercial Applications A door or door operators shall be provided with: Constant Pressure to Close, or Means for connecting a reversing edge switch, or equivalent that will reverse the door upon striking an object, or A three-button control station, provided that the operator 1. Does not incorporate an automatic closing control 2. Control station is located so that the door will be within sight of the person operating the control and that door is controlled by 3-button station only Residential Applications A door or door operators shall be provided with: Inherent Entrapment Protection as Primary Entrapment Protection Secondary protection: external photo eyes or edges, inherent secondary, or equivalent 30-second Maximum Run Timer, or acceptable position detector, Mandatory

UL 325 Definition of Commercial Door Operator TWO COMMERCIAL CLASSIFICATIONS 1) COMMERCIAL/INDUSTRIAL DOOR OPERATOR (OR SYSTEM) 12 Cycles or More Per Hour* A door operator (or system) intended for vehicular traffic and/or securing entrances or exits to commercial or industrial buildings areas. some examples include multi-family housing units (more than four single-family units), hotels, garages, retail stores, or loading docks including, but not limited to, sliding, swing, bi-fold, accordion, sectional, and rolling door.. Doors used to secure store fronts and intended for pedestrian use, but usually operated only at the start and end of the business day are included. Doors used solely for pedestrian access and egress which open and close for each pedestrian or group of pedestrians are not covered by this definition. *Note: The statement 12 cycles or More Per Hour used to define operators in this category has been established by LiftMaster, and not UL.

UL 325 Definition of Commercial Door Operator TWO COMMERCIAL CLASSIFICATIONS (cont.) 2) LIGHT DUTY (COMMERCIAL/INDUSTRIAL) DOOR OPERATOR (OR SYSTEM) A commercial/industrial door operator (or system) intended and marked for limited or restricted duty. Doors used to secure store fronts and intended for pedestrian use, but usually operated only at the start and end of the business day are included. Doors used solely for pedestrian access and egress which open and close for each pedestrian or group of pedestrians are not covered

Industry Application Classes Impacted by UL325 2010 Revision All Commercial Operators bearing UL Mark Commercial Door Operators» Standard and Heavy Duty Operators» Medium Duty Operators Light Duty Operators Special Applications» Fire Door Operators» N4, N4X and Carwash Operators» Sliding Door Operators

A commercial/industrial door operator shall comply with one of the following: a) Shall be constructed so that: UL 325 2010 Revision Entrapment Protection 1) The operator requires constant pressure on a control to close the door, and 2) The operator stops or reverses direction of the door when constant pressure on a control is removed prior to the operator reaching its close limit, and 3) The operator limits a portable transmitter or automatic actuation device, when supplied, to function only to cause the operator to open the door; and 4) It is not possible to make simple modifications by adding, suppressing or changing the connection of wires in the internal control circuit(s) to allow any other method of operation that does not require constant pressure on a control to close the door without also complying OR b) Shall be constructed to comply with one of the following: 1) Shall require the connection of an external entrapment protection device 2) Shall be provided with any other external device that provides entrapment protection equivalent to b.1

UL 325 2010 Revision Entrapment Protection An external entrapment protection device provided with, or as an accessory to, a commercial/industrial door operator (or system) shall consist of: a) A contact type sensor (edge sensor or equivalent) installed on the leading edge of the door that when activated causes an operator closing a door to reverse direction of the door and prevents an operator from closing an open door, or (Exception: During the process of closing a door in response to a fire condition, commercial/industrial door operators (i.e. fire door operator systems in alarm) are not required to comply with this provision) b) A non-contact type sensor (photoelectric sensor or equivalent) that when activated causes an operator closing a door to reverse direction of the door and prevents an operator from closing an open door, or (Exception: During the process of closing a door in response to a fire condition, commercial/industrial door operators (i.e. fire door operator systems in alarm) are not required to comply with this provision) c) Any other device that provides entrapment protection equivalent to items (a) or (b).

UL 325 2010 Revision External Entrapment Protection - Classifications - Primary (Mandatory) External Entrapment Devices: a) A non-contact type sensor such as Monitored photo sensors (photo-eyes) b) A 2-wire or 4-wire Monitored electric sensing edge Secondary (Optional) External Entrapment Devices: a) A 2-wire non-monitored electric sensing edge b) A pneumatic safety edge Note: Primary external entrapment devices are mandatory for wiring types other than constant pressure to close and may be supplemented by secondary external entrapment devices. Secondary external entrapment devices cannot be used in lieu of primary devices

Example 1 Monitored Photo-Sensors Only Monitored Photo-Sensors (Photo-Eyes) Note: Attachment to terminal strip / PCB for illustration purposes only. Actual attachment recommendations will vary from manufacturer to manufacturer.

Example 2 4-Wire Monitored Electric Sensing Edge Only (white/black) (white) 4-Wire Monitored Electric Sensing Edge Note: Attachment to terminal strip / PCB for illustration purposes only. Actual attachment recommendations will vary from manufacturer to manufacturer.

