IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Similar documents
SOLAR CABLES. Electric cables for solar PV installations

PRODUCT CATALOGUE Norröna

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

High Performance LSZH Fire Resistant Cable

Flame Retardant Overall Screened Instrumentation Cables (multicore)

OIL & GAS INDUSTRY OTHER INDUSTRIES

Havells Fire Survival Cables

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

Total Fire Solutions. Includes BS 8519 and the updated BS :

Catalogue Power Cables

Traction Cable Radox 3 GKW

The Quality Connection. BETAflam Fire Resistant Safety Cables

Catalogue Telecommunication Cables INTRODUCCIÓN

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

FIRE RESISTANT CABLES

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

fire resistant cables

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Shipboard & Offshore Cables

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

THE TRUE FIRE SURVIVAL CABLE

Photovoltaic Cables EN H1Z2Z2-K

Caledonian Flame Retardant Coaxial Cables

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Tratos Railway Cables

Telecommunication Cables

Cable technology for highest safety requirements

Fire Resistant Cables

Caledonian fire Resistant signal & Data cables

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Multi-Core Fire Resistant Cable

DNVGL-CP-0401 Edition February 2016

Catalogue. Instrumentation & Control Cables

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

FIRE RESISTANT CABLES FP300

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

LSOH Wiring Cables. LSOH Conduit Wire (HO7Z-R) Low Voltage (450/750 V) Cable Approvals. Key Applications. Conductor. Insulation. Core Identification

LSOH Flexible Cables

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

BS /1000V XLPE Insulation LSZH Sheath Cables

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Caledonian Fire resistant Coaxial Cables

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

SAS Security and Alarm Safety Cables

Nuclear Power Plant LSZH Cable Overview

Flexible Power Cable DLO

SPECIAL ELECTRICAL AND OPTICAL CABLES

DNVGL-CP-0399 Edition March 2016

CABLES FOR ALARM AND SAFETY SYSTEMS

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

UNIKA Universal Cable Cable Specialist

Wires, Cables, Cords and Adhesive Tapes

Evolution of Cable Fire Safety Standards in Australia

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

CATEGORY 6A FTP RJ45 SOLUTION

CONNECTION SYSTEMS TRANSIT APPLICATIONS

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

(Notices) EUROPEAN COMMISSION

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

LV FIRE RESISTANT CABLES

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

Compact Module. Category 6A FTP Cabling System 1.1

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Cablosam Tapes for Fire-Resistant Cables

Lloyd s Register Type Approval System Test Specification Number 3

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

FIRE RESISTANT CABLES FP400

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Overmoulded Cable Assembly Selector Guide

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Introduction.

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

DNVGL-CP-0402 Edition February 2016

Duct Cable GYTS-144B1.3

More than Just a Cable Supplier

INSTRUCTION DE IS 23 SÉCURITÉ Rev. 2 SAFETY INSTRUCTION

Comtran Cable. Hub-LINK Cables for Transit Applications

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

S Low loss coax cables with foamed PE

OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW

QUALITY THROUGH EXPERIENCE

Transcription:

67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228. 2. Insulation Cross-linked polyethylene (XLPE) The standard identification of insulated conductors is the following: 3 1 x Natural 2 x Blue + Brown 3 G Blue + Brown + Green/yellow 3 x Brown + Black + Grey 3 x + 1 x Brown + Black + Grey + Blue (reduced cross-section) 4 G Brown + Black + Grey + Green/yellow 4 x Brown + Black + Grey + Blue 5 G Brown + Black + Grey + Blue + Green/yellow 3. Outer sheath Flexible PVC, black colour. APPLICATIONS Powerflex RV-K cable is suitable for all types of low voltage industrial-type connections, in urban grids, building installations, etc. Its high flexibility makes the installation process substantially easier and, as a result, is particularly suitable for use in difficult layouts. It can be buried or installed in a tube as well as outdoors without requiring additional protection. This cable can withstand damp conditions including total immersion in water (AD7).

