DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Similar documents
DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

DKG 972. Gas Burner Safety Control. For 2-stage atmospheric gas burners

Gas Burner Safety Control DMG 970

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

Gas burner automatic safety control MMI / 811.1

SGU 930 SGU 930i. Control box

MMI (40-34) Gas burner safty control

MMG Gas burner safety control

LAE10 LFE10. Use. Series 02

Flame Safeguards LFE10. Building Technologies HVAC Products

EUROBOX SERIES TYPES CM... SM... MM...

Flame Safeguards LFE10. Building Technologies HVAC Products

EUROBOX SERIES TYPES CM...N SM...N MM...N

Forced draught gas burner

EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..

UV Flame Supervision System

Forced draught gas burner

LFL Series Burner Flame Safeguard Control

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

EUROFLAT SERIES TYPES C... S... M...

Use. The burner controls are certified to EN 230 and EN 298.

Burner controls. Building Technologies HVAC Products

Oil Burner Controls LMO24... LMO44...

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

Oil Burner Controls LMO24... LMO44...

Use. Burner controls for use with forced draught gas or gas / oil burners of small to medium capacity in intermittent operation.

Settings and Maintenance of the CombinAir

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

Operator: Save these instructions for future use!

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

UV - flame detector dual fuel burners for intermittent burner operations

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Quickheat 30 weather compensated boiler control

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Operator: Save these instructions for future use!

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

50A Integrated Furnace Control

MICROFLAT SERIES TYPES C.../U T X

C Note! LGI16... Burner Controls. Building Technologies

DOMESTIC HOT WATER Follow operational sequence

Gas Burner Controls. Building Technologies HVAC Products

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

Operator: Save these instructions for future use!

Old documentation - Only for your information! Product is not available anymore!

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

Oil Burner Controls LOA3... Building Technologies HVAC Products

Flame Safeguard Fault Code Diagnostics

CATALOGUE PRODUITS - CSA - CSI - CSM - CSS - CSS2 - P16 - P19 - P20 - P25 - UV DETECTOR

AUTOMATIC BURNER CONTROL SYSTEM SAFETY INFORMATION CONFORMITY

Operator: Save these instructions for future use!

Electronics. Burner control and flame detector for permanent and not-permanent operation ESA REFLAM-H (E7802 rev /04/2017)

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

7800 SERIES RM7888A Relay Module

Old documentation - Only for your information! Product is not available anymore!

User Manual 120/240/300 Outdoor Motion Detector

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

TWO STAGE HEAVY OIL BURNERS

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

Operator: Save these instructions for future use!

50A Integrated Furnace Control

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

7800 SERIES RM7888A Relay Module

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Burner Controls. Building Technologies HVAC Products

Program module for burner control LME71.000

Manual MPA 4112 PF. Edition: No GB. Printed in Germany Edition Nr

Gas-Gebläsebrenner Brûleur gaz à air soufflé Forced draught gas burner Gasventilatorbrander Quemador de gas de aire soplado

DATASHEET. Burner control unit FDA 601x

Burner control unit BCU 370

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

DIGITAL BURNER CONTROLLER DBC2000 SERIES

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers:

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

BC-R10 Series. Burner Controllers

7800 SERIES EC7885A/RM7885A Relay Module

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies HVAC Products

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules

Light oil burners. One stage operation

Part 3 Troubleshooting

BIX B-One 100 kw INSTALLATION GUIDE

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

Burner control unit BCU 370

Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs.

BGH Series Hot Surface Ignition Control

HT-2 / 9600 Series Control Contents

Model 60200FR Gas Primary Control Data Sheet

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Transcription:

A Honeywell Company Gas Burner Safety Control For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit Possible flame detectors: - Ionisation probe - Infrared flicker detector 1020 - UV flame sensor UVD 971 0737.13-01-e/08/00 INTRODUCTION The burner control box controls and supervises power burner for gas and dual fuel. The control box is currently under approval according the relevant European standards. The use on direct air heaters according DIN 4794 is also possible. With the facility to connect an air damper unit, a 2 stage operation with two fuel valves or a modulating operation with one fuel valve is possible. The microprocessor- based programming sequence ensures extremely stable timings independent of voltage variations, ambient temperature and/or switch-on cycles. The built-in information system not only provides a continuous monitoring of the actual state of the box (very helpful especially for monitoring the start-up phase) but also informs about the cause of a possible. The cause is stored in such a way that it can be retrieved even after a power failure. The control box is designed for maximum safety in case of fluctuations in the voltage supply. If the mains voltage drops below the permitted level, operation is interrupted and the control box automatically prevents the start sequence from being repeated. In this way, the safety of the system is not put at risk by a drop in the mains voltage. This low-voltage protection works not only during start-up but also permanently during operation. CONSTRUCTIONAL FEATURES Microprocessor, electronic components, output relais and flame amplifier are placed on two printed circuit boards. These plus the lockout- and reset circuit are well protected inside a flame resistant, plug-in type plastic housing. The reset switch for reset / remote lockout with its built-in LED for displaying the information system plus the central fixing screw are placed on top of the housing. The wiring base S98 is equipped with spare- and extraterminals and allows together with a variety of cable entry points utmost flexibility of electrical wiring. The is funstionally compatible to MMI 813 and MMI 813.1 Please note: Is the to be used to replace the MMI 813 or 813.1, care has to be taken to make sure the air proving switch (LW) is wired between terminals 4 and 7 and not like on the MMI between 5 and 7. TECHNICAL DATA Operating voltage 220 / 240 V (-15... +10%) 50 Hz ( ±5%) or 110 / 120 V (-15... +10%) 60 Hz ( ±5%) Fuse rating 10 A fast, 6 A slow Power consumption ca. 12 VA Max. load per output - term. 3 ignition trafo 1.5 A, cos ϕ 0.2 - term. 4 motor 2.0 A, cos ϕ 0.4 - term. 5 + 6 solenoid valves 1.0 A, cos ϕ 0.4 - term. C air damper 1.0 A, cos ϕ 0.4 - term. B alarm indicator 1.0 A, cos ϕ 0.4 total load 5.0 A, cos ϕ 0.4 max. 20 A during 0.5 sec Direct lockout after a loss-of-flame during operation Air proving switch 1 working contact 4 A, 230V Sensitivity (operation) 1 µa Min. required ion. current 1.5 µa Sensitivity for stray light 0.4µA Ionisation probe insulation Probe - earth greater than 50 MΩ stray capacity Probe - earth less than 1000 pf cable lenght < 3 m Flame detectors IRD 1020 side-on or end-on viewing UVD 971 end-on viewing Weight incl. Wiring base 190 g Mounting position any Protection class IP 40 Approved ambient parameter for control and flame detector max. 95% at 30 C - for operation -20 C... +60 C - for storage -20 C... +80 C Build-up of ice, penetration of water and condensing water are inadmissible Approvals according to European standards EN 298 and EN 230, as well as all other relevant Directives and standards Classified acc. to EN 298 FTLLXN Table of timings (sec.) Model max. reaction supervised pre-ignition LK-open command LK-close post-ignition Stray light safety delay time for air pre-purge time during pre-purge movement time monitoring time terminal 6/C proving switch time tlw tv1 tvz tkl tr tn tf ts tv2 01 60 44 3 36 8 2 5 3 6 1

APPLICATION FEATURES 1. Information system The information system is microprocessor based and reports on all aspects of burner control box operation and flame supervision. It informs continuously about the actual programming sequence the unit is just performing. Besides monitoring of the programming sequence it also allows to identify errors during start-up of operation without any additional testing devices. The automatically performed diagnosis is a valuable tool which facilitates service/ maintenance work and therefore saves costs. The analyses of the error cause can be done directly on stage or if not possible afterwards as the reason is stored in a nonvolatile mode memory. The information system communicates with the outside world using a LED (the used Flash-Code is similar to the Morse-Code). The messages are optically transmitted by a appropriately flashing LED. Using an additional terminal (optional), the messages can be recorded and displayed in easy readable form. 1.1 Programming sequence display The built-in microprocessor controls not only the programming sequence but the information system too. The individual phases of the programming sequence are displayed as Flash-Code. The following messages can be distinguished: Message Flash-Code waiting for. air proving switch pre-purge. tv1 pre-ignition. tvz safety time. ts delay 2nd stage. tv2 running. low mains voltage. Internal fuse defect. > control box defect Description = short pulse = long pulse. = short pause _ = long pause 1.2 Lock-out diagnoses In case of a failure the LED is permanently illuminated. Every 10 seconds the illumination is interrupted by a flash code, which indicates the cause of the error. Therefore the following sequence is performed which is repeated as long as the unit is not reset. Sequence: illuminated phase dark phase Flash-Code dark phase for 10 sec for 0.6 sec for 1.2 sec Error diagnosis Error message Flash-Code Possible fault within safety time safety time no flame establishment stray light stray light during monitored phase, detector may be faulty air proving switch air proving switch in closed position contact welded air proving switch air proving switch does not time-out close within specified time air proving switch air proving switch opens opened during start or operation loss of flame loss of flame during operation Flash-Code for manual anual/external (see also 3. and reset) 2. Flame detection The following types of flame detectors are suitable: Ionisation probe, temperature resistant material, well insulated (material and insulation same as for ignition electrode). Infrared-flicker detector type IRD 1020 with mounting flange M 93 or the UV solid state flame sensor UVD 971. Flame detection using an ionisation probe is only possible in conjunction with mains supplies which provides a neutral earth connection. Connecting the IRD 1020 or UVD 971 the correct wiring has to be observed. 2.1 Stray light monitoring The stray light check is performed at the end of the prepurge time for thr duration as mentioned in the table of timings. 2

