SERVICE MANUAL. Commercial Air Conditioning. MULTI upgrade series

Similar documents
THE INTELLIGENT CHOICE IN COMFORT SINGLE & MULTI TYPE AIR CONDITIONERS

Do you want a versatile solution to make significant savings? AIR-TO-WATER HEAT PUMP

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

4-WAY BLOW CEILING MOUNTED CASSETTE Daikin air conditioners for shops, restaurants and offices

Daikin air conditioners for small rooms in multi application

Daikin air conditioners for small rooms in multi application

Daikin air conditioners for shops, restaurants and offices

SINGLE ZONE WALL MOUNTED ART COOL PREMIER ENGINEERING MANUAL

Daikin air conditioners for shops, restaurants and offices

WCA3**4. Product Specifications

Midea. Products Catalogue. Midea Electric Trading (Singapore) co. Pte Ltd 158 Cecil Street, #07-01/02 Singapore Web Site:

SERVICE MANUAL. Commercial Air Conditioning. Models AU282FHAIA AU52NFIAKA AU60NFIAKA. And its indoor units. Features

AIR COOLED PACKAGED AIR CONDITIONERS

Samsung Air Conditioners

SPLIT-TYPE AIR CONDITIONERS R410A. New PUMY. S series. up to 8* indoor units. ?P100: up to 6 indoor units PUMY-P100YHM PUMY-P125YHM PUMY-P140YHM

2 &3-4 Head Multi System

PRELIMINARY. w w w. d a i k i n e u r o p e. c o m FDQ-B

Daikin Air Conditioning. Daikin air conditioners for shops, restaurants and offices. CEILING SUSPENDED UNIT. UK Price List Attached

DUAL TECHNOLOGY OCCUPANCY/VACANCY SENSOR SWITCH (WS XX DT XX/WS OS DTDR XX)

Daikin air conditioners for shops, restaurants and offices

Precision Air Conditioners

Atlas and Helios Unit Heaters Janus 05 Air Conditioners AIX Stainless Steel Unit Heaters Atlas STP Door Curtains Jetstream Induction Flow Optimizers

Product overview 2-3. Technology of Inverter 4-5. Inverter Wall Mounted 6-7. Inverter Ceiling Cassette E Series 8-9

BENSON AMBIRAD. ... Variante Gas Fired Unit Heaters ... HEATI NG AND VENTILATION S OLUTIONS

Daikin air conditioners for shops, restaurants and offices

TODAY, AIR CONDITIONING UNMISTAKABLY FORMS PART OF THE HOSPITALITY PACKAGE THAT YOU WANT TO OFFER YOUR

Reventon Group [Ltd.] 3B Montażowa Street, Bielsko-Biała, Poland VAT ID tel.

HEATINGSERIES POWERFUL SELECTION ZUBADAN SERIES MSZ-FD VABH SERIES

PLA-ZRP35/50/60/71/100/125/140BA PLA-RP35/50/60/71/100/125/140BA

improve your life Today ARGO is a technological and reliable brand, but also a young, dynamic and friendly brand.

Inverter Ducted Air Conditioners

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

digital remote control WARRANTY 10 years for excanger

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

Warning. Specifications, designs and other content appearing in this brochure are current as of May 2013 but subject to change without notice.

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL

JUNE & 3-4 Head Multi System

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

MHI Centrifugal Chiller

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

SPLIT. 9 types 64 models. Energy saving design to provide a comfortable indoor environment while being environment-friendly. 052 All Type Lineup

PCSAU1439A. Inverter series

Product Line Introduction. Karl Zhang Technical support engineer

Technical Manual. Multi Split Trio Quattro DCI REFRIGERANT R410A HEAT PUMP

Eagle PIR-018 / PIR-045 / PIR-100 Outdoor Passive Infrared Detectors

SERVICE MANUAL. Model

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

Ductless Split Systems Concealed Duct Heat Pumps

MULTI SPLIT. Control several indoor units with one outdoor unit. Build the optimum system you desire.

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

SPLIT. 9 types 65 models. Energy saving design to provide a comfortable indoor environment while being environmentfriendly.

From Japan to the World

Product Brochure Smart Power. Low Profile Ducted

A tool for professionals.

TECHNICAL DATA & SERVICE MANUAL

PCSHK1549. Cooling only -50Hz- Heat pump -50Hz-

Ultimate VRF System R410A, 50Hz

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Engineering Data Manual

DESIGN & TECHNICAL MANUAL

360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle

Heat Pump Air Conditioning Systems

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

AIR-CONDITIONER SERVICE MANUAL

Technical Description

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

ABBREVIATION LIST FAN SCHEDULE SERVED (IN) POWER (SONES) HP W VOLT PHASE VFD MFG EC N/A (LBS) SPLIT SYSTEM HEAT PUMP (OUTDOOR UNIT) SCHEDULE

Just feel well. 2017/2018 Air conditioning

Residential and Light Commercial Ductless Systems Catalog

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

Samsung Free Joint Multi Air Conditioning System

Technical Description

Technical Description

Air Conditioner SVC MANUAL(Exploded View)

World s best airconditioning

360 airflow!! PCSSG0814. AIR CONDITIONING SYSTEM [50Hz]

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

TECHNICAL & SERVICE MANUAL

Comfort. COMFORT Sabiana circular unit heaters, for ceiling installation only,

Hi - Wall Split Systems 12K - 18K - 24K

Engineering Data Book

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

TEST REPORT #68. Chiao M. Lee Paul Laurentius. Hussmann Corporation St. Charles Rock Road Bridgeton, MO United States of America

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

Inverter Ducted Air Conditioners

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

Engineering Data Book

Engineering Data Book

Transcription:

Coercial Air Conditioning SERVICE MANUAL MULTI upgrade series Models Indoor: AB09CS1ERA AB12CS1ERA AB18CS1ERA AB24ES1ERA AC12CS1ERA AC18CS1ERA AC24CS1ERA AD09LS1ERA AD12LS1ERA AD18LS1ERA AD24LS1ERA Outdoor: 3U19FS1ERA 4U25HS1ERA 4U30HS1ERA 5U34HS1ERA DC inverter technology, high energy efficiency, higher EER A+, energy saving for the user Universal indoor units for ulti upgrade series, Unitary sart DC inverter and HAIER DAC split inverter type High voltage counication, convenient wiring work Multiple control types 10 constant teperature control Universal power supply for 50Hz and 60Hz Central control function available New friendly refrigerant R410a, zero ODP, environent protection Manual code: SYJS-017-10REV.0 Edition: 2010-12-10

CONTENTS Contents...2 1. Description of products & features.3 2. Specification...6 3. Diensions...21 4. Pipe and wiring installation.....26 5. PCB photo, wiring diagra and function description..72 6. Diagnostic code and troubleshooting....95 7. Outdoor perforance curves.....101 8. Indoor air velocity and teperature distribution curves...105 9. Air flow and static pressure chart...111 10. Noise level...113 11. Sensor characteristic....121 12. Controller functions......124-2-

1.Description of products & features 1.1. Products code explanation 3 U 19 F S 1 E R A Cliate type: T1 (see table 1) Frequency type: DC inverter Product type: A stands for heat pup type, refrigerant is R22 B stands for heat pup type, refrigerant is R407C E stands for heat pup type, refrigerant is R410A N stands for cool only type, refrigerant is R407C Design edition Product series: S stands for EASY STOCK Product appearance Cooling / Heating capacity,19=19000btu/h Product type : B stands for cassette type, C stands for convertible type, D stands for duct, S stands for wall ounted type, "F" stands for console type, U stands for outdoor of split unit Max. 1 to 3 1.2 Brief Introduction for T1,T2,T3 working condition Cliate type Type of Air Conditioner T1 T2 T3 Cooling Only 18 ~43 10 ~35 21 ~52 Heat pup -7 ~43-7 ~35-7 ~52 Electricity Heating ~43 ~35 ~52 1.3 Operating Range of Air Conditioners Working teperature range Rated Maxiu Miniu Cooling Indoor DB 27 32 18 WB 19 23 14 outdoor DB 35 43-10 WB 24 26 6 Heating Indoor DB 20 27 15 WB 14.5 -- -- outdoor DB 7 24-15 WB 6 18 -- -3-

Coercial Air Conditioner 1.4 Product features DC inverter technology, high energy efficiency, higher EER A+, energy saving for the user The outdoor unit adopts DC inverter copressor and otor, so save power energy is just to save oney for the user. And the outdoor can atch with ultiple indoor units, up to 5 sets. Even when you have already installed the air conditioner, if you want to add or reduce one unit, go ahead freely as long as your operation coplies with our design. Greatly convenient for designer and installer. Precise control, ore cofortable and ore reliable The outdoor is equipped with electronic expansion valve, which will control refrigerant flow ore precisely. As a result, the user will feel ore cofortable and the unit is ore reliable. Also, the outdoor is with oil segregator, which will keep the copressor working norally and ake oil return ore soothly. Universal indoor units for ulti upgrade series, unitary sart DC inverter and HAIER DAC split inverter type The indoor units are universal for the outdoors which belongs to EASY STOCK series. EASY STOCK is new concept brought by Haier to be convenient for design, sale, operation, and stock anageent. Adopt the uch friendlier refrigerant R410a The air conditioner syste adopts the greatly friendly refrigerant R410a, which is protective for the ozone layer and is good to avoid the earth getting warer. Benefit for the environent. High voltage counication, convenient wiring work Connect indoor and outdoor directly, and there is no counication wire between indoors. Thus the wiring work is ore convenient. No need to set indoor address. Multiple control types The indoor unit can be controlled by ultiple types: infrared controller, wired controller, central controller. More choice, ore conveniently. 10 constant teperature control When leave hoe teporarily, press 10 button of reote controller, the indoor teperature won t decrease rapidly while be controlled at 10. When coe back hoe, press it again, the unit will be back to noral status and setting teperature. Auto restart function (optional) All indoor units have auto-restart function. When the power supply cut off suddenly, the unit will autoatically recover the previous running ode once the power supply is on. Self-diagnostic function In the course of operation, if the failure occurs, the failure code will display on the wired controller or -4-