POWERFLEX RV-K 68 CHARACTERISTICS Electrical performance LOW VOLTAGE 0,6/1kV Standard IEC 60502-1 - UNE 21123-2 Chemical performance Chemical & Oil resistance: Good. UV Resistant: UNE 211605. Water performance Water resistance: AD7 Immersion Approvals CE SEC BUREAU VERITAS AENOR SASO RoHS KEMA KEUR Other Meter by meter marking. Installation conditions Open Air. Buried. In conduit. Applications Thermal performance Maximum service temperature: 90ºC. Maximum short-circuit temperature: 250ºC (max. 5 s). Minimum service temperature: -40ºC (fixed and protected installations). Industrial use. Urban grids. Packaging Available in rolls (lengths of 100 m) and drums. Fire performance Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1. Reduced emission of halogens. Chlorine <15%. Mechanical performance Minimum bending radius: x5 cable diameter. Impact resistance: AG2 Medium severity.

49 TOPFLAT H05VVH6-F & H07VVH6-F 1 TOPFLAT H05VVH6-F & H07VVH6-F Flat cables for lifts, cranes, hoists and conveyor systems. 2 HD 359 EN 50214 DESIGN 1. Conductor Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228. 2. Insulation Flexible PVC. 3 The standard identification of insulated conductors is the following: 4 G Brown + Black + Grey + Green/yellow 6 or more conductors Black numbered+ Green/yellow 3. Outer sheath Flexible PVC outer sheath, black colour. The ripcord allows you to gently tear the outersheath allowing you to gently peel it away without damaging the screen. APPLICATIONS The Topflat H05VVH6-F & H07VVH6-F is a flat cable specially designed for cranes, lifts, hoists, drum reeling and conveyor systems. The hanging length of the cable can reach up to 35m and its pull out speed can reach up to 1.6 m/s (overlaying cables is not recommended when installing). This cable render is an example from this product range and does not neccesarily match the selected core size or number of cores.

TOPFLAT H05VVH6-F & H07VVH6-F 50 CHARACTERISTICS Electrical performance LOW VOLTAGE 300/500 V 450/750 V Chemical performance Chemical & Oil resistance: Acceptable. Standard HD 359 EN 50214 Water performance Water resistance: AD5 Jets. Approvals CE HAR AENOR SASO RoHS Thermal performance Maximum service temperature: 70ºC. Maximum short-circuit temperature: 160ºC (max. 5 s). Minimum service temperature: 0ºC. Fire performance Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1. Reduced emission of halogens. Chlorine <15%. Other Meter by meter marking. Installation conditions Open Air. Applications Industrial use. Mobile use. Hoists. Cranes. Elevators, lifts. Conveyors. Mechanical performance Minimum bending radius: x25 cable diameter. Impact resistance: AG2 Medium severity.

TOPFLEX VV-F H05VV-F 34 1 TOPFLEX VV-F H05VV-F Flexible cable for connecting small electrical appliances. EN 50525-2-11 / IEC 60227-5 DESIGN 2 1. Conductor Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228. 2. Insulation Flexible PVC. The standard identification of insulated conductors is the following: 2x 3G 4G 5G Brown + Blue Brown + Blue + Green/yellow Brown + Black + Grey + Green/yellow Brown + Black + Grey + Blue + Green/yellow 3. Outer sheath Flexible PVC. Standard colours are grey, white and black. Other colours available on request. 3 APPLICATIONS Topflex VV-F H05VV-F cable has been specially designed for connecting small home appliances such as vacuum cleaners, washing machines, refrigerators, etc. It is recommended for household installations and can also be used for light mobile services. These cables are also suitable for fixed applications in furniture, wall partitions, and in hollow spaces of prefabricated building parts. This cable render is an example from this product range and does not neccesarily match the selected core size or number of cores.