3. Lock out and reset The unit can be reset or brought into mode in two different ways: Internal In the case the unit can be reset by pushing the builtin button meaning a new start-up cycle is performed. External Instead of using the built-in button the same function can be achieved by using an external button which connects terminal 9 with A (see also circuit and block diagram). If the pushputton (internal or external) is pressed during normal operation or during the start sequence for more then 3 sec. and afterwards released, the control box will perform a shutdown. Please note The unit can only be brought to lockout mode or be reseted if power is applied to the unit. 4. Low-voltage protection at 220 / 240V (110 / 120V) nominal voltage 7. Mounting and electrical wiring Wiring base: 3 earth terminals with additional terminal for burner earthing 3 neutral terminals with internal permanent connection to neutral terminal 8 2 independant spare terminals (S1 and S2) extra terminals A, B and C are standard 2 slide-in plates and 2 easy knock out holes (PG11 thread) plus 2 knock out holes in the base bottom faciliate the base wiring The digital controls are ideally wiried on the new wiring bases S98, which are equipped with (terminals B and C are only for some special types of DMO or DMG) terminal A,. which is used for the remote reset / remote lockout functions. Please note To assist trouble-free operation the main neutral connection terminal in the wiring base must be fully tightened. The terminal screws are already in the undone position. To connect a wire to the terminal, the screw only needs to be fastened. General: The control box and detector probes should not be subjected to excessive vibration. The mains voltage has to be more than 187 V eff (94 V eff ) in order to allow the unit to perform a start-up. The mains voltage is not only monitored in the start-up phase but also permanently during operation. If the voltage drops below < 160 V eff (80 V eff ) during start-up or run time the control box goes into mode. If the voltage rises again, the control box performs automatically a start-up as soon as the mains voltage is > 187 V eff (94 V eff ). 5. Safety The design and control sequence of the DMG 970 controls will comply with the currently applicable standards and regulations (see also TECHNICAL DATA). 6. Burner with an air damper motor The position of the air damper during pre-purge has to be assured by suitable actions (EN 676, 4.4.1.2). 3