Coercial Air Conditioner on the operation panel. Then according to the failure code chart, you can eliinate the failure soon. Central control function, if connected with a central controller That is convenient for building anageent. Weekly tiing function, if connected with a weekly tier Universal power supply for 50Hz and 60Hz The ulti upgrade series adopts universal power supply for 50Hz and 60Hz, which is convenient for design. Much wider application. 1.5 Product lineup Outdoor unit 220V/1/ (50/60Hz) Connection diagra Picture Max.indoor quantity 19 Cooling capacity(kbtu) 25 30 34 3 4 5 Indoor unit 220V/1/ (50/60Hz) kbtu/h 7 9 12 18 24 SERIES kw 2.2 2.8 3.6 5.0 6.5 Cassette Type(4-way) Floor & Ceiling type ceiling concealed duct HEM ounted type Console type -5-

2. Specifications -6- Ite Model 3U19FS1ERA Function Cooling Heating Rating capacity W 5400 6500 Power input (indoor + outdoor) W 1410 1520 Current input (indoor + outdoor) A 6.13 6.6 EER / COP W/W 3.84 4.28 Miniu capacity W 1500 1800 Miniu power input W 500 500 Maxiu capacity W 7000 8100 Maxiu power input (indoor + outdoor) W 2600 2600 Power source 1PH, 220-230V~, 50/60Hz Max.Running current (indoor + outdoor) A / A 11.3 11.3 Power facor(under rating power input) 99% 99% Fuse size (recoended size) A 16 Indoor units nuber 1~3 Model / Manufacture SNB130FGYMC-L1 / MGC Copressor Oil charge and type 500CC, FV 50S Type Twin Rotary (DC inverter) Winding resistance(at 20 ) Ω 0.58 Fan type Nuber Motor speed r/in Axial 1 Max. 860 Fan syste Fan otor odel ARW4403AS Motor type DC Motor output/input power W 55/69 Air-flows (H/M/L) ³/h about 2000 Type / Diaeter TP2M / 7.94 Heat Nuber of rows 2 exchanger Face area ² about 0.52 Diension External 886/289/688 (WxDxH) Package 990/405/760 Refrigerant control ethod Defrosting ethod PMVs Autoatic by reversible cycle Crankcase heater power W 35 Noise level H/M/L db(a) 52/-/- Weight Net / Shipping kg / kg 51/ 53 Refrigerant Type / Charge Total liquid piping length without recharge kg R410A /1.9 less than 30 Recharge g/ 20 Pipe size Liquid 3* Φ6.35 Gas 3* Φ9.52 Connecting ethod Flared Max.Drop between IU & OU 15 Between Max.Drop between indoor units 7.5 IU & OU Max.Piping length between IU & OU 25 Max.Total length 50 1. The above perforance data are fro the cobination of 3U19FS1ERA+3*AS09CS1ERA 2. Large drop and long piping installation will obviously reduce the total capacity. Norinal condition: indoor teperature (cooling): 27 DB/19 WB, indoor teperature (heating): 20 DB Outdoor teperature(cooling): 35 DB/24 WB, outdoor teperature(heating): 7 DB/6 WB The noise level will be easured in the third octave band liited values, using a Real Tie Analyser calibrated sound intensity eter. It is a sound pressure noise level. Outdoor unit Piping

Ite Model 4U25HS1ERA Function Cooling Heating Rating capacity W 7600 8600 Power input (indoor + outdoor) W 2100 2060 Current input (indoor + outdoor) A 9.1 9.0 EER / COP W/W 3.62 4.18 Miniu capacity W 1500 1800 Miniu power input W 550 550 Maxiu capacity W 9000 9500 Maxiu power input (indoor + outdoor) W 3500 3500 Power source 1PH, 220-230V~, 50/60Hz Max.Running current (indoor + outdoor) A / A 15.2 15.2 Power facor(under rating power input) 99% 99% Fuse size (recoended size) A 25 Indoor units nuber 2~4 Model / Manufacture TNB220FLHMC-L / MGC Copressor Oil charge and type 870CC / FV50S Type Twin Rotary (DC inverter) Winding resistance(at 20 ) Ω 0.88 Fan type Nuber Motor speed r/in Axial 1 Max. 860 Fan syste Fan otor odel EHDS80A100AS Motor type DC Motor output/input power W 100/125 Air-flows (H/M/L) ³/h about 4000 Type / Diaeter TP2M / 7.94 Heat Nuber of rows 2 exchanger Face area ² about 0.75 Diension External 948/340/840 (WxDxH) Package 1040/430/1000 Refrigerant control ethod PMVs Defrosting ethod Autoatic by reversible cycle Crankcase heater power W 35 Noise level H/M/L db(a) 56 Weight Net / Shipping kg / kg 74/85 Refrigerant Type / Charge Total liquid piping length without recharge kg R410A / 2.9 less than 40 Recharge g/ 20 Pipe size Liquid 4* Φ6.35 Gas 3* Φ9.52(A,B,C)+1*Φ12.7(D) Connecting ethod Flared Max.Drop between IU & OU 15 Between Max.Drop between indoor units 7.5 IU & OU Max.Piping length between IU & OU 25 Max.Total length 70 1. The above perforance data are fro the cobination of 4U25HS1ERA+4*AS09CS1ERA. 2. Large drop and long piping installation will obviously reduce the total capacity. Norinal condition: indoor teperature (cooling): 27 DB/19 WB, indoor teperature (heating): 20 DB Outdoor teperature(cooling): 35 DB/24 WB, outdoor teperature(heating): 7 DB/6 WB The noise level will be easured in the third octave band liited values, using a Real Tie Analyser calibrated sound intensity eter. It is a sound pressure noise level. Outdoor unit Piping -7-

Ite Model 4U30HS1ERA Function Cooling Heating Rating capacity W 8100 9800 Power input (indoor + outdoor) W 2220 2430 Current input (indoor + outdoor) A 9.7 10.6 EER / COP W/W 3.65 4.03 Miniu capacity W 1500 1800 Miniu power input W 550 550 Maxiu capacity W 9800 10500 Maxiu power input (indoor + outdoor) W 3800 3800 Power source 1PH, 220-230V~, 50/60Hz Max.Running current (indoor + outdoor) A / A 16.5 16.5 Power facor(under rating power input) 99% 99% Fuse size (recoended size) A 25 Indoor units nuber 2~4 Model / Manufacture TNB220FLHMC-L / MGC Copressor Oil charge and type 870CC / FV50S Type Twin Rotary (DC inverter) Winding resistance(at 20 ) Ω 0.88 Fan type Nuber Motor speed r/in Axial 1 Max. 860 Fan syste Fan otor odel EHDS80A100AS Motor type DC Motor output/input power W 100/125 Air-flows (H/M/L) ³/h about 4000 Type / Diaeter TP2M / 7.0 Heat Nuber of rows 3 exchanger Face area ² about 0.75 Diension External 948/340/840 (WxDxH) Package 1040/430/1000 Refrigerant control ethod PMVs Defrosting ethod Autoatic by reversible cycle Crankcase heater power W 35 Noise level H/M/L db(a) 58 Weight Net / Shipping kg / kg 76/87 Refrigerant Type / Charge Total liquid piping length without recharge kg R410A / 3.0 less than 40 Recharge g/ 20 Pipe size Liquid 4* Φ6.35 Gas 3* Φ9.52(A,B,C)+1*Φ12.7(D) Connecting ethod Flared Max.Drop between IU & OU 15 Between Max.Drop between indoor units 7.5 IU & OU Max.Piping length between IU & OU 25 Max.Total length 70 1. The above perforance data are fro the cobination of 4U30HS1ERA+4*AS09CS1ERA. 2. Large drop and long piping installation will obviously reduce the total capacity. Norinal condition: indoor teperature (cooling): 27 DB/19 WB, indoor teperature (heating): 20 DB Outdoor teperature(cooling): 35 DB/24 WB, outdoor teperature(heating): 7 DB/6 WB The noise level will be easured in the third octave band liited values, using a Real Tie Analyser calibrated sound intensity eter. It is a sound pressure noise level. Outdoor unit Piping -8-

Ite Model 5U34HS1ERA Function Cooling Heating Rating capacity W 10000 10700 Power input (indoor + outdoor) W 2940 2850 Current input (indoor + outdoor) A 12.8 12.4 EER / COP W/W 3.4 3.75 Miniu capacity W 1500 1800 Miniu power input W 550 550 Maxiu capacity W 11000 11500 Maxiu power input (indoor + outdoor) W 4000 4000 Power source 1PH, 220-230V~, 50/60Hz Max.Running current (indoor + outdoor) A / A 17.4 17.4 Power facor(under rating power input) 99% 99% Fuse size (recoended size) A 30 Indoor units nuber 2~5 Model / Manufacture -9- Copressor Oil charge and type Type Winding resistance(at 20 ) Ω 0.88 Fan type Nuber Axial 1 Motor speed r/in Max. 900 Fan syste Fan otor odel EHDS80A100AS Motor type DC Motor output/input power W 100/125 Air-flows (H/M/L) ³/h about 4000 Type / Diaeter TP2M / 7.0 Heat Nuber of rows 3 exchanger Face area ² about 0.75 Diension External 948/340/840 (WxDxH) Package 1040/430/1000 Refrigerant control ethod PMVs Defrosting ethod Autoatic by reversible cycle Crankcase heater power W 35 Noise level H/M/L db(a) 58/-/- Weight Net / Shipping kg / kg 77/88 Refrigerant Type / Charge Total liquid piping length without recharge kg R410A / 3.2 less than 40 Recharge g/ 20 Pipe size Liquid 5* Φ6.35 Gas 4* Φ9.52(A,B,C,D)+1*Φ12.7(E) Connecting ethod Flared Max.Drop between IU & OU 15 Between Max.Drop between indoor units 7.5 IU & OU Max.Piping length between IU & OU 25 Max.Total length 80 1. The above perforance data are fro the cobination of 5U34HS1ERA+3*AS09CS1ERA+1*AS18CS1ERA. 2. Large drop and long piping installation will obviously reduce the total capacity. Outdoor unit Piping TNB220FLHMC-L / MGC 870CC / FV50S Twin Rotary (DC inverter) Norinal condition: indoor teperature (cooling): 27 DB/19 WB, indoor teperature (heating): 20 DB Outdoor teperature(cooling): 35 DB/24 WB, outdoor teperature(heating): 7 DB/6 WB The noise level will be easured in the third octave band liited values, using a Real Tie Analyser calibrated sound intensity eter. It is a sound pressure noise level.

