MSD Cabinets. Modular Dry Cabinet. Outstanding performance

Similar documents
XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

HSD Dry Cabinet. Outstanding performance

HSD Dry Cabinet. Outstanding performance

Long Term Storage Cabinet

XSD Dry Cabinet

HSD Dry Cabinet

XSD Dry Cabinet

SD Storage Cabinet. Outstanding performance

SD Storage Cabinet. Outstanding performance

XSD Dry Cabinet

SDR Dry Room. Outstanding performance

SD Storage Cabinet

SDB Storage Cabinet

Drying Cabinets and Vacuum Machines for Moisture Sensitive Components

Drying Cabinets and Vacuum Machines for Moisture Sensitive Components

A Member of the ASYS Group A Member of the ASYS Group PRODUCT CATALOGUE

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Chromatographic Air circulated Refrigerator, two-door TC 603

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

Constant climate chambers

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

KMF Environmental test chamber for constant climate

EC 160 CO 2. Incubator

Environmental simulation chamber for complex alternating climate profiles

Constant climate chamber with humidity

Drying and heating chambers

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Dew point set DS 400

Constant climate chamber with ICH-compliant illumination

Constant climate chambers

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Laboratory Refrigerator/Deep Freezer TC 802

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Constant climate chambers

Specifications Minimum Typical Maximum Unit

Plant growth chambers

Revolution of Low Humidity Storage!!

Chromatographic Air circulated Refrigerator, two-door TC 603

Constant climate chambers

Termaks AS Lien 79, N-5057 Bergen, Norway Tel: Fax: Web:

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

ULTRA-LOW HUMIDITY STORAGE CABINETS 1, 3%RH

HUM-M2 Humidity Sensor Module Description

FITOCLIMA 600 & 1200 STABILITY

Drying and heating chambers. Series ED FD FED FP M

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

NEW GENERATION. Efficient use of valuable space INCUBATORS

EST User Manual. (Please read this manual carefully before using)

EL-USB-TC Thermocouple Data Logger with USB Interface

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

WHO PQS-Code E006/016. Q-tag CLm doc USB Multi- Limit Temperature Indicator

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

Substation Monitoring System

Constant climate chambers

Multi-Lab REFRIGERATORS Frigidere medicale

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Constant climate chambers

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700


FITOCLIMA 600 & 1200 STABILITY

Huminator II. Precision Humidity Generator. ww.testo.in

Model KBF 240 Constant climate chambers with large temperature / humidity range

RAYCHEM NGC-30 COMPONENTS

LORAIN CIP 4890/48120 DC Power System

New Generation KBF 240 series

LORAIN CSP DC Power System

CO₂ incubators. C CB series

Model KBWF 240 Growth chambers with light and humidity

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

N-Wissen GmbH. Top Loading Autoclaves (95, 120, 135 L) Available top loading models: The Top Loading Autoclave range features:

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

DEKO 25 washer-disinfector

THX-DL Data Logger USER & INSTALLATION MANUAL V

EL-OEM-3 OEM Packaged Voltage Data Logger

STABILITY ICH. ICH Stability Tests

incubator, the best in its class

Constant climate chambers

Added password for IP setup page : Password must be in IP format!

INSTRUCTION MANUAL ESDA Cabinets with display

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

SUPREMATouch Modular Fire & Gas Detection System

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

Specification for On-Line UPS Battery Monitoring and Data Management System

CO₂ incubators. C CB series

Refrigerated Incubator Model and Operating Instructions

Sunrise the beginning of a brand new day

gas monitoring system

Transcription:

Modular Dry Cabinet Outstanding performance A cabinet that grows with your demand, the MSD series is the first modular dry cabinet that can be expanded as your storage and drying needs increase. Incorporating our extremely powerful U 5000 series dynamic drying unit, the basic MSD can be expanded to 4800 litres without the need for additional drying units. Regeneration times are reduced due to the closed loop control of the drying unit which automatically responds to atmosphere and frequent door openings, while delivering precise humidity control to 0,5% RH with traceability to a computer or network.