INSTALLATION INSTRUCTIONS AND MAINTENANCE 1. Important notes The controls must be installed by qualified personnel only. The relevant national regulations have to be observed. On commissioning the wiring has to be carefully checked according the appropriate diagram, Incorrect wiring can damage the unit and endanger the installation. The fuse rating has to ensure that the limits specified in TECHNICAL DATA will not be exceeded. If these precautions are not observed, the effect of a short circuit can cause severe damage to the control and installation. For safety reasons a minimum of one control shutdown per 24 hours has to be observed. Disconnect the mains before the control box is plugged in or out. The control box is a safety device and must not be opened! 2. Function control For safety reasons the flame detection system should be tested on commissioning the installation as well as after a service or longer shut-down. a) Start-up with closed gas valve After safety time is over the unit has to go into mode! b) Normal start-up, when burner is running, close gas valve After loss of flame, the control box has to go into lockout mode c) Normal start-up, during pre-purge or operation, interrupt the air proving switch The control box has to perform a lockout immediatly d) Bridged air proving switch before start the fan motor switches on for approx. 2-3 secs, followed by a lockout. After 10 secs., this quick lockout is resetted by the control box and a second start attempt follows (fan motor switches on for approx. 2-3 secs.). A standard lockout appears if the air proving switch (LW) contact is still in it s closed position (e.g. welded contacts). Has the air proving switch (LW) changed to it s open position in the meantime (e.g. by a run down motor), a normal start sequence follows. 3. Fault finding The built-in information system facilitates the trouble shooting in the case of problems occurring during start-up or during operation. A list of possible messages can be found in APPLICATION FEATURES chapter 1.2. Please note: The control box is locked in mode and the reasen for the is displayed until the control box is reset, either by an internal or external reset (see also subject 3. Lock out and reset"). Removing the control box from its wiring base or by interrupting the supply line may not reset a. Therefore, by applying power, the fan motor switches on for 2-3 secs. before the control box goes to again and the cause of the last. Error Burner not working - No or too low flame signal (flame does not stick, bad insulation of the ionisation probe, bad connec- tion to frame ground) - Insufficient light on IRD - Sensitivity adjustment too low on IRD Fan motor starts for a short period of time, control box goes to Control box locks out during pre-purge Control box locks out at the end of pre-purge Burner starts, flame not established, Burner starts, flame established, after safety time, Possible fault - Thermostat circuit open - Faulty electrical wiring - mains voltage < 187 V (< 80 V) - Terminal A continuously on power (e.g. terminal A is used as a support terminal) - Control box has not been reset - Air proving switch not in open position - Air proving switch open - Air proving switch open - Flame signal - No ignition or no fuel 4

CIRCUIT AND TIMING DIAGRAM WITH AIR DAMPER MOTOR Ph N Ph max. 10A fast 6A low HS ST GW RT 1 2 3 4 5 6 C B 7 9 8 A IS Z M V1 L SA WITHOUT AIR DAMPER MOTOR max. 10A fast 6A low HS ST GW RT LW EV EV HS GW ST RT EV IS Z M V1 V2 LW SA L Mains switch Gas proving switch Limit thermostat Control thermostat External reset and button Ionisation probe (IRD 1010, UVD 970 see separate diagram) Ignition Burner motor Solenoid valve, 1st-stage Solenoid valve, 2nd-stage Air proving switch External signal Air damper motor tlw max. reaction time for air proving switch tv1 Supervised pre-purge time tlk LK-open command during pre-purge tr LK-close movement tf Stray light monitoring tvz Pre-ignition time tn Post-ignition time ts Safety time tv2 Delay terminal 6/C 1 2 3 4 5 6 C B 7 9 8 A LW IS Z M V1 V2 SA N tlw tv1 tlk tr tf tvz tn ts tv2 IRD- OR UVD CONNECTION IRD 1020 UVD 971 blue black brown term. 8 term. 2 term. 9 BLOCK DIAGRAM Oscillator EEPROM Fault display Information system µc Watchdog Reset and Reset µc Mains monitoring Flame amplifier Power supply monitoring RZ RV1 RV2 RLK RS Power supply rlk rv1 rz rs rv2 2 C 6 5 7 4 3 B 8 9 A 5

AND SOCKET HOLDER M 93 FOR IRD 14 35 3 4.5 26 VARIATION IRD 15.1 right 48 4 62,5 24 38,5 4,5 PG 11 86 60 Reset button 24 Slide-in plate 30 30 16 44 M4 Earth 25 35 30 57-60 Underside cable entry ø16 mm UVD 971 IRD 1020 29 29 50 21,8 21,8 ø13,5 UVD = 29 IRD = 44 UVD = 89 IRD = 104 axial 17 left ø20.5 ORDERING INFORMATION ITEM DESIGNATION ITEM NO. Control box Mod. 01 0353001 Socket Wiring base S98 12-pin 75310 Insert plate PG-Plate 70502 optional Cable entry plate 70501 Flame detector IRD 1020 end-on 16522 Flame detector IRD 1020 left 16523 Flame detector IRD 1020 right 16521 optional UVD 971 16722 Support for IRD Holder M93 for IRD 1020 59093 Support for UVD Holder M74 for UVD 59074 Connection cable Plug type, 3 core cable, 0.6 m with tag wire ends 7236001 The above ordering information refers to the standard version. Special versions are also included in our product range. Specifications subject to change without notice