Trends in High Efficiency HVAC Packaged Products May 2012

Similar documents
Product Release Summary

Submittal Data Performance Data Electrical Data

GUIDE SPECIFICATIONS - 48HC*D17-28

Bill McCullough. Director ERV Products. Dallas, TX

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

RT-OA TM Rooftop Outdoor-Air (DOAS)

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

Energy Recovery with Cooling and Heating Model ERCH

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Designing Energy Efficient Outdoor Air Systems

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

62DA,DB,DC,DD,DE,DF07-38

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Energy Recovery with Cooling and Heating

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Energy Recovery Ventilators

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

Direct Gas-Fired Make-Up Air Models DG and DGX

Submittal Summary Page

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

48PGD/E/F/L/M/N PG20-28

PAR5. Product Specifications

Advance Release September 2009

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS

Modular Supply Make-Up Air Unit

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Heat pump and energy recovery systems

The ultimate fresh air solution.

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

RGE 13 A T - 1 A

50TM TFF COMBINATION HEATING/COOLING UNITS

Energy Recovery Ventilation

48TF GAS HEATING/ ELECTRIC COOLING UNITS

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

White Paper. Executive Summary. Overview of Membrane Exchangers CLCH-PRB063A-EN. June 2017

Ruud Commercial Achiever Series Package Gas Electric Unit

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

THE ULTIMATE ROOFTOP SOLUTION

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

General HVAC Recommendations

AFD Industrial Dehumidifier Series

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Direct Gas-Fired Make-Up Air

Modular Heating & Ventilating Unit Model IGX-HV

Indirect Gas-Fired Make-Up Air

Adding More Fan Power Can Be a Good Thing

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

MiniCore Ventilator (500, 1000) Series Engineering Guide

Chilled Water DOAS Fan Powered Terminal Units

90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

THE RIGHT SPEC. RIGHT NOW.

48TM GAS HEATING/ELECTRIC COOLING UNITS

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

General Unit Specification Version: August 8, 2013 Model JDHA : DX High Outside Air Unit Page 1 of 14

General unit Specification Version: August 8, 2013 Model JDMA : Make-up / Ventilation Air Page 1 of 13

SKYPAK II, 3 Ton Series, gives you a

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV. Bard Manufacturing Company, Inc.

Application Data. Fig. 1 39M Unit with Energy Recovery Section

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

GUIDE SPECIFICATIONS 48LC**14-26

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

b.) Technical Information:

Q-Tec TM QC-Series Chilled Water Air Conditioner

WALL-MOUNT HEAT PUMPS - (60HZ)

SKYPAK II, 3 Ton Series, gives you a

RoofPak Applied Rooftop Systems

Product Data RELIABILITY FEATURES

MACH N-407 Heat Pump Air-Cooled Chiller

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Transcription:

Trends in High Efficiency HVAC Packaged Products May 2012

AGENDA Packaged commercial HVAC equipment and application overview Trends in high efficiency commercial packaged products Full load mechanical improvement challenges The importance of part load efficiency Technology enablers for energy savings Multi-speed technology Technology enablers for shedding peak load Demand Controlled Ventilation Energy Recovery Thermal Storage in packaged systems Gas Heat on Packaged units: energy saving strategies (heating)

AGENDA Packaged commercial HVAC equipment and application overview Trends in high efficiency commercial packaged products Full load mechanical improvement challenges The importance of part load efficiency Technology enablers for energy savings Multi-speed technology Technology enablers for shedding peak load Demand Controlled Ventilation Energy Recovery Thermal Storage in packaged systems Gas Heat on Packaged units: energy saving strategies (heating)

ROOFTOP UNIT OVERVIEW Control Box Indoor Coil Indoor Fan Gas Heat Condenser Coil Compressor Base Pan Base Rail

Evaporator ROOFTOP UNIT OVERVIEW Blower Heat Section Supply Return Barometric relief/exhaust Power Exhaust (if equipped)

PACKAGED UNIT APPLICATIONS

AHRI CERTIFICATION AHRI independent, 3 rd party verification of unit performance. Ensures manufacturer s performance claims are accurate and rated uniformly, enabling fair comparisons.

