OPUS20 LAN-Datalogger Future Inside

Similar documents
Lufft OPUS20 LAN-Datalogger. Future Inside. Measurement. Storage and Transfer. Representation and Evaluation

Abbeon Cal Inc. Ph: 800/ Fax: 805/

data logger DL200H DL200D DL200L

ECOLOG-NET LA8 and WA8 (wireless), 8 x 4..20mA signals

EasyLog Data Logger Series

EasyLog Data Logger Series

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Accessories, interfaces, sensors and complete solutions.

Medical Refrigerators

MR SERIES CARD LOGGERS

Measurement Solutions for Refrigeration Technology.

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

Constant climate chambers

Constant climate chambers

Monitoring system. testo 160 Monitoring system for the monitoring of temperature, humidity, light intensity, UV radiation and CO 2. concentration.

Specification for On-Line UPS Battery Monitoring and Data Management System

EL-USB-1-LCD Temperature Data Logger with LCD

Pocket CO2 Monitor & Data Logger SAN-0001

CEIA THS/PH21. series. High Performance Pharmaceutical Metal Detection Systems. Superior and Consistent Detection

Huminator II. Precision Humidity Generator. ww.testo.in

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

CEIA THS/PH21. series HIGH PERFORMANCE PHARMACEUTICAL METAL DETECTION SYSTEMS. Superior and Consistent Detection Enhanced Product Throughput Rate

Measurement Solutions for Refrigeration Technology.

Constant climate chambers

Constant climate chamber with humidity

SENSORS TRANSMITTERS. Process monitoring

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

ECOLOG Data Sheets Status May 2015

Constant climate chamber with ICH-compliant illumination

Dräger Pac 8500 Single-Gas Detector

EL-USB-1-LCD Temperature Data Logger with LCD

Specifications Minimum Typical Maximum Unit

Dräger Pac 6000 Single-Gas Detector

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Dräger Polytron 7000 Fixed gas detector

Air Quality Sensors. Particle Matter, CO 2, Humidity, Temperature and Dust Products. OEM Sensor Components for Air Quality and Environmental Control

Dräger Pac 8000 Single-Gas Detection Device

CONSTANT FILL LEVEL MONITORING AT COVESTRO AG

Digital, not analog: One manifold for all refrigeration systems.

Cold chain monitoring technologies. Facility monitoring

EL-USB-TC Thermocouple Data Logger with USB Interface

PR / MP I Laboratory / Medicine

PHOENIX L300i New Standards in Helium Leak Testing The next Generation

FITOCLIMA 600 & 1200 STABILITY

Room air quality sensors

Your competent partner for measuring and services.

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Constant climate chambers

THE FULL FORCED CONVECTION REFLOW SOLDERING SYSTEM SMT QUATTRO PEAK SERIES (FROM STO XLPLUS)

Constant climate chambers

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

Dew point set DS 400

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

STABILITY ICH. ICH Stability Tests

Dräger X-am 7000 Multi-Gas Detection

Sensors Transmitters. Pressure / Temperature / Humidity / Air velocity / Airflow / Air quality / Solar / Light. European Manufacturer

MIRADOR Real Time Monitoring

VD8. mode VD8. Digital Compact Vacuum Meters Data Loggers

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Dräger Pac 8500 Single-Gas Detection Device

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

KMF Environmental test chamber for constant climate

THE NEW GENERATION VACUUM PUMP SYSTEM SC

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

KANE-ALERT-CO 2 Monitor with Temperature

COMPLETELY AUTOMATED HYDROLYSIS

PROTÉGÉ ZM SINGLE GAS MONITOR

Dräger X-am 5000 Multi-Gas Detection

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Dräger Pac 6000 Single-Gas Detection Device

FITOCLIMA 600 & 1200 STABILITY

OO Measuring range from bar rel. OO Large selection of pressure sensors. OO Automatic sensor recognition

! WARNING! User Manual LogiCO2 -Scout. Important Safety Information! CO2 Concentration Levels (%) and Effects ENGLISH

Temperature Monitoring System. Specifications

Measurement and Control Technology

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Product overview. Alarm indicator, operator and display panels

