TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Similar documents
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

EMERGENCY DRENCH SHOWER

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

Cooler Mounted Bottle Fillers

Model 9001, Alarm

Cooler Mounted Bottle Fillers

Model 9001, Alarm

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model Combination Shower Eye/Face Wash

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

Model /8300CRP-8309CRP Shower & Eye/Face Wash

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash

A112408B/S-VR-UBL TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Technical Assistance Fax:

Model /8320CRP Shower and Eye/Face Wash

INSTRUCTIONS FOR OPERATION AND CARE OF

INSTRUCTIONS FOR OPERATION AND CARE OF. P.O. Box 3527 City of Industry, CA, , U.S.A

Installation S19-324D1. Class I, Division 1, Groups C & D Explosion Proof. Emergency Signaling System

INSTRUCTIONS FOR OPERATION AND CARE OF

A152.8 Series Barrier Free, Bi-Level, Wall Mounted Drinking Fountain

Installation. S19-320A (6' cable) S19-320D (12' cable) Flow Switch Alarm System. Table of Contents

DISCONTINUED. Installation. S19-320A (6' cable) S19-320D (12' cable) Flow Switch Alarm System. Table of Contents

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL A171.8 Series Barrier Free, Wall Mounted Water Cooler

A132.8 Series Barrier Free, Wall Mounted Electric Drinking Fountain

Model 8356WCC Pull-Down Shower Eye/Face Wash

Model 8356WCSM Pull-Down Shower Eye/Face Wash

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

INSTRUCTIONS FOR OPERATION AND CARE OF

Comfort Series Instant Hot Water System

OPERATING MANUAL/ INSTALLATION

Installation Instructions / Warranty

Please Read and Save These Instructions.

Installation and Maintenance Instructions

Alnor AirGard 410HE Air Flow Monitor for Hazardous Environment Fume Hoods

RK / RK Methane Detector Operator s Manual

INSTALLATION INSTRUCTIONS

Model TWBS.EW.H Tempered Water Blending System

RK/ RK Oxygen Detector Operator s Manual

A172108F-UBL / A172408F-UBL / A172108F-SO / A172408F-SO TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

Installation and Operating Instructions

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

Installation, Operation & Service Manual

Installation Instructions

RK / RK CO 2 Detector Operator s Manual

RK/ RK Oxygen Detector Operator s Manual

Bathroom Exhaust Fan/Fluorescent Light Combination

Model 7500EB Portable Eyewash with Heater

Model 7656WCC Eye/face Wash

Installation Instructions / Warranty

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

MaxLite LED Vapor Tight Linear Fixture

PNLDII-28 Condensate Drain Instruction Manual

RK-03 Hydrogen Detector Operator s Manual

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

INSTRUCTIONS FOR OPERATION AND CARE OF

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

55-Gallon Dispenser Package

RK/ RK Carbon Monoxide Detector Operator s Manual

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

HUMIDITY SENSING BATH FAN

Arch Feeder: Installation Manual

BUNN H5E H5M H5X BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

Mixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50

Model H1011.8/H1011.8HPS Water Cooler

Models: FM FM WARNING

Installation Instructions PP-AS20 Anti-Scale System

Heater Installation Kit

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

SUNCOURT RADON FAN MODEL: RDN04 & RDN04-3, RDK04 & RDK04-3 INSTALLATION INSTRUCTIONS

Installation & Operation Manual

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

Static Pressure Alarm For Hazardous Location Fume Hoods

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

INSTANT HOT WATER RECIRCULATING SYSTEM

Zero Waste Retrofit Kit Instruction

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

TUB AND SHOWER FAUCET

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash/Portable Eyewash with Heater

Bathroom Exhaust Fan/Fluorescent Light Combination

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Model 405 AIRGARD Fume Hood Monitor

Installation Instructions

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

BIG BOOT COMBUSTION AIR KIT Model: CAS-2BB, CAS-2CB, CAS-2B375

Model EPWHP. How to install, operate and maintain your Water Heater Protector. Do not return unit to store

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

A171.8 Series Barrier Free, Wall Mounted Water Cooler

A2Z Ozone, Inc. PRODUCT MANUAL

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

INSTANT-FLOW C-MICRO WATER HEATER

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

Installation & Operation Manual for WarmlyYours Riviera Towel Warmers

SYSTEM CONTROL KIT READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Transcription:

ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 91744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS ELECTRIC ALARM WITH LIGHT AND HORN Models S0000-AL1 / S0000-AL2 and S0000-AL1-ASW / S00000-AL2-ASW TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER 1.800.591.9360 TECHNICAL ASSISTANCE FAX: 1.626.855.4894 NOTES TO THE INSTALLER: 1. Please leave this documentation with the owner of the fixture when finished. 2. Please read this entire booklet before beginning the installation. 3. Check your installation for compliance with plumbing, electrical, ANSI Z358.1 and other applicable codes. LIMITED WARRANTY UNITED STATES AND CANADA Acorn Safety warrants that its products are free from defects in material or workmanship under normal use and service for a period of one year from date of shipment. Acorn's liability under this warranty shall be discharged solely by replacement of repair of defective material, provided Acorn is notified in writing within one year from date of shipment, F.O.B. Industry, California. This warranty does not cover installation or labor charges and does not apply to materials, which have been damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Acorn under this warranty. Acorn shall not be liable under any circumstances for incidental, consequential or direct charges caused by defects in materials, or any delay in the repair or replacement thereof. This warranty is in lieu of all other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. Stainless steel must be protected on job sites during construction and must be properly maintained after the water has been introduced into the safety product or Acorn's warranty is void. Acorn Safety Division of Acorn Engineering Company, A member of Morris Group International

PRELIMINARY STEPS 1. Read the installation instructions prior to beginning the installation. 2. Separate parts from packaging and verify all necessary parts are accounted for and undamaged. Obtain missing or damaged parts from Acorn Safety prior to beginning installation. 3. Flush water supply lines prior to installation. This will remove unwanted debris from the lines and prevent unwanted blockages in the safety equipment. 4. In order to comply with ANSI Z358.1, the safety equipment must be inspected periodically. An inspection tag is provided for documentation purposes. 5. All employees at risk of contamination should be informed and trained in the use of this and any other safety equipment. The signage provided should be posted appropriately in close proximity to this equipment. ROUGH-IN S0000-AL1 / AL2 5" [127] 120VAC NEMA 4X AMBER NON-FLASHING LED LIGHT (AL1) OR FLASHING LED LIGHT (AL2) ADJUSTABLE NEMA 4X HORN WITH 1-1/4" PIPE FIXING CLAMP PROVIDED 19" [483] PIPE CLAMP PROVIDED POWER SUPPLY: 120VAC, 0.13 AMPS PROVIDED BY OTHERS UNIONS & PIPE SUPPLIED BY OTHERS FLOW 125 / 250VAC, 5A DPDT DOUBLE POLE DOUBLE THROW FLOW SWITCH 12" [305] 6" MIN [152] 6" MIN [152] 1-1/4" NPT FEMALE TEE (INCLUDED) 5 FT FLEXIBLE WEATHER PROOF POWER CONDUIT GENERAL NOTES: 1. ALL DIMENSIONS ARE IN INCHES [MM]. 2. FLOW SWITCH SHALL BE INSTALLED VERTICALLY WITH HORIZONTAL FLOW. 3. DIRECTION OF WATER FLOW MUST BE IN SAME DIRECTION AS SHOWN ON FLOW SWITCH. 4. HORN INCLUDES AN EXTERNAL ADJUSTMENT SCREW AND MAY BE ADJUSTED FROM 73 db TO 103 db AT 10 FEET. Acorn Safety Division of Acorn Engineering Company, A member of Morris Group International Page 2 of 9

