DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Similar documents
DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU / h 11,900BTU / h 17,500BTU / h 24,200BTU / h

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL. Wall Mounted Type ON/OFF T-Series HSU-07HUN103/R2-P WARNING. Haier Group Version V1 Date

TECHNICAL DATA & SERVICE MANUAL

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

Destination Europe WARNING

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

TECHNICAL & SERVICE MANUAL SAP K181A + SAP C181A

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL MULTI-SPLIT SYSTEM AIR CONDITIONER

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

DESIGN & TECHNICAL MANUAL

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K303A + SAP C303A FILE NO. REFERENCE NO. SM Destination: Australia

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

Air Conditioner CONTENTS

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

TABLE OF CONTENTS. Air Conditioner

CU-3E23CBPG, CU- 4E27CBPG,

MAC N-407 Air-Cooled Chiller

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

YC ON-OFF SERIES. Service Manual

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL

MACH N-407 Heat Pump Air-Cooled Chiller

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

TABLE OF CONTENTS. Air Conditioner CS-MRE12MKE

Part 3 Troubleshooting

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

SERVICE MANUAL. Wall Mounted Type DC Inverter WARNING. Haier Group Version V1 Date

DESIGN & TECHNICAL MANUAL

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K301AH + SAP C301AH FILE NO. SAP K301AH SAP C301AH REFERENCE NO.

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

MAC-120HE-03 Air-Cooled Chiller

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

Room Air Conditioner CONTENTS CS-E9BKP CU-E9BKP5 CS-E12BKP CU-E12BKP5. Order No: MAC C2

DESIGN & TECHNICAL MANUAL

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL. Inverter Wall Mounted Single Split. MODELS Cooling Only. Heatpump SM-5WM-Y-NA-B1

CS-E18NKUA CS-E24NKUA CU-E18NKUA CU-E24NKUA TABLE OF CONTENTS WARNING

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

AIR-CONDITIONER SERVICE MANUAL SPLIT TYPE R410A OUTDOOR UNIT

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Installation Instructions

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SERVICE MANUAL. Wall Mounted Type DC Inverter WARNING. Haier Group Version V1 Date

13 SEER CONDENSING UNITS

Operating Instructions Air Conditioner


16 SEER TWO-STAGE AIR CONDITIONERS

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

Transcription:

TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU Product Code No. 1 852 361 27 1 852 361 28 1 852 361 29 CU-3KE19NBU < Applicable Indoor Units > Wall mounted type CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU Semi-concealed type CS-MKE9NB4U & CZ-18BT1U CS-MKE12NB4U & CZ-18BT1U CS-KE12NB4UW & CZ-18BT1U CU-4KE24NBU IMPORTANT CU-4KE31NBU These air conditioners employ new refrigerant R0A. Pay special attention when servicing the unit. REFERENCE NO. SM700878

SAFETY PRECAUTIONS Before doing repair work, please read the " SAFETY PRECAUTIONS" carefully and fully understand them. The precautionary items here are divided into " Warning" and " Caution" items. Items in particular which may cause death or serious injury to the service personnel if the work is not performed correctly, are included in the " Warning" table. However, even precautionary items identified as " Caution" also have the potential for serious consequences if not performed correctly. Important safety precautions are described for all items in both categories. Be sure to carefully follow all of them. Symbol Indication : This symbol indicates items to which we need to pay attention. In this triangle, a definite precautionary item is described. : This symbol indicates the item to be prohibited. In or close to this circle, a prohibited item is described. : This symbol indicates the items requiring special attention or instruction. In or close to this circle, a prohibited item is described. After doing repair work, perform a test run to confirm that there are no abnormalities. At the same time, explain the precautions in use to the user. Warning Before performing an overhaul, disconnect the power plug or power cable from the unit. Performing the work with the power supplied to the unit, may cause an electric shock. When repair work or circuit inspection that requires power supply for the air conditioner, is to be performed, do not touch the charging section. Doing so may cause an electric shock. Prohibit For the step-up capacitor attached to the electric section, perform the repair work after sufficiently discharging it. Insufficient capacitor discharge may cause an electric shock. Do not perform repair work on the electric sections with wet hands. Doing so may cause an electric shock. Do not start or stop the air conditioner by means of connecting or disconnecting the power plug. Doing so may cause an electric shock or fire. When conducting repair work only use components included in the parts list for the corresponding unit and perform the work with the appropriate tools. Incorrect or poor repair work may cause an electric shock or fire. Never modify the unit. Doing so may cause an electric shock or fire. Perform all electric work according to local applicable regulations related to electrical equipment or interior wiring regulation and make sure to use the exclusive circuit. Insufficient capacity to the electric circuit or defective arrangement results may cause an electric shock or fire. Prohibit Prohibit Prohibit Make sure to replace any power cable or lead wire showing any signs of scratch or deterioration. Failure to do so may cause an electric shock, overheating or fire. Make sure that there is no dust on or slack in the power plug and insert fully into the socket. Dust or incomplete connections may cause an electric shock or fire. Do not damage or process the power cord, as it may cause an electric shock or fire. Prohibit For the wiring between the indoor unit and outdoor unit, securely fix the specified cable onto the terminal plate. Poorly fixed wiring may cause a heat or fire. After connecting the wiring between the indoor unit and outdoor unit, attach the terminal cover securely. Incomplete attachment of the terminal cover may cause overheating or fire. 2

Warning If refrigerant gas blows off during the work, do not touch the refrigerant gas as it may cause frostbite. Prohibit If refrigerant gas leaks during the work, ventilate the room. If refrigerant gas catches fire, harmful gas may be generated. Do not mix any gas other than the specified refrigerant gas in the refrigerating cycle. If air or other contaminants mix with the gas, pressure will become extremely high in the refrigerating cycle, which may cause a unit breakdown." When the welded section of the compressor intake or discharge pipe is to be disconnected, perform it in a well-ventilated place after sufficiently recovering the refrigerant gas. Any residue gas may jet out refrigerant or refrigerating machine oil, which may cause an injury. Prohibit When the work is to be performed in a high place (About 2 meters or more), make sure to wear a safety helmet, gloves and safety belt. Insufficient safety gear may cause a serious injury in case of a fall. When the unit is to be relocated, confirm that the new installation location has sufficient strength for the weight of the unit. Insufficient strength of the installation location and incomplete installation work may cause an injury due to the unit falling. When the remote controller batteries are replaced, dispose of the old batteries out of the reach of children. If a child swallows a battery, make sure that the child gets immediate medical attention. Caution Do not wash the air conditioner with water, as this may cause an electric shock or fire. Prohibit For the repair work in places with high humidity or moisture, make sure to ground the unit. Failure to do so may cause an electric shock. Confirm that the component attachment position, wiring condition, soldering condition and connector connection are normal. If not, it may cause overheating or fire. Confirm that the temperature around the compressor is not too high, and then perform the repair work. Failure to do so may cause a burn. Perform welding work in a place with good ventilation. If the work is performed in a poorly ventilated area, it might cause a lack of oxygen. If the installation plate or attachment frame has deteriorated due to corrosion, etc., replace it. Failure to do so may cause an injury due to the unit falling. When the cleaning is to be performed, make sure to turn off the power and pull out the plug. Touching the fan that is rotating at high speed may result in an injury. When the indoor unit is to be removed, do not place it on an incline. Doing so may cause wet furniture because water left inside may trickle down. Prohibit Do not hold the sharp end of the unit or the aluminum fins, as it may cause an injury to your hand or finger. Prohibit After repairs, make sure to measure the insulation resistance and confirm that the value is 1 Mohm or more. Any insulation error may cause an electric shock. After repairs, make sure to check the drainage of the indoor unit. Inappropriate drainage may cause wet furniture and floors due to water leakage. 3