ENERGY SAVING SEIBU GIKEN DST

Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY

portable gas analyser

A660 Air Conditioning Laboratory Unit

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

EL-OEM-3 OEM Packaged Voltage Data Logger

REAL TIME LABORATORY MONITORING SYSTEM

Tinytag Ultra Data Logger Manual

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Dräger X-am 5000 Multi-Gas Detection

Dräger X-am 2500 Multi-Gas Detection

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

ELMTEC. Kattreppeln Königslutter / /

CAN unit for Analog Sensors

Transcription:

OPUS20 LAN-Datalogger Future Inside a pa ssio n fo r pr ecis ion pa ssion po ur la préc is ion pasi sión por la pr ec isió ió n pa ssio ne per la pr ecis isio ione a Supplier of Lufft Products since 1946 123 Gray Avenue, Santa Barbara, CA 93101 Ph: 800/922.0977 Fax: 805/966.7659 www.abbeoninstruments.com sales@abbeon.com www.lufft.com

The world s toughest legal guidelines: 21 CFR Part 11 The pharmaceutical industry trusts in Lufft. Rule out Fatal Consequences

Today s industrial data acquisition generally takes place in real time. The conditions and process environments of measured values regarding room climate change slowly, but are, nevertheless, permanent. Therefore, modern data recording systems that are implemented in this industry have to be reliable like Lufft products. Our products feature the following characteristics: modular design, a flexible and expandable sensor archive, freely programmable representation of measured values, as well as a monitoring system that is precisely tailored to the respective requirements and reacts as quickly as possible to potential nonconformities by setting off an alarm. The performance and quality of the whole data acquisition system is determined by measurement. Each application requires the ideal sensor for the job, and for this reason we offer several sensors according to specification and area of application for identical measuring categories. While a customer, for example, implicitly requires sensors in a steel housing, another application might necessitate the need for a differential pressure sensor with display. Due to our experience in various projects we are not only able to recommend, when it comes to sensors, the best possible solution for each application to our customers, but we also possess a variety of alternatives so that each user can find the ideal product. Qualification completes the successful system implementation procedure; calibration ensures an error-free and long-term precise operation. In summary, the best solution is based on two conditions: the first of which is the complete information of the customer s requirements, the other being a flexible system representing the customer s demands. For more detailed information concerning our procedures and what measurements you can yield, please consult our technical description. At the same time we provide a long-term traceability of processes. Qualification and Calibration Data storage naturally takes place in the central computer instead of at its collection point in real time. What happens if the system crashes? In cases of maximum data security we have integrated data logger modules in the measurement chain. These are situ ated between the sensor Storage and Transfer and the central computer and represent a type of Hammock. If the central computer does not receive all the data, then the data can be read offline and transferred from the data loggers. Nowadays modern data logging systems are independent of measurement rates, or rather measurement clocks. The data loggers establish an average value per sensor according to the user s requirements. With particle sensors this is the total sum per time unit. Measurement Representation and Evaluation Representation and evaluation is carried out by the software s client/server structure, allowing users to access and obtain relevant data. For many pharmaceutical and Alarm clean room applications the most important link in the chain is the alarm. Ultimately, it is imperative to act immediately to any possible deviations and take appropriate action. It is essential, for example, that processes such as long-term stability tests or clean room production be put right straight away if an error in the process chain arises. In industry, data transfer is sent analogically to a computer in the network. Due to the technical connection with the IP Network, data recording sites each receive an IP address and are linked by means of existing network architecture. 5

Measurement OPUS20 Multiple Functions with Internal Sensors Functions THI 8120.00 THIP 8120.10 TCO 8120.20 Power supply battery Power supply USB Power supply LAN (POE) optional optional optional Measured data storage 3,200,000 3,200,000 3,200,000 Typical battery life > 1 year > 1 year > 1 year LC-display One-button operation 1-point calibration by user/operator C/ F switchable Optical/acoustical alarm Date/time Records Min/Max/Avg. SmartGraph 3 evaluation software Measurement Categories THI 8120.00 THIP 8120.10 TCO 8120.20 Temperature Air temperature Humidity Relative Humidity Absolute humidity Dew point temperature Air pressure Barometric air pressure Relative air pressure CO 2 Concentration CO 2 Concentration Function Table Software THI 8120.00 THIP 8120.10 TCO 8120.20 Graphical representation Numerical data (measured value display) Print function Export function for measured values (e.g. Excel) Gathered printouts of all measurement sites User administration Administration of up to 255 measuring devices THI THIP TCO 6

