Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

Similar documents
Cooling kit UTW-KCL*D. Installation instructions FR NL EN DE IT. (Compatible with high-flow circulation pump, code UTW-PHF*D)

User Instructions For TopTronic RS-30

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

USERS GUIDE. Electronic Timer, 7 day. LOGIC+ Combi, LOGIC Combi & LOGIC Combi E 24, 30, 35

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

INSTRUCTION FOR THE USER THC V E OIL BLU

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Operating instruction. Remote control station WCM-FS /

User Guide for EHE & EHE Programmable Room Thermostat

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

ECL Comfort 210 / 296 / 310

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

User instructions DHP-AT

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

DESIGN & TECHNICAL MANUAL

RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Boiler controllers User manual. Building Technologies HVAC Products

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

Operating instructions

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Operating Instructions

Installation and user manual

Panel Convector Heater User Instructions

Modulating clock thermostat

GENUS HE GENUS HE 24 GENUS HE 30 GENUS HE 38. User Manual. Condensing wall hung system boiler

COnDEnSInG BOIlERS TAU UNIT OIL USER parameters manual

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

Safety & Installation Instructions

ir-range 8G /03.15 Changes reserved.

RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Boiler controller User Manual. Building Technologies HVAC Products

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS

Operation Manual NOVA LIVE S

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

RVS13... RVS53... AVS75... AVS37... QAA75... QAA78... QAA55... Albatros2 Boiler controllers User Manual. Building Technologies HVAC Products

Control System THETA. Operating Instructions. Room control unit RSC and RSC-OT

BM Programming Module. For the heating engineer Installation instructions

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4

Operating Manual for professional installers. LMS Controller. 02/2011 Art. Nr

ROOM THERMOSTAT. with OpenTherm+ communication

Operation manual. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

User reference guide. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

User Manual THR870CUK Programmable Thermostat

Wireless Thermostat (WTS10) Keypad Operation Guide

QAA Room Unit for Boiler Control with OpenTherm Interface Basic Documentation. Siemens Building Technologies Landis & Staefa Division

STARBOX F02 Energy Manager

multimatic Operating instructions Operating instructions For the operator AT, BE (de), CH (de), DE VRC 700f/4 Publisher/manufacturer Vaillant GmbH

Climapro 2. Installation. wireless room thermostat without receiver.

QAW70. Room Unit. Building Technologies. for use with heating controllers

M116 / M450 USER AND MAINTENANCE MANUAL FOR MODULATING-CONTROL BOILER WITH GAS BURNER EQUIPPED FOR NATURAL GAS. Type : B23 ATLANTIC 2000

OPERATING INSTRUCTIONS

USER MANUAL. OPTIMA 312 ES960C circuit board

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

4 Wiring Brochure Wiring and

Quickheat 30 weather compensated boiler control

Condensing Boiler RS100 Controller Training Program

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

AUTO CM CM USER GUIDE

2nd circuit kit code

Operating instructions

Lyric T6 & T6R Smart Thermostat

Installation and servicing instructions

RVS46.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros 2 Zone controller User Manual. Building Technologies HVAC Products

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

WPM 2006 plus WPM 2006 R WPM 2007 plus WPM 2007 R

For the operator/for the heating engineer. Operating and Installation Manual VRC 430. Weather compensator VRC 430

DESIGN & TECHNICAL MANUAL

R. Boiler Energy Management System FW 200. Operating Instructions for the User (2010/05)

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

IE Instructions and warning book CRONO 7. Weekly digital chronothermostat

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

- Data Brochure tekmarnet 4 Thermostat 542e

Air Conditioner. user manual. imagine the possibilities. Wired Remote Control MWR-WH02. This manual is made with 100% recycled paper.

RADIO DRIVER. * _Rev.1* User guide. Wireless programmer. RADIO DRIVER zone RADIO DRIVER zones RADIO DRIVER zones

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

GA01HC-02. Service manual. Room Panel. Programme version 01a. Operating with GH07EA regulator for controlling electrode boilers

Basic Plus2 Room Thermostats Floor Heating

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

Type UDG, UCG, UTN, USG

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

WIRED REMOTE CONTROLLER

Watts Under Floor Multi-zone Controller User Manual

ALFEA. Commissioning & Services

CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E

3 Channel Multi-Purpose Programmer User Instructions

Operation Manual - PC-ARF - P IMPORTANT:

Operating instructions

Transcription:

Document n 1408-1 ~ 11/02/2010 Control Box FR EN NL DE IT Operation manual intended for professionals and end users To be saved for future consultation Fujitsu General (Euro) GmbH Werftstrasse 20 40549 Düsseldorf - Germany Subject to modifications without notice. Non contractual document.