ROUGH-IN S0000-AL1 / AL2-ASW 5" [127] 120VAC NEMA 4X AMBER NON-FLASHING LED LIGHT (AL1) OR FLASHING LED LIGHT (AL2) ADJUSTABLE NEMA 4X HORN WITH 1-1/4" PIPE FIXING CLAMP PROVIDED 19" [483] 23 7 8 " [584] -ASW NEMA TYPE 4X SILENCING SWITCH PIPE CLAMP PROVIDED POWER SUPPLY: 120VAC, 0.13 AMPS PROVIDED BY OTHERS UNIONS & PIPE SUPPLIED BY OTHERS FLOW 125 / 250VAC, 5A DPDT DOUBLE POLE DOUBLE THROW FLOW SWITCH 12" [305] 6" MIN [152] 6" MIN [152] 1-1/4" NPT FEMALE TEE (INCLUDED) 5 FT FLEXIBLE WEATHER PROOF POWER CONDUIT GENERAL NOTES: 1. ALL DIMENSIONS ARE IN INCHES [MM]. 2. FLOW SWITCH SHALL BE INSTALLED VERTICALLY WITH HORIZONTAL FLOW. 3. DIRECTION OF WATER FLOW MUST BE IN SAME DIRECTION AS SHOWN ON FLOW SWITCH. 4. HORN INCLUDES AN EXTERNAL ADJUSTMENT SCREW AND MAY BE ADJUSTED FROM 73 db TO 103 db AT 10 FEET. Acorn Safety Division of Acorn Engineering Company, A member of Morris Group International Page 3 of 9

ELECTRICAL WIRING S0000-AL1 / AL2 ALARM LIGHT AUDIBLE ALARM POWER CONNECTION WIRE AND CONNECTORS BY OTHERS NC NO BLUE FLOW SWITCH C NOTES: WIRE AND CONNECTORS BY OTHERS EXISTING WIRES Acorn Safety Division of Acorn Engineering Company, A member of Morris Group International Page 4 of 9

ELECTRICAL WIRING S0000-AL1 / AL2-ASW ALARM LIGHT AUDIBLE ALARM WIRE AND CONNECTORS BY OTHERS RED CONNECTION POWER CONNECTION RED NC SILENCING SWITCH NO BLUE FLOW SWITCH C NOTES: WIRE AND CONNECTORS BY OTHERS EXISTING WIRES FLOW SWITCH Acorn Safety Division of Acorn Engineering Company, A member of Morris Group International Page 5 of 9

INSTALLATION INSTRUCTION Supplies required: (not provided by Acorn) 1. 14 gauge UL building wire to make up connections from (flow switch & light/alarm) to electrical service. 2. Piping (1¼ NPT), unions or other connections to meet required minimum distances for flow switch. 3. Wall anchoring hardware and fasteners for bracket & signage mounting. 4. Pipe sealant or Teflon tape for sealing water connections. IMPORTANT: FLUSH WATER SUPPLY LINES PRIOR TO CONNECTION TO SAFETY EQUIPMENT. Notes: l Flow Switch must be installed with tee fitting in horizontal position, flow switch body in vertical position and at least 6 from closest fitting. l Flow Switch direction of flow is indicated on switch body. l Use hand tools and wrenches in a manner which will prevent marring finished surfaces. Strap wrenches or tools with plastic jaw linings are highly recommended. l Refer to fixture rough-in information for location of supply. l Fragments of Teflon tape or pipe sealant residue can interfere with the proper operation of this unit. Ensure pipe sealing methods do not cause contamination in the system. STEP ONE: FLOW SWITCH INSTALLATION 1. Determine location of flow switch in water supply line. The inlet and outlet ports of the flow switch must be a minimum of 6 from any tees or elbows in the water supply line. Refer to fixture installation and rough-in drawing. 2. Mount the flow switch in-line of fixture supply inlet. The switch body must be in the vertical position with the water pipe horizontal. The water flow must be in the direction of the arrow that is marked on the flow switch body. FLOW DIRECTION ARROW MOUNTING BRACKET 3 4 " NPTI INLET PORT CONNECTION 5 FEET x 3 4" WATERTIGHT FLEXIBLE POWER CONDUIT 1 1 4" NPT FEMALE TEE Acorn Safety Division of Acorn Engineering Company, A member of Morris Group International Page 6 of 9 Manual #7109-301-001 Revised: 04/16/14

