HVAC OUTDOOR AIR VENTILATION STANDARD. ASHRAE Standard ASHRAE Standard

Similar documents
City of Chanhassen. Site address. Ventilation Quantity (Determine quantity by using Table R or Equation R )

Ventilation, Makeup and Combustion Air Calculations Submittal Form New Dwellings

Site address. Ventilation Quantity (Determine quantity by using Table N or Equation 11-1) Continuous ventilation

4. OVERVIEW OF MECHANICAL SYSTEM

LIGHT COMMERCIAL Heat and Energy Recovery Ventilators

Purify your world Bring a breath of fresh air to your business with vänee light commercial ERV and HRV solutions the energy-efficient choice for

TECHNICAL REPORT 3 Mechanical Systems and Existing Conditions Northfield Mental Healthcare Center Northfield, Ohio

Ventilation Techniques. Topic 5 - Audio 53

PDH & Professional Training

Jim Aswegan Chief Engineer

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.

The best way to enhance indoor air quality

Problems Air and Water Distribution Systems

2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC

LEED for Homes V4 Provisional Alternative Compliance Paths for the Canadian market March, 2017

ASHRAE Standard 62 Ventilation Report Technical Assignment #1. Calvert Memorial Hospital Prince Frederick, MD

Bill McCullough. Director ERV Products. Dallas, TX

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

GARCIA GALUSKA DESOUSA Consulting Engineers

Dwelling Ventilation Strategies, Including ASHRAE 62.2 ASHRAE Ventilation for Acceptable Indoor Air Quality

LEED for Homes Points

Displacement Ventilation

Case Study: Furman University Charles H. Townes Center for Science. Michael K. Mantai, PE, CCP President System WorCx

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Joseph Lstiburek, Ph.D., P.Eng, ASHRAE Fellow. Building Science. Adventures In Building Science. presented by

IAQ: Re-tuning Commercial Buildings

TECHNICAL REPORT 3: Mechanical Systems and Existing Conditions. Michael Morder Mechanical Option Advisor: Dr. William Bahnfleth

Energy Recovery with Cooling and Heating

7. MECHANICAL SYSTEM DESIGN

Technical Information

The Ed Roberts Campus

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

Technical Report Three

Comfort and health-indoor air quality

Mechanical Ventilation : How much is enough? Can there be Too Much? Subrato Chandra Resnet Meeting 2/20/07

Demand Controlled Kitchen Ventilation (DCKV) [Strategy]

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Coil Unit with Enhanced Humidity Control

Ventilation for New Low-Rise Residential Buildings July 20, 2015

Madeira City Schools Madeira, Ohio. HVAC Assessment. December 2011 (Revised February 2012)

Mechanical Ventilation for Kansas Weatherization Programs

Technical Assignment 3

MultiFamily Ventilation Updates: ASHRAE 62.2, Best Practices and Practical Applications RESNET Conference Atlanta, GA

USEFUL RESOURCES: Applicability. Item o of section 150. Review-Definitions Section 101

DIGI-VAV APPLICATIONS

HVAC DISTRIBUTION and DELIVERY SYSTEMS

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

(2.1) Design Conditions...5 (2.2) Ventilation Requirements..5 (2.3) Heating and Cooling Loads...6

VENTING GAS APPLIANCES NFPA 54 CODE

Re: AHRI Comments on Proposed Addendum be to ASHRAE Standard 189.1

Building Codes, Ventilation Rates, and Certified Performance. Ventilation Track Comfortech 2007 St Louis, MO September 27, 2007

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

air handling units AT THE LEADING EDGE OF AIR FLOW

Technical Assignment 1

Raised Access Floor - (AE Breadth Area)

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

Indoor Environmental Quality

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

HLR 1000E Technical Specifications

Dehumidification: Energy Efficiency Comparisons

CHAPTER IV AIR DISTRIBUTION AND BALANCE

IAQ Building Education and Assessment Model (I-BEAM)

Technical Report Rouse Boulevard. The Navy Yard Philadelphia, PA 19112

IES Whole-Building Energy Model Baseline Energy Model Input/ Output Report. East Liberty Presbyterian Church East Liberty Presbyterian Church

Residential New Home Construction Checklist

11/2 ORT THREEE. Virtua Repla. acement Hospi. ital. Voorhees NJ. Justin Prior. Mechanical

Technical Assignment #2a. Atlanta, GA Green Building Mechanical

Clearing the Air: Ventilation. RESNET Building Performance Conference San Diego, CA February 17 th, 2015

Anticipating Depressurization Issues Due to Air Tightness and Ventilation Needs

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating

INDOOR AIR QUALITY ASSESSMENT. Department of Revenue Office 218 South Main Street Fall River, MA

Advances in Lighting Controls and the Impact of ASHRAE Requirements. Rich Rattray, LC OSRAM SYLVANIA

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

Please carefully read the below policy regarding Home Partners Standards before completing the renovation checklist!