Contents Instructions for user. 3 Instructions to be read before using the equipment.. 3 Safety instructions................... 3 Start-up..................... 3 Use....................... 3 Maintenance.................. 3 Precautions and warnings regarding your installation.. 3 Control system................. 3 The radiators.................. 3 Floor-heating systems............. 3 Domestic hot water (DHW)........... 3 User interface, room control unit (option) and room thermostat (option)............. 4 Quick start-up..................... 6 Programming example................ 7 Structure of the "End user" control menu....... 8 Parametering the setting............... 9 General..................... 9 Setting parameters............... 9 Information display.................. 11 Room thermostat Room control unit Heating circuit floor heating system or/and Control options Outdoor sensor Options depending on the system configurations Heating circuit radiators (or fan convectors) Control Box DHW kit DHW storage tank Boiler connection kit Heat pump figure 1 - Overall view of the configuration of a complete installation Complies with: - Low voltage directive 73/23/CEE, under standard EN 60335-1. - Electromagnetic compatibility Diretive 89/336/CEE - 2 - Operation manual "1408 - EN"

1 Instructions for user 1.1 Instructions to be read before using the equipment Please comply with the following instructions in order to avoid any risk of injury or inappropriate use of the appliance. 1.2 Safety instructions 1.2.1 Start-up Do not switch the appliance on until every fillings have been done. The installation must always be connected to the Earth and fitted with a protective circuit breaker. Do not modify the electricity supply. 1.2.2 Use Do not place any heat source under the control box, room control unit or room thermostat. 1.2.3 Maintenance Do not try to repair this appliance yourself. This appliance does not contain any components capable of being repaired by the user himself. Removing one or other of the covers can expose you to dangerous electrical voltages. In any case, switching off the current is not sufficient to protect you from any external electrical shocks (capacitors). Switch off the power supply if there are any abnormal noises, smells or smoke coming from the appliance and contact your installer. Switch off the power to the appliance before you clean it. Clean all the enamelled panels of the box with a dry or slightly damp soft cloth. 1.3 Precautions and warnings regarding your installation 1.3.1 Control system Your installer has carefully adjusted your installation. Do not modify setting parameters without his agreement. If in doubt, do not hesitate to contact him. The control system for your heating system is designed in flow temperature for the water based on the outdoor temperature (water control). The installation of a room thermostat (option) allows to improve operation of the regulation (the influence of the room temperature is taken into account). 1.3.2 The radiators To ensure the function of the regulation with room influence, it's necessary that the room in which the room thermostat is installed has no thermostatic valve or that they must be completely open. 1.3.3 Floor-heating systems New floor-heating systems require to be initially heated slowly to avoid any problems with cracking. Check with your installer that this initial heating procedure has indeed been performed before using your heating system freely. To be efficient, floor-heating systems do not need to be very hot and never should be. At most, the systems should be warm to the touch in cold weather. The great stability in a regulation system for floor-heating systems avoids sharp differences in temperature. However, this stability involves a reaction time of the order of several hours, (approx 6 hours). Any changes to the setting must be made slowly, leaving the installation time to react. Adjusting the system to exaggerated setting or in an untimely manner always results in significant temperature fluctuations during course of the day. Similarly if your dwelling has a floor-heating system, do not reduce the heating or switch it off if you will be absent for a short period. The reheating period is always quite long (approx 6 hours). 1.3.4 Domestic hot water (DHW) This function is designed as an option through the use of a DHW tank with electrical backup heating. When the DHW production is required, the heat pump adapts to this demand with higher priority. No space heating is produced while the domestic hot water is being prepared. The heat pump produces the domestic hot water, which is then additively heated, if required, by electrical backup heating inside the tank. To ensure a DHW setting over 45 C, the electrical backup heating or the boiler must be left on. The electrical backup heating enables anti-legionella cycles to be conducted efficiently. Operation manual "1408 - EN" - 3 -

1.4 User interface, room control unit (option) and room thermostat (option) 1 Auto 5 2 6 3 0 4 8 12 16 20 24 ESC OK 7 8 4 RESET 9 figure 2 - User interface of the control box 1 Auto 5 Auto 5 2 10 3 4 0 4 8 12 16 20 24 ESC OK 7 12 8 C 11 12 6 figure 3 - Room control unit (option) figure 4 - Room thermostat (option) - 4 - Operation manual "1408 - EN"