Standard features User friendly handling Touchscreen display with easy menu structure ESD features Norm (IEC 61340 5 1) ESD metal painted body (<10 6 Ohm/sq) Dissipative glazing (in and outside 10 8 Ohm/sq) Online functionality Interface and data logging through standard Ethernet interface Compatible with new MSL 2.0 software Transport 4 castors, ESD safe, for moving empty cabinets Door & humidity alarm buzzer Longer door openings are detected, high RH levels are detected Leveling out Adjustable legs Lockable doors Every door can be locked separately with a key. Sliding shelves In height adjustable sliding shelves on metal rollers (4 pcs) U 5000 series drying unit 0,5% RH, made in Germany Rotronic sensor Precision sensor, accuracy +/ 0,8 % RH, +/ 0,3 C Power supply Power cord 5 meter with IEC plug Benefits Drying time (see reference table) Fast drying time, Level 3 component, <1,4 mm = 8 days (25 C / 1% RH) Recovery time after door opening < 6 minutes to below 1% (with 1 cabinet and 1 door opening) Modular system Can be extended depending on your requirements Temperature setting Heating up to 40 C, accuracy +/ 2 C Low energy consumption As a result of a Dynamic dry unit Network Standard ethernet interface IPC According to IPC Jstd 033C & IPC 1601 European Quality Made in Germany Maintenance Easy to service, low maintenance

Technical data cabinets External dimensions: (W x H x D) 840 x 2040 x 900 mm Internal dimensions 1222: (W x H x D) 830 x 1780 x 730 mm Internal dimensions 1223: (W x H x D) 830 x 1780 x 850 mm Weight 1222: 140 kg Weight 1223: 125 kg Weight on shelf: 50 kg Shelves (WxD) 1222: 2 pcs short, 735 x 580 mm 2 pcs long, 735 x 740 mm Shelves (WxD) 1223: 4 pcs long, 735 x 740 mm Volume: 1200 L Electric supply: 230 VAC (120 VAC optional) Power consumption: 30 W/h Protection class: Class 1, hard grounded Humidity level cabinet: 0,5% RH can be reached with drying unit U 5003 Sensor accuracy: +/ 0,8 % RH, +/ 0,3 C Temperature accuracy: 40 C, +/ 2 C (with optional heater) Technical data type 4 display Settings Language Menu Nominal Value Humidity Humidity Alarm Delay Humidity Alarm Nominal Value Temperature (in combination with heater) Temperature Alarm (in combination with heater) Delay Temperature Alarm (in combination with heater) Sensor Offset Password Protection Floor Lifetime Reset Timer Manual Regeneration Display Supply voltage (supplied by drying unit) 24 VAC/DC, 350 ma Input Touchscreen TFT Color LCD 4,3 Controllable Brightness Ethernet connection

Technical data Rotronic sensor HC2A S Based on the Airchip 3000 Technology use the HygroClip 2 probes can be used for control of temperature and humidity. The HygroClip 2 probes can be configured with the ROTRONIC HW4 software and share the following features: Measurement of relative humidity and temperature Programmable automatic sensor test with failsafe mode and sensor drift compensation. Technical data dry unit U 5000 series Dehumidifying performance: 120 g/h max. Minimal humidity 0,2% RH Dehumidifying Temperature 10 60 C Electric supply: 230 VAC Dimensions (L x B x H): 487 x 487 x 150 mm Weight: 14 kg Technical data heater SH 1200 Power: 1650 W Thermal protection: 70 C Temperature range: 0 40 C Air flow: 550 m 3 /h Power supply: 230 VAC (120 VAC also available)

Free Totech viewer Writing of climate data, door openings and alarms to SD card Transfer data through Ethernet to PC (history data) User friendly display of all relevant data Data processing in MS Excel Seamless documentation Excellent process safety

Performance test

Performance test

Performance test

Performance test

Performance test Test conditions Instrument: Vaisala Type of dew point sensor: Rotronic sensor Accuracy of dew point sensor: ± 0,3 C at + 20 C (+ 68 F) Location of sensors: In the direct surroundings of the cabinet sensor Ambient conditions: Hum. 50 ± 5% rh, 22 C ± 2 C, Pressure 994 ± 20 hpa Door openings: 2 door openings, 15 sec. (average RH 0,70%) For more detailed test results, please refer to our website.