Example 3 Monitored Photo-Sensors w/ 4-Wire Sensing Edge 4-Wire Monitored Electric Sensing Edge (Optional) Monitored Photo-Sensors (Photo-Eyes) (Mandatory) Note: Attachment to terminal strip / PCB for illustration purposes only. Actual attachment recommendations will vary from manufacturer to manufacturer.

Example 4 Monitored 4-Wire Sensing Edge w/ Photo-Sensors 4-Wire Monitored Electric Sensing Edge (Mandatory) Non-Monitored Photo-Sensors (Photo-Eyes) (Optional) Note: Attachment to terminal strip / PCB for illustration purposes only. Actual attachment recommendations will vary from manufacturer to manufacturer.

Example 5 Monitored Photo-Sensors w/ Non-Monitored Sensing Edge 2-Wire Non-Monitored Electric Sensing Edge or Pneumatic Sensing Edge (Optional) Monitored Photo-Sensors (Photo-Eyes) (Mandatory) Note: Attachment to terminal strip / PCB for illustration purposes only. Actual attachment recommendations will vary from manufacturer to manufacturer.

UL 325 2010 Revision External Entrapment Protection - Documentation - All door operator manufacturers are required to state within the installation manuals and/or user s guides which photo sensors and sensing edges are approved by UL for use with the operator An operator shall be provided with instructions in the instruction manual specifying the methods of installation, adjustment, and wiring of external controls or devices serving as required protection against entrapment The following instructions or the equivalent shall also be supplied where applicable: For operators utilizing a non-contact sensor 1) Instructions on the placement of non-contact sensors for each type of application shall be provided. For operators utilizing a contact sensor 1) One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading edge of a horizontal slide door 2) One or more contact sensors shall be located at the bottom edge of a vertically moving door

UL 325 2010 Revision Switches and Controls A switch shall be located or protected so that it shall not be normally exposed to mechanical damage during use If a three-button switch or control is provided with a commercial/industrial door operator (or system), one button shall be a stop button Note: Installation instructions shall indicate that controls shall be far enough from the door, or positioned such that the user is prevented from coming in contact with the door while operating the controls.

UL 325 2010 Revision Installation of Operator Exposed moving parts of an industrial door operator that is intended to be mounted more than 8 ft above the floor are not required to be guarded or enclosed if the operator is marked indicating minimum acceptable installation height If a industrial door operator is installed below 8 ft., the exposed moving parts must be guarded or enclosed Manufacturer will demonstrate and test appropriate protection/guarding when operator is installed below 8 ft. above the floor

UL 325 2010 Revision Installation of Operator Commercial/Industrial door operator (or system) A door or door operator shall be provided with a warning placard Note: All warning signs and placards must be installed where visible in the area of the door. An operator shall be provided with specific instructions describing any necessary adjustment of the control mechanism required for satisfactory operation of the operator. The instructions shall also indicate the need for periodic checking of any control mechanism The installation instructions for commercial/industrial door operators shall include information on the types and sizes of doors for which the operator is intended including the type of entrapment protection suitable for each size and type of door for which the operator is intended.

Warning Placard

The Installation Instructions shall include the following instructions or their equivalent: IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk of severe injury or death: 1) READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. 2) Install only on a properly operating and balanced door. A door that is operating improperly could cause severe injury. Have qualified service personnel make repairs to cables, spring assemblies, and other hardware before installing the operator. 3) Remove all pull ropes and remove, or make inoperative, all locks (unless mechanically and/or electrically interlocked to the power unit) that are connected to the door before installing the operator. 4) Install the door operator at least 8 feet or more above the floor if operator has exposed moving parts. UL 325 2010 Revision Installation Instruction Requirements 5) Do not connect the door operator to the source of power until instructed to do so. 6) Locate the control station: (a) within sight of the door, (b) at a minimum height of 5 feet so small children cannot reach it, and (c) away from all moving parts of the door. 7) Install the Entrapment Warning Placard next to the control station in a prominent location. 8) For products having a manual release, instruct the end user on the operation of the manual release.

UL 325 2010 Revision User Instruction Requirements The User Instructions shall include the following instructions or their equivalent: IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of severe injury or death: 1) READ AND FOLLOW ALL INSTRUCTIONS. 2) Never let children operate or play with door controls. Keep the remote control (where provided) away from children. 3) Personnel should keep away from a door in motion and keep the moving door in sight until it is completely closed or opened. NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR. 4) Test the door s safety features at least once a month. After adjusting either the force or the limit of travel, retest the door operator s safety features. Failure to adjust the operator properly may cause severe injury or death. 5) For products having a manual release, if possible, use the manual release only when the door is closed. Use caution when using this release when the door is open. Weak or broken springs may cause the door to fall rapidly, causing severe injury or death. 6) KEEP DOORS PROPERLY OPERATING AND BALANCED. See Door Manufacturer s Owner s Manual. An improperly operating or balanced door could cause severe injury or death. 7) Have trained door systems technician make repairs to cables, spring assemblies, and other hardware. 8) SAVE THESE INSTRUCTIONS.