Building Science Basics

Tenant Design Criteria Section t Technical Criteria Updated: October Chain Bridge Road, Suite 105 Tysons Corner, VA 22102

Chilled Beam and Radiant Cooling Basics. Salt Lake City, UT ASHRAE Chapter December 2013 Nick Searle

Theatre Classification and Air Particle Count Is that Surveillance?

Matt Cooper, PE, BEMP, HBDP, Group 14 Engineering Ken Urbanek, PE, HBDP MKK Consulting Engineers, Inc.

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

SPACE TYPE: JUDICIAL CHAMBER

Why ventilate? Dilute contaminants Control or aggravate humidity Comfort or lack of cooling Odors Provide oxygen

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

IT S ABOUT TIME FOR FRESH AIR.

EADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option

Ventilation Strategies in Weatherization

Table of Contents. List of Figures and Tables. Executive Summary: 3 ASHRAE Standard 62.1 Section 6 Analysis 7

************************************************************************************************************************

design brief This design brief provides an introduction into the design and application of DV. It addresses the following issues:

Passive House Northwest AIA CEU Provider. Aubrey Gewehr March 27, 2015

Christopher Kelly Technical Report Three

C.E.P., C.E.M, C.I.P.E.

2015 & 2012 International Mechanical Code Significant Changes and the PA Uniform Construction Code

Product Data. Features/Benefits. 33CS Carrier Comfort System Variable Volume and Temperature (VVT )

GreenPark. GreenJet Throw Performance

COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

SECTION PLUMBING/HVAC FINAL TESTING, ADJUSTING AND BALANCING

Transcription:

ASHRAE Standard 62.1-2013 BuildingsOne February 4, 2016 Landlord s HVAC system design capacity shall equal or exceed outdoor air ventilation requirements specified in ASHRAE Standard 62.1-2013 (prospect tenant lease draft clause). Is your building s HVAC system design and operating parameters in compliance with the most current version of ASHRAE Standard 62.1? ASHRAE Standard 62.1 is the industry accepted standard of compliance, for HVAC ventilation criteria, in commercial, institutional and high-rise residential buildings. ASHRAE 62.1 is considered The Ventilation Standard for Acceptable Indoor Air Quality and is the basis for ventilation codes including the International Mechanical Code (IMC). The American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), includes 50,000 members that provide expertise and establish standards in Heating, Ventilation and Air-Conditioning (HVAC) building systems, energy efficiency, indoor air quality, refrigeration, and sustainability. ASHRAE Standard 62.1-2013 Compliance with ASHRAE 62.1 is also a prerequisite for LEED-NC (New Construction) credits within the LEED EQ (Indoor Environmental Quality) category.

ASHRAE 62.1 - PURPOSE SCOPE Specify minimum ventilation rates, and other measures, intended to provide indoor air quality (IAQ) that is acceptable to human occupants and that minimizes adverse health effects Intended for regulatory application to new buildings and existing building renovations and additions Guide the improvement of indoor air quality (IAQ) in existing buildings Defines the requirements for ventilation, air cleaning design, commissioning, installation, and operations and maintenance (O & M) If a subject property was developed, prior to the establishment of certain ASHRAE 62.1 provisions, the building s ventilation capacity may be considered non-compliant, within the expectations of a current, or prospect, owner, lender or tenant. By example, the HVAC system, in a building built in 1985, could provide a maximum of 7 cubic feet per minute (CFM) per person outdoor air, while the current ASHRAE 62.1-2013 Standard requires 17 CFM per person outdoor air. Although the building owner, may contend the HVAC system design is grandfathered, under previous, less stringent ASHRAE 62.1 conditions, a prospect tenant may require compliance, up to the current ASHRAE 62.1-2013 standard, as a precondition of their leasing criteria. 2