AHRI CERTIFICATION http://www.ahrinet.org/

AGENDA Packaged commercial HVAC equipment and application overview Trends in high efficiency commercial packaged products Full load mechanical improvement challenges The importance of part load efficiency Technology enablers for energy savings Multi-speed technology Technology enablers for shedding peak load Demand Controlled Ventilation Energy Recovery Thermal Storage in packaged systems Gas Heat on Packaged units: energy saving strategies (heating)

EFFICIENCY IMPROVEMENTS Significant improvements have been made in overall building efficiency as well as Packaged Rooftop Efficiencies Significant improvement has also been made for rooftop efficiencies, but we are approaching Max-Tech for EER. source: PNNL ASHRAE 90.1 Determination

EER EFFICIENCY IMPROVEMENTS 16 15 14 13 12 11 10 ASHRAE 90.1-1989 (Pre-2001) ASHRAE 90.1-2010 CEE Tier 1 CEE Tier 2 9 8 7 <5 tons 5 to 11.25 tons 11.25 to 20 tons 20 to 63.3 tons SEER IEER 13 12 11 10 ASHRAE 90.1-1989 (Pre-2001) ASHRAE 90.1-2010 9 CEE Tier 1 8 CEE Tier 2 PAC limits shown YAC subtract 0.2 7 5 to 11.25 tons 11.25 to 20 tons 20 to 63.3 tons

PART LOAD VS FULL LOAD Historic focus has been on full load efficiency - but that is less than 1% of the operating hours. Full load is important from peak kw but part load is where most of the hours are. Also, most units are oversized by at least 10% Latent control in humid zones contributes to increased power consumption in part load operation. Full Load Design Point The plot shows a typical hours load profile for an office building: ambient temperature vs load. source: PNNL ASHRAE 90.1 Determination Benchmark Model

IEER PART LOAD METRIC The IEER is intended to be a measure of merit for the part load performance of the unit. The equation is: IEER = 0.020*A + 0.617*B + 0.238*C + 0.125*D Where: A = EER at 100% net capacity at design conditions B = EER at 75% net capacity and reduced ambient C = EER at 50% net capacity and reduced ambient D = EER at 25% net capacity and reduced ambient The weighting factors were based on an average of the 17 ASHRAE climate zones for several building types. It includes the operating hours where the compressor is running and but does not include the hours where only economizers run. Each building may have different part load performance due to local occupancy schedules, building construction, building location and ventilation requirements. For specific building energy analysis an hour-by-hour analysis program should be used.

AGENDA Packaged commercial HVAC equipment and application overview Trends in high efficiency commercial packaged products Full load mechanical improvement challenges The importance of part load efficiency Technology enablers for energy savings Multi-speed technology Technology enablers for shedding peak load Demand Controlled Ventilation Energy Recovery Thermal Storage in packaged systems Gas Heat on Packaged units: energy saving strategies (heating)

ULTRA HIGH EFFICIENCY 3-5 TONS 1. Electrical mechanical controls or digital controls 3. High efficient direct drive ECM outdoor fan motor aids in unit overall high performance. 2 3 1 4 2. High Efficient Direct Drive ECM (x-13) or Belt Drive motor and Variable Frequency Drive (VFD) 4. Two-Stage scroll compressor provides efficient and accurate temperature control. Combined with digital controls system can provide Single Zone VAV logic and operation.

MULTI SPEED INDOOR FAN ASHRAE Standard Summary: As of January 1, 2012 all direct expansion Air Conditioners & Air Handlers >110k+ capacity serving single zones shall have two speed or variable speed drive indoor fan control. At cooling demands less than or equal to 50%, the supply fan controls shall be able to reduce the airflow to no greater than the larger of the following: 1. Two-Thirds of the full fan speed or, 2. The volume of outdoor air required to meet the ventilation requirements of Standard 62.1 (VFD) Speed Controller Carrier Fan Automatically Adjusts To Unit Operation Per New Standard ASHRAE 90.1 2010 Section: 6.4.3.10.b Indoor Fan Motor Belt Drive 2 Speed 1 st Stage Cooling = Fan at 67% 1 st and 2 nd Stage Cooling = Fan at 100% Any Heating = Fan at 100% Ventilation Only = Fan at 67%

MULTI SPEED INDOOR FAN Based on annual estimated electric energy savings utilizing Carrier s Hourly Analysis (HAP) Program v4.6. Based on cooling and ventilation fan runtime hours using ASHRAE 90.1 office application, default schedule, weather, and building data. Carrier model 48/50TC*D12. All locations except Los Angeles evaluated with a single dry bulb economizer, Los Angeles evaluated with differential enthalpy economizer.