Table of Contents Page SAFETY PRECAUTIONS... 2 TABLE OF CONTENTS... 4 APPLICABLE INDOOR UNITS... 6 1. OPERATING RANGE... 7 2. SPECIFICATIONS 2-1. Unit Specifications 2-2. Major Component Specifications 2-3. Other Component Specifications......... 8 17 20 3. DIMENSIONAL DATA... 21 4. REFRIGERANT FLOW DIAGRAM 4-1. Refrigerant Flow Diagram... 5. PERFORMANCE DATA 5-1. Temperature Charts... 5-2. Cooling Capacity... 5-3. Cooling Capacity (Low Ambient)... 5-4. Heating Capacity... 24 27 56 62 6. ELECTRICAL DATA 6-1. Electric Wiring Diagrams... 7. FUNCTIONS 7-1. Explanation of Functions... 7-2. Protective Functions... 8. TROUBLESHOOTING (BEFORE CALLING FOR SERVICE) 8-1. Precautions before Performing Inspection or Repair... 8-2. Trouble Diagnosis by Error Monitop Lamps... 8-3. 8-4. 8-5. Checking the Outdoor System Trouble Diagnosis of Each Part Trouble Diagnosis of Fan Motor......... 71 80 81 82 83 87 4

Page 9. REFRIGERANT R0A: SPECIAL PRECAUTIONS WHEN SERVICING UNIT 9-1. Characteristics of New Refrigerant R0A... 9-2. Checklist before Servicing... 9-3. Tools Specifically for R0A... 9-4. Tubing Installation Procedures... 9-5. In Case of Compressor Malfunction... 9-6. 9-7. 9-8. In Case Refrigerant is Leaking Charging Additional Refrigerant Retro-Fitting Existing Systems......... 88 89 90 90 91 93 94 94 APPENDIX A INSTALLATION INSTRUCTIONS... A-1 5

APPLICABLE INDOOR UNITS Wall Mounted Type Multi-Outdoor Unit Indoor Unit CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU 3-Room CU-3KE19NBU YES YES YES YES NO 4-Room CU-4KE24NBU YES YES YES YES YES 4-Room CU-4KE31NBU YES YES YES YES YES Semi-Concealed Type Multi-Outdoor Unit Indoor Unit CS-MKE9NB4U & CZ-18BT1U CS-MKE12NB4U & CZ-18BT1U CS-KE12NB4UW & CZ-18BT1U 3-Room CU-3KE19NBU YES YES YES 4-Room CU-4KE24NBU YES YES YES 4-Room CU-4KE31NBU YES YES YES 6

1. OPERATING RANGE Cooling Heating Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum Minimum Maximum Minimum F DB / 71 F WB 67 F DB / 57 F WB 80 F DB / 67 F WB DB / WB 115 F DB 14 F DB 75 F DB / 65 F WB DB / 0 F WB 7

2. SPECIFICATIONS 2-1. Unit Specifications Outdoor Unit CU-3KE19NBU Indoor Unit CS-MKE9NKU 2 Duct Less Type Rated < 0V > Type 3-Room Multi Outdoor Unit Number of Connectable Indoor Units 3 Number of Operatable Indoor Units 3 Voltage Rating 0V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h kw 17,000 5.00 ( 6,800 to 18,600 ) ( 1.90 to 5.45),200 6.80 ( 7,800 to 24,800 ) ( 2.30 to 7.30) Sensible Capacity Latent Capacity BTU/h BTU/h 14,300 2,700 - - Air Circulation (High) ft 3 /min (m 3 /h) 1,707 (2,900) 1,707 (2,900) Available Voltage Range V 187 to 253 Running Amperes Power Input A W 6.3 1,420 9.1 2,0 Power Factor % 98 98 EER BTU/h/W 12.0 - COP W/W - 11.3 SEER BTU/Wh 18.0 - HSPF BTU/Wh - 8.8 Compressor Locked Rotor Amperes A 14.5 Fuse or Circuit Breaker Capacity A 15 Outdoor Unit Control Microprocessor Fan Speeds Auto (Hi, Me, Lo) Compressor Refrigerant / Amount charged at shipment Ibs (g) DC Twin Rotary (Inverter) R0A / 6.17 (2,800) Refrigerant Control Electric Expansion Valve Operation Sound (High) Cool / Heat db-a / 52 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit ft (m) 82 Refrigerant Narrow tube inch (mm) 1/4 (6.35) 3 Tube Diameter Wide tube inch (mm) 3/8 (9.52) 3 Outdoor Unit Unit Dimensions inch 29-1/8 35-7/16 12-19/ Height Width Depth Package Dimensions Height Width Depth (mm) inch (mm) (740 900 0) 34-3/16-11/ 16-21/ (8 1,0 4) Weight Shipping Volume Net Shipping Ibs (kg) Ibs (kg) cu.ft (m 3 ) 143.3 (65.0) 152.1 (69.0) 13. (0.38) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Performance Electrical Rating Features Dimensions & Weight Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKE9NKU 2units Outdoor Unit : CU-3KE19NBU 1unit The combination indoor unit is AHRI 210/240. 2. Rating conditions are: Cooling : Indoor air temp. 80 F DB / 67 F WB Heating : Indoor air temp. 70 F DB Outdoor air temp. F DB / 75 F WB Outdoor air temp. 47 F DB / 43 F WB 8