ASHRAE 62.1-2013 Section 6 provides the minimum ventilation requirements for the dilution and reduction of indoor air contaminants. ASHRAE 62.1-2013 OUTDOOR AIR VENTILATION REQUIREMENTS OFFICE CATEGORY Calculated Rate (combine both) Default Values People - Outdoor Air Rate Area - Outdoor Air Rate Combined - Outdoor Air Rate 5 cfm / person.06 cfm / SF 17 cfm / person Default Occupant Density = 5 occupants per 1,000 SF ( avg. 1 per 200 SF) Outdoor Ventilation Rate - Default Value Method The Default Value Method is straightforward and the building owner-operator should use this method if they are unsure of the occupant density, distributed across the premises, served by the HVAC air handling system. The default occupant density, utilized in determining office space ventilation rates, is 5 occupants per 1,000 SF (1 occupant per 200 SF). An owner-operator, estimating the outdoor air requirement for 20,000 SF, could assume 100 occupants in order to derive the required outdoor air CFM / person. EXAMPLE: - Default Value Method Category Value Rate Required Outdoor Ventilation Office SF 20,000 SF 17 CFM per occupant 1,700 CFM Outdoor air rate assumes 1 occupant per 200 SF. 20,000 SF / 200 SF per occupant = 100 occupants. 100 occupants x 17 CFM outdoor air per occupant = 1,700 CFM outdoor air provided to the premises. The illustration above determined the outdoor air requirement based upon the office premises occupancy (or size - SF). The table on the next page illustrates the technique of estimating outdoor air CFM conveyed by a representative HVAC Air Handling Unit (AHU). 3

Representative Air Handling Unit (AHU) - (CFM) Calculations Air Handling Unit (AHU) Rated Capacity (CFM) Total Area (Premises SF) Served by the AHU 20,000 38,000 Total Occupancy 190 Total Ventilation Rate CFM per Person 105 At 100% Speed. This figure will be reduced if the AHU is controlled by a Variable Speed Drive and operating at a reduced speed Entire SF area served by the AHU, in order to allocate CFM, as distributed, across the entire premises Default Estimated Occupancy is 1 person per 200 SF 38,000 SF / 200 SF per occupant = 190 occupants This represents the total air CFM provided by the AHU (outdoor fresh air and return air). 20,000 CFM / 190 occupants The estimated ventilation rate figures below are based on a typical HVAC system having exhaust air dampers. (the capacity to exhaust 100% of the supply air provided to the premises - full economizer ) CFM per person @ 100% outside air CFM per person @ 75% outside air CFM per person @ 50% outside air CFM per person @ 25% outside air 105 79 53 26 100% Outdoor Air Operation Return (mixed-air) dampers in closed position 75% Outdoor Air Operation 105 x.75 =.79 CFM Return (mixed-air) dampers 25% open position 50% Outdoor Air Operation 105 x.5 = 53 CFM Return (mixed-air) dampers 50% open position 25% Outdoor Air Operation 105 x.25 = 26 CFM Return (mixed-air) dampers 75% open position ASHRAE 62.1-2013 Required 17 CFM per person 17 Outdoor Air, as a percentage of Total Air, required in order to provide the minimum standard 17 CFM per person: 17 CFM / 105 CFM = 16%. Return (mixed air) dampers 84% open 4

Air Change Calculation Standard Measurement - Air Changes per Hour (ACH) The rate at which air is exchanged (in the premises) represents another method of measuring ventilation capacity & effectiveness. Air exchange rate is typically expressed in Air Changes per Hour - ACH. Air changes per hour can be estimated by determining the total air supplied to, and removed from, the premises total air exchange or the outdoor (fresh) air supplied to, and removed from, the premises outdoor air exchange. Air Change Calculation Standard Measurement - Air Changes Per Hour (ACH) Category Premises Size ALL AREAS served by the Air Handling Unit (AHU) Ceiling Height Premises Cubic Feet = Premises SF x Ceiling Height Air Handling Unit (AHU) Ventilation Rate (CFM) Ventilation Rate (CFH) (cubic feet per hour) CFM x 60 Air Changes Per Hour 168,000 / 180,000 Office 20,000 SF 9 0 180,000 Cu Ft 2,800 CFM 168,000.93 Air Changes Per Hour (.93 ACH ) 20,000 x 9 = 180,000 Cu Ft. 2,800 CFM x 60 minutes = 168,000 CFH. 168,000 CFH / 180,000 Cu Ft =.93 ACH 5