35 TOPFLEX VV-F H05VV-F CHARACTERISTICS Electrical performance LOW VOLTAGE 300/500 V Chemical performance Chemical & Oil resistance: Good. Standard EN 50525-2-11 / IEC 60227-5 Water performance Water resistance: AD5 Jets. Approvals CE SEC HAR AENOR SASO RoHS Thermal performance Maximum service temperature: 60ºC. Maximum short-circuit temperature: 150ºC (max. 5 s). Minimum service temperature: 5ºC. Fire performance Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1. Reduced emission of halogens. Chlorine <15%. Other Meter by meter marking. Installation conditions Open Air. In conduit. Applications Mobile use. Domestic use. Domestic appliances. Temporary site installations. Packaging Available in rolls (lengths of 50 and 100 m) and drums. Mechanical performance Minimum bending radius: 3 x cable Ø (Ø cable <12 mm2). 4 x cable Ø (Ø cable >12 mm2). Impact resistance: AG2 Medium severity.

25 TOPWELD H01N2-D 1 TOPWELD H01N2-D The special cable for welding. UNE-EN 50525-2-81 / IEC 60245 DESIGN 1. Conductor 2 Electrolytic copper, class D (extra-flexible), based on UNE-EN 50525-2-81. 2. Outer sheath Flexible rubber. Black colour. APPLICATIONS Topweld H01N2-D is a harmonized, flexible, rubber welding cable specially designed for transmitting high currents between the welding generator and the electrode. Its flexibility makes using the welding tool easier and also prevents knots from forming in the cable that could cause the internal conductor to break. It can also be used in automatic welding and machine tools, conveyor systems and production or assembly lines, for example in automobile assembly lines. This cable render is an example from this product range and does not neccesarily match the selected core size or number of cores.

TOPWELD H01N2-D 26 CHARACTERISTICS Electrical performance LOW VOLTAGE 100/100V Standard EN 50525-2-81 / IEC 60245 Approvals CE HAR AENOR SASO RoHS Chemical performance Chemical & Oil resistance: Excellent. Grease & mineral oils resistance: Excellent Water performance Water resistance: AD3 Sprays Other Meter by meter marking. Installation conditions Open Air. Thermal performance Maximum service temperature: 85ºC. Maximum short-circuit temperature: 250ºC (max. 5 s). Minimum service temperature: -20ºC. Fire performance Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1. Applications Welding. Industrial use. Mobile use. Robotics. Conveyors. Mechanical performance Minimum bending radius: x5 cable diameter. Impact resistance: AG2 Medium severity.

88 TOXFREE ZH ES05Z1-K & H07Z1-K (AS) 1 TOXFREE ZH ES05Z1-K & H07Z1-K (AS) Flexible and halogen free power cable for electrical panel wiring. UNE-EN 50525-3-31 / UNE 211002 / UL 1581 DESIGN 2 1. Conductor Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228. 2. Insulation Extra sliding low smoke zero halogen (LSZH) polyolefin insulation. The standard identification of insulated conductors is the following: Blue RAL 5015 Brown RAL 8003 Black RAL 9005 Red RAL 3000 Green/yellow RAL 1021 / RAL 6018 Grey RAL 7000 Dark Blue RAL 5003 White RAL 9010 Orange RAL 2003 Violet RAL 4005 Other colours available on request APPLICATIONS Toxfree ES05Z1-K & H07Z1-K is a LSZH safety cable. In the event of fire, it does not emit toxic gases, nor does it give off corrosive gases, avoiding any possible damage to people or electronic equipment. For these reasons it is highly recommended for use in public places such as: hospitals, schools, museums, airports, bus terminals, shopping malls, offices, laboratories, etc. This cable render is an example from this product range and does not neccesarily match the selected core size or number of cores.