Outdoor Unit CU-3KE19NBU Indoor Unit CS-MKE9NKU 3 < 0V > Type 3-Room Multi Outdoor Unit Number of Connectable Indoor Units 3 Number of Operatable Indoor Units 3 Voltage Rating 0V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 18,600 ( 9,800 to 18,600 ) 24,800 ( 11,600 to 24,800 ) kw 5.45 ( 2.90 to 5.45 ) 7.30 ( 3.40 to 7.30 ) Sensible Capacity BTU/h 15,800 - Latent Capacity BTU/h 2,800 - Air Circulation (High) ft 3 /min (m 3 /h) 1,707 (2,900) 1,707 (2,900) Available Voltage Range V 187 to 253 Running Amperes A 6.5 7.7 Power Input W 1,470 1,735 Power Factor % 98 98 EER BTU/h/W 12.7 - COP W/W - 4.2 Compressor Locked Rotor Amperes A 14.5 Fuse or Circuit Breaker Capacity A 15 Outdoor Unit Control Microprocessor Fan Speeds Auto (Hi, Me, Lo) Compressor DC Twin Rotary (Inverter) Refrigerant / Amount charged at shipment Ibs (g) R0A / 6.17 (2,800) Refrigerant Control Electric Expansion Valve Operation Sound (High) Cool / Heat db-a / 52 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit ft (m) 82 Refrigerant Narrow tube inch (mm) 1/4 (6.35) 3 Tube Diameter Wide tube inch (mm) 3/8 (9.52) 3 Outdoor Unit Unit Dimensions inch 29-1/8 35-7/16 12-19/ Height Width Depth (mm) (740 900 0) Package Dimensions inch 34-3/16-11/ 16-21/ Height Width Depth (mm) (8 1,0 4) Weight Net Ibs (kg) 143.3 (65.0) Shipping Ibs (kg) 152.1 (69.0) Shipping Volume cu.ft (m 3 ) 13. (0.38) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Performance Electrical Rating Features Dimensions & Weight Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKE9NKU 3units Outdoor Unit : CU-3KE19NBU 1unit 2. Rating conditions are: Cooling : Indoor air temp. 80 F DB / 67 F WB Heating : Indoor air temp. 70 F DB Outdoor air temp. F DB / 75 F WB Outdoor air temp. 47 F DB / 43 F WB 9

Outdoor Unit CU-3KE19NBU Indoor Unit CS-MKE9NKU 3 < 208V > Type 3-Room Multi Outdoor Unit Number of Connectable Indoor Units 3 Number of Operatable Indoor Units 3 Voltage Rating 208V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 18,600 ( 9,800 to 18,600 ) 24,800 ( 11,600 to 24,800 ) kw 5.45 ( 2.90 to 5.45 ) 7.30 ( 3.40 to 7.30 ) Sensible Capacity BTU/h 15,800 - Latent Capacity BTU/h 2,800 - Air Circulation (High) ft 3 /min (m 3 /h) 1,707 (2,900) 1,707 (2,900) Available Voltage Range V 187 to 253 Running Amperes A 7.2 8.5 Power Input W 1,470 1,735 Power Factor % 98 98 EER BTU/h/W 12.7 - COP W/W - 4.2 Compressor Locked Rotor Amperes A 14.5 Fuse or Circuit Breaker Capacity A 15 Outdoor Unit Control Microprocessor Fan Speeds Auto (Hi, Me, Lo) Compressor DC Twin Rotary (Inverter) Refrigerant / Amount charged at shipment Ibs (g) R0A / 6.17 (2,800) Refrigerant Control Electric Expansion Valve Operation Sound (High) Cool / Heat db-a / 52 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit ft (m) 82 Refrigerant Narrow tube inch (mm) 1/4 (6.35) 3 Tube Diameter Wide tube inch (mm) 3/8 (9.52) 3 Outdoor Unit Unit Dimensions inch 29-1/8 35-7/16 12-19/ Height Width Depth (mm) (740 900 0) Package Dimensions inch 34-3/16-11/ 16-21/ Height Width Depth (mm) (8 1,0 4) Weight Net Ibs (kg) 143.3 (65.0) Shipping Ibs (kg) 152.1 (69.0) Shipping Volume cu.ft (m 3 ) 13. (0.38) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Performance Electrical Rating Features Dimensions & Weight Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKE9NKU 3units Outdoor Unit : CU-3KE19NBU 1unit 2. Rating conditions are: Cooling : Indoor air temp. 80 F DB / 67 F WB Heating : Indoor air temp. 70 F DB Outdoor air temp. F DB / 75 F WB Outdoor air temp. 47 F DB / 43 F WB 10

Outdoor Unit Indoor Unit CU-4KE24NBU CS-MKE7NKU 2 + CS-MKE9NKU Duct Less Type Rated < 0V > Type 4-Room Multi Outdoor Unit Number of Connectable Indoor Units 4 Number of Operatable Indoor Units 4 Voltage Rating 0V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 22,400 ( 8,0 to,200 ) 27,200 ( 10,200 to 29,200 ) kw 6.60 ( 2. to 6.80 ) 8.00 ( 3.00 to 8.60 ) Sensible Capacity BTU/h 18,800 - Latent Capacity BTU/h 3,600 - Air Circulation (High) ft 3 /min (m 3 /h) 1,707 (2,900) 1,707 (2,900) Available Voltage Range V 187 to 253 Running Amperes A 8.7 10.0 Power Input W 1,9 2,2 Power Factor % 98 98 EER BTU/h/W 11.5 - COP W/W - 12.1 SEER BTU/Wh 18.0 - HSPF BTU/Wh - 8.5 Compressor Locked Rotor Amperes A 14.5 Fuse or Circuit Breaker Capacity A 20 Outdoor Unit Control Microprocessor Fan Speeds Auto (Hi, Me, Lo) Compressor DC Twin Rotary (Inverter) Refrigerant / Amount charged at shipment Ibs (g) R0A / 6.17 (2,800) Refrigerant Control Electric Expansion Valve Operation Sound (High) Cool / Heat db-a / 52 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit ft (m) 82 Refrigerant Narrow tube inch (mm) 1/4 (6.35) 4 Tube Diameter Wide tube inch (mm) 3/8 (9.52) 3 + 1/2 (12.7) 1 Outdoor Unit Unit Dimensions inch 29-1/8 35-7/16 12-19/ Height Width Depth (mm) (740 900 0) Package Dimensions inch 34-3/16-11/ 16-21/ Height Width Depth (mm) (8 1,0 4) Weight Net Ibs (kg) 143.3 (65.0) Shipping Ibs (kg) 152.1 (69.0) Shipping Volume cu.ft (m 3 ) 13. (0.38) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Performance Electrical Rating Features Dimensions & Weight Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKE7NKU 2units / CS-MKE9NKU 1units Outdoor Unit : CU-4KE24NBU 1unit The combination indoor unit is AHRI 210/240. 2. Rating conditions are: Cooling : Indoor air temp. 80 F DB / 67 F WB Heating : Indoor air temp. 70 F DB Outdoor air temp. F DB / 75 F WB Outdoor air temp. 47 F DB / 43 F WB 11