STEP TWO: ELECTRICAL CONNECTIONS 1. Determine location for mounting alarm and light. Light should be positioned a minimum of 7 feet above the ground for best visibility. 2. Use pipe saddle mounting bracket provided to fix alarm to existing safety drench shower. Alternatively use bracket as a template to locate wall anchors and fix bracket with installer provided hardware. 3. Install flexible power cable to alarm and flow switch. Flexible conduit may be trimmed for desired length. 4. Connect unit to power leads in the conduit body as labeled. Connect the three leads inside. NOTE: DO NOT SEPARATE WIRES ALREADY CONNECTED STEP THREE: TEST 1. Apply power to alarm and light. Unit should not be operating if safety equipment is not activated. 2. Supply water to fixture and flush air from system. 3. Activate safety equipment. Alarm and Light should now be operating. 4. De-activate safety equipment. Alarm and light should now automatically de-activate. 2 1 4 " (57) 4 2 1 " (114) SQ S000-AL4 MOUNTING BRACKET 1 3 8 " (35) Ø 0.344 (8.7) 3 1 2 " (89) ASW SILENCING SWITCH ONLY 5. Test silencing switch. Push silencing button, while alarm is active; the sound should stop and the light should continue to flash. 6. To reset -ASW Silencing Switch: Pull button firmly, an audible pop should be heard and a yellow band should be visible near the and of the mushroom button. NOTE: If the yellow band is not visible, switch is not reset and the horn will not sound next time alarm is activated. TO RESET AFTER SILENCING ALARM, ASW PUSHBUTTON MUST BE PULLED FIRMLY TO THE FULLY EXTENDED POSITION. YELLOW BAND 1 5 8 " (41) WHEN FULLY EXTENDED, A VISIBLE YELLOW BAND WILL BE APPEAR ON THE PUSHBUTTON SHAFT. Acorn Safety Division of Acorn Engineering Company, A member of Morris Group International Page 7 of 9

PARTS LIST S0000-AL1 / AL2 ITEM # PART NUMBER DESCRIPTION 1 7103-202-000 AL1 AMBER LED LIGHT 7103-201-199 AL2 AMBER LED LIGHT, FLASHING 2 7103-208-000 CONDUIT NIPPLE 1/2" NPT X 1-1/8" LG 3 7103-206-000 3/4"-1/2" NPT REDUCING COUPLING 4 7103-207-199 AUDIBLE ALARM WITH ADDITIONAL 3/4" NPT 5 7103-209-000 CONDUIT NIPPLE 3/4" NPT X 3" LG 6 7103-203-000 CONDUIT JUNCTION BODY 3/4" NPT 7 7103-204-000 WATERTIGHT CONDUIT FITTING 8 7103-220-000 3/4" x 5 FEET WATERTIGHT FLEXIBLE CONDUIT 9 7103-104-000 FLOW SWITCH, SAFETY, 1-1/4" NPT DPDT 10 7103-205-199 1-1/4" x 3/4" NPT MECHANICAL PIPE SADDLE Acorn Safety Division of Acorn Engineering Company, A member of Morris Group International Page 8 of 9 Manual #7109-301-001 Revised: 04/16/14

PARTS LIST S0000-AL1 / AL2-ASW PART ITEM # DESCRIPTION NUMBER 1 7103-202-000 AL1 AMBER LED LIGHT 7103-201-199 AL2 AMBER LED LIGHT, FLASHING 2 7103-208-000 CONDUIT NIPPLE 1/2" NPT X 1-1/8" LG 3 7103-206-000 3/4"-1/2" NPT REDUCING COUPLING 4 7103-207-199 AUDIBLE ALARM WITH ADDITIONAL 3/4" NPT 5 7103-209-000 CONDUIT NIPPLE 3/4" NPT X 3" LG 6 7103-203-000 CONDUIT JUNCTION BODY 3/4" NPT 7 7103-204-000 WATERTIGHT CONDUIT FITTING 8 7103-220-000 3/4" x 5 FEET WATERTIGHT FLEXIBLE CONDUIT 9 7103-104-000 FLOW SWITCH ASSY, 1-1/4" NPT DPDT 10 7103-205-199 1-1/4" x 3/4" NPT MECHANICAL PIPE SADDLE 11 7103-229-000 1/2" ADAPTER ELECTRICAL FITTING 12 7103-231-000 NYLON WASHER 13 0308-001-000 1/2" NPS PLATED STEEL LOCKNUT 14 7103-221-199 ASW AUDIBLE ALARM SILENCING SWITCH Acorn Safety Division of Acorn Engineering Company, A member of Morris Group International Page 9 of 9