OPUS20 THI Temperature and rel. Humidity For high-precision temperature and humidity measurements Measurement Opus20 Temperature and Relative Humidity Order-No. Opus20 Temperature / rel. Humidity (neutral without Lufft-Logo 8120.00N) 8120.00 Opus20 Temperature / rel. Humidity POE (neutral without Lufft-Logo 8120.01N) 8120.01 Technical data Dimensions length. 166 mm, width 78 mm, depth 32mm Measurement rate 10/30s, 1/10/12/15/30min, 1/3/6/12/24h Construction plastic housing Operation life (battery) > 1 Year Data Storage 16 MB, 3,200,000 measured values LC-Display size 90x64 mm Weight approx. 250g Included in delivery PC-Windows Software SmartGraph 3 for graphical and numerical representation of measured values / instruction manual/ data cable / battery Interface USB, LAN Storage rate 1/10/12/15/30min, 1/3/6/12/24h Power supply 4 x LRG AA Mignon, USB, (POE opt.) Max. operation -20...50 C temperature Max. rel. humidity 0...95%r.h.<20g/m 3 (non condensing) Temperature Principle NTC Measurement range 20 50 C ±0,3 C (0...40 C), otherwise 0,5 C 0,1 C Rel. humidity Principle capacitive Measurement range 10...95%r.h. ±2%r.h., 0,5%r.h. Accessories 4 x LRG AA Mignon 8120.SV1 For climate monitoring in buildings and the control of all climate-sensitive production processes: in electronic data-processing centres, control cabinets, wind turbines, storage rooms and museums. The Opus20 runs on batteries or powered via USB. Alternatively, you have the possibility to power the device via POE (Power over Ethernet). The only LAN datalogger with built-in sensors and the highest precision 7

Measurement OPUS20 THIP Temperature, Rel. Humidity, Air Pressure Finally available: Lufft s precise weather station for interior applications an essential data collector for all calibration laboratories. OPUS20 THIP Temperature, Relative Humidity, Air Pressure Order-No. OPUS20 THIP Temperature / Rel. Humidity / Air Pressure (neutral without Lufft-Logo 8120.10N) 8120.10 OPUS20 THIP Temperature / Rel. Humidity / Air Pressure POE (neutral without Lufft-Logo 8120.11N) 8120.11 Technical data Dimensions length. 166 mm, width 78 mm, depth 32mm Measurement rate 10/30s, 1/10/12/15/30min, 1/3/6/12/24h Construction plastic housing Operation life (battery) > 1 Year Data Storage 16 MB, 3,200,000 measured values LC-Display size 90x64 mm Weight approx. 250g Included in delivery PC-Windows Software SmartGraph 3 for graphical and numerical representation of measured values / instruction manual/ data cable / battery Interface USB, LAN Storage rate 1/10/12/15/30min, 1/3/6/12/24h Power supply 4 x LRG AA Mignon, USB, (POE opt.) Max. operation -20...50 C temperature Max. rel. humidity 0...95%r.h.<20g/m 3 (non condensing) Max. altitude 10,000 m above sea level Temperature Principle NTC Measurement range 20 50 C ±0,3 C (0...40 C), otherwise 0,5 C 0,1 C Rel. humidity Principle capacitive Measurement range 10...95%r.h. ±2%r.h., 0,5%r.h., Air pressure Measurement range 300 1300 hpa abs. 700 1100mbar at 25 C ±0,5 hpa 0,1 hpa Accessories 4 x LRG AA Mignon 8120.SV1 For high-precision pressure measurements 8