Outdoor Unit CU-4KE24NBU Indoor Unit CS-MKE9NKU 3 < 0V > Type 4-Room Multi Outdoor Unit Number of Connectable Indoor Units 4 Number of Operatable Indoor Units 4 Voltage Rating 0V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h,200 ( 9,800 to,200 ) 29,200 ( 11,600 to 29,200 ) kw 6.80 ( 2.90 to 6.80 ) 8.60 ( 3.40 to 8.60 ) Sensible Capacity BTU/h 19,600 - Latent Capacity BTU/h 3,600 - Air Circulation (High) ft 3 /min (m 3 /h) 1,707 (2,900) 1,707 (2,900) Available Voltage Range V 187 to 253 Running Amperes A 9.0 10.1 Power Input W 2,040 2,270 Power Factor % 98 98 EER BTU/h/W 11.4 - COP W/W - 3.8 Compressor Locked Rotor Amperes A 14.5 Fuse or Circuit Breaker Capacity A 20 Outdoor Unit Control Microprocessor Fan Speeds Auto (Hi, Me, Lo) Compressor DC Twin Rotary (Inverter) Refrigerant / Amount charged at shipment Ibs (g) R0A / 6.17 (2,800) Refrigerant Control Electric Expansion Valve Operation Sound (High) Cool / Heat db-a / 52 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit ft (m) 82 Refrigerant Narrow tube inch (mm) 1/4 (6.35) 4 Tube Diameter Wide tube inch (mm) 3/8 (9.52) 3 + 1/2 (12.7) 1 Outdoor Unit Unit Dimensions inch 29-1/8 35-7/16 12-19/ Height Width Depth (mm) (740 900 0) Package Dimensions inch 34-3/16-11/ 16-21/ Height Width Depth (mm) (8 1,0 4) Weight Net Ibs (kg) 143.3 (65.0) Shipping Ibs (kg) 152.1 (69.0) Shipping Volume cu.ft (m 3 ) 13. (0.38) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Performance Electrical Rating Features Dimensions & Weight Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKE9NKU 3units Outdoor Unit : CU-4KE24NBU 1unit 2. Rating conditions are: Cooling : Indoor air temp. 80 F DB / 67 F WB Heating : Indoor air temp. 70 F DB Outdoor air temp. F DB / 75 F WB Outdoor air temp. 47 F DB / 43 F WB 12

Outdoor Unit CU-4KE24NBU Indoor Unit CS-MKE9NKU 3 < 208V > Type 4-Room Multi Outdoor Unit Number of Connectable Indoor Units 4 Number of Operatable Indoor Units 4 Voltage Rating 208V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h,200 ( 9,800 to,200 ) 29,200 ( 11,600 to 29,200 ) kw 6.80 ( 2.90 to 6.80 ) 8.60 ( 2.90 to 8.60 ) Sensible Capacity BTU/h 19,600 - Latent Capacity BTU/h 3,600 - Air Circulation (High) ft 3 /min (m 3 /h) 1,707 (2,900) 1,707 (2,900) Available Voltage Range V 187 to 253 Running Amperes A 10.0 11.1 Power Input W 2,040 2,270 Power Factor % 98 98 EER BTU/h/W 11.4 - COP W/W - 3.8 Compressor Locked Rotor Amperes A 14.5 Fuse or Circuit Breaker Capacity A 20 Outdoor Unit Control Microprocessor Fan Speeds Auto (Hi, Me, Lo) Compressor DC Twin Rotary (Inverter) Refrigerant / Amount charged at shipment Ibs (g) R0A / 6.17 (2,800) Refrigerant Control Electric Expansion Valve Operation Sound (High) Cool / Heat db-a / 52 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit ft (m) 82 Refrigerant Narrow tube inch (mm) 1/4 (6.35) 4 Tube Diameter Wide tube inch (mm) 3/8 (9.52) 3 + 1/2 (12.7) 1 Outdoor Unit Unit Dimensions inch 29-1/8 35-7/16 12-19/ Height Width Depth (mm) (740 900 0) Package Dimensions inch 34-3/16-11/ 16-21/ Height Width Depth (mm) (8 1,0 4) Weight Net Ibs (kg) 143.3 (65.0) Shipping Ibs (kg) 152.1 (69.0) Shipping Volume cu.ft (m 3 ) 13. (0.38) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Performance Electrical Rating Features Dimensions & Weight Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKE9NKU 3units Outdoor Unit : CU-4KE24NBU 1unit 2. Rating conditions are: Cooling : Indoor air temp. 80 F DB / 67 F WB Heating : Indoor air temp. 70 F DB Outdoor air temp. F DB / 75 F WB Outdoor air temp. 47 F DB / 43 F WB 13

Outdoor Unit Indoor Unit CU-4KE31NBU CS-MKE7NKU 3 + CS-MKE9NKU Duct Less Type Rated < 0V > Type 4-Room Multi Outdoor Unit Number of Connectable Indoor Units 4 Number of Operatable Indoor Units 4 Voltage Rating 0V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h kw 29,000 8. ( 9,800 to 29,000 ) ( 2.90 to 8. ) 30,600 9.00 ( 11,600 to,000 ) ( 3.40 to 9.40 ) Sensible Capacity Latent Capacity BTU/h BTU/h 24,400 4,600 - - Air Circulation (High) ft 3 /min (m 3 /h) 1,942 (3,300) 1,942 (3,300) Available Voltage Range V 187 to 253 Running Amperes Power Input A W 11.4 2,600 10.1 2,300 Power Factor % 99 99 EER BTU/h/W 11.2 - COP W/W - 13.3 SEER BTU/Wh 17.2 - HSPF BTU/Wh - 9.3 Compressor Locked Rotor Amperes A 17.0 Fuse or Circuit Breaker Capacity A 20 Outdoor Unit Control Microprocessor Fan Speeds Auto (Hi, Me, Lo) Compressor Refrigerant / Amount charged at shipment Ibs (g) DC Twin Rotary (Inverter) R0A / 8.38 (3,800) Refrigerant Control Electric Expansion Valve Operation Sound (High) Cool / Heat db-a 53 / 55 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit ft (m) 100 (30.5) Refrigerant Narrow tube inch (mm) 1/4 (6.35) 4 Tube Diameter Wide tube inch (mm) 3/8 (9.52) 2 + 1/2 (12.7) 2 Outdoor Unit Unit Dimensions inch 35-1/ 35-7/16 12-19/ Height Width Depth Package Dimensions Height Width Depth (mm) inch (mm) (890 900 0) 40-1/8-11/ 16-21/ (1,019 1,0 4) Weight Net Shipping Ibs (kg) Ibs (kg) 180.8 189.6 (82.0) (.0) Shipping Volume cu.ft (m 3 ) 15.88 (0.45) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Performance Electrical Rating Features Dimensions & Weight Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKE7NKU 3units / CS-MKE9NKU 1units Outdoor Unit : CU-4KE31NBU 1unit The combination indoor unit is AHRI 210/240. 2. Rating conditions are: Cooling : Indoor air temp. 80 F DB / 67 F WB Heating : Indoor air temp. 70 F DB Outdoor air temp. F DB / 75 F WB Outdoor air temp. 47 F DB / 43 F WB 14