AGENDA Packaged commercial HVAC equipment and application overview Trends in high efficiency commercial packaged products Full load mechanical improvement challenges The importance of part load efficiency Technology enablers for energy savings Multi-speed technology Technology enablers for shedding peak load Demand Controlled Ventilation Energy Recovery Thermal Storage in packaged systems Gas Heat on Packaged units: energy saving strategies (heating)

Evaporator ECONOMIZERS Fully Modulated 100% Closed Open No OA, all some return all RA return air is is recirculated air, exhausted some OA Blower No Outside Air Supply Return Barometric relief/exhaust Power Exhaust (if equipped) Must view this in presentation mode

ECONOMIZERS Alternate intake options OA Dampers Sliding panel

ECONOMIZERS Tampa, FL Syracuse, NY Free cooling opportunities

ECONOMIZER DCV SAVINGS Commercial building code requires continuous ventilation when occupied Building Ventilation for area + Occupancy Ventilation for people = Total ventilation rate Economizers with DCV can break the OA CFM into these two parts and reduce the ventilation load on the HVAC system, unless required by actual occupancy load.

ECONOMIZER DCV SAVINGS Purple = demand controlled Green = constant Difference between the two equates to significant savings. Bottom Line CO2 is a good people meter People exhale CO 2 at concentrations of 4% (40,000 ppm) Normal room concentrations are ~ 400-1200 ppm As a gas, CO 2 diffuses and equalizes rapidly throughout a room CO 2 production by people is very predictable based on activity level doubling the people in a room will double the CO 2 CO 2 levels will build until an equilibrium level is reached with outside air entering the space

ECONOMIZERS Great when then work Typical failure modes Not properly commissioned Broken linkage Seized dampers Control system failure Solution Factory installed Proper commissioning Integrated controls with feedback Gear driven design Gear driven design Fault diagnostics Proper maintenance, fault diagnostics Source: Jan2007 TAG/Public Interest Energy Research/Architectural Energy/CEC study (CEC- 500-2007-006) and Nov2008 TIAX/DOE study of Commercial Building Controls Diagnostics. (TIAX ref no. D0180

GEARS VS LINKAGE Older economizer designs had linkage that broke turning it into a manual air damper gear drives should be clearly specified. Gears Actuator connected to gear Linkage will eventually bind & break!

ALARM TOOLS i-vu Alarm Viewer Cell Phone/PDA Email Alarm Pop-up Get trouble indications where they needs to go: - The right people - facilities, service, operations - E-mail, texting, pop-up alarms

GRAPHICAL TOOLS OAT above 65 F Send Alarm Boiler ON when OAT is above 65 F Utilize trending to spot system operational issues

AGENDA Packaged commercial HVAC equipment and application overview Trends in high efficiency commercial packaged products Full load mechanical improvement challenges The importance of part load efficiency Technology enablers for energy savings Multi-speed technology Technology enablers for shedding peak load Demand Controlled Ventilation Energy Recovery Thermal Storage in packaged systems Gas Heat on Packaged units: energy saving strategies (heating)

WHAT IS ENERGY RECOVERY?

WHAT IS ENERGY RECOVERY? Energy Recovery = the use of exhaust air to partially condition the incoming OA before the evaporator coil Examples: Exhaust Air Desiccant heat wheel device Return Air Mechanical device (heat pump) Outside Air Mixed Air Ventilation Air Supply Air Fan Exhaust Air Return Air

INTEGRATED ENERGY RECOVERY Unit Airflow rear view Filters protect the wheel on each airstream. Rooftop Unit Indoor Fan RTU Heating Section Evaporator Mixed Air = RA2 + Outdoor Air Pre-cooled, dehumidified and/or heated Ventilation Air ERV module Enthalpy wheel Outdoor Air Exhaust Air Supply Air Return Air / Exhaust Air Diverter Dampers Return Air Replaceable Filters Airflow Sensing Module

INTEGRATED ENERGY RECOVERY TYPICAL SUMMER CONDITIONS TYPICAL WINTER CONDITIONS Operation: Wheel rotates between the incoming outdoor airstream and the building exhaust airstream. Transfers heat and moisture from one airstream to the other. Result = outdoor air is pre-conditioned, significantly reducing the capacity and energy needed from the mechanical HVAC system.

