Icopal Screw Fasteners & Accessories

Similar documents
WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

MECHANICAL FIRE STOPPING SOLUTIONS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

TECHNICAL. Design Guide. Retaining walls made easy with this beautiful solution EARTH RETAINING WALLS

NOPHADRAIN RO O F DE C KS. The inverted roof, a sound construction for roof decks! GREEN ROOFS PODIUM ROOF DECKS PARKING ROOF DECKS

SYSTEM OVERVIEW UTILITY ROOFDECKS GREEN ROOFS PODIUM ROOF DECKS PARKING ROOF DECKS 0.1

1. RETAINING WALL SELECTION PROCEDURE

Cylinders and Key Systems

flat green roof structures

asphalt applications European Asphalt Standards and their application in the UK mpa asphalt Asphalt Information Service Mineral Products Association

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

SPIDER P SPIDER P mineral

FLAGON PVC FLAGON SV ROOFING SYNTHETIC MEMBRANES

4 1 Heating. wooden floors or renovated floors.

Underfloor Heating Mat Installation Manual

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

CI/SfB (57.5) November 2008

FILTER PRESS TECHNOLOGY HIGH PERFORMANCE DEWATERING APPLICATIONS FOR MINING

Technical Checklist - Plumbing and Heating Fittings - UK Sizes

IMPORTANT NOTES. Electric Underfloor Heating Mats For use with Touchsceen underfloor heating Thermostat

Smoke extract fan SMHA HATCH

Underfloor Heating Cable Installation Manual

2.2 Factors in design

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

INSTALLATION AM

Visqueen Vapour Control Tapes

PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series Sleeves

A PVC geomembrane integrated in the landscape

Varsity Exposed Shower Systems

Straightening STRAIGHTENING

Site guidance for working in root protection zones

Installation & Service Guide

INFRARED BUILDING HEATING BOARDS

Multilux 4-Eclipse-Set

Roofing Adhesive SARNACOL 2172 Spray

Furring Channel Resilient Mount - Direct Fixing. Ceiling Systems. intex.com.au / intex.co.nz. Intex

Bristol University Auditorium, Bristol

SHOWER TRAY SELECTOR - LEVEL ACCESS SHOWER TRAYS

DRAFT PLANNING GUIDE. System Solutions for Intensive Green Roofs

Pedimat Installation Instructions

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

Paper presented at the International Symposium on Protection of Cultural Heritage Buildings from Fire, Kyoto, Japan, April 6 7, 2003

Green Roof Fact Sheet

UNDERFLOOR HEATING GUIDE

TANDEM TANDEM. Premium concealed runners for wood drawers.

DAVITS INFORMATION & CERTIFICATION

Annex of the certificate (Page 1/5) Accreditation Scope

Tubular Heaters Series

BIOGAS BIOGAS AGITATORS. Our product range for increased biogas production

Principles of Cold Insulation

Civil engineering Fibertex Geotextiles

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

When Precision is not good enough

EARTH STABILIZATION GEOSYNTHETIC SOLUTIONS

Primary functions Primary planting General System Type Maintenance Required Roof construction Plant Layer Suitable application

Model Dimensions Coverage 230v 230Vac. Pack Contents. Measuring Up

Dimensions: 39 1/2" w x 22" D x 35.5 H. kk25 installation. Things you might need for the installation: vessel sink,

Contact Details. Please note that some of the contact details on this PDF document may not be current.

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

Thermotech underfloor heating

Efficiency in the smallest space

Showering Accessories

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

NATURAL VENTILATION CONTROL SYSTEMS

Instruction Manual. Orayonne. Glass radiation heater

Drill-Tec TM Fastener Selection Guide

Installation and Safety Instructions Cone Wall Light with PIR Stainless Steel Model: S083S

Easdale International INFINITY

GEOMEMBRANE FIELD INSTALLATION

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

Bellman Ground Farm House Storrs Park, Bowness on Windermere

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Installation Manual. Top of Pole Mount Edition v1.01. For models:

kk21 installation Kk21-WF21 Things you might need for the installation: vessel sink,

FUNCTIONAL REQUIREMENTS

PRODUCT LISTING Tubular Heater Finned Heater

Metal Cassette Ceiling with BEKA Heating and Cooling Mats

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

This garden was created in recognition of Yvonne s enormous commitment to the Red Cross and to provide a spot for her to relax and unwind.