Outdoor Unit CU-4KE31NBU Indoor Unit CS-MKE9NKU 4 < 0V > Type 4-Room Multi Outdoor Unit Number of Connectable Indoor Units 4 Number of Operatable Indoor Units 4 Voltage Rating 0V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 30,600 ( 9,800 to 30,600 ),000 ( 11,600 to,000 ) kw 9.00 ( 2.90 to 9.00 ) 9.40 ( 3.40 to 9.40 ) Sensible Capacity BTU/h 25,800 - Latent Capacity BTU/h 4,800 - Air Circulation (High) ft 3 /min (m 3 /h) 1,942 (3,300) 1,942 (3,300) Available Voltage Range V 187 to 253 Running Amperes A 12.3 10.3 Power Input W 2,800 2,3 Power Factor % 99 99 EER BTU/h/W 10.9 - COP W/W - 4.0 Compressor Locked Rotor Amperes A 17.0 Fuse or Circuit Breaker Capacity A 20 Outdoor Unit Control Microprocessor Fan Speeds Auto (Hi, Me, Lo) Compressor DC Twin Rotary (Inverter) Refrigerant / Amount charged at shipment Ibs (g) R0A / 8.38 (3,800) Refrigerant Control Electric Expansion Valve Operation Sound (High) Cool / Heat db-a 53 / 55 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit ft (m) 100 (30.5) Refrigerant Narrow tube inch (mm) 1/4 (6.35) 4 Tube Diameter Wide tube inch (mm) 3/8 (9.52) 2 + 1/2 (12.7) 2 Outdoor Unit Unit Dimensions inch 35-1/ 35-7/16 12-19/ Height Width Depth (mm) (890 900 0) Package Dimensions inch 40-1/8-11/ 16-21/ Height Width Depth (mm) (1,019 1,0 4) Weight Net Ibs (kg) 180.8 (82.0) Shipping Ibs (kg) 189.6 (.0) Shipping Volume cu.ft (m 3 ) 15.88 (0.45) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Performance Electrical Rating Features Dimensions & Weight Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKE9NKU 4units Outdoor Unit : CU-4KE31NBU 1unit 2. Rating conditions are: Cooling : Indoor air temp. 80 F DB / 67 F WB Heating : Indoor air temp. 70 F DB Outdoor air temp. F DB / 75 F WB Outdoor air temp. 47 F DB / 43 F WB 15

Outdoor Unit CU-4KE31NBU Indoor Unit CS-MKE9NKU 4 < 208V > Type 4-Room Multi Outdoor Unit Number of Connectable Indoor Units 4 Number of Operatable Indoor Units 4 Voltage Rating 208V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 28,600 ( 9,800 to 28,600 ),000 ( 11,600 to,000 ) kw 8.40 ( 2.90 to 8.40 ) 9.40 ( 3.40 to 9.40 ) Sensible Capacity BTU/h 24,200 - Latent Capacity BTU/h 4,400 - Air Circulation (High) ft 3 /min (m 3 /h) 1,942 (3,300) 1,942 (3,300) Available Voltage Range V 187 to 253 Running Amperes A 12.7 11.4 Power Input W 2,560 2,3 Power Factor % 99 99 EER BTU/h/W 11.2 - COP W/W - 4.0 Compressor Locked Rotor Amperes A 17.0 Fuse or Circuit Breaker Capacity A 20 Outdoor Unit Control Microprocessor Fan Speeds Auto (Hi, Me, Lo) Compressor DC Twin Rotary (Inverter) Refrigerant / Amount charged at shipment Ibs (g) R0A / 8.38 (3,800) Refrigerant Control Electric Expansion Valve Operation Sound (High) Cool / Heat db-a 53 / 55 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit ft (m) 100 (30.5) Refrigerant Narrow tube inch (mm) 1/4 (6.35) 4 Tube Diameter Wide tube inch (mm) 3/8 (9.52) 2 + 1/2 (12.7) 2 Outdoor Unit Unit Dimensions inch 35-1/ 35-7/16 12-19/ Height Width Depth (mm) (890 900 0) Package Dimensions inch 40-1/8-11/ 16-21/ Height Width Depth (mm) (1,019 1,0 4) Weight Net Ibs (kg) 180.8 (82.0) Shipping Ibs (kg) 189.6 (.0) Shipping Volume cu.ft (m 3 ) 15.88 (0.45) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Performance Electrical Rating Features Dimensions & Weight Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKE9NKU 4units Outdoor Unit : CU-4KE31NBU 1unit 2. Rating conditions are: Cooling : Indoor air temp. 80 F DB / 67 F WB Heating : Indoor air temp. 70 F DB Outdoor air temp. F DB / 75 F WB Outdoor air temp. 47 F DB / 43 F WB 16

2-2. Major Component Specifications 2-2-1. Outdoor Unit Outdoor Unit CU-3KE19NBU Control PCB Part No. Controls Control Circuit Fuse Compressor Type Compressor Model / Nominal Output Compressor Oil... Amount Pints (cc) Coil Resistance (Ambient Temp. F (20 C)) Ohm Safety Device CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Overload Relay Model Operation Temp. Run Capacitor Crankcase Heater Micro F VAC CB-CU-3KE19NBU Microprocessor 2V 25A DC Twin Rotary (Hermetic) 5KD240XAB21 / 1,700W FVS... 1.91 (900) U - V : 0.720 V - W : 0.708 W - U : 0.726 Yes Yes Yes CS-7L-2515 Open : 9 F (115 C), Close : 212 F (100 C) - - 0V 30W Fan Type Q'ty... Dia. inch (mm) Propeller 1... D18-1/8 (D460) Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool / Heat) Nominal Output Coil Resistance (Ambient Temp. F (20 C)) Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor W Ohm Micro F VAC DC Motor SIC-71FW-D490-1... 1 8 7 / 7 90 - Internal Controller Yes Yes - - Heat Exchanger Coil Coil Rows Fins per inch Aluminum Plate Fin / Copper Tube 2 18.1 Face Area ft 2 (m 2 ) 6.40 (0.5) External Finish Acrylic baked-on enamel finish DATA SUBJECT TO CHANGE WITHOUT NOTICE. 17

Outdoor Unit CU-4KE24NBU Control PCB Part No. Controls Control Circuit Fuse Compressor Type Compressor Model / Nominal Output Compressor Oil... Amount Pints (cc) Coil Resistance (Ambient Temp. F (20 C)) Ohm Safety Device CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Overload Relay Model Operation Temp. Run Capacitor Crankcase Heater Micro F VAC CB-CU-4KE24NBU Microprocessor 2V 25A DC Twin Rotary (Hermetic) 5KD240XAB21 / 1,700W FVS... 1.91 (900) U - V : 0.720 V - W : 0.708 W - U : 0.726 Yes Yes Yes CS-7L-2515 Open : 9 F (115 C), Close : 212 F (100 C) - - 0V 30W Fan Type Q'ty... Dia. inch (mm) Propeller 1... D18-1/8 (D460) Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool / Heat) Nominal Output Coil Resistance (Ambient Temp. F (20 C)) Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor W Ohm Micro F VAC DC Motor SIC-71FW-D490-1... 1 8 7 / 7 90 - Internal Controller Yes Yes - - Heat Exchanger Coil Coil Rows Fins per inch Aluminum Plate Fin / Copper Tube 2 18.1 Face Area ft 2 (m 2 ) 6.40 (0.5) External Finish Acrylic baked-on enamel finish DATA SUBJECT TO CHANGE WITHOUT NOTICE. 18