INTEGRATED ENERGY RECOVERY Energy Wheel Desiccant Design: Desiccants: How Do They Work? Water vapor in supply air stream is adsorbed on the desiccant Desiccants are man made materials with pore openings to adsorb certain type of vapors and gases. Because the vapor pressure in the colder exhaust air stream is lower the water vapor pressure on the desiccant surface, the water is de-sorbed and exhausted back to the outside Desiccant opening

TYPICAL OA REQUIREMENTS Building % OA Primary School 75 Secondary School 69 Retail 65 Strip Mall 62 Hospital 54 Outpatient Care 50 Small Office 46 Restaurant 36 Fast Food 34 Large Office 32 Medium Office 27 Warehouse 26 Hotel 23 Grocery 21 Motel 20 Table shows the typical outside air requirements that will be MANDATORY for a building designed to meet ASHRAE 90.1-2010 and ASHRAE 62.1-2010 requirements. Exact values can change based on the occupancy and space design. The energy recovery will impact building designs that need ~25% outdoor air or more. These applications cover ~ 75% of the industry applications. Use of ER reduces compliance complexity for designing engineers! ASHRAE 189 requires ER on applications with 5%-30% OA

ASHRAE CLIMATE ZONES Requirements by weather zone Zones 1A thru 6A will require ER on applications with 30% OA at 5,500cfm up to 70% OA at 1,000cfm

EER or CEF EFFICIENCY COMPARISON Energy recovery provides GREAT efficiency benefits when you need it most! Graph of CEF vs Application EER (Cooling Mode) Base Unit Application EER RTU+ERV System CEF - Tampa RTU+ERV System CEF - Detroit 23.0 21.0 19.0 17.0 15.0 13.0 11.0 9.0 7.0 5.0 80 85 90 95 100 105 110 115 120 125 Outdoor Air Temp (deg F) Example Base Rooftop Unit Base RTU w/integrated Energy Recovery Model: 48PGDC12-A-6 48PGDC12-A-6-T Altitude (ft) 0.0 ft 0.0 ft CFM 3500 3500 Ext static press: 0.75" 0.75" Ventilation Air: 50% or less (economizer) 50% OA (1750 CFM)

AHRI GUIDELINE V RTU Energy Efficiency Ratio ERV Recovered Energy Efficiency Ratio EER Net conditioni ng capacity of RTU Total electric power by RTU RER Net conditioni ng recovered by ERV Total electrical power consumed by ERV EER RER CEF = Combined Efficiency Factor (system EER) Example: 48HC-24 + Integrated Energy Recovery = System CEF (30 ton system) EER & RER = CEF 12.0 & 124.69 = 17.19 17.19 System EER for a 30 ton total system Reference: www.ahrinet.org/content/findaguideline_240.aspx

CEF EXAMPLES Atlanta Miami Phoenix Montreal Detroit Rooftop Unit RTU AHRI EER ERV Wheel RTU Airflow (CFM) ERV Airflow (CFM) ERV RER 48HC 17 12.0 ERC-3628 5250 3800 68.67 16.60 80.82 17.59 61.82 16.05 43.08 14.52 55.58 15.54 48HC 20 12.0 ERC-3628 5950 3800 68.67 16.01 80.82 16.87 61.82 15.52 43.08 14.20 55.58 15.08 48HC 24 12.0 ERC-4646C 7000 5500 76.27 17.19 89.95 18.29 68.73 16.58 47.97 14.90 61.80 16.02 48HC 28 11.2 ERC-4646C 8750 5500 76.27 15.38 89.95 16.25 68.73 14.89 47.97 13.56 61.80 14.45 CEF ERV RER CEF ERV RER CEF ERV RER CEF ERV RER CEF Atlanta Miami Phoenix Montreal Detroit Rooftop Unit RTU AHRI EER ERV Wheel RTU Airflow (CFM) * CEF equates to a system EER value ERV Airflow (CFM) ERV RER 50HC 17 12.2 ERC-3628 5250 3800 68.67 16.86 80.82 17.86 61.82 16.29 43.08 14.75 55.58 15.78 50HC 20 12.2 ERC-3628 5950 3800 68.67 16.26 80.82 17.13 61.82 15.76 43.08 14.42 55.58 15.32 50HC 24 12.2 ERC-4646C 7000 5500 76.27 17.45 89.95 18.57 68.73 16.83 47.97 15.13 61.80 16.27 50HC 28 11.4 ERC-4646C 8750 5500 76.27 15.63 89.95 16.53 68.73 15.14 47.97 13.79 61.80 14.69 CEF ERV RER CEF ERV RER CEF ERV RER CEF ERV RER CEF In example cities systems experience up to 6.37 efficiency point boost, with an average increase of 4 points of efficiency!