EQUIPMENT FOR OIL/PAPER DRYING AND STABILIZATION

VENTILATION DESIGNED FOR CARE HOMES

Terminal Automation Solutions

FIREPRO FIRESTOPPING AND PENETRATION SEALS PRODUCT GUIDE

NATURAL AND ENERGY-EFFICIENT VENTILATION SYSTEMS FOR DOMESTIC BUILDINGS

Ballast Paver Design & Installation Guide

ARCHIVED DOCUMENT. Energy efficiency primer GOOD PRACTICE GUIDE 171 BEST PRACTICE PROGRAMME

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS

Twin Wall Installation Instructions And Maintenance Guide

Thermostatic valves with radiator connection systems

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Break Layers. A guide to the design and specification of capillary break, salt barrier and frost barrier layers.

CLEARPOINT THE WINNING COMBINATION FOR CLEAN COMPRESSED AIR

INSPIRED GARDEN ROOMS

Smoke Master SMIA Compact pressurisation and smoke exhaust system

The Laboratory is qualified to update standards identifying the test procedures.

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO

Centrif Duo & Centrif Duo Plus

Made to Measure Window Furnishings

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Transcription:

CI/SfB January 2015 (47) t6 Uniclass L524<L671222 Issue 03 & Accessories A Range of Tubular Washers, Plates and Screw Fasteners Introduction A range of specialist fasteners for securing thermal insulation and Icopal single-ply roof waterproofing membranes to a variety of structural roof decks including steel, concrete and timber. Icopal Tubular Washers Icopal Tubular Washers are precision moulded from high grade polypropylene and extensively tested to ensure resistance to the extreme temperatures and mechanical stresses encountered within the roofing system. They are blue in colour and are available with two washer diameters: A 45 mm diameter for fixing membranes and a 75 mm diameter for fixing rigid insulation boards. are manufactured from high grade carbon steel which are case hardened to achieve the properties essential for long term performance and have an organic corrosion resistant finish to meet UEAtc Part 2 requirements. The fasteners are also available in austenitic stainless steel offering exceptional corrosion resistance for extended warranty projects. Icopal Stress Plates Icopal Stress Plates are manufactured from high quality carbon steel. Icopal Stress Plates are for use where tube washers cannot be utilised or where the membrane is being fastened without insulation present, eg cold roof situations. Properties Fastener Composition Stainless Steel or Carbon Steel Head Form T-25 Recess Steel, 0.75 mm Plywood, 18 mm Typical Pull Out Value 1.29 kn 1.28 kn Icopal Tubular Washers Colour Material Washer Diameter Membrane Tube Washer: Insulation Tube Washer: Blue Polypropylene 45 mm diameter 75 mm diameter Icopal Stress Plates Material Shape Plate Diameter: 82 mm x 40mm Carbon Steel Oval - 1 -

Application: For fastening insulation and membrane to steel and timber decks. Used in Combination With: Icopal R45 Membrane Tube Washer. Icopal R75 Insulation Tube Washer. Icopal Stress Plates. Features: High performance drill tip ensures highest possible pull out resistance. Unique Duroguard coating for excellent corrosion resistance. Torx 25 recess head style. Drillpoint designed for self-drilling into steel deck. Fastener 3100924 Icopal BS-4.8/50 50 1000 3100925 Icopal BS-4.8/60 60 500 3100926 Icopal BS-4.8/70 70 500 3100927 Icopal BS-4.8/80 80 500 3100928 Icopal BS-4.8/90 90 500 3100929 Icopal BS-4.8/100 100 500 3100930 Icopal BS-4.8/110 110 500 3100931 Icopal BS-4.8/120 120 500 3100932 Icopal BS-4.8/130 130 500 3100933 Icopal BS-4.8/140 140 500 3100934 Icopal BS-4.8/150 150 500 3100935 Icopal BS-4.8/170 170 500 3100936 Icopal BS-4.8/190 190 250 Fastener 3100937 Icopal BS-4.8/200 200 250 3100938 Icopal BS-4.8/220 220 250 3100939 Icopal BS-4.8/240 240 250 3100940 Icopal BS-4.8/260 260 250 3100941 Icopal BS-4.8/300 300 250 3100942 Icopal BS-4.8/320 320 250 3100943 Icopal BS-4.8/360 360 250 Recommended minimum fastener penetration Steel decking, minimum 0.63 mm to maximum 2x1.25 mm thick: Plywood/OSB3, minimum 18 mm: Timber decking, minimum 25 mm thickness: Timber joist or rail: 20 mm through underside 12 mm through underside 12 mm through underside 35mm embedment Note: For timber deck applications a site pull-out test is recommended. - 2 -