TOXFREE ZH ES05Z1-K & H07Z1-K (AS) 89 CHARACTERISTICS Electrical performance LOW VOLTAGE 300/500 V 450/750 V UL 600 V Mechanical performance Minimum bending radius: x5 cable diameter. Standard UNE-EN 50525-3-31 / UNE 211002 / UL 1581 Chemical performance Chemical & Oil resistance: Acceptable. Approvals CE SEC HAR BUREAU VERITAS AENOR SASO RoHS Water performance Water resistance: AD3 Sprays. Other Meter by meter marking. (from 10mm2 onwards) Installation conditions In conduit. Thermal performance Maximum service temperature: 90ºC (UL 1581) / 70ºC (EN 50525-3-31). Maximum short-circuit temperature: 160ºC (max. 5 s). Minimum service temperature: -40ºC (fixed and protected installations). Fire performance Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1. Fire non-propagation based on UNE-EN 60332-3 and IEC 60332-3. LSZH (Low Smoke Zero Halogen) based on UNE-EN 60754-1 and IEC 60754-1. Low smoke emission based on UNE-EN 61034 and IEC 61034: Light transmittance > 60% Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2. Applications Domestic use. Electrical panel wiring. Public places. Packaging Small cross sections (from 0,75 mm2 to 6 mm2) are supplied in high-resistant boxes. Medium cross sections (from 10 mm2 to 35 mm2) are supplied in 100 m sealed coils. Greater cross sections (>35 mm2) are supplied in drums.

TOXFREE PLUS 331 ZH RZ1-K (AS+) 109 1 2 TOXFREE PLUS 331 ZH RZ1-K (AS+) LSZH and fire resistant power cable, for emergency circuits. 3 IEC 60502-1 / UNE 211025 DESIGN 4 1. Conductor Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228. 2/3. Insulation (2) Mica tape + (3) XLPE The standard identification of insulated conductors is the following: 1 x Natural 2x Blue + Brown 3 G Blue + Brown + Green/yellow 4 G Brown + Black + Grey + Green/yellow 5 G Brown + Black + Grey + Green/yellow + Blue 4. Outer sheath Low Smoke Zero Halogen (LSZH) polyolefin. Orange colour, non-toxic, fire retardant and fire resistant. APPLICATIONS Toxfree Plus RZ1-K (AS+) is a fire resistant cable, specially designed to ensure the power supply to emergency circuits in the event of fire. During a fire you need critical circuits to work for life safety (signaling lights, fume extractors, acustic alarms, water pumps, etc) and a secure plant shutdown. For this reason, its use is highly recommended in public places such as: hospitals, tunnels, offices, production plants, laboratories, hotels, etc. This cable render is an example from this product range and does not neccesarily match the selected core size or number of cores.

110 TOXFREE PLUS 331 ZH RZ1-K (AS+) CHARACTERISTICS Electrical performance LOW VOLTAGE 0,6/1kV Standard IEC 60502-1 / UNE 211025 Approvals CE RoHS Thermal performance Maximum service temperature: 90ºC. Maximum short-circuit temperature: 250ºC (max. 5 s). Minimum service temperature: -40ºC (fixed and protected installations). Mechanical performance Minimum bending radius: x5 cable diameter. Impact resistance: AG2 Medium severity. Chemical performance Chemical & Oil resistance: Acceptable. Water performance Water resistance: AD5 Jets. Fire performance Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1. Fire non-propagation based on UNE-EN 60332-3 and IEC 60332-3. Fire resistant: (PH120) mínimum 120 minutes at 840 ºC: Based on EN 50200 and IEC 60331-2 for Ø cable < 20 mm. Based on EN 50362 and IEC 60331-1 for Ø cable > 20 mm. 180 at 950ºC (cat C) category C,W & Z based on BS6387. Fire resistant 180 at 950ºC (cat C) category C,W & Z based on BS6387 (300/500V). LSZH (Low Smoke Zero Halogen) based on UNE-EN 60754-1 and IEC 60754-1. Low smoke emission based on UNE-EN 61034 and IEC 61034: Light transmittance > 60% Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2. Other Meter by meter marking. Installation conditions Open Air. Buried. In conduit. Applications Industrial use. Emergency circuits Public places.