Ite Model AB09CS1ERA Function cooling heating Capacity kw 2.6 2.9 Sensible heat ratio 0.71 / Dehuidifying capacity 10 ³ ³/h 1.5 Power Supply 1PH,220-230V 50-60HZ Type Nuber CENTRIFUGALX1 Fan Speed(H-M-L) r/in 690/620/560 Fan otor output power kw 0.03 Air-flow(H-M-L) ³/h 620/520/450 Heat exchanger Type / Diaeter Total Area Tep. scope ² inner grooved pipe/φ7 0.272 2-7 Diension External (L W H) 570 570 260 Package (L W H) 718 680 380 Drainage pipe (aterial, I.D./O.D.) PVC 26/32 Control type (Reote /wired) Reote or Wired Fresh air hole diension Electricity Heater kw 56 NONE Noise level (H-M-L) db(a) 40/36/32 Weight (Net / Shipping) kg / kg 17/20 Panel odel (color) PB-700IB(WHITE) Diension External (L W H) 700 700 60 Package (L W H) 740 750 115 Weight (Net / Shipping) kg / kg 2.8 / 4.8 Refrigerant Type R410A Pipe Liquid φ6.35(1/4) Gas φ9.52(3/8) Connecting Method flared Norinal condition: indoor teperature (cooling): 27 DB/19 WB, indoor teperature (heating): 20 DB Outdoor teperature(cooling): 35 DB/24 WB, outdoor teperature(heating): 7 DB/6 WB The noise level will be easured in the third octave band liited values, using a Real Tie Analyser calibrated sound intensity eter. It is a sound pressure noise level. Indoor unit Panel PIPING -10-

Ite Model AD09LS1ERA Function cooling heating Capacity kw 2.6 2.9 Sensible heat ratio 0.71 / Dehuidifying capacity Power Supply 10 ³ ³/h 1.6 1PH,220-230V 50-60HZ Type Nuber CENTRIFUGALX1 Fan Speed(H-M-L) r/in 1000/900/800±50 Fan otor output power kw 0.05 Air-flow(H-M-L) ³/h 550/450/400 Static pressure Pa 25 Heat exchanger Type / Diaeter Total Area Tep. scope ² inner grooved pipe/φ7 0.11 2-7 Diension External (L W H) 610 483 220 Package (L W H) 695 536 265 Drainage pipe (aterial, I.D./O.D.) 20/24 Control type (Reote / Wired) wired Fresh air hole diension Electricity Heater kw NONE NONE Noise level Weight (H-M-L) (Net / Shipping) db(a) kg / kg 37/34/31 14/16 Refrigerant Type R410A Pipe Liquid φ6.35(1/4) Gas φ9.52(3/8) Connecting Method flared Norinal condition: indoor teperature (cooling): 27 DB/19 WB, indoor teperature (heating): 20 DB Outdoor teperature(cooling): 35 DB/24 WB, outdoor teperature(heating): 7 DB/6 WB The noise level will be easured in the third octave band liited values, using a Real Tie Analyser calibrated sound intensity eter. It is a sound pressure noise level. Indoor unit PIPING -11-

Ite Model AB12CS1ERA Function cooling heating Capacity kw 3.5(0.9--4.5) 3.7(1.0---4.8) Sensible heat ratio 0.71 Dehuidifying capacity 10 ³ ³/h 1.5 Power Supply 1PH,220-230V 50-60HZ Type Nuber CENTRIFUGALX1 Fan Speed(H-M-L) r/in 690/620/560 Fan otor output power kw 0.03 Heat exchanger Air-flow(H-M-L) Type / Diaeter Total Area Tep. scope ³/h ² 620/520/450 inner grooved pipe/φ7 0.272 2-7 Diension External (L W H) 570 570 260 Package (L W H) 718 680 380 Drainage pipe (aterial, I.D./O.D.) PVC 26/32 Control type (Reote /wired) Reote, YR-HD Fresh air hole diension Electricity Heater kw 56 NONE Noise level Weight (H-M-L) (Net / Shipping) db(a) kg / kg 40/36/32 18.5/23 Panel odel (color) PB-700IB(WHITE) Diension External (L W H) 700 700 60 Package (L W H) 740 750 115 Weight (Net / Shipping) kg / kg 3.5/4.5 Refrigerant Type R410A Pipe Liquid φ6.35(1/4) Gas φ9.52(3/8) Connecting Method flared Norinal condition: indoor teperature (cooling): 27 DB/19 WB, indoor teperature (heating): 20 DB Outdoor teperature(cooling): 35 DB/24 WB, outdoor teperature(heating): 7 DB/6 WB The noise level will be easured in the third octave band liited values, using a Real Tie Analyser calibrated sound intensity eter. It is a sound pressure noise level. Indoor unit Panel PIPING -12-

Ite Model AC12CS1ERA Function cooling heating Capacity kw 3.5(0.9--4.5) 3.9(1.0---4.8) Sensible heat ratio 0.71 / Dehuidifying capacity 10 ³ ³/h 1.6 Power Supply 1PH,220-230V 50-60HZ CENTRIFUGALX2 1100/1025/825 0.09 650/550/450 Indoor unit PIPING Type Nuber Fan Speed(H-M-L) r/in Fan otor output power kw Heat exchanger Air-flow(H-M-L) Type / Diaeter Total Area Tep. scope ³/h ² Diension External (L W H) Package (L W H) Drainage pipe (aterial, I.D./O.D.) Control type (Reote /wired) Fresh air hole diension Electricity Heater kw db(a) kg / kg Refrigerant Type inner grooved pipe/φ7 0.20 2-7 990 655 199 1150 750 300 PVC 18/20 Reote, YR-HD NONE NONE Noise level (H-M-L) 41/37/33 Weight (Net / Shipping) 26.3/32.3 R410A Pipe Liquid φ6.35(1/4) Gas Connecting Method φ9.52(3/8) flared Norinal condition: indoor teperature (cooling): 27 DB/19 WB, indoor teperature (heating): 20 DB Outdoor teperature(cooling): 35 DB/24 WB, outdoor teperature(heating): 7 DB/6 WB The noise level will be easured in the third octave band liited values, using a Real Tie Analyser calibrated sound intensity eter. It is a sound pressure noise level. -13-

Ite Model AD12LS1ERA Function cooling heating Capacity kw 3.5(0.9--4.5) 4.0(1.0---4.8) Sensible heat ratio 0.71 Dehuidifying capacity 10 ³ ³/h 1.6 Power Supply 1PH,220-230V 50-60HZ Type Nuber CENTRIFUGALX1 Fan Speed(H-M-L) r/in 1000/900/800±50 Fan otor output power kw 0.05 Air-flow(H-M-L) ³/h 550/450/400 Static pressure Pa 25 Indoor unit PIPING Heat exchanger Type / Diaeter Total Area Tep. scope ² Diension External (L W H) Package (L W H) Drainage pipe (aterial, I.D./O.D.) Control type (Reote /wired) Fresh air hole diension Electricity Heater kw Noise level (H-M-L) db(a) kg / kg Refrigerant Type Pipe Liquid Gas inner grooved pipe/φ7 0.11 2-7 610 483 220 695 536 265 20/24 wired, YR-E14 NONE NONE 37/34/31 Weight (Net / Shipping) 14/16 R410A φ6.35(1/4) φ9.52(3/8) Connecting Method flared Norinal condition: indoor teperature (cooling): 27 DB/19 WB, indoor teperature (heating): 20 DB Outdoor teperature(cooling): 35 DB/24 WB, outdoor teperature(heating): 7 DB/6 WB The noise level will be easured in the third octave band liited values, using a Real Tie Analyser calibrated sound intensity eter. It is a sound pressure noise level. -14-

Ite Model AB18CS1ERA Function cooling heating Capacity kw 5.0(1.8--5.8) 5.2(2.0---6.5) Sensible heat ratio 0.71 / Dehuidifying capacity 10 ³ ³/h 1.8 Power Supply 1PH,220-230V 50-60HZ Type Nuber centrifugal*1 Fan Speed(H-M-L) r/in 795/690/550±50 Fan otor output power kw 0.065 Heat exchanger Air-flow(H-M-L) Type / Diaeter Total Area Tep. scope ³/h ² 680/620/500 inner grooved pipe/φ7 0.272 2-7 Diension External (L W H) 570 570 260 Package (L W H) 718 680 380 Drainage pipe (aterial, I.D./O.D.) PVC 26/32 Control type (Reote /wired) Reote, YR-HD Fresh air hole diension Electricity Heater kw 56 NONE Noise level Weight (H-M-L) (Net / Shipping) db(a) kg / kg 42/37/35 18.5/23 Panel odel (color) PB-700IB(WHITE) Diension External (L W H) 700 700 60 Package (L W H) 740 750 115 Weight (Net / Shipping) kg / kg 3.5/4.5 Refrigerant Type R410A Pipe Liquid Φ6.35 Gas Φ12.7 Connecting Method FLARED Norinal condition: indoor teperature (cooling): 27 DB/19 WB, indoor teperature (heating): 20 DB Outdoor teperature(cooling): 35 DB/24 WB, outdoor teperature(heating): 7 DB/6 WB The noise level will be easured in the third octave band liited values, using a Real Tie Analyser calibrated sound intensity eter. It is a sound pressure noise level. Indoor unit Panel PIPING -15-