Opus20 TCO Temperature, Rel. Humidity, CO 2 Measurement Opus20 TCO / Temperature / Relative Humidity / CO 2 Order-No. Opus20 TCO / Temperature / Rel. Humidity / CO 2 (neutral without Lufft-Logo 8120.20N) 8120.20 Opus20 TCO / Temperature / Rel. Humidity / CO 2 POE (neutral without Lufft-Logo 8120.21N) 8120.21 Technical data Dimensions length. 166 mm, width 78 mm, depth 32mm Measurement rate 10/30s, 1/10/12/15/30min, 1/3/6/12/24h Construction plastic housing Operation life (battery) > 1 Year Data Storage 16 MB, 3,200,000 measured values LC-Display size 90x64 mm Weight approx. 250g Included in delivery PC-Windows Software SmartGraph 3 for graphical and numerical representation of measured values / instruction manual/ data cable / battery Interface USB, LAN Storage rate 1/10/30min, 1/3/6/12/24h Power supply 4 x LRG AA Mignon, USB, (POE opt.) Max. operation -20...50 C temperature Max. rel. humidity 0...95%r.F.<20g/m 3 (non condensing) Max. altitude 10,000 m above sea level Temperature Principle NTC Measurement range 20 50 C ±0,3 C (0...40 C), otherwise 0,5 C 0,1 C Rel. Humidity Principle capacitive Measurement range 10...95%r.h. ±2%r.h., 0,5%r.h., CO 2 Principle NDIR Measurement range 0 5,000 ppm ± 50 ppm +3 measured values at 20 C and 1,013 mbar 1 ppm Long-term stability 20 ppm/a Accessories 4 x LRG AA Mignon 8120.SV1 The amount of carbon dioxide had been virtually constant at 280 ppm (particles per million) i.e 280 gas molecules per million air molecules the last ten thousand years. However in recent years, this measured value has been increasing rapidly at approx. 2 % per year. A high level of CO 2 in the air within a room causes headaches, tiredness and lack of concentration. The regulation on CO 2 concentration was established in order to evaluate IAQ (Indoor Air Quality). Normal atmospheric air in so-called clean air areas has a level of 360 ppm and approx. 500 ppm in urban areas. The limit of 1,000 ppm ( Pettenkofer Figure ) is still seen as being adequate indoor-air quality, which is especially important when regarding all meetings and conference rooms, as well as schools and open-plan offices. As a guideline for school rooms in the USA the limit of 1,000 ppm applies; for workplaces the occupational exposure limit is 5,000 ppm. For high-precision CO 2 measurements 9

Representation and Evaluation

SmartGraph 3 Software With SmartGraph 3 the gathering of measured data is simple and as intuitive as possible: An Opus20 datalogger is automatically recognised and added as a network device. In addition to its data-readout function, the software possesses a recording mode that enables parallel recording to be displayed on the computer. The data from any desired number of OPUS20 devices can be read out simultaneously. The zoom function allows for quick analysis of critical time periods. The exporting of measured data in csv format enables it to be imported into Excel. The device configuration can be printed out in order to check installation parameters. Alarm limits like the measured data are chronologically managed at various times so that when changes in alarm limits occur, they can be retraced. Automatic data readout of all measured data is supported. 11

Wherever measured data is transferred by means of LAN within industry, Lufft s OPUS20 datalogger family can be ideally applied everywhere! With OPUS20, each ethernet cabable datalogger can be provided with an IP address even in remot monitoring networks, where many dataloggers are in operation. We see LAN, in connection with professional industrial applications with the highest reliability, as being the best possible data transfer method as opposed to WLAN applications that do not provide 100% data security during data transfer. Furthermore, power can be supplied via LAN (PoE) with the built-in batteries operating as a UPS (uninterruptible power supply). For these reasons this device concept corresponds to our development philosophy Future Inside Measurement Storage and Transfer Representation and Evaluation Qualification and Calibration Alarm G. LUFFT Mess- und Regeltechnik GmbH Gutenbergstrasse 20 70736 Fellbach Postfach 4252 70719 Fellbach Supplier of Lufft Products since 1946 Tel. +49 (0)711-51822 - 0 Fax 123 +49 Gray (0)711 Avenue, - 51822 Santa - 41 Barbara, CA 93101 Ph: 800/922.0977 Fax: 805/966.7659 www.abbeoninstruments.com www.lufft.de sales@abbeon.com info@lufft.de