APPLICATION COMPARISON Design Conditions (St. Louis IAP) High Eff 20 ton 48HCDD24 High Eff 25 ton 48HCDD28 EnergyX System 48HCDD24 Airflow (CFM) 8000 8000 8000 8000 Ventilation Air (CFM) 4000 4000 4000 4000 OA (db/wb o F) 95 / 76 95 / 76 95 / 76 95 / 76 RTU Evap EAT (db/wb o F) RTU Evap LAT (db/wb o F) Total Cooling Capacity (MBH) - 85 / 70 85 / 70 79/66 58 / 57 62 / 61 60 / 59 58/57 325 264 312 359 Sensible Capacity (MBH) 215 195 217 243 Total Heating Capacity (MBH) 300 251 251 498 Unit Efficiency - 12 EER 11.2 EER 17.66 Effectively doubled heating Capacity with constant gas bill

ENERGY RECOVERY REBATES Example: Florida Power & Light www.airxchange.com/airxchange-technology-utility-rebates.htm Florida Power and Light offers incentives for its business customers to upgrade their HVAC system and lighting system with energy-efficient equipment. The individual rebates vary according to system size and efficiency rating; ERV rebates up to $1.35 per CFM. Typical is ~ $0.8 to 0.9 per CFM. Example: 10 ton High Efficiency Rooftop + EnergyX System at 2000 CFM ~ $1,840 rebate Details: http://www.fpl.com/business/energy_saving/programs/interior/ventilation.shtml Enthalpy wheel or plate type ERV system which recovers both sensible and latent heat from the building exhaust Desiccant or moisture transfer membranes for humidity control AHRI certified and listed with 50% net total thermal effectiveness rating

ENERGY RECOVERY Great when it works! Typical failure modes Unverified performance Poor installation Not properly commissioned Poor air balance Dirty transfer media Solution Factory integrated and certified Factory integrated Factory installed Proper commissioning Integrated controls with monitoring and feedback Integrated airflow monitoring Removable media for clean-ability

INTEGRATED ENERGY RECOVERY

INTEGRATED ENERGY RECOVERY Onboard airflow monitoring Differential pressure sensed across window opening Correlation between differential pressure and CFM Intake/exhaust fans modulate Backward curved Direct drive ECM motors *Aluminum mist filter removed for photo Drive Actual CFM = Commanded CFM

INTEGRATED ENERGY RECOVERY Ease of Set-Up Enter: Commanded Exhaust Commanded Intake System: Modulating fans Intake damper Onboard airflow monitoring System works to balance actual and commanded Factory integrated system and controls

INTEGRATED ENERGY RECOVERY Ease of Service Easy access door Filters slide out Wheel slides out Segmented wheel for easy cleaning* *Wheels greater than 25

EASE OF SERVICE Segmented wheel facilitates cleaning 1. Segments are removed through access panels 2. Segment is soaked in alkaline cleaner ( 409 or Fantastic ) 3. Segment is rinsed and drained 4. Segment is dried and ready for use

INTEGRATED ENERGY RECOVERY Factory engineered Factory integrated ETL listed system One warranty One service support team

INTEGRATED ENERGY RECOVERY Selectable Options Economizer option allows true modulating economizer capability when OA is suitable for free cooling operates as a true wheel bypass damper uses stop/jog operation for wheel Frost control option uses exhaust air to defrost the wheel when necessary Demand Controlled Ventilation - Modulating Integrated Energy Recovery Systems units are compatible with single zone CO2 sensor

AGENDA Packaged commercial HVAC equipment and application overview Trends in high efficiency commercial packaged products Full load mechanical improvement challenges The importance of part load efficiency Technology enablers for energy savings Multi-speed technology Technology enablers for shedding peak load Demand Controlled Ventilation Energy Recovery Thermal Storage in packaged systems Gas Heat on Packaged units: energy saving strategies (heating)

THERMAL STORAGE * *Based on use of nighttime wind energy and lower source emitting generation equipment

THERMAL STORAGE Seth Mohler 303-944-6274 smohler@carrierwest.com

AGENDA Packaged commercial HVAC equipment and application overview Trends in high efficiency commercial packaged products Full load mechanical improvement challenges The importance of part load efficiency Technology enablers for energy savings Multi-speed technology Technology enablers for shedding peak load Demand Controlled Ventilation Energy Recovery Thermal Storage in packaged systems Gas Heat on Packaged units: energy saving strategies (heating)