Ite Model AC18CS1ERA Function cooling heating Capacity kw 5.0(1.8--5.8) 5.5(2.0---6.5) Sensible heat ratio 0.71 / Dehuidifying capacity 10 ³ ³/h 1.8 Power Supply 1PH,220-230V 50-60HZ Type Nuber CENTRIFUGALX2 Fan Speed(H-M-L) r/in 1220/1190/1050 Fan otor output power kw 0.075 Heat exchanger Air-flow(H-M-L) Type / Diaeter Total Area Tep. scope ³/h ² 800/720/650 inner grooved pipe/φ7 0.45 2-7 Diension External (L W H) 990 655 199 Package (L W H) 1150 750 300 Drainage pipe (aterial, I.D./O.D.) PVC 18/20 Control type (Reote /wired) Reote, YR-HD Fresh air hole diension Electricity Heater kw / / Noise level Weight (H-M-L) (Net / Shipping) db(a) kg / kg 44/41/36 28.3/34.3 Refrigerant Type R410A Pipe Liquid Φ6.35 Gas Φ12.7 Connecting Method FLARED Norinal condition: indoor teperature (cooling): 27 DB/19 WB, indoor teperature (heating): 20 DB Outdoor teperature(cooling): 35 DB/24 WB, outdoor teperature(heating): 7 DB/6 WB The noise level will be easured in the third octave band liited values, using a Real Tie Analyser calibrated sound intensity eter. It is a sound pressure noise level. Indoor unit PIPING -16-

Ite Model AD18LS1ERA Function cooling heating Capacity kw 5.0(1.8---6.0) 5.5(2.0---6.2) Sensible heat ratio 0.73 / Dehuidifying capacity 10 ³ ³/h 2.1 Power Supply 1PH,220-230V 50-60HZ Type Nuber centrifugal fan X 2 Fan Speed(H-M-L) r/in 700±30 / 540±30 / 400±30 Fan otor output power kw 50 Air-flow(H-M-L) ³/h 850/780/600 Static pressure Pa 25 Heat exchanger Type / Diaeter Total Area Tep. scope ² inner grooved pipe/φ7 0.34 2-7 Diension External (L W H) 1090 500 220 Package (L W H) 1174 549 294 Drainage pipe (aterial, I.D./O.D.) 20/24 Control type (Reote /wired) wired, YR-E14 Noise level Weight (H-M-L) (Net / Shipping) db(a) kg / kg 41/35/32 23/26.5 Refrigerant Type R410A Pipe Liquid Φ6.35 Gas Φ12.7 Connecting Method FLARED Norinal condition: indoor teperature (cooling): 27 DB/19 WB, indoor teperature (heating): 20 DB Outdoor teperature(cooling): 35 DB/24 WB, outdoor teperature(heating): 7 DB/6 WB The noise level will be easured in the third octave band liited values, using a Real Tie Analyser calibrated sound intensity eter. It is a sound pressure noise level. Indoor unit PIPING -17-

Ite Model AB24ES1ERA Function cooling heating Capacity kw 6.5(2.0---7.3) 7.1(2.5--8.0)) Sensible heat ratio 0.72 / Dehuidifying capacity 10 ³ ³/h 2.5 Power Supply 1PH,220-230VAC,50HZ Type Nuber centrifugal*1 Fan Speed(H-M-L) r/in 670±40/550±50/460±50 Fan otor output power kw 0.16 Heat exchanger Air-flow(H-M-L) Type / Diaeter Total Area Tep. scope ³/h ² 1300/1100/870 inner grooved pipe/φ7 0.49 2-7 Diension External (L W H) 840*840*240 Package (L W H) 910*910*300 Drainage pipe (aterial, I.D./O.D.) PVC 26/32 Control type (Reote /wired) reote, YR-HD Fresh air hole diension none Noise level Weight (H-M-L) (Net / Shipping) db(a) kg / kg 46/43/39 26.8/32.6 Panel odel (color) PB-950JB (WHITE) Diension External (L W H) 950/950/80 Package (L W H) 985/985/115 Weight (Net / Shipping) kg / kg 6.0/9.0 Indoor unit Panel PIPING Refrigerant Pipe Connecting Method Type Liquid Gas R410A 9.52 15.88 flared Norinal condition: indoor teperature (cooling): 27 DB/19 WB, indoor teperature (heating): 20 DB Outdoor teperature(cooling): 35 DB/24 WB, outdoor teperature(heating): 7 DB/6 WB The noise level will be easured in the third octave band liited values, using a Real Tie Analyser calibrated sound intensity eter. It is a sound pressure noise level. -18-

Ite Function Capacity Sensible heat ratio Dehuidifying capacity Power Supply Indoor unit PIPING Model AC24CS1ERA cooling heating kw 6.3(2.0-7.3) 7.1(2.5-8.0) 0.72 / 10 ³ ³/h 2.0 1PH,220-230VAC,50HZ centrifugal*2 1220±40/1190±50/1050±50/980±50 0.10 800/720/650 inner grooved pipe/φ7 0.49 2-7 990*665*199 1150*750*300 PVC 18/20 reote, YR-HD 48/46/44 28.3/34.3 R410A Liquid 9.52 Gas 15.88 Type Nuber Fan Speed(H-M-L) r/in Fan otor output power kw Heat exchanger Air-flow(H-M-L) Type / Diaeter Total Area Tep. scope ³/h ² Diension External (L W H) Package (L W H) Drainage pipe (aterial, I.D./O.D.) Control type (Reote /wired) Noise level Weight (H-M-L) (Net / Shipping) db(a) kg / kg Refrigerant Type Pipe Connecting Method flared Norinal condition: indoor teperature (cooling): 27 DB/19 WB, indoor teperature (heating): 20 DB Outdoor teperature(cooling): 35 DB/24 WB, outdoor teperature(heating): 7 DB/6 WB The noise level will be easured in the third octave band liited values, using a Real Tie Analyser calibrated sound intensity eter. It is a sound pressure noise level. -19-

Ite Model AD24LS1ERA Function cooling heating Capacity kw 6.8(2.0---7.6) 7.1(3.0---8.3) Sensible heat ratio 0.72 / Dehuidifying capacity 10 ³ ³/h 2.2 Power Supply 1PH,220-230VAC,50HZ Type Nuber centrifugal*2 Fan Speed(H-M-L) r/in 1250±40/1130±40/1000±50/850±50 Fan otor output power kw 0.05 Air-flow(H-M-L) ³/h 1200/1050/850(white terinal 0 Pa) Static pressure Pa 25 Type / Diaeter Heat exchanger Total Area Tep. scope ² inner grooved pipe/φ7 0.51 2-7 Diension External (L W H) 1090*500*220 Package (L W H) 1174*549*294 Drainage pipe (aterial, I.D./O.D.) 20/24 Control type (Reote /wired) wired, YR-E14 Noise level Weight (H-M-L) (Net / Shipping) db(a) kg / kg 49/45/41/37 25.2/28.4 Refrigerant Type R410A Pipe Liquid 9.52 Gas 15.88 Connecting Method flared Indoor unit PIPING Norinal condition: indoor teperature (cooling): 27 DB/19 WB, indoor teperature (heating): 20 DB Outdoor teperature(cooling): 35 DB/24 WB, outdoor teperature(heating): 7 DB/6 WB The noise level will be easured in the third octave band liited values, using a Real Tie Analyser calibrated sound intensity eter. It is a sound pressure noise level. -20-

3. Diension 3U19FS1ERA: Air inlet 16.5 Air inlet 320 353 52 Air outlet 26 289 Handle Handle 688 357 24 51 100 355 } } } Liquid pipe:ø6.35(flared)1/4 Gas pipe :Ø9.52(flared)3/8 A unit connection Liquid pipe:ø6.35(flared)1/4 Gas pipe :Ø9.52(flared)3/8 B unit connection Liquid pipe:ø6.35(flared)1/4 Gas pipe :Ø9.52(flared)3/8 C unit connection 116 293 582 813 73 146 4U25HS1ERA, 4U30HS1ERA: 184 580 184 Air inlet 35 70 Air inlet 340 380 413 Air outlet 948 35 6 340 Gas pipe Ø9.52(flared) 3/8(A,B,C unit) Ø12.7(flared) 1/2(D unit) Handle Handle Indoor and outdoor connect wiring hole (30*48) Handle 408 45 315 163 537 840 A unit connection B unit connection C unit connection D unit connection 50 311 28 21 Liquid pipe Ø6.35(flared) 1/4-21-

5U34HS1ERA: 184 580 184 Air inlet 35 70 Air inlet 340 380 413 948 6 340 Gas pipe Ø9.52(flared) 3/8(A,B,C,D unit) Ø12.7(flared) 1/2(E unit) Indoor and outdoor connect wiring hole (30*48) Handle 408 A unit connection B unit connection C unit connection D unit connection E unit connection 73 35 Air outlet Handle Handle 45 405 537 840 311 28 21 Liquid pipe Ø6.35(flared) 1/4 49-22-

56-23-

AD092LS1ERA AD122LS1ERA AD142LS1ERA AD182LS1ERA AD092LS1ERA AD122LS1ERA AD142LS1ERA AD182LS1ERA -24-

Cassette type unit: AB24 VIEW A 860~890 (ceiling hole) 740 (hanging position) VIEW B VIEW C VIEW B VIEW C 740 (hanging position) 860~890 (ceiling hole) VIEW D VIEW D over 1000 over over over VIEW A over -25-