Outdoor Unit CU-4KE31NBU Control PCB Part No. Controls Control Circuit Fuse Compressor Type Compressor Model / Nominal Output Compressor Oil... Amount Pints (cc) Coil Resistance (Ambient Temp. F (20 C)) Ohm Safety Device CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Overload Relay Model Operation Temp. Run Capacitor Crankcase Heater Micro F VAC CB-CU-4KE31NBU Microprocessor 2V 25A DC Twin Rotary (Hermetic) 5JD420XAB22 / 3,000W FVS... 2.55 (1,200) U - V : 0.435 V - W : 0.4 W - U : 0.452 Yes Yes Yes CS-7L-2515 Open : 9 F (115 C), Close : 212 F (100 C) - - 0V 30W Fan Type Q'ty... Dia. inch (mm) Propeller 1... D18-1/8 (D460) Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool / Heat) Nominal Output Coil Resistance (Ambient Temp. F (20 C)) Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor W Ohm Micro F VAC DC Motor SIC-71FW-D490-1... 1 8 800 / 800 90 - Internal Controller Yes Yes - - Heat Exchanger Coil Coil Rows Fins per inch Aluminum Plate Fin / Copper Tube 2 18.1 Face Area ft 2 (m 2 ) 7.75 (0.72) External Finish Acrylic baked-on enamel finish DATA SUBJECT TO CHANGE WITHOUT NOTICE. 19

2-3. Other Component Specifications Sensor Name Model No. of sensor Quantity of Sensor CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU Outdoor air temp sensor TKS2B 1 1 1 Outdoor heat exchanger sensor TKS292B 1 1 1 AW / AN sensor TKS292B 1 / 1 1 / 1 1 / 1 BW / BN sensor TKS292B 1 / 1 1 / 1 1 / 1 CW / CN sensor TKS292B 1 / 1 1 / 1 1 / 1 DW / DN sensor TKS292B 0 1 / 1 1 / 1 40 Resistance (k ohm) 35 30 25 20 15 10 5 0-4 5 14 (-20)(-15)(-10) Temperature F ( C) Sensor Name Model No. of sensor Quantity of Sensor CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU Compressor temp sensor TKS293B 1 1 1 200 180 Resistance (k ohm) 160 140 120 100 80 60 40 20 0 122 140 158 176 194 () (60) (70) (80) (90) Temperature F ( C) 20

3. DIMENSIONAL DATA Outdoor Unit CU-3KE19NBU -15/16 5-11/ 1-3/8 11-17/ ID:/ 5-ID:15/16 15/ 35-7/16(900) Wide tube service valve dia.3/8" (9.52) 3 Narrow tube service valve dia.1/4" (6.35) 3 / 5-29/ 2-27/ 2-3/4 4-7/16 2-15/16 2-3/4 29-1/8(740) 12-19/ 13-19/ 14-17/ 2-15/16 1-13/16 2-1/ 4-1/2 2-1/16 Unit: inch(mm) (852-0-0010-11200-0) 21

Outdoor Unit CU-4KE24NBU -15/16 5-11/ 1-3/8 11-17/ ID:/ 5-ID:15/16 15/ 12-19/ 13-19/ 14-17/ 35-7/16(900) 2-15/16 Wide tube service valve dia.1/2" (12.70) 1 Narrow tube service valve dia.1/4" (6.35) 4 / 29-1/8(740) 5-29/ 2-27/ 2-3/4 2-3/4 Wide tube service valve dia.3/8" (9.52) 3 2-15/16 2-3/4 2-3/4 4-7/16 1-13/16 2-1/ 4-1/2 2-1/16 2-13/ Unit: inch(mm) (852-0-0010-20400-0) 22

Outdoor Unit CU-4KE31NBU -15/16 5-11/ 1-3/8 11-17/ ID:/ 5-ID:15/16 15/ 35-7/16(900) Wide tube service valve dia.1/2" (12.70) 2 Narrow tube service valve dia.1/4" (6.35) 4 Wide tube service valve dia.3/8" (9.52) 2 / 5-29/ 4-7/16 2-15/16 2-3/4 2-3/4 12-19/ 13-19/ 14-17/ 2-15/16 35-1/(890) 2-7/8 2-3/4 2-3/4 1-13/16 2-1/ 4-1/2 2-1/16 2-13/ Unit: inch(mm) (852-0-0010-20300-0)

4. REFRIGERANT FLOW DIAGRAM 4-1. Refrigerant Flow Diagram Outdoor Unit CU-3KE19NBU Indoor unit Outdoor unit Wide tube O.D.3/8" O.D.3/8" O.D.3/8" Service valve on wide tube CW BW AW Header Sub accumulator Main accumulator High pressure switch H.P. Compressor 4-way valve Narrow tube O.D.1/4" O.D.1/4" O.D.1/4" Service valve on narrow tube CN BN AN Strainer Electric expansion valve M M M Header Defrost valve for hot gas bypass S Heat exchanger Cooling cycle Heating cycle Defrosting cycle Insulation of Refrigerant Tubing IMPORTANT Because capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping of condensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min.5/16"(8 mm). Thickness: Min.5/16"(8 mm) Insulation Thickness: Min.5/16"(8 mm) CAUTION After a tube has been insulated, never try to bend it into a narrow curve because it can cause the tube to break or crack. Wide tube Narrow tube 24

Outdoor Unit CU-4KE24NBU Indoor unit Outdoor unit Wide tube O.D.1/2" O.D.3/8" O.D.3/8" O.D.3/8" Service valve on wide tube DW CW BW AW Header 4-way valve Sub accumulator Main accumulator High pressure switch H.P. Compressor Narrow tube O.D.1/4" O.D.1/4" O.D.1/4" O.D.1/4" Service valve on narrow tube DN CN BN AN Strainer Electric expansion valve M M M M Header Defrost valve for hot gas bypass S Heat exchanger Cooling cycle Heating cycle Defrosting cycle Insulation of Refrigerant Tubing IMPORTANT Because capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping of condensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min.5/16"(8 mm). Thickness: Min.5/16"(8 mm) Insulation Thickness: Min.5/16"(8 mm) CAUTION After a tube has been insulated, never try to bend it into a narrow curve because it can cause the tube to break or crack. Wide tube Narrow tube 25

Outdoor Unit CU-4KE31NBU Indoor unit Outdoor unit Wide tube O.D.1/2" O.D.1/2" O.D.3/8" O.D.3/8" Service valve on wide tube DW CW BW AW Header 4-way valve Sub accumulator Main accumulator High pressure switch H.P. Compressor Narrow tube O.D.1/4" O.D.1/4" O.D.1/4" O.D.1/4" Service valve on narrow tube DN CN BN AN Strainer Electric expansion valve M M M M Header Defrost valve for hot gas bypass S Heat exchanger Cooling cycle Heating cycle Defrosting cycle Insulation of Refrigerant Tubing IMPORTANT Because capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping of condensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min.5/16"(8 mm). Thickness: Min.5/16"(8 mm) Insulation Thickness: Min.5/16"(8 mm) CAUTION After a tube has been insulated, never try to bend it into a narrow curve because it can cause the tube to break or crack. Wide tube Narrow tube 26

