MB Multi-Speed Modular Blowers Cooling Capacity: 18,000-60,000 BTU/h Standard Features Multi-speed PSC blower motor Cooling or heat pump applications: upflow, downflow, and horizontal applications Control board includes a fan delay in cooling mode and is isolated from the air stream CAPF/CHPF coils are equipped with a check flowrater AHI certified; T listed Cabinet Features Painted, galvanized steel cabinet Blower section usable as an electric furnace Intended for use with cased evaporator coils (CAPF/CHPF) and condensing units or heat pumps Foil-faced insulation is glued in place and covers the entire blower case to reduce operating sound and cabinet condensation Bottom flanges formed inwardly for additional strength and to provide a good mounting surface for a cased-coil section to form a two-piece blower coil * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-ear Parts imited arranty, online registration must be completed within 60 days of installation. nline registration is not required in California or Québec. SS-MB www.goodmanmfg.com 7/11 Supersedes 5/11
Nomenclature MB VC 12 00 A A 1 1,2 3,4 5,6 7,8 9 10 11 Design Series lectrical MB Modular Blower 1 208-230/60/1 Motor Speed evisions Multi-Speed A First Series Circuit Breaker Airflow Delivered A No Circuit Breaker 08 800 CFM B Circuit Breaker 12 1200 CFM 16 1600 CFM Factory-installed lectric Heat 20 2000 CFM 00 No Heat 2 www.goodmanmfg.com SS-MB
Specifications Model CFM @ 0.3 SP (High-Med-ow) Voltage- Phase MCA¹ MD¹ Diam. Blower idth Motor HP MB0800AA-1 910-720-500 208/230-1 1.9 15 9 6 ¼ 72 MB1200AA-1 1,100-1,060-940 208/230-1 3 15 9 8 ⅓ 72 MB1600AA-1 1,580-1,380-1,000 208/230-1 3.8 15 10 8 ⅓ 82 MB2000AA-1 1,860-1,510-1,320 208/230-1 4.9 15 10 10 ½ 94 Ship eight (lbs) ¹ Minimum Circuit Ampacity and Maximum vercurrent Protection Device (MD) for blower without supplemental heat installed. efer to unit nameplate for these specifications with approved accessory heaters installed. lectric Heat Kit Data Blower HK-03* HK-05*/ -05C* HK-06* HK-08*/ -08C* lectric Heat Kit HK-10*/ -10C* MB0800AA-1A* X X X X X HK-15C* HK3-15* HK-20C* HK3-20* HK-21C* MB1200AA-1A* X X X X X X X X X X MB1600AA-1A* X X X X X X X X X X MB2000AA-1A* X X X X X X X X X X Single Point Kit ** Model HK-15C HK-20C HK-21C SP-01 X X X ** Must be installed along with any of the above compatible heat kits. This kit will fit any MB-MB blower as long as a compatible heat kit is installed in the unit. SS-MB www.goodmanmfg.com 3
Airflow Data Speed High Medium ow Static MB0800**-* SCFM MB1200**-* SCFM MB1600**-* SCFM MB2000**-* SCFM 0.1 1,240 1,500 1,800 2,160 0.2 1,170 1,460 1,740 2,080 0.3 1,120 1,360 1,680 1,990 0.4 1,060 1,280 1,610 1,890 0.5 980 1,200 1,520 1,790 0.6 900 1,110 1,430 1,690 0.1 900 1,380 1,540 1,730 0.2 850 1,320 1,490 1,670 0.3 790 1,270 1,450 1,590 0.4 740 1,200 1,400 1,520 0.5 680 1,140 1,350 1,420 0.6 605 1,040 1,280 1,320 0.1 650 1,170 1,130 1,520 0.2 590 1,130 1,100 1,450 0.3 540 1,080 1,070 1,360 0.4 500 1,020 1,030 1,290 0.5 430 950 990 1,200 0.6 330 830 930 1,090 xternal static is for blower @ 230 Volts, it does not include Coil, Air Filter or lectric heaters. 4 www.goodmanmfg.com SS-MB
Dimensions Side and Front Views D 5 C1/8 3 1/4 (3) KNCKUTS 1.125 1.375 1.750.875 KNCKUT (2 PACS) H 5 6 1/2 20" H D MB0800* 17½ 26 21 MB1200* 17½ 26 21 MB1600* 21 30 21 MB2000* 24½ 30 21 Top View 8 13 /16 8.840 11 11.029 13 3 /16 13.178 10 3 /16 10.159 11¼ 11.209 11¼ 11.209 16 ½ 16.500 20 1 /16 20.021 23 ½ 23.464 SMA MDIUM A 17½ 21 24½ SS-MB www.goodmanmfg.com 5
iring Diagrams iring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. arning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. 6 www.goodmanmfg.com SS-MB
iring Diagrams (cont.) M THMSTAT #18 A. 4 IS ITH CIN 3 IS ITHUT MB UNIT D N HIT T CNDNSIN UNIT 24V. CNNCTINS #18 A. 2 IS BU ow Voltage ow-voltage iring wiring Diagram diagram for for Cooling cooling unit Unit with with optional optional heat kit heat (10k kit and 10K below) and below M THMSTAT 2 #18 A. 4 I ITH CIN 3 I ITHUT MB UNIT D N UTD THMSTAT (PTINA) HIT CNTACT CI #18 A. 2 IS T CNDNSIN UNIT 24V. CNNCTINS #18 A. 2 IS BN BU ow Voltage ow-voltage iring wiring Diagram diagram for Cooling cooling unit Unit with with optional heat kit heat (15k kit and 15K above) and above iring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. arning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. SS-MB www.goodmanmfg.com 7
iring Diagrams (cont.) SSTM CMPSIT DIAAM MB0800 System Composite Diagram MB0800 10k and below 10k & B HAT PUMP C 2 B U H I T A N B HAT PUMP D T - 1 M THMSTAT C 2 #18 A. 5 IS S NT 3 B B UTD THMSTATS (PTINA) MAK N FA #18 A. 6 I NDD HN T IS USD SSTM CMPSIT DIAAM MB1200-2000System Composite Diagram MB1200-2000 above 10k ABV 10k M THMSTAT C 2 C 2 B U H I T A N B D T-1 T-2 #18 A. 5 IS S NT 3 B H B 1 1 3 4 S NT 2 MB UNIT D N HIT BU #18 A. 7 IS D N HIT BN BU MB UNIT High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. iring is subject to change. Always refer to the wiring diagram or the arning unit for the most up-to-date wiring. NTS 1) UTD THMSTAT (T-1) SHUD B TH FIST T CS AND TH FIST T PN. 2) IF UTD THMSTAT IS NT USD, TI HIT AND BN IS FM AI HAND TTH. 3) MV I HN USIN UTD T-STAT. #18 A. 7 I NDD HN (2) Ts A USD. #18 A. 7 I NDD HN (2) Ts A USD. NMNCATU T - UTD TMPATU (PTINA) MF - MAK N FA H - MNC HAT A (PTINA) C CDS - D - B - BU V - VIT B - BN - AN - HIT - N iring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wir oodman Manufacturing Company,.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 2011 oodman Manufacturing Company,.P. Houston, Texas Printed in the USA. 8 www.goodmanmfg.com SS-MB