Ref. Function - Definitions 1 Selecting the DHW operating mode (Domestic hot water) On Marche If the installation is fitted with a DHW tank. On : Production of DHW according to the time program. Off : No domestic hot water heating, anti-frost function is active. Manual start button : Hold down the DHW key for 3 seconds (Switch from "reduced" to "nominal" until the next time the DHW timer switches over). Arrêt 2 Digital display Operating control, readout of the current temperature, of the heating mode and of any faults. View the settings. 3 Exit "ESC" Quit the menu. 4 Navigation and setting Selecting the menu. Off Setting parameters. Adjusting the ambient temperature setpoint. 5 Selecting the heating mode Heating operating according to the heating programme (Summer/winter mode switchover is automatic). Constant comfort temperature. Constant reduced temperature. Stand-by mode with anti-frost protection (Provided that the heat pump's electrical power supply is not interrupted). 6 Information display Various data (page 12). Reading error codes. Information concerning maintenance, special mode. 7 Confirm "OK" Input into the selected menu. Confirmation of the parameter settings. Confirmation of the adjustment to the comfort temperature setting. 8 Selecting cooling mode Auto Cooling operating according to the heating programme (Summer/winter mode switchover is automatic). 9 Reset (hold down the key for 3 sec) Reinitialising the parameters and cancelling error messages. Do not use during normal operation. 10 Digital display Operating control, readout of the current temperature, of the heating mode and of any faults. 11 Control knob Adjusting the ambient temperature setpoint. 12 Presence key Comfort / Reduced switchover. Operation manual "1408 - EN" - 5 -

1.5 Quick start-up Close the installation's main circuit breaker. Engage the start/stop switch on the control box. During the regulator initialisation phase, the display shows all the symbols and then "Data, update" and then "State heat pump". Select the "AUTO" heating mode. Select the DHW mode, if the installation is equipped with a DHW tank with electric back-up. Set the current date and time Press Appuyer OK sur OK _ Time Heure of etday date and date User Interface interface utilisateur Choose Sélectionner menu Time le menu and date Heure et date Press Appuyer OK sur OK Time Heure of etday date and date Hours Heures / / minutes minutes Select Sélectionner line : hours une des / minutes lignes : or Heure day / month minutes or ou year Jour / mois ou Année figure 5 - Selecting the heating mode AUTO and selecting the DHW operating mode Press Appuyer OK sur OK Time Heure of etday date and date Hours Heures // minutes Make Effectuer all the tous settings les réglages Appuyer sur OK Press OK pour valider to confirm chaque réglage each setting Press Revenir à l affichage heating de basemode en appuyant key to return sur la touche basic de display régime figure 6 - Setting the time and the date - 6 - Operation manual "1408 - EN"

1.6 Programming example Setting the time Touches Keys Display Exempleexample d affichage Description 1 AUTO Room Temperature setpoint ambiante 1 Affichage de base Basic display Si l affichage de base n est pas affiché If appuyer the basic sur display ESC pour is not y retourner. shown, press ESC to return to it 0 4 8 12 16 20 24 Press Appuyer OKsur OK. 2 AUTO Time Heure of etday date and date User Text3 Interface interface utilisateur 0 4 8 12 16 20 24 Tourner le bouton jusqu au menu Turn Heurethe etknob, date choose menu : Time and date Press Appuyer OK sur to confirm OK pour confirmer. 3 AUTO Time Heure of et day date and date Hours Heures / minutes / 0 4 8 12 16 20 24 Tourner le bouton jusqu à la ligne 1 Turn the knob, select line 1 : Heures / minutes Hours / minutes Press Appuyer OK sur to confirm OK pour confirmer. 4 AUTO Time Heure of et day date and date Hours Heures / minutes / 0 4 8 12 16 20 24 L affichage de l heure clignote The hour display flashes Tourner le bouton pour régler l heure. Turn the knob to set the time Press Appuyer OKsur OK. 5 AUTO Heure et date Time of day and date Hours Heures / minutes / 0 4 8 12 16 20 24 L affichage des minutes clignote The minutes display flashes Tourner le bouton Turn pour the régler knob les minutes. to set the minutes Press Appuyer OKsur OK. 6 AUTO Heure et date Time of day and date Hours Heures / minutes / 0 4 8 12 16 20 24 The Les réglages setting are sont recorded enregistrés Tourner le bouton pour effectuer Turn d autres the réglages. knob to make other settings ou or Press Revenir heating à l affichage mode key de base to enreturn appuyant to basic sur ladisplay touche de régime. figure 7 - Programming example Operation manual "1408 - EN" - 7 -

