One giant leap for safety: AZM400.

Similar documents
Safety in system: Protection for man and machine Innovations 2016/2017

A magazine full of solutions. Machine tools

Packaging industry Food and Beverage Solutions

Datasheet - MZM 100 ST-SD2PREM-A

Datasheet - MZM 100 B ST2-SD2PREM-A

Datasheet - MZM 100 ST2-1P2PWREM-A

Datasheet - AZM 161SK-12/12RK-024

SensaGuard TM Integrated Latch Installation Instructions

Datasheet - AZM 161SK-12/12RK-024

Original operating instructions Safety switch with guard locking AC901S AC902S

Simply safe. Transponder-coded safety switch CET with guard locking

Safety Sensor Eden AS-i Machine safety - Jokab Safety products

A stack full of solutions Wood-processing

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170

Multifunctional Gate Box MGB. More than safety.

Datasheet - AZM ZRK 24 VAC/DC

Machine Guarding and Safety

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating Guide Safe Torque Off

ISIS SAFETY SYSTEM Installation guide

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018

Safety. Detection. Control. SAFETY INTERFACES. Safety Interfaces and Relays. Product catalogue. Issue 1

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Student Presentation May 3rd 2018

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Simply safe. Transponder-coded safety switch CET with guard locking

Magnetically Coded Non-contact Switch (MC2)

Original instructions Sense7-series Non-contact coded safety switch

SAFETY INTERFACES SAFETY INTERFACES AND RELAYS

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

Safe living, Safe working

PROTECT SRB 200EXi-1A

Functional Safety of Machinery Presented by Greg Richards Manufacturing in America 02/22-23/2017

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

Machine Protection Door

Operating Guide Safe Torque Off

SAFEMASTER STS. The key to more safety. Our experience. Your safety.

Basics of Safety Applications

SLC 220 E/R RFBS

Basics of Safety Applications

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

SMARTair SOLUTIONS GUIDE. Providing complete specifications utilising ABLOY SMARTair. Page 1

System solutions for every lift. Everywhere. Lift emergency EasyGate PRO and Lift1

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS

More than safety. Operating Instructions Safety Switch CET.-AS-...-CB-... (Multicode)

SENSOR SOLUTIONS FOR DOORS

High Performance Door Albany RP2000. ASSA ABLOY Entrance Systems

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

Bernstein product overview

SAFETY RELAY APPLICATION

Edition 8 From serial no Publ. no OM 5030NHD; Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL)

PROFIBUS-PA Display RID 261 PROFIBUS-PA

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

SAFETY SERVICE RISK EVALUATION

Bulletin 440N-Z 440N-S 440K 440G. Sipha Magnetically Coded Non Contact Switches

Machine Protection Door Albany RP300 / RP300 Wide / RP300 USD. ASSA ABLOY Entrance Systems

High performance door Albany RR3000 Series. ASSA ABLOY Entrance Systems

Safe area; Zone 1 and Zone 2

/ / 2018

FUNCTIONAL SAFETY INCREMENTAL ENCODERS MASTERING SPEED CONTROL

designed for rail 5000 Series

Non-contact, coded safety switches PSEN

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Edition 8, From serial no Publ. no OM 5030, Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL)

SENSOR SOLUTIONS FOR DOORS

Conformity Approvals Rated insulation voltage Ui

Module Features are-configurable, no module jumpers to set

G. MONDINI DOSATRICI-CONFEZIONATRICI AUTOMATICHE. Tray Sealer Trave-340

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Where Process Safety meets Machine Safety

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

Datasheet - TVS /B-M20

Machine Protection Door Albany RP300. ASSA ABLOY Entrance Systems

Not to be reproduced without the permission of Last date for receipt of BIS or used as a STANDARD comments is: 15 July 2012

First of all, what is a safety-related

Automation, Software und Informationstechnologie

LZR -WIDESCAN. Motion, Presence, and Safety Sensor for Industrial Doors (US version) DESCRIPTION ENGLISH

LPI Lightning Warning System - LWS MKIII

SIL725 Safety Annunciator

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

/ sicam SICAM Safety Full functionality for safety-critical applications Answers for infrastructure and cities.