Icopal BS-S-4.8mm Stainless Steel Fastener Application: For fastening insulation and membrane to steel and plywood or OSB decks. For use where the internal relative humidity is in excess of 65%, or for locations with aggressive local conditions (e.g. coastal environments). For refurbishment applications where the detailed condition of the existing build up is not known. Where an extended design life / warranty is required by the client. Used in Combination With: Icopal R45 Membrane Tube Washer. Icopal R75 Insulation Tube Washer. Icopal Stress Plates. Features: High performance drill tip ensures highest possible pull out resistance. Austenitic stainless steel, grade AISI 316 European Standard 1,4401, grade A4. Torx 25 recess head style. Drillpoint designed for self-drilling into steel deck. Fastener 3100944 Icopal BS-S-4.8/60 60 500 3100945 Icopal BS-S-4.8/80 80 500 3100946 Icopal BS-S-4.8/100 100 500 3100947 Icopal BS-S-4.8/120 120 500 3100948 Icopal BS-S-4.8/140 140 500 3100949 Icopal BS-S-4.8/160 160 500 3100951 Icopal BS-S-4.8/180 180 500 3100952 Icopal BS-S-4.8/200 200 250 Icopal BS-S-4.8mm Stainless Steel Fastener Recommended minimum fastener penetration Steel decking, minimum 0.63 mm to maximum 2x1.0 mm thick: Plywood/OSB3, minimum 18 mm: 20 mm through underside 12 mm through underside - 3 -

Icopal TI-T25 Carbon Steel Fastener Application: For fastening insulation and membrane to concrete decks. Used in Combination With: Icopal R45 Membrane Tube Washer. Icopal R75 Insulation Tube Washer. Icopal Stress Plates. Features: Unique Duroguard coating for excellent corrosion resistance. Torx 25 recess head style. 6.3 mm diameter thread form. Fastener 3100953 Icopal TI-T25/32 32 250 3100954 Icopal TI-T25/50 50 250 3100955 Icopal TI-T25/60 60 250 3100956 Icopal TI-T25/70 70 250 3100957 Icopal TI-T25/80 80 250 3100959 Icopal TI-T25/90 90 250 3100960 Icopal TI-T25/100 100 250 3100961 Icopal TI-T25/120 120 250 3100962 Icopal TI-T25/160 160 250 Icopal TI-T25 Carbon Steel Fastener Recommended minimum fastener penetration Structural concrete: 20 mm embedment. Pilot hole depth should be 10 25 mm greater than fastener embedment to allow for sediment. Note: A site pull-out test is recommended, which will determine the optimum pilot hole. - 4 -

Icopal TI-S-Z10 Stainless Steel Fastener Application: For fastening insulation and membrane to concrete structural decks. For use where the internal relative humidity is in excess of 65%, or for locations with aggressive local conditions (e.g. coastal environments). For refurbishment applications where the detailed condition of the existing build up is not known. Where an extended design life / warranty is required by the client. Used in Combination With: Icopal R45 Membrane Tube Washer. Icopal R75 Insulation Tube Washer. Icopal Stress Plates. Features: Austenitic stainless steel, grade AISI 304 European Standard 1,4301, grade A2. SQ3 recess head style. Ø 7,9 mm head diameter. Fastener 3100963 Icopal TI-S-Z10/45 45 100 3100964 Icopal TI-S-Z10/75 75 100 3100965 Icopal TI-S-Z10/115 115 100 Icopal TI-S-Z10 Stainless Steel Fastener Recommended minimum fastener penetration Structural concrete: 20 mm embedment. Pilot hole depth should be 10 25 mm greater than fastener embedment to allow for sediment. Note: A site pull-out test is recommended, which will determine the optimum pilot hole. - 5 -