4. Pipe and wiring installation 4.1 Multi cobination and the data 3U19FS1ERA cobination and the data COOLING Rated capacity(kw) total cooling total power input total current EER energy Cobinations (No. cooling) capacity(kw) (kw) (A)@230V (W/W) label Cob. Unit Unit Unit Unit Unit Unit in. rated ax. in. rated ax. in. rated ax. rated A B C A B C data data data data data Data data data Data capacity 7 2.0 1.00 2.00 2.80 0.50 0.55 1.30 2.22 2.44 5.80 3.64 A 9 2.5 1.00 2.50 3.10 0.50 0.70 1.34 2.22 3.11 6.00 3.57 A 1x1 12 3.5 1.00 3.50 4.10 0.50 1.00 1.50 2.22 4.44 6.70 3.50 A 18 5.0 1.50 5.00 5.40 0.50 1.50 1.90 2.22 6.65 8.40 3.33 A 24 5.4 1.50 5.40 6.50 0.50 1.70 2.00 2.22 7.54 8.90 3.18 B 7 7 2.00 2.00 1.00 4.00 4.40 0.50 1.30 2.60 2.22 5.77 12.00 3.08 B 7 9 2.00 2.50 1.00 4.50 4.90 0.50 1.50 2.60 2.22 6.65 12.00 3.00 B 7 12 1.96 3.44 1.00 5.40 5.80 0.50 1.65 2.60 2.22 7.32 12.00 3.27 A 7 18 1.54 3.86 1.50 5.40 7.00 0.50 1.65 2.60 2.22 7.32 12.00 3.27 A BI (1x2) 9 9 2.50 2.50 1.00 5.00 7.00 0.50 1.55 2.60 2.22 6.88 12.00 3.23 A 9 12 2.25 3.15 1.50 5.40 7.00 0.50 1.57 2.60 2.22 6.94 12.00 3.45 A 9 18 1.80 3.60 1.50 5.40 7.00 0.50 1.65 2.60 2.22 7.32 12.00 3.27 A 12 12 2.70 2.70 1.50 5.40 7.00 0.50 1.57 2.60 2.22 6.94 12.00 3.45 A 12 18 2.22 3.18 1.50 5.40 7.00 0.50 1.65 2.60 2.22 7.32 12.00 3.27 A 7 7 7 1.80 1.80 1.80 1.50 5.40 7.00 0.50 1.65 2.60 2.22 7.32 12.00 3.27 A 7 7 9 1.66 1.66 2.08 1.50 5.40 7.00 0.50 1.65 2.60 2.22 7.32 12.00 3.27 A 7 7 12 1.44 1.44 2.52 1.50 5.40 7.00 0.50 1.65 2.60 2.22 7.32 12.00 3.27 A 7 7 18 1.20 1.20 3.00 1.50 5.40 7.00 0.50 1.65 2.60 2.22 7.32 12.00 3.27 A TRI (1x3) 7 9 9 1.54 1.93 1.93 1.50 5.40 7.00 0.50 1.60 2.60 2.22 7.10 12.00 3.37 A 7 9 12 1.35 1.69 2.36 1.50 5.40 7.00 0.50 1.60 2.60 2.22 7.10 12.00 3.37 A 7 12 12 1.20 2.10 2.10 1.50 5.40 7.00 0.50 1.60 2.60 2.22 7.10 12.00 3.38 A 9 9 9 1.80 1.80 1.80 1.50 5.40 7.00 0.50 1.41 2.60 2.22 6.26 12.00 3.83 A 9 9 12 1.59 1.59 2.22 1.50 5.40 7.00 0.50 1.41 2.60 2.22 6.24 12.00 3.84 A 9 12 12 1.42 1.99 1.99 1.50 5.40 7.00 0.50 1.50 2.60 2.22 6.65 12.00 3.60 A HEATING Cob. 1x1 BI (1x2) TRI (1x3) Cobinations Rated capacity(kw) total heating total power input total current EER energy (No. heating) capacity(kw) (W) (A)@230V (W/W) label Unit A Unit B Unit C Unit A Unit B Unit C in. data rated data ax. data in. data rated data ax. Data in. data rated data ax. Data rated capacity 7 2.3 1.00 2.30 4.00 0.47 0.60 1.50 2.09 2.66 5.80 3.83 A 9 2.9 1.00 2.90 4.10 0.47 0.80 1.40 2.09 3.55 6.00 3.63 A 12 3.8 1.00 3.80 4.10 0.47 1.10 1.50 2.09 4.88 6.70 3.45 A 18 5.5 1.50 5.50 6.00 0.47 1.60 2.60 2.09 7.10 8.40 3.44 A 24 6.5 1.50 6.50 7.00 0.47 1.80 2.60 2.09 7.99 8.90 3.61 A 7 7 2.30 2.30 1.20 4.60 5.00 0.47 1.35 2.30 2.50 5.99 10.20 3.41 B 7 9 2.30 2.90 1.20 5.20 5.70 0.47 1.65 2.30 2.50 7.32 13.00 3.15 B 7 12 2.30 3.80 1.20 6.10 6.50 0.47 1.65 2.30 2.50 7.32 13.00 3.70 A 7 18 1.92 4.58 1.80 6.50 8.10 0.50 1.65 2.60 2.65 7.32 13.00 3.94 A 9 9 2.90 2.90 1.80 5.80 8.10 0.50 1.60 2.60 2.65 7.10 13.00 3.63 A 9 12 2.81 3.69 1.80 6.50 8.10 0.50 1.61 2.60 2.50 7.13 13.00 4.04 A 9 18 2.24 4.26 1.80 6.50 8.10 0.50 1.65 2.60 2.50 7.32 13.00 3.94 A 12 12 3.25 3.25 1.80 6.50 8.10 0.50 1.61 2.60 2.65 7.13 13.00 4.04 A 12 18 2.66 3.84 1.80 6.50 8.10 0.50 1.65 2.60 2.65 7.32 13.00 3.94 A 7 7 7 2.17 2.17 2.17 1.80 6.50 8.10 0.50 1.55 2.60 2.50 6.88 13.00 4.19 A 7 7 9 1.99 1.99 2.51 1.80 6.50 8.10 0.50 1.60 2.60 2.65 7.10 13.00 4.06 A 7 7 12 1.78 1.78 2.94 1.80 6.50 8.10 0.50 1.60 2.60 2.65 7.10 13.00 4.06 A 7 7 18 1.48 1.48 3.54 1.80 6.50 8.10 0.50 1.65 2.60 2.50 7.32 13.00 3.94 A 7 9 9 1.85 2.33 2.33 1.80 6.50 8.10 0.50 1.60 2.60 2.50 7.10 13.00 4.06 A 7 9 12 1.66 2.09 2.74 1.80 6.50 8.10 0.50 1.55 2.60 2.50 6.88 13.00 4.19 A 7 12 12 1.51 2.49 2.49 1.80 6.50 8.10 0.50 1.55 2.60 2.50 6.88 13.00 4.19 A 9 9 9 2.17 2.17 2.17 1.80 6.50 8.10 0.50 1.53 2.60 2.50 6.79 13.00 4.25 A 9 9 12 1.96 1.96 2.57 1.80 6.50 8.10 0.50 1.52 2.60 2.50 6.73 13.00 4.28 A 9 12 12 1.80 2.35 2.35 1.80 6.50 8.10 0.50 1.55 2.60 2.50 6.88 13.00 4.19 A -26-

4U25HS1ERA cobination and the data COOLING Rated capacity Output/kW total cooling total power input total current EER energy Cobinations (No. cooling) capacity(kw) (kw) (A)@230V (W/W) label Cob. Unit Unit Unit Unit Unit Unit Unit Unit in. rated ax. in. rated ax. in. rated ax. rated A B C D A B C D data data data data data Data data data Data capacity 7 2.0 1.00 2.00 2.80 0.50 0.56 1.30 2.22 2.48 5.80 3.57 A 9 2.5 1.00 2.50 3.10 0.50 0.70 1.34 2.22 3.11 6.00 3.57 A 1x1 12 3.5 1.00 3.50 4.10 0.50 1.00 1.50 2.22 4.44 6.70 3.50 A 18 5.0 1.50 5.00 5.40 0.50 1.50 1.90 2.22 6.65 8.40 3.33 A 24 6.5 1.50 6.50 7.40 0.50 2.00 3.00 2.22 8.87 13.20 3.25 A 7 18 2.00 5.00 1.00 7.00 7.40 0.50 2.25 3.50 2.15 10.87 16.80 3.11 B 7 24 1.67 5.43 1.00 7.10 8.50 0.55 2.25 3.50 2.50 10.87 16.80 3.16 B 9 18 2.37 4.73 1.00 7.10 7.90 0.50 2.25 3.50 2.15 10.87 16.80 3.16 B 9 24 1.97 5.13 1.00 7.10 9.00 0.55 2.25 3.50 2.50 10.87 16.80 3.16 B 12 12 3.50 3.50 1.00 7.00 6.80 0.50 2.19 3.50 2.15 10.57 16.80 3.20 A 12 18 3.13 4.47 1.00 7.60 8.40 0.50 2.19 3.50 2.15 10.57 16.80 3.47 A 12 24 2.66 4.94 1.00 7.60 9.00 0.55 2.39 3.50 2.50 11.53 16.80 3.18 B 18 18 3.80 3.80 1.00 7.60 8.60 0.55 2.39 3.50 2.50 11.53 16.80 3.18 B 18 24 3.30 4.30 1.00 7.60 9.00 0.55 2.40 3.50 2.50 11.58 16.80 3.17 B 7 7 9 2.00 2.00 2.50 1.20 6.50 7.10 0.55 2.00 3.50 2.50 9.66 16.80 3.25 A 7 7 12 2.00 2.00 3.50 1.20 7.50 8.10 0.55 2.19 3.50 2.50 10.57 16.80 3.43 A 7 7 18 1.69 1.69 4.22 1.20 7.60 8.80 0.55 2.34 3.50 2.50 11.29 16.80 3.25 A 7 7 24 1.45 1.45 4.70 1.20 7.60 9.00 0.55 2.34 3.50 3.50 11.29 16.80 3.25 A 7 9 9 2.00 2.50 2.50 1.20 7.00 7.10 0.55 2.14 3.50 2.50 10.32 16.80 3.28 A 7 9 12 1.90 2.38 3.33 1.20 7.60 8.60 0.55 2.19 3.50 2.50 10.57 16.80 3.48 A 7 9 18 1.60 2.00 4.00 1.20 7.60 8.80 0.55 2.34 3.50 2.50 11.29 16.80 3.25 A 7 12 12 1.69 2.96 2.96 1.20 7.60 8.60 0.55 2.19 3.50 2.50 10.57 16.80 3.47 A 7 12 18 1.45 2.53 3.62 1.20 7.60 8.80 0.55 2.34 3.50 2.50 11.29 16.80 3.25 A 9 9 9 2.50 2.50 2.50 1.20 7.50 8.10 0.55 2.14 3.50 2.50 10.32 16.80 3.51 A 9 9 12 2.24 2.24 3.13 1.20 7.60 8.60 0.55 2.14 3.50 2.50 10.32 16.80 3.56 A 9 9 18 1.90 1.90 3.80 1.20 7.60 8.80 0.55 2.14 3.50 2.50 10.32 16.80 3.56 A 9 12 12 2.00 2.80 2.80 1.20 7.60 8.60 0.55 2.14 3.50 2.50 10.32 16.80 3.56 A 12 12 12 2.53 2.53 2.53 1.20 7.60 8.50 0.55 2.14 3.50 2.50 10.32 16.80 3.56 A 12 12 18 2.22 2.22 3.17 1.20 7.60 8.50 0.55 2.19 3.50 2.50 10.57 16.80 3.47 A 7 7 7 7 1.90 1.90 1.90 1.90 1.50 7.60 9.00 0.55 2.14 3.50 2.85 10.32 16.80 3.56 A 7 7 7 9 1.79 1.79 1.79 2.24 1.50 7.60 9.00 0.55 2.14 3.50 2.85 10.32 16.80 3.56 A 7 7 7 12 1.60 1.60 1.60 2.80 1.50 7.60 9.00 0.55 2.14 3.50 2.85 10.32 16.80 3.56 A 7 7 7 18 1.38 1.38 1.38 3.45 1.50 7.60 9.00 0.55 2.19 3.50 2.85 10.57 16.80 3.47 A 7 7 9 9 1.69 1.69 2.11 2.11 1.50 7.60 9.00 0.55 2.14 3.50 2.85 10.32 16.80 3.56 A 7 7 9 12 1.52 1.52 1.90 2.66 1.50 7.60 9.00 0.55 2.14 3.50 2.85 10.32 16.80 3.56 A 7 9 9 9 1.60 2.00 2.00 2.00 1.50 7.60 9.00 0.55 2.14 3.50 2.85 10.32 16.80 3.56 A 7 9 9 12 1.45 1.81 1.81 2.53 1.50 7.60 9.00 0.55 2.10 3.50 2.85 10.13 16.80 3.62 A 9 9 9 9 1.90 1.90 1.90 1.90 1.50 7.60 9.00 0.55 2.10 3.50 2.85 10.13 16.80 3.62 A 9 9 9 12 1.73 1.73 1.73 2.42 1.50 7.60 9.00 0.55 2.10 3.50 2.85 10.13 16.80 3.62 A BI (1x2) TRI (1x3) QUADRI(1x4) -27-