Safety and Security: Can they live together?

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

Machine guarding. First Choice Solutions for Machine Guards.

Operating Manual MS220KA and MSR220KA

Water Safety Shut-Off Valve HON 790. Product information. serving the gas industry worldwide

Proservo NMS5- / NMS7-

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

PPA Michaël GROSSI - FSCE PR electronics

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

SOCH AUTOMATION AND POWER SOLUTION

Flopurge TS. Operation Manual

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

LIGHT CURTAINS. Measuring and switching light curtains for a wide variety of applications.

Functional Safety incremental encoders

Connection of CET4-AP to Siemens ET 200S

Transcription:

One giant leap for safety: AZM400. Holding force: Unlocking against lateral force: Mechanical life: Protection class: Dimensions: Supply voltage: Electrical connection: AZM400 10,000 N 300 N > 1,000,000 operations IP66 / IP67 157 x 78 x 47 mm 24 VDC -15% / +10% ST: Connector plug M12, 8-pole; ST2: Connector plug M12, 8-pole / M12, 5-pole ST: 1 diagnostic output, 2 safety outputs, all p-type; ST2: 2 diagnostic outputs, 2 safety outputs, all p-type; 3 LED's ISO 13849-1, IEC 61508 Outputs: Diagnostic and status display: Classification: - of the interlocking function: - of the guard locking function: Approvals: safety requirements. The Schmersal Group The privately-owned Schmersal Group has been developing and manufacturing products to enhance the safety at work for decades. The company was founded in 1945 and is represented by seven manufacturing sites on three continents and with its own companies and sales partners in more than 60 nations. In the demanding field of machine safety, the Schmersal Group is one of the international market and competence leaders. Based on a comprehensive product range, the company s approximately 2000 employees develop and design complete solutions for the safety of man and machine. Customers of the Schmersal Group include global players from mechanical engineering and plant manufacturing and machine users. They benefit from the comprehensive know-how of the company when it comes to the standard-compliant integration of safety technology in the production processes. Furthermore, Schmersal has special sector expertise in the application fields that demand high quality and special characteristics from safety switching systems. These include food production, the packaging industry, machine tool construction, lift engineering, heavy industry and the automotive industry. Against the backdrop of increasing numbers of standards and directives, tec.nicum offers a comprehensive range of safety services as part of the Schmersal Group services division: Certified functional safety engineers advise customers on selecting suitable safety equipment, CE compliance assessments and risk assessment, on a word-wide basis. > Bistable, motor-driven system > Holding force 10.000 N details Actuator Mounting set Electric manual release E Emergency exit T Industries Services Competences Safe switching and monitoring Guard door monitoring (Safety switches) Command devices with safety function Tactile safety devices Optoelectronic safety devices Elevators and Escalators Packaging Food Automotive Machine tools Heavy industry Application support CE conformity assessment Risk assessment Upgrading / Retrofit Technical planning and implementation Training courses Machine safety Automation Explosion protection Hygienic design > PL e / cat. 4 / SIL 3 for interlocking and guard locking function Individual coding, re-teaching enabled -I2 Individual coding -I1 Product ranges > Individually coded version with coding level High according to ISO 14119 > Two-channel input signal of the guard locking function > Operation on P/P- and P/N-switching outputs > High tolerance to door misalignment details AZM400Z-ST-1P2P AZM400Z-ST-1P2P-T AZM400Z-ST-I1-1P2P AZM400Z-ST-I1-1P2P-T AZM400Z-ST-I2-1P2P AZM400Z-ST-I2-1P2P-T AZM400Z-ST2-2P2P-E AZM400Z-ST2-2P2P-T-E AZM400Z-ST2-I1-2P2P-E AZM400Z-ST2-I1-2P2P-T-E AZM400Z-ST2-I2-2P2P-E AZM400Z-ST2-I2-2P2P-T-E code 103003590 103003593 103003732 103003840 103003733 103003841 103003588 103003591 103003724 103003835 103003725 103003836 AZM400-B1 MS-AZM400 103003508 103009179 Safe signal processing Safety relay components Safety controllers Safety bus systems > Up to two diagnostic outputs Automation Position detection Command and signalling devices > Emergency exit or manual release > Optional: electric manual release with auxiliary voltage > Assembly set for simple installation on 40 mm aluminium profiles www.schmersal.com Launch campaign: wisuell.de Standard coding 2 diagnostic outputs 2P2P 1 diagnostic output 1P2P 2 connector plugs ST2 1 connector plug ST > Release possible against lateral forces up to 300 N The new safety interlock for demanding applications. Precautions have been taken to assure accuracy of the information in this catalogue.typographic or pictorial errors that are brought to our attention will be corrected in subsequent issues. Use the QR code for details. 1.000 / L+W / 11.2015 / Teile-Nr. 103011494 / EN / Ausgabe 01 AZM400: Highest demands on