5. PERFORMANCE DATA 5-1. Temperature Charts 5-1-1. Temperature Charts (CU-3KE19NBU) Outdoor Unit CU-3KE19NBU Indoor Unit CS-MKE7NKU 1 Cooling Characteristics (RH : 46%, Indoor fan speed : High fan) (0V, 60Hz) Heating Characteristics (RH : 85%, Indoor fan speed : High fan) (0V, 60Hz) (1) Low pressure performance chart (1) High pressure performance chart Low pressure at wide tube service valve psig (MPaG) 188 (1.3) 174 (1.2) 160 (1.1) 146 (1.0) (2) Operating current performance chart (2) Operating current performance chart 5 Lo fan Hi fan HH fan Indoor air temp. F (30 C) Lo fan Hi fan HH fan High pressure at wide tube service valve psig (MPaG) 6 (3.5) 434 (3.0) 362 (2.5) 290 (2.0) 8 Operating current (A) 4 3 Indoor air temp. F (30 C) Operating current (A) 7 6 5 2 (3) Indoor discharge air performance chart (3) Indoor discharge air performance chart Indoor discharge air temperature F ( C).0 64.4(18) 60.8(16) 57.2(14) 53.6(12).0 46.4( 8) Lo fan Hi fan HH fan Indoor air temp. F (30 C) Indoor discharge air temperature F ( C) 140(60) 131(55) 122() 113(45) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 24.6t (7.5m). If the tubing length is different, the performance chart will vary. 27

Outdoor Unit CU-3KE19NBU Indoor Unit CS-MKE9NKU 1 Cooling Characteristics (RH : 46%, Indoor fan speed : High fan) (0V, 60Hz) Heating Characteristics (RH : 85%, Indoor fan speed : High fan) (0V, 60Hz) (1) Low pressure performance chart (1) High pressure performance chart Low pressure at wide tube service valve psig (MPaG) 188 (1.3) 174 (1.2) 160 (1.1) Lo fan Hi fan Indoor air temp. F (30 C) HH fan High pressure at wide tube service valve psig (MPaG) 6 (3.5) 434 (3.0) 362 (2.5) 146 (1.0) 290 (2.0) (2) Operating current performance chart (2) Operating current performance chart 8 Lo fan Hi fan HH fan 6 Operating current (A) 5 4 Indoor air temp. F (30 C) Operating current (A) 7 6 5 3 (3) Indoor discharge air performance chart (3) Indoor discharge air performance chart Indoor discharge air temperature F ( C).0 64.4(18) 60.8(16) 57.2(14) 53.6(12).0 46.4( 8) Lo fan Hi fan Indoor air temp. F (30 C) HH fan NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 24.6ft (7.5m). If the tubing length is different, the performance chart will vary. Indoor discharge air temperature F ( C) 140(60) 131(55) 122() 113(45) 28

Outdoor Unit CU-3KE19NBU Indoor Unit CS-MKE12NKU 1 Cooling Characteristics Heating Characteristics (RH : 46%, Indoor fan speed : High fan) (RH : 85%, Indoor fan speed : High fan) (0V, 60Hz) (0V, 60Hz) (1) Low pressure performance chart (1) High pressure performance chart Low pressure at wide tube service valve psig (MPaG) 174 (1.2) 160 (1.1) 146 (1.0) 1 (0.9) Lo fan Hi fan Indoor air temp. F (30 C) HH fan High pressure at wide tube service valve psig (MPaG) 578 (4.0) 6 (3.5) 434 (3.0) 362 (2.5) 20 F (2) Operating current performance chart (2) Operating current performance chart Operating current (A) Lo fan 6 5 4 10 Hi fan HH fan 9 Indoor air temp. F (30 C) Operating current (A) 8 7 6 5 4 3 3 (3) Indoor discharge air performance chart (3) Indoor discharge air performance chart Indoor discharge air temperature F ( C).0 64.4(18) 60.8(16) 57.2(14) 53.6(12).0 46.4( 8) Lo fan Hi fan Indoor air temp. F (30 C) HH fan NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 24.6ft (7.5m). If the tubing length is different, the performance chart will vary. 29 Indoor discharge air temperature F ( C) 140(60) 131(55) 122() 113(45)

Outdoor Unit CU-3KE19NBU Indoor Unit CS-MKE18NKU 1 Cooling Characteristics (RH : 46%, Indoor fan speed : High fan) (0V, 60Hz) Heating Characteristics (RH : 85%, Indoor fan speed : High fan) (0V, 60Hz) (1) Low pressure performance chart (1) High pressure performance chart Low pressure at wide tube service valve psig (MPaG) 174 (1.2) 160 (1.1) 146 (1.0) Lo fan Hi fan Indoor air temp. F (30 C) HH fan High pressure at wide tube service valve psig (MPaG) 578 (4.0) 6 (3.5) 434 (3.0) 1 (0.9) 362 (2.5) (2) Operating current performance chart (2) Operating current performance chart 8 Lo fan Hi fan HH fan 12 Operating current (A) 7 6 5 Indoor air temp. F (30 C) Operating current (A) 11 10 9 8 7 6 (3) Indoor discharge air performance chart (3) Indoor discharge air performance chart Indoor discharge air temperature F ( C).0 64.4(18) 60.8(16) 57.2(14) 53.6(12).0 46.4( 8) Lo fan Hi fan Indoor air temp. F (30 C) HH fan Indoor discharge air temperature F ( C) 140(60) 131(55) 122() 113(45) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 24.6ft (7.5m). If the tubing length is different, the performance chart will vary. 30

Outdoor Unit CU-3KE19NBU Indoor Unit CS-MKE9NB4U 1 Cooling Characteristics (RH : 46%, Indoor fan speed : High fan) (0V, 60Hz) Heating Characteristics (RH : 85%, Indoor fan speed : High fan) (0V, 60Hz) (1) Low pressure performance chart (1) High pressure performance chart Low pressure at wide tube service valve psig (MPaG) 174 (1.2) 160 (1.1) 146 (1.0) Lo fan Hi fan Indoor air temp. F (30 C) HH fan High pressure at wide tube service valve psig (MPaG) 6 (3.5) 434 (3.0) 362 (2.5) 1 (0.9) 290 (2.0) (2) Operating current performance chart (2) Operating current performance chart 6 8 Lo fan Hi fan HH fan Operating current (A) 5 4 3 Indoor air temp. F (30 C) Operating current (A) 7 6 5 (3) Indoor discharge air performance chart (3) Indoor discharge air performance chart Indoor discharge air temperature F ( C).0 64.4(18) 60.8(16) 57.2(14) 53.6(12).0 46.4( 8) Lo fan Hi fan HH fan Indoor air temp. F (30 C) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 24.6ft (7.5m). If the tubing length is different, the performance chart will vary. Indoor discharge air temperature F ( C) 140(60) 131(55) 122() 113(45) 31