112 TOXFREE ZH XTREM H07ZZ-F (AS) 1 TOXFREE ZH XTREM H07ZZ-F (AS) The extra-flexible LSZH rubber cable for mobile service. UNE-EN 50525-3-21 DESIGN 2 1. Conductor Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228. 2. Insulation LSZH Rubber. 3 The standard identification of insulated conductors is the following: 1 x Natural 2 x Brown + Blue 3 G Brown + Blue + Green/yellow 4 G Brown + Black + Grey + Green/yellow 5 G Brown + Black + Grey + Blue + Green/yellow 3. Outer sheath Low Smoke Zero Halogen (LSZH) rubber. Black colour. Fire retardant cable. APPLICATIONS Toxfree Xtrem H07ZZ-F is a flexible cable for mobile service, suitable for instalations where low smoke and halogen free fumes under fire conditions are required. Suitable for installations where the cable must withstand medium mechanical stress, for machines in industrial and agricultural workshops, for motors and transportable machines on construction sites, for windmills and for agricultural applications. This cable render is an example from this product range and does not neccesarily match the selected core size or number of cores.

TOXFREE ZH XTREM H07ZZ-F (AS) 113 CHARACTERISTICS Electrical performance LOW VOLTAGE 450/750 V Standard UNE-EN 50525-3-21 Approvals CE RoHS Mechanical performance Minimum bending radius: x3 cable diameter. Impact resistance: AG2 Medium severity. Chemical performance Chemical & Oil resistance: Excellent. Grease & mineral oils resistance: Excellent. Water performance Water resistance: AD7 Immersion. Thermal performance Maximum service temperature: 90ºC. Maximum short-circuit temperature: 250ºC (max. 5 s). Minimum service temperature: -40ºC (fixed and protected installations). Other Meter by meter marking. Installation conditions Open Air. In conduit. Fire performance Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1. Fire non-propagation based on UNE-EN 60332-3 and IEC 60332-3. Low smoke emission based on UNE-EN 61034 and IEC 61034: Light transmittance > 60% Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2. Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2. Applications Industrial use. Mobile use. Windmills.

91 TOXFREE ZH RZ1-K (AS) 1 TOXFREE ZH RZ1-K (AS) Flexible and halogen free (LSZH) power cable for public places. IEC 60502-1 / UNE 21123-4 2 DESIGN 1. Conductor Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228. 2. Insulation Cross-linked polyethylene (XLPE) The standard identification of insulated conductors is the following: 3 1 x Natural 2 x Blue + Brown 3 G Blue + Brown + Yellow/green 3 x Brown + Black + Grey 3 x + 1 x Brown + Black + Grey + Blue (reduced cross section) 4 G Brown + Black + Grey + Green/yellow 4 x Brown + Black + Grey + Blue 5 G Brown + Black + Grey + Blue + Green/yellow 6 G or more conductors: Black numbered + Green/yellow 3. Outer sheath Low Smoke Zero Halogen (LSZH) polyolefin. Green colour, non-toxic and fire retardant. APPLICATIONS Toxfree RZ1-K is a LSZH safety cable. In the event of fire, it does not emit toxic gases, nor does it give off corrosive gases, avoiding any possible damage to people or electronic equipment. For these reasons it is highly recommended for use in public places such as: hospitals, schools, museums, airports, bus terminals, shopping malls, offices, laboratories, etc.

TOXFREE ZH RZ1-K (AS) 92 CHARACTERISTICS Electrical performance LOW VOLTAGE 0,6/1kV Standard IEC 60502-1 / UNE 21123-4 Approvals CE SEC AENOR SASO RoHS KEMA KEUR Mechanical performance Minimum bending radius: x5 cable diameter. Impact resistance: AG2 Medium severity. Chemical performance Chemical & Oil resistance: Acceptable. UV Resistant: UNE 211605. Water performance Water resistance: AD5 Jets. Other Meter by meter marking. Thermal performance Maximum service temperature: 90ºC. Maximum short-circuit temperature: 250ºC (max. 5 s). Minimum service temperature: -40ºC (fixed and protected installations). Fire performance Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1. Fire non-propagation based on UNE-EN 60332-3 and IEC 60332-3. LSZH (Low Smoke Zero Halogen) based on UNE-EN 60754-1 and IEC 60754-1. Low smoke emission based on UNE-EN 61034 and IEC 61034: Light transmittance > 60% Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2. Installation conditions Open Air. Buried. In conduit. Applications Industrial use. Public places. Packaging Available in rolls (lengths of 100 m) and drums.