One giant leap for safety: AZM400. Holding force: Unlocking against lateral force: Mechanical life: Protection class: Dimensions: Supply voltage: Electrical connection: AZM400 10,000 N 300 N > 1,000,000 operations IP66 / IP67 157 x 78 x 47 mm 24 VDC -15% / +10% ST: Connector plug M12, 8-pole; ST2: Connector plug M12, 8-pole / M12, 5-pole ST: 1 diagnostic output, 2 safety outputs, all p-type; ST2: 2 diagnostic outputs, 2 safety outputs, all p-type; 3 LED's ISO 13849-1, IEC 61508 Outputs: Diagnostic and status display: Classification: - of the interlocking function: - of the guard locking function: Approvals: safety requirements. The Schmersal Group The privately-owned Schmersal Group has been developing and manufacturing products to enhance the safety at work for decades. The company was founded in 1945 and is represented by seven manufacturing sites on three continents and with its own companies and sales partners in more than 60 nations. In the demanding field of machine safety, the Schmersal Group is one of the international market and competence leaders. Based on a comprehensive product range, the company s approximately 2000 employees develop and design complete solutions for the safety of man and machine. Customers of the Schmersal Group include global players from mechanical engineering and plant manufacturing and machine users. They benefit from the comprehensive know-how of the company when it comes to the standard-compliant integration of safety technology in the production processes. Furthermore, Schmersal has special sector expertise in the application fields that demand high quality and special characteristics from safety switching systems. These include food production, the packaging industry, machine tool construction, lift engineering, heavy industry and the automotive industry. Against the backdrop of increasing numbers of standards and directives, tec.nicum offers a comprehensive range of safety services as part of the Schmersal Group services division: Certified functional safety engineers advise customers on selecting suitable safety equipment, CE compliance assessments and risk assessment, on a word-wide basis. > Bistable, motor-driven system > Holding force 10.000 N details Actuator Mounting set Electric manual release E Emergency exit T Industries Services Competences Safe switching and monitoring Guard door monitoring (Safety switches) Command devices with safety function Tactile safety devices Optoelectronic safety devices Elevators and Escalators Packaging Food Automotive Machine tools Heavy industry Application support CE conformity assessment Risk assessment Upgrading / Retrofit Technical planning and implementation Training courses Machine safety Automation Explosion protection Hygienic design > PL e / cat. 4 / SIL 3 for interlocking and guard locking function Individual coding, re-teaching enabled -I2 Individual coding -I1 Product ranges > Individually coded version with coding level High according to ISO 14119 > Two-channel input signal of the guard locking function > Operation on P/P- and P/N-switching outputs > High tolerance to door misalignment details AZM400Z-ST-1P2P AZM400Z-ST-1P2P-T AZM400Z-ST-I1-1P2P AZM400Z-ST-I1-1P2P-T AZM400Z-ST-I2-1P2P AZM400Z-ST-I2-1P2P-T AZM400Z-ST2-2P2P-E AZM400Z-ST2-2P2P-T-E AZM400Z-ST2-I1-2P2P-E AZM400Z-ST2-I1-2P2P-T-E AZM400Z-ST2-I2-2P2P-E AZM400Z-ST2-I2-2P2P-T-E code 103003590 103003593 103003732 103003840 103003733 103003841 103003588 103003591 103003724 103003835 103003725 103003836 AZM400-B1 MS-AZM400 103003508 103009179 Safe signal processing Safety relay components Safety controllers Safety bus systems > Up to two diagnostic outputs Automation Position detection Command and signalling devices > Emergency exit or manual release > Optional: electric manual release with auxiliary voltage > Assembly set for simple installation on 40 mm aluminium profiles www.schmersal.com Launch campaign: wisuell.de Standard coding 2 diagnostic outputs 2P2P 1 diagnostic output 1P2P 2 connector plugs ST2 1 connector plug ST > Release possible against lateral forces up to 300 N The new safety interlock for demanding applications. Precautions have been taken to assure accuracy of the information in this catalogue.typographic or pictorial errors that are brought to our attention will be corrected in subsequent issues. Use the QR code for details. 1.000 / L+W / 11.2015 / Teile-Nr. 103011494 / EN / Ausgabe 01 AZM400: Highest demands on