PACKAGED SYSTEMS- HEATING Challenges Opportunities Higher gas efficiency (AFUE) Energy recovery High Efficiency Heat pumps Fan savings

PACKAGED SYSTEMS- HEATING Residential vs. Commercial There are significant application differences between commercial and residential In commercial, the indoor fan is always on during the occupied period due to ventilation requirements as defined by ASHRAE 62.1 Commercial applications tends to have much higher cooling loads due to internal plug loads which can be 25 to 30% of the load plus the internal occupancy density is much higher Commercial buildings like offices tend to use time of day schedule where the unit is off or setback during the evening where residential tends to be operating at design temperatures during the evening Cooling/Heating Changeover temperatures are much lower and cooling dominates the commercial market and heat to cool ratios are lower

% Load (Cooling and Heating) PACKAGED SYSTEMS- HEATING Residential vs. Commercial The chart shows a typical Commercial office building load profile and a Residential Load Profile 120 100 80 Residential Load Profile Commercial Office Load Profile 60 40 20 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 Ambient Temperature (F)

PACKAGED SYSTEMS- HEATING Condensate Disposal Because of the acidic nature of the condensate you can not drain it on the roof or the ground. For ground mounted units which is 20 to 30% of the market it would be difficult to drain the condensate as it might be below the level of the sewer lines Many commercial codes do not allow it to be drained into the sewer system Also heating is used when the ambient is below freezing and the condensate lines and condensate will freeze

PACKAGED SYSTEMS- HEATING Rooftop unit airflow review Control Box Indoor Coil Indoor Fan Gas Heat Condenser Coil Base Pan Base Rail Compressor

PACKAGED SYSTEMS- HEATING Impact and Findings 0.10 incremental pressure drop currently not possible and will require new technology and increased cabinet sizes Corrosion issues and condensate disposal are still an issue. Increasing plug loads and tighter buildings with higher insulation levels the benefits will continue to decrease Some older buildings may have higher heating loads, but should we develop condensing furnace technology to fix bad buildings or should we fix the buildings with energy retrofits which will reduce energy more