Icopal TIA-T25-6.3mm Carbon Steel Fastener Application: For fastening tapered insulation schemes and membrane to concrete structural decks. Used in Combination With: Icopal R45 Membrane Tube Washer. Icopal R75 Insulation Tube Washer. Icopal Stress Plates. Features: Unique Duroguard coating for excellent corrosion resistance. Torx 25 recess head style. Ø 9,6 mm head diameter. Optimum installation system for tapered insulation schemes. The same fastener and sleeve combination can typically be used for insulation boards differing by up to 100mm in thickness. Fewer combinations of fasteners are required. Fastener 3100966 Icopal TIA-T25/70 70 100 3100967 Icopal TIA-T25/90 90 100 3100968 Icopal TIA-T25/120 120 100 3100969 Icopal TIA-T25/150 150 100 Icopal TIA-T25-6.3mm Carbon Steel Fastener Recommended minimum fastener penetration Structural concrete: 20 mm embedment. Pilot hole depth should be 10 25 mm greater than fastener embedment to allow for sediment. Note: A site pull-out test is recommended, which will determine the optimum pilot hole. - 6 -

Icopal Tubular Washers Composition Icopal Tubular Washers are blue in colour and precision moulded from high grade polypropylene and extensively tested to ensure resistance to the extreme temperatures and mechanical stresses encountered within the roofing system. The Icopal Tubular Washer System offers many benefits over other traditional fastening methods. Membrane protection Foot traffic or other loads applied to the roof surface can often force the fastener head to pop through the membrane as the insulation beneath compresses. This causes damage to the waterproofing membrane and therefore potential roof leaks into the structure. Thermal transmittance Traditional fastener and metal plate combinations create a path for heat loss from the inside of the building to the outside atmosphere. This seemingly small thermal bridge creates significant heat loss. This loss has to be factored in when calculating U-values to BS EN ISO 6946. This can result in an increase in the insulation thickness to compensate. The Icopal Tubular Washer eliminates this thermal transmittance thereby allowing a reduced thickness of insulation. Insulation thickness Regulations are constantly being upgraded to help reduce a building s carbon usage, leading to thicker insulation being required. Thicknesses of up to 595 mm can easily be accommodated with the Icopal Tubular Washer and Screw Fastener combination. Eliminate unwinding forces The cyclic nature of wind uplift on flat roofing systems can cause standard fastening methods to unwind. Icopal Tubular Washers and Screw Fasteners can allow this cyclic action to occur without causing the fastener to unwind. The telescopic action of a tube and fastener combination that is not locked together removes the risk of the fastener being pushed through a thin deck by foot traffic or materials being placed on the roof surface. - 7 -

Icopal Tubular Washers Profile The Icopal Tubular washer s round design which together with a narrow diameter tube ensures a quick installation. They are available with two washer diameters: A 45 mm diameter for use when fixing membranes, and a 75 mm diameter for use when fixing rigid insulation boards. Icopal R75 Insulation Tubular Washer Tube 3100970 Icopal R75/35 35 500 3100971 Icopal R75/65 65 500 3100972 Icopal R75/85 85 500 3100973 Icopal R75/105 105 500 3100974 Icopal R75/135 135 500 3100975 Icopal R75/165 165 250 3100976 Icopal R75/185 185 250 3100977 Icopal R75/195 195 250 3100978 Icopal R75/225 225 250 3100979 Icopal R75/255 255 250 3100980 Icopal R75/285 285 200 Icopal Membrane Tubular Washer (45 mm diameter) Icopal Insulation Tubular Washer (75 mm diameter) Icopal R45 Membrane Tubular Washer Tube 3100981 Icopal R45/15 15 1000 3100982 Icopal R45/35 35 500 3100983 Icopal R45/65 65 500 3100984 Icopal R45/85 85 500 3100985 Icopal R45/105 105 500 3100986 Icopal R45/135 135 500 3100987 Icopal R45/165 165 500 3100988 Icopal R45/185 185 500 3100989 Icopal R45/195 195 500 3100990 Icopal R45/225 225 250 3100991 Icopal R45/255 255 250 3100992 Icopal R45/285 285 250 3100993 Icopal R45/325 325 250 3100994 Icopal R45/365 365 250 3100995 Icopal R45/405 405 250-8 -