XTREM DN-F 22 1 XTREM DN-F Flexible 1.000 V rubber cable for industrial use. UNE 21150 DESIGN 2 1. Conductor Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228. 2. Insulation Rubber (type EPR). The standard identification of insulated conductors is the following: 3 1 x natural 2 x Brown + Blue 3 G Brown + Blue + Green/yellow 4 G Brown + Black + Grey + Green/yellow 5 G Brown + Black + Grey + Blue + Green/yellow 3. Outer sheath Flexible rubber. Black colour. APPLICATIONS Xtrem DN-F is a flexible rubber cable for mobile heavy duty. Suitable for installations in dry, damp or wet locations, outdoors, machines in industrial workshops, motors and transportable machines; on construction sites and for agricultural exploitations. Suitable for submerged installations (AD8) and for supplying power to low voltage appliances including electric motors and submersible pumps in deep water installations as well many other types of electrical equipment. This cable render is an example from this product range and does not neccesarily match the selected core size or number of cores.

23 XTREM DN-F CHARACTERISTICS Electrical performance LOW VOLTAGE 0,6/1kV Standard UNE 21150 Approvals CE RoHS Thermal performance Maximum service temperature: 90ºC. Maximum short-circuit temperature: 250ºC (max. 5 s). Minimum service temperature: -40ºC (fixed and protected installations) Fire performance Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1. Chemical performance Chemical & Oil resistance: Excellent. Grease & mineral oils resistance: Excellent. Water performance Water resistance: AD8 Submersion. Submersible pumps Deep wells Drinkable water Other Meter by meter marking. Installation conditions Open Air. Applications Industrial use. Mobile use. Windmills Mechanical performance Minimum bending radius: 3 x cable Ø (up to 12 mm2). 4 x cable Ø (from 12 mm2 onwards). Impact resistance: AG2 Medium severity.

19 XTREM H07RN-F XTREM H07RN-F 1 Flexible rubber cable, for industrial use. EN 50525-2-21 / IEC 60245-4 DESIGN 2 1. Conductor Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228. 2. Insulation Rubber (type EPR). The standard identification of insulated conductors is the following: 3 1 x natural 2 x Brown + Blue 3 G Brown + Blue + Green/Yellow 4 G Brown + Black + Grey + Green/Yellow 5 G Brown + Black + Grey + Blue + Green/Yellow 6 G or more Black numbered + Green/Yellow 3. Outer sheath Flexible rubber. Black colour. APPLICATIONS Xtrem H07RN-F rubber cables are designed to supply power to low voltage appliances including electric motors and submersible pumps in deep water installations as well as many other types of electrical equipment. Thanks to its extraordinary flexibility and mechanical strength, the Xtrem H07RN-F cable is ideal for power transmission in both fixed instalation or mobile service. The nominal voltage up to 1000 V thanks to the high dielectric properties of the insulation material (according to HD 516). This cable render is an example from this product range and does not neccesarily match the selected core size or number of cores.

XTREM H07RN-F 20 CHARACTERISTICS Electrical performance LOW VOLTAGE 450/750 V Standard EN 50525-2-21 / IEC 60245-4 Approvals CE SEC HAR AENOR DNV SASO RoHS Safe drinking water certificate Chemical performance Chemical & Oil resistance: Excellent. Grease & mineral oils resistance: Excellent. Water performance Water resistance: AD8 Submersion. Submersible pumps Deep wells Drinkable water Other Meter by meter marking. Installation conditions Open Air. Thermal performance Maximum service temperature: 90ºC. Maximum short-circuit temperature: 250ºC (max. 5 s). Minimum service temperature: -40ºC (fixed and protected installations) and -25ºC (mobile use) Applications Industrial use. Mobile use. Robotics. Windmills Temporary site installations. Fire performance Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1. Packaging Available in rolls of 100 m. and drums. Mechanical performance Minimum bending radius: 3 x cable Ø (up to 12 mm2). 4 x cable Ø (from 12 mm2 onwards). Impact resistance: AG2 Medium severity.