REFERENCE

EXAMPLE ENERGY RECOVERY SPEC 1. Energy Recovery Ventilator and Economizer a. System Description One-piece Energy Recovery Ventilation (ERV) System is an electrically controlled ventilation air pre-conditioner utilizing an AHRI 1060 certified Energy Recovery Cassette to reduce the cooling and heating loads placed on the primary HVAC unit by untreated outdoor air. Building exhaust air shall be introduced to the ERV unit through ductwork. Unit shall be designed as a factory-installed option to be used with packaged rooftop units for use in vertical return applications only. b. Quality Assurance (1.) Unit shall be designed in accordance with UL Standard 1995 (2.) Energy Recovery unit shall be ETL tested and certified. (3.) Rooftop unit and Energy Recovery unit shall be ETL certified as one single system. (4.) Roof curb or curb extension shall be designed to conform to NRCA Standards. (5.) Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. (6.) Unit casing shall be capable of withstanding ASTM No. 141 (Method 6061) 500-hour salt spray test. (7.) Unit shall contain ARI 1060 certified Energy Recovery Cassette. (8.) Unit shall leakage rates shall be capable of meeting ASHRAE Standard 62.1 requirements for use of class-2 exhaust with class-1 ventilation air. 2. Products a. Equipment (Standard) (1.) General The Energy Recovery System shall be a factory assembled, single piece unit. Contained within the unit enclosure shall be all factory wiring with a single, pre-determined point of power input and a single point of 24-volt control wiring. b. Unit Cabinet (1.) Unit cabinet shall be constructed of galvanized steel coated with a pre--painted baked enamel finish. (2.) All models shall have hoods installed over outside air intake and exhaust openings. Outside air hood shall have aluminum water entrainment filters. (3.) All models have 1-in., 2 pound density fiberglass insulation. (4.) Hinged access doors with compression latches shall be provided on all units for access to fans and filters. Hinged doors shall be provided with at least one handle capable of being locked. (5.) Exhaust air stream shall have back-draft dampers to prevent air penetration during off cycles. (6.) Holes shall be provided in the base rails for rigging shackles to facilitate overhead rigging. c. Blowers (1.) Blowers shall be direct drive with variable speed motors. (2.) Blower wheel shall be made of steel with a corrosion resistant finish. It shall be dynamically balanced, double-inlet type with backward-curved blades. (3.) Blower shall be mounted on neoprene vibration isolation pads. (4.) Motor shall be high efficiency and have thermal overload protection. d. Filter Section (1.) Standard filter section shall accept commercially available, 2-in. pleated filter(s). e. Controls and Safeties (1.) The Energy Recovery Ventilator shall operate in conjunction with rooftop unit fan. f. Electrical Requirements (1.) All unit power wiring shall enter unit cabinet at a single location. g. Energy Recovery Cassette (1.) The energy recovery media shall have a minimum of 70% effectiveness at nominal unit airflow. (2.) Energy wheel performance shall be ARI Standard 1060 Certified and bear the ARI Certified Product Seal. (3.) The energy recovery cassette shall be an UL Recognized component for electrical and fire safety. (4.) The wheel shall be coated with silica gel desiccant, permanently bonded without the use of binders or adhesives. (5.) Coated wheels shall be washable with detergent or alkaline coil cleaner and water. (6.) The silica gel shall not dissolve or deliquesce in the presence of water or high humidity. (7.) The substrate shall be made of a lightweight polymer and shall not degrade or require additional coatings for application in coastal environments. (8.) The wheel polymer layers shall be wound continuously with one flat and one structured layer in an ideal parallel plate geometry providing laminar flow and minimum pressure drop. (9.) The polymer layers shall be captured in a stainless steel wheel frame or aluminum and stainless steel segment frames that provide a rigid and self-supporting matrix. (10.) Energy recovery wheels greater than 19 inches in diameter shall be provided with removable wheel segments. (11.) Wheel frame shall be a welded hub, spoke and rim assembly of stainless, plated, and or coated steel and shall be self supporting without the wheel segments in place. (12.) Wheel segments shall be removable without the use of tools to facilitate maintenance and cleaning. (13.) Wheel rim shall be continuous rolled stainless steel and the wheel shall be connected to the shaft by means of taper locks. (14.) Wheel bearings shall provide an L-10 life of 400,000 hours. (15.) Drive belts of stretch urethane shall be provided for wheel rim drive without the need for external tensioners or adjustment. 2. Special Features (Options and Accessories) a. Supply and exhaust air frost control option (1.) Factory-installed frost protection module shall sense pressure differential across the energy recovery cassette. (2.) Supply blower shall be shut-off if the pressure differential across the energy recovery cassette exceeds an adjustable set point. Blower shall remain off for an adjustable time period. (3.) Exhaust blower and wheel shall remain in operation in order to remove any frost build-up on the wheel. b. Energy Recovery Ventilator maintenance indicator package (1.) A factory-installed switch shall monitor Energy Recovery Ventilator blowers and wheel motor amp draw and send a signal to field-supplied 24-v indicator upon amperage surge that maintenance required. c. Filter maintenance indicator (1.) A factory-installed differential pressure switch shall measure pressure drop across the outside air filter and activate a field-supplied 24-v indicator when airflow is restricted. It shall not interrupt Energy Recovery System operation. Switch set point shall be adjustable. d. Energy Recovery Ventilator free cooling with enthalpy and stop/jog control (1.) An enthalpy sensor shall prevent the wheel from rotating if the outside air conditions are acceptable for free cooling. Both exhaust and supply blowers will remain on. (2.) Stop-Jog-Control shall energize the wheel periodically during the free cooling operation of the Energy Recovery Ventilator to prevent dirt build-up on the wheel. e. Economizer Option (1.) The economizer shall be integrated in the energy recovery module and shall allow air to bypass the energy recovery wheel for free cooling and fail safe operation. Tilting wheel mechanisms shall not be allowed. (2.) The economizer damper shall be motorized with factory installed, 24-volt Belimo actuator. (3.) The energy recovery system shall be capable of using the economizer in a free cooling operation. (4.) The economizer shall utilize enthalpy sensor controls when in the economizer mode. f. CO 2 Sensor (1.) The modulating airflow energy recovery unit shall be capable of incorporating a CO 2 sensor for use with Demand Control Ventilation. (2.) The CO 2 sensor shall connect to the base rooftop unit s digital controller. (3.) The modulating airflow energy recovery unit shall use at a minimum, a high & low CFM airflow set point when a CO 2 sensor is used.

DIAGNOSTICS REPORTS