1.7 Structure of the "End user" control menu Basic display Brief press End user Commissioning Engineer OEM Time of day and date Hours / minutes Day / Month Year 1 2 3 Hours Minutes 1...24 h 0...60 min Operator section Language 20 English, German... Time prog heating circuit 1 Time prog heating circuit 2 Time program 4/DHW Pre-selection 1st phase on 1st phase off 2nd phase on 2nd phase off 3rd phase on 3rd phase off Default values 500 501 502 503 504 505 506 516 Mon-Sun Mon-Fri Sat-Sun Monday Tuesday Sunday Holidays heating circuit 1 Holidays heating circuit 2 Pre-selection 1st phase on 1st phase off Operation level 641 642 643 648 Period 1 Period 2... Period 8 Heating circuit 1 Heating circuit 2 Comfort setpoint 710 Reduced setpoint 712 Frost protect. setpoint 714 Reduced temp... 35 C Temp. frost protect... comfort 4 C... reduced temp. Domestic hot water Nominal setpoint 1610 Reduced temp... 65 C Fault Reset HP 6711 No, Yes Service/special operation Emergency operation7141 Off, On Diagnostics heat generation Diagnostics consumers Return temp HP 8410 Flow temp HP 8412 Compressor modulation 8413 Outdside temp. 8700 Reset outside temp min8702 8701 Reset outside temp max 8702...... Relay output QX7 9037 Off, On figure 8 - Structure of the "End user" control menu - 8 - Operation manual "1408 - EN"

1.8 Parametering the setting 1.8.1 General Only the parameters accessible to level : End user. Are described in this section. The parameters accessible at levels : Commissioning level. Engineer level. are described in this section reserved for these professional specialists. Do not make any modifications to these parameters without advice from these professional specialists. 1.8.2 Setting parameters With the screen on basic display. Press OK. Once in "End user" level Scroll the menu list. Choose the desired menu. Scroll the function lines. Choose the desired line. Adjust the parameter. Check the setting by pressing OK. To return the menu, press ESC. If no setting is made for 8 minutes, the screen returns automatically to the basic display. Basic display OK Brief press End user OK OK OK Time of day and date Hours / minutes 1 Hour 1...24 h Operator section Day / Month 2 Minutes 0...60 min Time prog heating circuit 1 Year 3... Line Function Setting range or display Setting increment Basic setting Date and time 1 Hours / Minutes 00:00... 23:59 1 2 Day / Month 01.01... 31.12 1 3 Year 1900... 2099 1 Operator section 20 Language English, Français, Italiano, Nederlands English Heating time programme, circuit 1 500 Pre-selection (Day / Week) Mon-Sun Mon-Fri Sat-Sun Monday Tuesday Mon-Sun 501 1 st phase On (start) 00:00... : 10 min 6:00 502 1 st phase Off (end) 00:00... : 10 min 22:00 503 2 nd phase On (start) 00:00... : 10 min : 504 2 nd phase Off (end) 00:00... : 10 min : 505 3 rd phase On (start) 00:00... : 10 min : 506 3 rd phase Off (end) 00:00... : 10 min : 516 Default values, Circuit 1 No, Yes No Yes + OK : The default values memorised in the regulator replace and cancel the customised heating programmes. Your customised settings are therefore lost. Operation manual "1408 - EN" - 9 -