4U25HS1ERA cobination and the data HEATING Rated capacity Output/kW total heating total power input total current EER energy Cobinations (No. heating) capacity(kw) (W) (A)@230V (W/W) label Cob. Unit Unit Unit Unit Unit Unit Unit Unit in. rated ax. in. rated ax. in. rated ax. rated A B C D A B C D data data data data data Data data data Data capacity 7 2.3 1.00 2.30 4.00 0.55 0.60 1.50 2.44 2.66 5.80 3.83 A 9 2.9 1.00 2.90 4.10 0.55 0.80 1.40 2.44 3.55 6.00 3.63 A 1x1 12 3.8 1.00 3.80 4.10 0.55 1.10 1.50 2.44 4.88 6.70 3.45 A 18 5.5 1.50 5.50 6.00 0.55 1.60 2.60 2.44 7.10 8.40 3.44 A 24 7.0 1.50 7.00 8.60 0.55 1.91 2.60 2.44 8.47 8.90 3.67 A 7 18 2.30 5.50 1.20 7.80 8.40 0.50 2.20 3.50 2.15 9.76 16.80 3.55 B 7 24 2.13 6.47 1.20 8.60 9.50 0.55 2.31 3.50 2.50 10.24 16.80 3.72 A 9 18 2.90 5.50 1.20 8.40 9.20 0.50 2.20 3.50 2.15 9.76 16.80 3.82 A 9 24 2.52 6.08 1.20 8.60 9.50 0.55 2.31 3.50 2.50 10.24 16.80 3.72 A 12 12 3.80 3.80 1.20 7.60 8.20 0.50 2.15 3.50 2.15 9.54 16.80 3.53 B 12 18 3.51 5.09 1.20 8.60 9.50 0.50 2.30 3.50 2.15 10.20 16.80 3.74 A 12 24 3.03 5.57 1.20 8.60 9.50 0.55 2.31 3.50 2.50 10.24 16.80 3.72 A 18 18 4.30 4.30 1.20 8.60 9.50 0.55 2.20 3.50 2.50 9.76 16.80 3.91 A 18 24 3.78 4.82 1.50 8.60 9.50 0.55 2.40 3.50 2.50 10.65 16.80 3.58 B 7 7 9 2.30 2.30 2.90 1.50 7.50 8.40 0.55 2.16 3.50 2.50 9.58 16.80 3.47 B 7 7 12 2.30 2.30 3.80 1.50 8.40 9.30 0.55 2.16 3.50 2.50 9.58 16.80 3.89 A 7 7 18 1.96 1.96 4.68 1.50 8.60 9.50 0.55 2.26 3.50 2.50 10.02 16.80 3.81 A 7 7 24 1.71 1.71 5.19 1.80 8.60 9.50 0.55 2.31 3.50 2.50 10.24 16.80 3.72 A 7 9 9 2.30 2.90 2.90 1.50 8.10 9.50 0.55 2.21 3.50 2.50 9.80 16.80 3.67 A 7 9 12 2.20 2.77 3.63 1.50 8.60 9.50 0.55 2.21 3.50 2.50 9.80 16.80 3.89 A 7 9 18 1.85 2.33 4.42 1.50 8.60 9.50 0.55 2.26 3.50 2.50 10.02 16.80 3.81 A 7 12 12 2.00 3.30 3.30 1.50 8.60 9.50 0.55 2.21 3.50 2.50 9.80 16.80 3.89 A 7 12 18 1.71 2.82 4.08 1.50 8.60 9.50 0.55 2.26 3.50 2.50 10.02 16.80 3.81 A 9 9 9 2.87 2.87 2.87 1.50 8.60 9.50 0.55 2.21 3.50 2.50 9.80 16.80 3.89 A 9 9 12 2.60 2.60 3.40 1.50 8.60 9.50 0.55 2.21 3.50 2.50 9.80 16.80 3.89 A 9 9 18 2.21 2.21 4.19 1.50 8.60 9.50 0.55 2.26 3.50 2.50 10.02 16.80 3.81 A 9 12 12 2.38 3.11 3.11 1.50 8.60 9.50 0.55 2.11 3.50 2.50 9.36 16.80 4.08 A 12 12 12 2.87 2.87 2.87 1.50 8.60 9.50 0.55 2.26 3.50 2.50 10.02 16.80 3.81 A 12 12 18 2.49 2.49 3.61 1.50 8.60 9.50 0.55 2.31 3.50 2.50 10.24 16.80 3.72 A 7 7 7 7 2.15 2.15 2.15 2.15 1.80 8.60 9.50 0.55 2.21 3.50 2.85 9.80 16.80 3.89 A 7 7 7 9 2.02 2.02 2.02 2.54 1.80 8.60 9.50 0.55 2.21 3.50 2.85 9.80 16.80 3.89 A 7 7 7 12 1.85 1.85 1.85 3.05 1.80 8.60 9.50 0.55 2.16 3.50 2.85 9.58 16.80 3.98 A 7 7 7 18 1.60 1.60 1.60 3.81 1.80 8.60 9.50 0.55 2.21 3.50 2.85 9.80 16.80 3.89 A 7 7 9 9 1.90 1.90 2.40 2.40 1.80 8.60 9.50 0.55 2.21 3.50 2.85 9.80 16.80 3.89 A 7 7 9 12 1.75 1.75 2.21 2.89 1.80 8.60 9.50 0.55 2.21 3.50 2.85 9.80 16.80 3.89 A 7 9 9 9 1.80 2.27 2.27 2.27 1.80 8.60 9.50 0.55 2.11 3.50 2.85 9.36 16.80 4.08 A 7 9 9 12 1.66 2.10 2.10 2.75 1.80 8.60 9.50 0.55 2.11 3.50 2.85 9.36 16.80 4.08 A 9 9 9 9 2.15 2.15 2.15 2.15 1.80 8.60 9.50 0.55 2.06 3.50 2.85 9.13 16.80 4.18 A 9 9 9 12 2.00 2.00 2.00 2.61 1.80 8.60 9.50 0.55 2.11 3.50 2.85 9.36 16.80 4.08 A TRI (1x3) BI (1x2) QUADRI(1x4) -28-