Icopal Stress Plates Introduction There are often situations when the Icopal Tubular Washers cannot be utilised, for example when the membrane is not being fastened directly to insulation, such as in a cold roof situation, or when fastening membrane which is applied directly to a plywood overlay. For these situations the Icopal Stress Plates are used. These plates are purpose-designed for use with fasteners from the Icopal range and are manufactured from from a high quality carbon steel. If further advice is required please contact s Technical Services for guidance. Icopal IRC/W-82x40mm Stress Plate for general use when fixing waterproofing membrane, such as in seam, laid directly above plywood or OSB. Examples of Typical Usage Cold Roof Application (timber deck) Suitable Fasteners: Seam Plate Type: Icopal IRC/W-82x40mm Stress Plates Warm Roof Insulation with Plywood Overlay Suitable Fasteners: (to suit structural deck type) Seam Plate Type: Icopal BS-S-4.8mm Stainless Steel Fastener Icopal TI-T25 6.3mm Carbon Steel Fastener Icopal IRC/W-82x40mm Stress Plates Membrane Overlay above Soft Insulation (eg mineral wool) Suitable Fasteners: (to suit structural deck type) Icopal BS-S-4.8mm Stainless Steel Fastener Icopal TI-T25 6.3mm Carbon Steel Fastener Seam Plate Type: Icopal IRD/82x40mm Stress Plates Icopal IRD/82x40mm Stress Plate for use when fixing waterproofing membrane in seam, over insulation Icopal Stress Plates Item Code Pressure Plate TBC IIcopal IRC/W-82x40mm Stress Plates 100 TBC Icopal IRD-82x40mm Stress Plates 100-9 -

Guidance Notes examples only Selecting the correct tube washer To optimize the benefits of the Icopal Tubular Washer system, ideally use the maximum length of tube washer and the minimum fastener length available. In certain applications, such as over-roofing of existing membrane and insulation layers, different tube lengths may be required. The tube washer should be chosen first; then the fastener can be selected. To select the maximum tube length (C) : i) deduct minimum 15 mm from the total build-up of the roof insulation (A) to allow for compression of the insulation (B). ii) choose the tube washer of that length or shorter. eg, For an insulation buildup of 140 mm, the maximum tube length would be 125 mm, and so a 105 mm long Tube Washer would be chosen. Total Roof System build-up (A) Deduct compression tolerance (B) Maximum tube length 140 mm -15 mm 125 mm Chosen tube length (C) 105 mm Selecting the correct fastener length When selecting the correct Icopal Screw Fastener length, allow for the recommended minimum deck penetration or embedment and take into consideration the total build-up of the roof system, including any pressure plate, membrane, separation layers insulation, vapour barriers, existing systems and structural deck. Key: A: Total roof buildup depth B: Insulation compression tolerance ( min 15 mm) C: Tube Washer length D: minimum deck penetration or embedment E: min 20mm allowance for fastener in tube F: Fastener length To select the optimum fastener length (F) for tube washer applications: eg, For a 140 mm build-up over 0.7mm steel deck using a 105 mm tube the minimum fastener length would be 70 mm. i) take the total roof system build-up measurement (A) and deduct the selected tube length (C). ii) iii) allow for deck penetration (D) and then add minimum 20 mm allowance for the fastener within the tube (E). select the fastener at this length or longer. Total roof system build-up (A) Deduct selected tube length (C) Add min. deck penetration/embedment (D) Add allowance for fastener within tube (E) Minimum fastener length (F) 140 mm -105 mm +15 mm +20 mm 70 mm - 10 -