One giant leap for safety: AZM400. Holding force: Unlocking against lateral force: Mechanical life: Protection class: Dimensions: Supply voltage: Electrical connection: AZM400 10,000 N 300 N > 1,000,000 operations IP66 / IP67 157 x 78 x 47 mm 24 VDC -15% / +10% ST: Connector plug M12, 8-pole; ST2: Connector plug M12, 8-pole / M12, 5-pole ST: 1 diagnostic output, 2 safety outputs, all p-type; ST2: 2 diagnostic outputs, 2 safety outputs, all p-type; 3 LED's ISO 13849-1, IEC 61508 Outputs: Diagnostic and status display: Classification: - of the interlocking function: - of the guard locking function: Approvals: safety requirements. The Schmersal Group The privately-owned Schmersal Group has been developing and manufacturing products to enhance the safety at work for decades. The company was founded in 1945 and is represented by seven manufacturing sites on three continents and with its own companies and sales partners in more than 60 nations. In the demanding field of machine safety, the Schmersal Group is one of the international market and competence leaders. Based on a comprehensive product range, the company s approximately 2000 employees develop and design complete solutions for the safety of man and machine. Customers of the Schmersal Group include global players from mechanical engineering and plant manufacturing and machine users. They benefit from the comprehensive know-how of the company when it comes to the standard-compliant integration of safety technology in the production processes. Furthermore, Schmersal has special sector expertise in the application fields that demand high quality and special characteristics from safety switching systems. These include food production, the packaging industry, machine tool construction, lift engineering, heavy industry and the automotive industry. Against the backdrop of increasing numbers of standards and directives, tec.nicum offers a comprehensive range of safety services as part of the Schmersal Group services division: Certified functional safety engineers advise customers on selecting suitable safety equipment, CE compliance assessments and risk assessment, on a word-wide basis. > Bistable, motor-driven system > Holding force 10.000 N details Actuator Mounting set Electric manual release E Emergency exit T Industries Services Competences Safe switching and monitoring Guard door monitoring (Safety switches) Command devices with safety function Tactile safety devices Optoelectronic safety devices Elevators and Escalators Packaging Food Automotive Machine tools Heavy industry Application support CE conformity assessment Risk assessment Upgrading / Retrofit Technical planning and implementation Training courses Machine safety Automation Explosion protection Hygienic design > PL e / cat. 4 / SIL 3 for interlocking and guard locking function Individual coding, re-teaching enabled -I2 Individual coding -I1 Product ranges > Individually coded version with coding level High according to ISO 14119 > Two-channel input signal of the guard locking function > Operation on P/P- and P/N-switching outputs > High tolerance to door misalignment details AZM400Z-ST-1P2P AZM400Z-ST-1P2P-T AZM400Z-ST-I1-1P2P AZM400Z-ST-I1-1P2P-T AZM400Z-ST-I2-1P2P AZM400Z-ST-I2-1P2P-T AZM400Z-ST2-2P2P-E AZM400Z-ST2-2P2P-T-E AZM400Z-ST2-I1-2P2P-E AZM400Z-ST2-I1-2P2P-T-E AZM400Z-ST2-I2-2P2P-E AZM400Z-ST2-I2-2P2P-T-E code 103003590 103003593 103003732 103003840 103003733 103003841 103003588 103003591 103003724 103003835 103003725 103003836 AZM400-B1 MS-AZM400 103003508 103009179 Safe signal processing Safety relay components Safety controllers Safety bus systems > Up to two diagnostic outputs Automation Position detection Command and signalling devices > Emergency exit or manual release > Optional: electric manual release with auxiliary voltage > Assembly set for simple installation on 40 mm aluminium profiles www.schmersal.com Launch campaign: wisuell.de Standard coding 2 diagnostic outputs 2P2P 1 diagnostic output 1P2P 2 connector plugs ST2 1 connector plug ST > Release possible against lateral forces up to 300 N The new safety interlock for demanding applications. Precautions have been taken to assure accuracy of the information in this catalogue.typographic or pictorial errors that are brought to our attention will be corrected in subsequent issues. Use the QR code for details. 1.000 / L+W / 11.2015 / Teile-Nr. 103011494 / EN / Ausgabe 01 AZM400: Highest demands on