Outdoor Unit CU-3KE19NBU Indoor Unit CS-MKE12NB4U 1 Cooling Characteristics Heating Characteristics (RH : 46%, Indoor fan speed : High fan) (RH : 85%, Indoor fan speed : High fan) (0V, 60Hz) (0V, 60Hz) (1) Low pressure performance chart (1) High pressure performance chart Low pressure at wide tube service valve psig (MPaG) 174 (1.2) 160 (1.1) 146 (1.0) 1 (0.9) Lo fan Hi fan Indoor air temp. F (30 C) HH fan High pressure at wide tube service valve psig (MPaG) 578 (4.0) 6 (3.5) 434 (3.0) 362 (2.5) (2) Operating current performance chart (2) Operating current performance chart Operating current (A) Lo fan 6 5 4 10 Hi fan HH fan 9 Indoor air temp. F (30 C) Operating current (A) 8 7 6 5 4 3 3 (3) Indoor discharge air performance chart (3) Indoor discharge air performance chart Indoor discharge air temperature F ( C).0 64.4(18) 60.8(16) 57.2(14) 53.6(12).0 46.4( 8) 42.8( 6) Lo fan Hi fan Indoor air temp. F (30 C) HH fan NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 24.6ft (7.5m). If the tubing length is different, the performance chart will vary. Indoor discharge air temperature F ( C) 140(60) 131(55) 122() 113(45)

Outdoor Unit CU-3KE19NBU Indoor Unit CS-KE12NB4UW 1 Cooling Characteristics (RH : 46%, Indoor fan speed : High fan) (0V, 60Hz) Heating Characteristics (RH : 85%, Indoor fan speed : High fan) (0V, 60Hz) (1) Low pressure performance chart (1) High pressure performance chart Low pressure at wide tube service valve psig (MPaG) 174 (1.2) 160 (1.1) 146 (1.0) 1 (0.9) Lo fan Hi fan Indoor air temp. F (30 C) HH fan High pressure at wide tube service valve psig (MPaG) 578 (4.0) 6 (3.5) 434 (3.0) 362 (2.5) (2) Operating current performance chart (2) Operating current performance chart 7 Lo fan Hi fan HH fan 12 Operating current (A) 6 5 Indoor air temp. F (30 C) Operating current (A) 11 10 9 8 7 4 6 (3) Indoor discharge air performance chart (3) Indoor discharge air performance chart Indoor discharge air temperature F ( C).0 64.4(18) 60.8(16) 57.2(14) 53.6(12).0 46.4( 8) 42.8( 6) Lo fan Hi fan Indoor air temp. F (30 C) HH fan Indoor discharge air temperature F ( C) 140(60) 131(55) 122() 113(45) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 24.6ft (7.5m). If the tubing length is different, the performance chart will vary. 33

5-1-2. Temperature Charts (CU-4KE24NBU) Outdoor Unit CU-4KE24NBU Indoor Unit CS-MKE7NKU 1 Cooling Characteristics (RH : 46%, Indoor fan speed : High fan) (0V, 60Hz) Heating Characteristics (RH : 85%, Indoor fan speed : High fan) (0V, 60Hz) (1) Low pressure performance chart (1) High pressure performance chart Low pressure at wide tube service valve psig (MPaG) 188 (1.3) 174 (1.2) 160 (1.1) 146 (1.0) (2) Operating current performance chart (2) Operating current performance chart 5 Lo fan Hi fan HH fan Indoor air temp. F (30 C) Lo fan Hi fan HH fan High pressure at wide tube service valve psig (MPaG) 6 (3.5) 434 (3.0) 362 (2.5) 290 (2.0) 8 Operating current (A) 4 3 Indoor air temp. F (30 C) Operating current (A) 7 6 5 2 (3) Indoor discharge air performance chart (3) Indoor discharge air performance chart Indoor discharge air temperature F ( C).0 64.4(18) 60.8(16) 57.2(14) 53.6(12).0 46.4( 8) Lo fan Hi fan HH fan Indoor air temp. F (30 C) Indoor discharge air temperature F ( C) 140(60) 131(55) 122() 113(45) NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 24.6t (7.5m). If the tubing length is different, the performance chart will vary. 34

Outdoor Unit CU-4KE24NBU Indoor Unit CS-MKE9NKU 1 Cooling Characteristics (RH : 46%, Indoor fan speed : High fan) (0V, 60Hz) Heating Characteristics (RH : 85%, Indoor fan speed : High fan) (0V, 60Hz) (1) Low pressure performance chart (1) High pressure performance chart Low pressure at wide tube service valve psig (MPaG) 188 (1.3) 174 (1.2) 160 (1.1) Lo fan Hi fan Indoor air temp. F (30 C) HH fan High pressure at wide tube service valve psig (MPaG) 6 (3.5) 434 (3.0) 362 (2.5) 146 (1.0) 290 (2.0) (2) Operating current performance chart (2) Operating current performance chart 8 Lo fan Hi fan HH fan 6 Operating current (A) 5 4 Indoor air temp. F (30 C) Operating current (A) 7 6 5 3 (3) Indoor discharge air performance chart (3) Indoor discharge air performance chart Indoor discharge air temperature F ( C).0 64.4(18) 60.8(16) 57.2(14) 53.6(12).0 46.4( 8) Lo fan Hi fan Indoor air temp. F (30 C) HH fan NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 24.6ft (7.5m). If the tubing length is different, the performance chart will vary. Indoor discharge air temperature F ( C) 140(60) 131(55) 122() 113(45) 35

Outdoor Unit CU-4KE24NBU Indoor Unit CS-MKE12NKU 1 Cooling Characteristics Heating Characteristics (RH : 46%, Indoor fan speed : High fan) (RH : 85%, Indoor fan speed : High fan) (0V, 60Hz) (0V, 60Hz) (1) Low pressure performance chart (1) High pressure performance chart Low pressure at wide tube service valve psig (MPaG) 174 (1.2) 160 (1.1) 146 (1.0) 1 (0.9) Lo fan Hi fan Indoor air temp. F (30 C) HH fan High pressure at wide tube service valve psig (MPaG) 578 (4.0) 6 (3.5) 434 (3.0) 362 (2.5) (2) Operating current performance chart (2) Operating current performance chart Operating current (A) Lo fan 6 5 4 10 Hi fan HH fan 9 Indoor air temp. F (30 C) Operating current (A) 8 7 6 5 4 3 3 (3) Indoor discharge air performance chart (3) Indoor discharge air performance chart Indoor discharge air temperature F ( C).0 64.4(18) 60.8(16) 57.2(14) 53.6(12).0 46.4( 8) Lo fan Hi fan Indoor air temp. F (30 C) HH fan NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 24.6ft (7.5m). If the tubing length is different, the performance chart will vary. 36 Indoor discharge air temperature F ( C) 140(60) 131(55) 122() 113(45)