Line Function Setting range or display Setting increment Basic setting Time programme 4 / DHW If the installation is fitted with a DHW tank. (Only with the DHW kit option). 560 Pre-selection (Day / Week) Mon-Sun Mon-Fri Sat-Sun Monday Tuesday Mon-Sun 561 1 st phase On (start) 00:00... : 10 min 00:00 562 1 st phase Off (end) 00:00... : 10 min 05:00 563 2 nd phase On (start) 00:00... : 10 min : 564 2 nd phase Off (end) 00:00... : 10 min : 565 3 rd phase On (start) 00:00... : 10 min : 566 3 rd phase Off (end) 00:00... : 10 min : 576 Default values No, Yes No Yes + OK : The default values memorised in the regulator replace and cancel the customised heating programmes. Your customised settings are therefore lost. Time programme 5 / Cooling 600 Pre-selection (Day / Week) Mon-Sun Mon-Fri Sat-Sun Monday Tuesday Mon-Sun 601 1 st phase On (start) 00:00... : 10 min 8:00 602 1 st phase Off (end) 00:00... : 10 min 20:00 603 2 nd phase On (start) 00:00... : 10 min : 604 2 nd phase Off (end) 00:00... : 10 min : 605 3 rd phase On (start) 00:00... : 10 min : 606 3 rd phase Off (end) 00:00... : 10 min : 616 Default values No, Yes No Holidays, heating circuit 1 Yes + OK : The default values memorised in the regulator replace and cancel the customised heating programmes. Your customised settings are therefore lost. 641 Preselection Period 1 to 8 Period 1 642 Start (Day / Month) 01.01... 31.12 1 643 End (Day / Month) 01.01... 31.12 1 648 Operating level (during the holidays) Frost protection, Reduced Frost protection Heating, circuit 1 710 Comfort heating setpoint from reduced setpoint to 35 C 0,5 C 20 C 712 Reduced setpoint from frost protection setpoint to comfort setpoint 714 Frost protection setpoint from 4 C to reduced setpoint 0,5 C 18 C 0,5 C 8 C Cooling circuit 1 901 Operating mode Off, Automatic Off 902 Comfort cooling setpoint 17... 40 C 0,5 C 24 C 907 Release 24h/day, Time program HC, Time program 5 / Cooling Time program 5 If the installation is fitted with a DHW tank, set the parameter 907 to " Time program 5 / Cooling" (In order to activate cooling only during the day and leave the DHW system to operate during the night). - 10 - Operation manual "1408 - EN"

Line Function Setting range or display Setting increment Basic setting Domestic Hot Water (Only with the DHW kit option) 1610 Nominal setpoint Reduced setting (line 1612) to 65 C 1 50 C The backup electrical system is required to reach this level. 1612 Reduced setpoint 8 C... to Nominal setpoint (line 1610) 1 25 C Swimming pool (Only with swimming pool kit option) 2056 Setpoint source heating 8... 35 C 22 C Fault 6711 Reset HP No, Yes No Service / Special operation 7141 Emergency operation Off, On Off Off : The heat pump does not use the boiler connection when a fault occurs (error 370). On : The heat pump uses the boiler connection when a fault occurs (error 370). In the "On" position, the energy costs can be onerous if the error is not eliminated. Diagnostics heat generation 8410 Return temp HP 0... 140 C Setpoint (return) HP 0... 140 C 8412 Flow temp HP 0... 140 C Setpoint (flow) HP 0... 140 C 8413 Compressor modulation 0... 100% Diagnostics consumers 8700 Outdside temperature -50... 50 C 8701 Outside temp min Reset? (No, Yes) 8702 Outside temp max Reset? (No, Yes) -50... 50 C -50... 50 C 8740 Room temperature 1 0... 50 C 20 C Room setpoint 1 4... 35 C 20 C 8743 Flow temperature 1 0... 140 C 50 C Flow temperature setpoint 1 0... 140 C 50 C 8756 Flow temp cooling 1 0... 140 C 0 Flow temp setpoint cooling 1 0... 140 C 0 8830 DHW (domestic hot water) temperature 0... 140 C DHW temperature setpoint 5... 80 C 50 C Operation manual "1408 - EN" - 11 -

1.9 Information display Various data can be displayed by pressing the info button. Depending on the type of unit, configuration and operating state, some of the info lines listed below may not appear. Error messages : The display shows the "Bell" symbol. Consult your heating technician. Service messages ; Special mode messages : The display shows the "Key" symbol. Consult your heating technician. Various data (see below). Designation Line Floor drying current setpoint. - Current drying day. - Terminated drying days. - State heat pump. 8006 State supplementary source. 8022 State DHW (domestic hot water). 8003 State heating circuit 1. 8000 State cooling circuit 1. 8004 Outdoor temperature. 8700 Room temperature 1. Room setpoint 1. 8740 Flow temperature 1. Flow temperature setpoint1. 8743 DHW (domestic hot water) temperature. 8830 Heat pump return temperature. Setpoint (return) HP. 8410 Heat pump flow temperature. Setpoint (flow) HP. 8412 This appliance is marked with this symbol. This means that electrical and electronic products shall not be mixed with general household waste. European Community countries(*), Norway, Iceland and Liechtenstein should have a dedicated collection system for these products. Do not try to dismantle the system yourself as this could have harmful effects on your health and on the environment. The dismantling and treatment of refrigerant, oil and other parts must be done by a qualified installer in accordance with relevant local and national regulations. This appliance must be treated at a specialized treatment facility for re-use, recycling and other forms of recovery and shall not be disposed of in the municipal waste stream. Please contact the installer or local authority for more information. * subject to the national law of each member state - 12 - Operation manual "1408 - EN"