Function and operation Highest demands on safety with bistable operating principle The AZM400 enhances the Schmersal family of safety locking devices to include a safety solenoid interlock with bolt locking. This consists of a locking unit with sensor technology and a motor-driven locking bolt, along with an actuator that features an encoded RFID-tag and a locking hole with two permanent magnets in which the locking bolt engages. Only once the safety door is in the correct position the locking bolt can be ejected. As soon as the locking bolt has reached a sufficient depth in the locking hole of the actuator, it is enabled by the system and the protection device is deemed to be secure. The AZM400 solenoid interlock is a bistable system. In other words, the locking device remains in the last locked status in the event of a power failure. Safe operation is assured in any operating condition of the machine as even if the system is in a run-down movement and present a danger, the safety door remains securely closed if power has been cut-off. Fields of application Machine tools with heavy doors Safety doors in machine and plant construction Actuated and motorised safety doors Heavy safety doors with high manual forces Safety doors in front of run-down and dangerous movements Machine tools and tool centres

Holding force High holding force and unlocking against lateral force With a holding force of 10,000 N, the AZM400 solenoid interlock is particularly well suited for heavy doors. It is not uncommon for tension to build up in the doors due to sealing lips or misalignment of the safety door. To resolve this problem, the AZM400 enables unlocking against lateral forces of up to 300 N. Actuator misalignment and switching distance Unlocking against lateral force: 300 N The actuator can be moved on both sides from the X and Y direction. In this way, simple installation in applications with sliding guards or rotating protective equipment is made possible. Due to the high permissible actuator offset, it can also be used where large installation tolerances on safety doors are encountered. Actuator tolerance in X and Y direction: ± 4 mm Distance between actuator and solenoid interlock 1 7 mm with max. angle offset of 2 Actuator tolerances

Electric manual release Electric manual release and enhanced diagnosis As with most of the electronic switchgear from Schmersal, the basic version of AZM400 (-ST) is fitted with an 8-pole M12 connector. This version features a diagnostic output and two safety outputs. The functionally enhanced version of AZM400 (-ST2) is also fitted with a 5-pole M12 connector in addition to the 8-pole M12 connector. This version is distinguished by an additional diagnostic output as well as the means by which an electric auxiliary release device can be connected. The electric manual release of the functionally enhanced version of AZM400 (-ST2) can be realised by an additional auxiliary voltage supply. By connecting the auxiliary voltage supply, it is possible to release the device in the event of a power failure or if the main supply is switched-off. Two-channel input signal according to ISO 14119 By means of two-channel input signal, the AZM400 meets the highest demands in safety as prescribed by ISO 14119. In this way, the interlocking function and the guard locking function fulfils PL e / category 4 / SIL 3. The guard locking function is significant particularly for applications in which a hazardous situation could occur through unintended opening of the isolating guard system such as, for example, run-down movement causing a danger. The new type of input circuit for actuation of the guard locking function makes it possible to connect the AZM400 to all common safety control systems. These safety control systems can be equipped both with P/P and P/N outputs. To do this, no different versions of the AZM400 are necessary.