4U30HS1ERA cobination and the data COOLING Rated capacity Output/kW total cooling total power input total current EER energy Cobinations (No. cooling) capacity(kw) (kw) (A)@230V (W/W) label Cob. Unit Unit Unit Unit Unit Unit Unit Unit in. rated ax. in. rated ax. in. rated ax. rated A B C D A B C D data data data data data Data data data Data capacity 7 2.0 1.00 2.00 2.80 0.50 0.56 1.30 2.22 2.48 5.80 3.57 A 9 2.5 1.00 2.50 3.10 0.50 0.70 1.34 2.22 3.11 6.00 3.57 A 1x1 12 3.5 1.00 3.50 4.10 0.50 1.00 1.50 2.22 4.44 6.70 3.50 A 18 5.0 1.50 5.00 5.40 0.50 1.50 1.90 2.22 6.65 8.40 3.33 A 24 6.5 1.50 6.50 7.40 0.50 2.00 3.00 2.22 8.87 13.20 3.25 A 7 24 1.91 6.19 1.00 8.10 9.80 0.55 2.60 3.80 2.15 11.54 17.90 3.12 B 9 18 2.50 5.00 1.00 7.50 9.80 0.55 2.40 3.80 2.15 10.65 17.90 3.13 B 9 24 2.25 5.85 1.00 8.10 9.80 0.55 2.50 3.80 2.15 11.09 17.90 3.24 A 12 18 3.16 4.94 1.00 8.10 9.80 0.55 2.40 3.80 2.15 10.65 17.90 3.37 A 12 24 2.67 5.43 1.00 8.10 9.80 0.55 2.50 3.80 2.15 11.09 17.90 3.24 A 18 18 4.05 4.05 1.00 8.10 9.80 0.55 2.40 3.80 2.15 10.65 17.90 3.38 A 18 24 3.52 4.58 1.00 8.10 9.80 0.55 2.50 3.80 2.15 11.09 17.90 3.24 A 24 24 4.05 4.05 1.00 8.10 9.80 0.55 2.60 3.80 2.15 11.54 17.90 3.12 B 7 7 18 1.80 1.80 4.50 1.50 8.10 9.80 0.55 2.40 3.80 2.50 10.65 17.90 3.38 A 7 7 24 1.54 1.54 5.01 1.50 8.10 9.80 0.55 2.50 3.80 2.50 11.09 17.90 3.24 A 7 9 12 2.00 2.50 3.50 1.50 8.00 9.80 0.55 2.30 3.80 2.50 10.20 17.90 3.48 A 7 9 18 1.71 2.13 4.26 1.50 8.10 9.80 0.55 2.40 3.80 2.50 10.65 17.90 3.37 A 7 9 24 1.47 1.84 4.79 1.50 8.10 9.80 0.55 2.50 3.80 2.50 11.09 17.90 3.24 A 7 12 12 1.80 3.15 3.15 1.50 8.10 9.80 0.55 2.40 3.80 2.50 10.65 17.90 3.38 A 7 12 18 1.54 2.70 3.86 1.50 8.10 9.80 0.55 2.40 3.80 2.50 10.65 17.90 3.37 A 7 12 24 1.35 2.36 4.39 1.50 8.10 9.80 0.55 2.50 3.80 2.50 11.09 17.90 3.24 A 9 9 9 2.50 2.50 2.50 1.50 7.50 9.80 0.55 2.30 3.80 2.50 10.20 17.90 3.26 A 9 9 12 2.38 2.38 3.34 1.50 8.10 9.80 0.55 2.35 3.80 2.50 10.43 17.90 3.44 A 9 9 18 2.03 2.03 4.05 1.50 8.10 9.80 0.55 2.40 3.80 2.50 10.65 17.90 3.38 A 9 9 24 1.76 1.76 4.58 1.50 8.10 9.80 0.55 2.50 3.80 2.50 11.09 17.90 3.24 A 9 12 12 2.13 2.98 2.98 1.50 8.10 9.80 0.55 2.40 3.80 2.50 10.65 17.90 3.37 A 9 12 18 1.84 2.58 3.68 1.50 8.10 9.80 0.55 2.40 3.80 2.50 10.65 17.90 3.37 A 9 12 24 1.62 2.27 4.21 1.50 8.10 9.80 0.55 2.50 3.80 2.50 11.09 17.90 3.24 A 12 12 12 2.70 2.70 2.70 1.50 8.10 9.80 0.55 2.40 3.80 2.50 10.65 17.90 3.38 A 12 12 18 2.36 2.36 3.38 1.50 8.10 9.80 0.55 2.40 3.80 2.50 10.65 17.90 3.37 A 12 12 24 2.10 2.10 3.90 1.50 8.10 9.80 0.55 2.45 3.80 2.50 10.87 17.90 3.31 A 12 18 18 2.10 3.00 3.00 1.50 8.10 9.80 0.55 2.50 3.80 2.50 11.09 17.90 3.24 A 7 7 7 7 2.00 2.00 2.00 2.00 1.50 8.00 9.80 0.55 2.25 3.80 2.85 9.98 17.90 3.56 A 7 7 7 9 1.91 1.91 1.91 2.38 1.50 8.10 9.80 0.55 2.25 3.80 2.85 9.98 17.90 3.60 A 7 7 7 12 1.71 1.71 1.71 2.98 1.50 8.10 9.80 0.55 2.25 3.80 2.85 9.98 17.90 3.60 A 7 7 7 18 1.47 1.47 1.47 3.68 1.50 8.10 9.80 0.55 2.40 3.80 2.85 10.65 17.90 3.37 A 7 7 7 24 1.30 1.30 1.30 4.21 1.50 8.10 9.80 0.55 2.50 3.80 2.85 11.09 17.90 3.24 A 7 7 9 9 1.80 1.80 2.25 2.25 1.50 8.10 9.80 0.55 2.25 3.80 2.85 9.98 17.90 3.60 A 7 7 9 12 1.62 1.62 2.03 2.84 1.50 8.10 9.80 0.55 2.25 3.80 2.85 9.98 17.90 3.60 A 7 7 9 18 1.41 1.41 1.76 3.52 1.50 8.10 9.80 0.55 2.40 3.80 2.85 10.65 17.90 3.37 A 7 7 9 24 1.25 1.25 1.56 4.05 1.50 8.10 9.80 0.55 2.45 3.80 2.85 10.87 17.90 3.31 A 7 7 12 12 1.47 1.47 2.58 2.58 1.50 8.10 9.80 0.55 2.25 3.80 2.85 9.98 17.90 3.60 A 7 7 12 18 1.30 1.30 2.27 3.24 1.50 8.10 9.80 0.55 2.40 3.80 2.85 10.65 17.90 3.38 A 7 9 9 9 1.71 2.13 2.13 2.13 1.50 8.10 9.80 0.55 2.25 3.80 2.85 9.98 17.90 3.60 A 7 9 9 12 1.54 1.93 1.93 2.70 1.50 8.10 9.80 0.55 2.28 3.80 2.85 10.12 17.90 3.55 A 7 9 9 18 1.35 1.69 1.69 3.38 1.50 8.10 9.80 0.55 2.40 3.80 2.85 10.65 17.90 3.37 A 7 9 12 12 1.41 1.76 2.47 2.47 1.50 8.10 9.80 0.55 2.30 3.80 2.85 10.20 17.90 3.52 A 7 12 12 12 1.30 2.27 2.27 2.27 1.50 8.10 9.80 0.55 2.30 3.80 2.85 10.20 17.90 3.52 A 9 9 9 9 2.03 2.03 2.03 2.03 1.50 8.10 9.80 0.55 2.22 3.80 2.85 9.85 17.90 3.65 A 9 9 9 12 1.84 1.84 1.84 2.58 1.50 8.10 9.80 0.55 2.25 3.80 2.85 9.98 17.90 3.60 A 9 9 12 12 1.69 1.69 2.36 2.36 1.50 8.10 9.80 0.55 2.25 3.80 2.85 9.98 17.90 3.60 A 9 9 12 18 1.50 1.50 2.10 3.00 1.50 8.10 9.80 0.55 2.30 3.80 2.85 10.20 17.90 3.52 A 9 12 12 12 1.56 2.18 2.18 2.18 1.50 8.10 9.80 0.55 2.35 3.80 2.85 10.43 17.90 3.45 A 12 12 12 12 2.03 2.03 2.03 2.03 1.50 8.10 9.80 0.55 2.35 3.80 2.85 10.43 17.90 3.45 A BI (1x2) TRI (1x3) QUADRI(1x4) -29-