Guidance Notes examples only Washer/Fastener Combinations The following tables are provided as a quick reference guide for calculating the required tube washer and fastener combination for a new warm roof direct to deck. The thickness of structural deck used for the combination is indicated for each table. The fastener length should be altered accordingly where the structural deck thickness or system build-up is different. See previous page for further information. Example, 0.7 mm metal deck Example, 18 mm plywood deck Metal Deck Application Structural Deck: Minimum deck penetration: 0.7mm steel 20 mm though underside Suitable Fasteners: Icopal BS-S-4.8mm Stainless Steel Fastener Tube Washer Type: Icopal R45 Membrane Tube Washer Icopal R75 Insulation Tube Washer Plywood Deck Application Structural Deck: Minimum deck penetration: 18mm plywood 12 mm though underside Suitable Fasteners: Icopal BS-S-4.8mm Stainless Steel Fastener Tube Washer Type: Icopal R45 Membrane Tube Washer Icopal R75 Insulation Tube Washer Insulation Thickness (mm) Tube Washer Length (mm) BS-4.8mm Carbon Steel Fastener (mm) BS-S-4.8mm Stainless Steel Fastener (mm) 60 35 60 60 70 35 70 80 80 65 50 60 90 65 60 60 100 85 60 60 110 85 60 60 120 105 50 60 130 105 60 60 140 105 70 80 150 135 50 60 160 135 60 60 170 135 70 80 180 165 50 60 190 165 60 60 200 185 50 60 210 195 50 60 220 195 60 60 230 195 70 80 240 225 50 60 250 225 60 60 260 225 70 80 Insulation Thickness (mm) Tube Washer Length (mm) BS-4.8mm Carbon Steel Fastener (mm) BS-S-4.8mm Stainless Steel Fastener (mm) 60 35 70 80 70 35 80 80 80 65 60 60 90 65 70 80 100 85 60 60 110 85 70 80 120 105 60 60 130 105 70 80 140 105 80 80 150 135 60 60 160 135 70 80 170 135 80 80 180 165 60 60 190 165 70 80 200 185 60 60 210 195 60 60 220 195 70 80 230 195 80 80 240 225 60 60 250 225 70 80 260 225 80 80-11 -

Guidance Notes examples only Washer/Fastener Combinations Concrete Deck Application Structural Deck: Concrete Minimum deck embedment: 25 mm Suitable Fasteners: Icopal TI-T25 6.3 mm Carbon Steel Fastener - Pilot hole diameter to be determined by a pull out test. - Drill depth to be 10 25 mm greater than fastener embedment, to allow for swarf. Tube Washer Type: Icopal R45 Membrane Tube Washer Icopal R75 Insulation Tube Washer Insulation Thickness (mm) Tube Washer Icopal TI-T25 Carbon Steel Fastener (mm) 60 35 60 70 35 70 80 65 50 90 65 60 100 85 60 110 85 60 120 105 50 130 105 60 140 105 70 150 135 50 160 135 60 170 135 70 180 165 50 190 165 60 200 185 50 210 195 50 220 195 60 230 195 70 240 225 50 250 225 60 260 225 70 Note: Fastener length & Tube Washer combination has been calculated based on fixing direct to concrete slab without screed. - 12 -

Icopal Fasteners & Accessories A Range of Tubular Washers, Plates and Screw Fasteners Quality Assurance Icopal Tubular Washers, Pressure Plates and Screw Fasteners are supplied under a Quality Management System approved to ISO 9001: 2004 by Swiss Association for Quality and Management Systems. Insulation Attachment 16306 Icopal Thermazone PIR insulation boards should be attached at the minimum rate of 11 tubes & fasteners per 1.2 m x 2.4 m board (unless otherwise specified and approved). An increased density may be recommended depending on project location, height and exposure etc. Delivery and Storage Items are delivered in boxes. Keep the materials in unopened packaging prior to use, reseal any damaged packing. Technical Services Specialist advice and design guidance on all matters relating to Icopal Tubular Washers, Pressure Plates and Screw Fasteners is freely available from our Technical Department at the address below. Membrane Attachment For every mechanically fastened roof, a wind uplift calculation and fastener specification will be required prior to installation of the Icopal roof waterproofing membrane. All calculations are conducted in accordance with BS 6399 or BS EN 1991 parts 1-4, as appropriate. Fastener Application No pre-drilling is necessary for timber and steel decks. Simply insert the fastener through the tubular washer and install with a standard clutch drive electric screw gun (0 2500 rpm). Optimum fastener performance is achieved when fastener is installed perpendicular to the deck and into the top flutes of a steel deck. The TX-25 recess provides excellent drivability and the drill-point design cuts a hole in the steel deck maintaining contact between the deck and the minor diameter of the fastener, increasing back-out resistance. NOTE: This information is given in good faith being based on the latest knowledge known to. Whilst every effort has been made to ensure the contents of the publication are current while going to press, customers are advised that products, techniques and Codes of Practice are under constant review and liable to change without notice. Up to date information is available from our Technical Services Department on request. Responsibility cannot be accepted for the application of products, and no claims can be considered, where the manufacturer s instructions have not been followed. The user should not assume; based on information provided in this sheet, that the product is suitable for any abnormal use. All products are sold subject to our standard conditions of sale, available on request. - 13 -