Coding Automatic teaching after the operating voltage is switched on Ten minute release block during the teach-in procedure for the replacement actuator Protection against defeating through individual coding If interlocking devices are tampered with, the machine is no longer operated in accordance with the manufacturers specifications. As a result, the operator could be exposed to a considerably higher risk. If tampering cannot be excluded by using modified or additional operating modes, the machine builder can only take one more measure, i.e. making the tampering of the interlocking device more difficult or impossible. (Excerpt from ISO 14119) In its basic version, the AZM400 accepts any suitable actuator. By integrating RFID technology in the safety sensors, the coding level high can be reached for the individually encoded versions in accordance with ISO 14119. Version -I1 only accepts an actuator for which the teach-in process was run upon initial activation. With the third version -I2, this teach-in process can be repeated as many times as necessary. A release block of ten minutes prevents a quick change of the actuator and protects the system further against manipulation. In this way, the user can choose the most suitable coding variant for the intended application as well as the desired degree of protection against tampering. Teaching actuators without additional tools For the individually encoded versions -I1 and -I2, the teach-in process for the actuator requires no tools at all. During initial start-up, the teach-in process starts automatically. Simply connect the holding device to the operating voltage and bring the actuator into the detection range. After about ten seconds, brief cyclic flashes indicate that the operating voltage is to be switched off. When the operating voltage is reactivated, the actuator must be brought into the detection range again in order for the generated actuator code to be activated.

The AZM400 in detail ➆ ➂ ➅ ➄ ➃ ➁ ➀ Key ➀ High protection against tampering thanks to encoded RFID sensor ➁ Motor-driven locking bolt ➂ M12 connector plug, 8-pole ➃ Fixing holes for M6 bolts ➄ ➅ Emergency exit lever ➆ LED display Detection of block run If the locking bolt does not reach the "locked" status at the first attempt, the AZM400 makes another autonomous attempt. Only after the second attempt has failed will the AZM400 report a fault. This reduces the number of error messages and protects the device and the machine against damage. Features LED display Smart diagnostic by means of 3-colour LED's Red LED: Fault Yellow LED: Device condition Green LED: Supply voltage Two connector version AZM400 (-ST2) version with additional M12 5-pole connector plug for connection of electric manual release and additional diagnostic output. For set-up and commissioning of the machine, the solenoid interlock can be released without power with the aid of a triangular key.

AZM400 Holding force: 10,000 N Unlocking against lateral force: 300 N Mechanical life: > 1,000,000 operations Protection class: IP66 / IP67 Dimensions: 157 x 78 x 47 mm Supply voltage: 24 VDC -15% / +10% Electrical connection: ST: Connector plug M12, 8-pole; ST2: Connector plug M12, 8-pole / M12, 5-pole Outputs: ST: 1 diagnostic output, 2 safety outputs, all p-type; ST2: 2 diagnostic outputs, 2 safety outputs, all p-type; Diagnostic and status display: 3 LED's Classification: - of the interlocking function: - of the guard locking function: Approvals: ISO 13849-1, IEC 61508 details 1 connector plug ST 2 connector plugs ST2 1 diagnostic output 1P2P 2 diagnostic outputs 2P2P Standard coding Individual coding -I1 Individual coding, re-teaching enabled -I2 Emergency exit T Electric manual release E details code AZM400Z-ST-1P2P 103003590 AZM400Z-ST-1P2P-T 103003593 AZM400Z-ST-I1-1P2P 103003732 AZM400Z-ST-I1-1P2P-T 103003840 AZM400Z-ST-I2-1P2P 103003733 AZM400Z-ST-I2-1P2P-T 103003841 AZM400Z-ST2-2P2P-E 103003588 AZM400Z-ST2-2P2P-T-E 103003591 AZM400Z-ST2-I1-2P2P-E 103003724 AZM400Z-ST2-I1-2P2P-T-E 103003835 AZM400Z-ST2-I2-2P2P-E 103003725 AZM400Z-ST2-I2-2P2P-T-E 103003836 Actuator AZM400-B1 103003508 Mounting set MS-AZM400 103009179