Technical drawings Dimensions mentioned in mm. Shelves Number of different types of shelves that can be mounted in the cabinet Number of shelves bottom section 2 3 4 5 6 7 8 Distance (in mm) between shelves if equally divided 375 290 170 130 90 65 50 Remaining space between top shelf and middle beam 310 75 115 75 115 115 155 Number of shelves top section 2 3 4 5 6 7 8 Distance (in mm) between shelves if equally divided 375 290 170 130 90 65 50 Remaining space between top shelf and top cabinet 310 75 115 75 115 115 155

Options SMD Reel rack with reel supports L x W = 530 x 265 mm incl. 18 reel supports. Item number 20014005 Reel support Additional reel supports for 20014005. Item number 20014201 Heater SH 1200 Functions based on circulating air, digitally controlled up to max. 40 C, serving to support and dry your component parts according to IPC J STD 033C. Item number 21001510 Humidity alarm signal lamp Two color (orange/green or red/green), magnetically fixed, providing optical signals on operational states and exceeded limit values. Operates on 24V. Item number 20016030 N 2 Autoflow system The autoflow system is developed to use in combination with a Totech drying cabinet. The device is used for the quick removal of moisture in the cabinet after the door has been opened. The drying pocess is realised by using nitrogen (N 2 ), which is added automatically after the door has been closed. (by means of adjustable timer function). Item number 22613066

Options ESD safe coated shelves 100% extractable (max 30 kg) Long version (W x D) 735 x 740 mm Item number 20011740 Short version (W x D) 735 x 580 mm Item number 20017401 Stainless steel shelves 100% extractable (max 30 kg) Long version (W x D) 735 x 740 mm Item number 2001742 Short version (W x D) 735 x 580 mm Item number 20011743 ESD safe coated shelves 100% extractable (max 50 kg) Long version (W x D) 735 x 740 mm Item number 20011747 Short version (W x D) 735 x 580 mm Item number 20011746 Stainless steel shelves 100% extractable (max 50 kg) Long version (W x D) 735 x 740 mm Item number 2001749 Short version (W x D) 735 x 580 mm Item number 20011748 U 5003 slave unit The drying unit U 5003 slave unit is in hardware the same as a standard U 5003. However, it is equipped with special software to enable communication between master and slave drying units. The main drying unit is equipped with an upgraded software as well. The communication between the drying units is established by means of a Y cable with 6 pole connectors. Item number 47005055

Options SMD Reel spring holder on extendable shelf The Reel spring holders are suitable for all types of reels. 4 pcs mounted on shelf. Item number 12001400 X Feeder system This feeder rack is suitable for Siemens X Feeder systems. Sold in combination with reel rack. Item number 46204004 S Feeder system This feeder rack is suitable for S Feeder systems. Sold in combination with reel rack. Item number 46204009 Hygroclip 2 Probe with maximum accuracy for all climate measurements. Item number 470000027 Exchange calibrated sensor: Item number 47000040 Humidity calibrator Hygropalm 22 Precision measuring device for calibrating sensors. Set including Hygroclip sensor, case and cable: Item number 20001019 Hygropalm only: Item number 20001016

Options MSL 2.0 software for 1000 components Software solution for the monitoring of moisture sensitive components and their MSL states during storage and processing in the production. The exact drying state individually for each component is monitored and displayed with the software. One of the possibilities is that it can read out multiple HC2A S sensors. To adjust storage conditions, picking of stock, removal of used parts and more stock control. A complete history for each component is traceable up to the full processing. The evaluation of the drying conditions is based on the requirements of the IPC / JEDEC J STD 033B1 directive. Item number 20010036 MSL software upgrade with additional 1000 components Upgrade to monitor an additional 1000 components Item number 200174502 Totech Monitor software Realtime cabinet monitoring with alarm function, sending e mails with detailed information on the status of the cabinet.history data files with graphical overview Item number 47000583 Ventilation channel MSD cabinet Used to connect multiple MSD cabinets Item number 21001800