One giant leap for safety: AZM400. Holding force: Unlocking against lateral force: Mechanical life: Protection class: Dimensions: Supply voltage: Electrical connection: AZM400 10,000 N 300 N > 1,000,000 operations IP66 / IP67 157 x 78 x 47 mm 24 VDC -15% / +10% ST: Connector plug M12, 8-pole; ST2: Connector plug M12, 8-pole / M12, 5-pole ST: 1 diagnostic output, 2 safety outputs, all p-type; ST2: 2 diagnostic outputs, 2 safety outputs, all p-type; 3 LED's ISO 13849-1, IEC 61508 Outputs: Diagnostic and status display: Classification: - of the interlocking function: - of the guard locking function: Approvals: safety requirements. The Schmersal Group The privately-owned Schmersal Group has been developing and manufacturing products to enhance the safety at work for decades. The company was founded in 1945 and is represented by seven manufacturing sites on three continents and with its own companies and sales partners in more than 60 nations. In the demanding field of machine safety, the Schmersal Group is one of the international market and competence leaders. Based on a comprehensive product range, the company s approximately 2000 employees develop and design complete solutions for the safety of man and machine. Customers of the Schmersal Group include global players from mechanical engineering and plant manufacturing and machine users. They benefit from the comprehensive know-how of the company when it comes to the standard-compliant integration of safety technology in the production processes. Furthermore, Schmersal has special sector expertise in the application fields that demand high quality and special characteristics from safety switching systems. These include food production, the packaging industry, machine tool construction, lift engineering, heavy industry and the automotive industry. Against the backdrop of increasing numbers of standards and directives, tec.nicum offers a comprehensive range of safety services as part of the Schmersal Group services division: Certified functional safety engineers advise customers on selecting suitable safety equipment, CE compliance assessments and risk assessment, on a word-wide basis. > Bistable, motor-driven system > Holding force 10.000 N details Actuator Mounting set Electric manual release E Emergency exit T Industries Services Competences Safe switching and monitoring Guard door monitoring (Safety switches) Command devices with safety function Tactile safety devices Optoelectronic safety devices Elevators and Escalators Packaging Food Automotive Machine tools Heavy industry Application support CE conformity assessment Risk assessment Upgrading / Retrofit Technical planning and implementation Training courses Machine safety Automation Explosion protection Hygienic design > PL e / cat. 4 / SIL 3 for interlocking and guard locking function Individual coding, re-teaching enabled -I2 Individual coding -I1 Product ranges > Individually coded version with coding level High according to ISO 14119 > Two-channel input signal of the guard locking function > Operation on P/P- and P/N-switching outputs > High tolerance to door misalignment details AZM400Z-ST-1P2P AZM400Z-ST-1P2P-T AZM400Z-ST-I1-1P2P AZM400Z-ST-I1-1P2P-T AZM400Z-ST-I2-1P2P AZM400Z-ST-I2-1P2P-T AZM400Z-ST2-2P2P-E AZM400Z-ST2-2P2P-T-E AZM400Z-ST2-I1-2P2P-E AZM400Z-ST2-I1-2P2P-T-E AZM400Z-ST2-I2-2P2P-E AZM400Z-ST2-I2-2P2P-T-E code 103003590 103003593 103003732 103003840 103003733 103003841 103003588 103003591 103003724 103003835 103003725 103003836 AZM400-B1 MS-AZM400 103003508 103009179 Safe signal processing Safety relay components Safety controllers Safety bus systems > Up to two diagnostic outputs Automation Position detection Command and signalling devices > Emergency exit or manual release > Optional: electric manual release with auxiliary voltage > Assembly set for simple installation on 40 mm aluminium profiles www.schmersal.com Launch campaign: wisuell.de Standard coding 2 diagnostic outputs 2P2P 1 diagnostic output 1P2P 2 connector plugs ST2 1 connector plug ST > Release possible against lateral forces up to 300 N The new safety interlock for demanding applications. Precautions have been taken to assure accuracy of the information in this catalogue.typographic or pictorial errors that are brought to our attention will be corrected in subsequent issues. Use the QR code for details. 1.000 / L+W / 11.2015 / Teile-Nr. 103011494 / EN / Ausgabe 01 AZM400: Highest demands on