4U30HS1ERA cobination and the data HEATING Rated capacity Output/kW total heating total power input total current EER energy Cobinations (No. heating) capacity(kw) (W) (A)@230V (W/W) label Cob. Unit Unit Unit Unit Unit Unit Unit Unit in. rated ax. in. rated ax. in. rated ax. rated A B C D A B C D data data data data data Data data data Data capacity 7 2.3 1.00 2.30 4.00 0.55 0.60 1.50 2.44 2.66 5.80 3.83 A 9 2.9 1.00 2.90 4.10 0.55 0.80 1.40 2.44 3.55 6.00 3.63 A 1x1 12 3.8 1.00 3.80 4.10 0.55 1.10 1.50 2.44 4.88 6.70 3.45 A 18 5.5 1.50 5.50 6.00 0.55 1.60 2.60 2.44 7.10 8.40 3.44 A 24 7.0 1.50 7.00 8.60 0.55 1.80 2.60 2.44 7.99 8.90 3.89 A 7 24 2.30 7.00 1.20 9.30 10.50 0.50 2.60 3.80 2.15 11.54 15.00 3.58 B 9 18 2.90 5.50 1.20 8.40 10.50 0.50 2.60 3.80 2.15 11.54 15.00 3.23 C 9 24 2.87 6.93 1.20 9.80 10.50 0.50 2.70 3.80 2.15 11.98 15.00 3.63 A 12 18 3.80 5.50 1.20 9.30 10.50 0.50 2.60 3.80 2.15 11.54 15.00 3.58 B 12 24 3.45 6.35 1.20 9.80 10.50 0.50 2.70 3.80 2.15 11.98 15.00 3.63 A 18 18 4.90 4.90 1.20 9.80 10.50 0.50 2.60 3.80 2.15 11.54 15.00 3.77 A 18 24 4.31 5.49 1.20 9.80 10.50 0.50 2.70 3.80 2.15 11.98 15.00 3.63 A 24 24 4.90 4.90 1.20 9.80 10.50 0.50 2.75 3.80 2.44 12.20 15.00 3.56 B 7 7 18 2.23 2.23 5.34 1.20 9.80 10.50 0.55 2.60 3.80 2.50 11.54 15.00 3.77 A 7 7 24 1.94 1.94 5.91 1.50 9.80 10.50 0.55 2.70 3.80 2.50 11.98 15.00 3.63 A 7 9 12 2.30 2.90 3.80 1.50 9.00 10.50 0.55 2.60 3.80 2.50 11.54 15.00 3.46 B 7 9 18 2.11 2.66 5.04 1.50 9.80 10.50 0.55 2.60 3.80 2.50 11.54 15.00 3.77 A 7 9 24 1.85 2.33 5.62 1.50 9.80 10.50 0.55 2.70 3.80 2.50 11.98 15.00 3.63 A 7 12 12 2.28 3.76 3.76 1.50 9.80 10.50 0.55 2.70 3.80 2.50 11.98 15.00 3.63 A 7 12 18 1.94 3.21 4.65 1.50 9.80 10.50 0.55 2.60 3.80 2.50 11.54 15.00 3.77 A 7 12 24 1.72 2.84 5.24 1.50 9.80 10.50 0.55 2.70 3.80 2.50 11.98 15.00 3.63 A 9 9 9 2.90 2.90 2.90 1.50 8.70 10.50 0.55 2.20 3.80 2.50 9.76 15.00 3.95 A 9 9 12 2.90 2.90 3.80 1.50 9.60 10.50 0.55 2.70 3.80 2.50 11.98 15.00 3.56 B 9 9 18 2.52 2.52 4.77 1.50 9.80 10.50 0.55 2.43 3.80 2.50 10.78 15.00 4.03 A 9 9 24 2.22 2.22 5.36 1.50 9.80 10.50 0.55 2.70 3.80 2.50 11.98 15.00 3.63 A 9 12 12 2.71 3.55 3.55 1.50 9.80 10.50 0.55 2.70 3.80 2.50 11.98 15.00 3.63 A 9 12 18 2.33 3.05 4.42 1.50 9.80 10.50 0.55 2.60 3.80 2.50 11.54 15.00 3.77 A 9 12 24 2.07 2.72 5.01 1.50 9.80 10.50 0.55 2.70 3.80 2.50 11.98 15.00 3.63 A 12 12 12 3.27 3.27 3.27 1.50 9.80 10.50 0.55 2.58 3.80 2.50 11.45 15.00 3.80 A 12 12 18 2.84 2.84 4.11 1.50 9.80 10.50 0.55 2.60 3.80 2.50 11.54 15.00 3.77 A 12 12 24 2.55 2.55 4.70 1.50 9.80 10.50 0.55 2.65 3.80 2.50 11.76 15.00 3.70 A 12 18 18 2.52 3.64 3.64 1.50 9.80 10.50 0.55 2.75 3.80 2.50 12.20 15.00 3.56 B 7 7 7 7 2.30 2.30 2.30 2.30 1.50 9.20 10.50 0.55 2.38 3.80 2.85 10.56 15.00 3.87 A 7 7 7 9 2.30 2.30 2.30 2.90 1.50 9.80 10.50 0.55 2.70 3.80 2.85 11.98 15.00 3.63 A 7 7 7 12 2.11 2.11 2.11 3.48 1.80 9.80 10.50 0.55 2.60 3.80 2.85 11.54 15.00 3.77 A 7 7 7 18 1.82 1.82 1.82 4.35 1.80 9.80 10.50 0.55 2.60 3.80 2.85 11.54 15.00 3.77 A 7 7 7 24 1.62 1.62 1.62 4.94 1.80 9.80 10.50 0.55 2.70 3.80 2.85 11.98 15.00 3.63 A 7 7 9 9 2.17 2.17 2.73 2.73 1.80 9.80 10.50 0.55 2.60 3.80 2.85 11.54 15.00 3.77 A 7 7 9 12 1.99 1.99 2.52 3.30 1.80 9.80 10.50 0.55 2.60 3.80 2.85 11.54 15.00 3.77 A 7 7 9 18 1.73 1.73 2.19 4.15 1.80 9.80 10.50 0.55 2.60 3.80 2.85 11.54 15.00 3.77 A 7 7 12 12 1.85 1.85 3.05 3.05 1.80 9.80 10.50 0.55 2.60 3.80 2.85 11.54 15.00 3.77 A 7 7 12 18 1.62 1.62 2.68 3.88 1.80 9.80 10.50 0.55 2.60 3.80 2.85 11.54 15.00 3.77 A 7 9 9 9 2.05 2.58 2.58 2.58 1.80 9.80 10.50 0.55 2.60 3.80 2.85 11.54 15.00 3.77 A 7 9 9 12 1.89 2.39 2.39 3.13 1.80 9.80 10.50 0.55 2.60 3.80 2.85 11.54 15.00 3.77 A 7 9 9 18 1.66 2.09 2.09 3.96 1.80 9.80 10.50 0.55 2.70 3.80 2.85 11.98 15.00 3.63 A 7 9 12 12 1.76 2.22 2.91 2.91 1.80 9.80 10.50 0.55 2.50 3.80 2.85 11.09 15.00 3.92 A 7 12 12 12 1.65 2.72 2.72 2.72 1.80 9.80 10.50 0.55 2.50 3.80 2.85 11.09 15.00 3.92 A 9 9 9 9 2.45 2.45 2.45 2.45 1.80 9.80 10.50 0.55 2.43 3.80 2.85 10.79 15.00 4.03 A 9 9 9 12 2.27 2.27 2.27 2.98 1.80 9.80 10.50 0.55 2.50 3.80 2.85 11.09 15.00 3.92 A 9 9 12 12 2.12 2.12 2.78 2.78 1.80 9.80 10.50 0.55 2.50 3.80 2.85 11.09 15.00 3.92 A 9 9 12 18 1.88 1.88 2.47 3.57 1.80 9.80 10.50 0.55 2.55 3.80 2.85 11.31 15.00 3.84 A 9 12 12 12 1.99 2.60 2.60 2.60 1.80 9.80 10.50 0.55 2.60 3.80 2.85 11.54 15.00 3.77 A 12 12 12 12 2.45 2.45 2.45 2.45 1.80 9.80 10.50 0.55 2.60 3.80 2.85 11.54 15.00 3.77 A BI (1x2) QUADRI(1x4) TRI (1x3) -30-

5U34HS1ERA cobination and the data COOLING Cob. Unit A Cobinations Unit B Unit C Unit D Unit E Unit A Rated capacity Output/kW (No. cooling) Unit B Unit C Unit D Unit E in. data total cooling capacity(kw) rated data ax. data total power input (kw) in. data rated data ax. Data in. data total current (A)@230V rated data ax. Data EER (W/W) rated capacity 7 2.0 1.00 2.00 2.80 0.50 0.65 1.30 2.20 2.88 5.80 3.08 B 9 2.5 1.00 2.50 3.10 0.50 0.80 1.34 2.20 3.55 6.00 3.13 B 1x1 12 3.5 1.00 3.50 4.10 0.50 1.04 1.50 2.20 4.61 6.70 3.37 A 18 5.0 1.50 5.00 5.40 0.50 1.50 1.90 2.20 6.65 8.40 3.33 A 24 6.5 1.50 6.50 7.40 0.50 2.00 3.00 2.20 8.87 13.20 3.25 A 7 18 2.00 5.00 1.00 7.00 7.50 0.50 2.30 4.00 2.15 10.20 19.00 3.04 B 7 24 2.00 6.50 1.00 8.50 9.00 0.50 2.80 4.00 2.15 12.42 19.00 3.04 B 9 18 2.50 5.00 1.00 7.50 8.00 0.50 2.40 4.00 2.15 10.65 19.00 3.13 B 9 24 2.50 6.50 1.00 9.00 9.50 0.50 2.70 4.00 2.15 11.98 19.00 3.33 A BI (1x2) 12 18 3.50 5.00 1.00 8.50 9.00 0.50 2.70 4.00 2.15 11.98 19.00 3.15 B 12 24 3.50 6.50 1.00 10.00 10.50 0.50 3.10 4.00 2.15 13.75 19.00 3.23 A 18 18 5.00 5.00 1.00 10.00 10.50 0.50 3.10 4.00 2.15 13.75 19.00 3.23 A 18 24 4.35 5.65 1.00 10.00 10.50 0.50 3.10 4.00 2.15 13.75 19.00 3.22 A 24 24 5.00 5.00 1.00 10.00 10.50 0.50 3.20 4.00 2.15 14.20 19.00 3.13 B 7 7 12 2.00 2.00 3.50 1.50 7.50 8.10 0.55 2.74 4.00 2.50 12.16 19.00 2.74 D 7 7 18 2.00 2.00 5.00 1.50 9.00 9.80 0.55 2.74 4.00 2.50 12.16 19.00 3.28 A 7 7 24 1.90 1.90 6.19 1.50 10.00 10.50 0.55 2.74 4.00 2.50 12.16 19.00 3.65 A 7 9 9 2.00 2.50 2.50 1.50 7.00 7.60 0.55 2.74 4.00 2.50 12.16 19.00 2.55 E 7 9 12 2.00 2.50 3.50 1.50 8.00 8.60 0.55 2.74 4.00 2.50 12.16 19.00 2.92 C 7 9 18 2.00 2.50 5.00 1.50 9.50 10.20 0.55 2.74 4.00 2.50 12.16 19.00 3.47 A 7 9 24 1.82 2.27 5.91 1.50 10.00 10.50 0.55 3.04 4.00 2.50 13.49 19.00 3.29 A 7 12 12 2.00 3.50 3.50 1.50 9.00 9.60 0.55 3.04 4.00 2.50 13.49 19.00 2.96 C 7 12 18 1.90 3.33 4.76 1.50 10.00 10.50 0.55 3.04 4.00 2.50 13.49 19.00 3.29 A 7 12 24 1.67 2.92 5.42 1.50 10.00 10.50 0.55 3.04 4.00 2.50 13.49 19.00 3.29 A TRI (1x3) 9 9 9 2.50 2.50 2.50 1.50 7.50 8.10 0.55 3.04 4.00 2.50 13.49 19.00 2.47 E 9 9 12 2.50 2.50 3.50 1.50 8.50 9.10 0.55 3.04 4.00 2.50 13.49 19.00 2.80 D 9 9 18 2.50 2.50 5.00 1.50 10.00 10.50 0.55 3.04 4.00 2.50 13.49 19.00 3.29 A 9 9 24 2.17 2.17 5.65 1.50 10.00 10.50 0.55 3.04 4.00 2.50 13.49 19.00 3.29 A 9 12 12 2.50 3.50 3.50 1.50 9.50 10.20 0.55 3.04 4.00 2.50 13.49 19.00 3.13 B 9 12 18 2.27 3.18 4.55 1.50 10.00 10.50 0.55 3.04 4.00 2.50 13.49 19.00 3.29 A 9 12 24 2.00 2.80 5.20 1.50 10.00 10.50 0.55 3.04 4.00 2.50 13.49 19.00 3.29 A 12 12 12 3.33 3.33 3.33 1.50 10.00 10.50 0.55 3.04 4.00 2.50 13.49 19.00 3.29 A 12 12 18 2.92 2.92 4.17 1.50 10.00 10.50 0.55 2.99 4.00 2.50 13.27 19.00 3.34 A 12 12 24 2.59 2.59 4.81 1.50 10.00 11.00 0.55 3.27 4.00 2.50 14.51 19.00 3.06 B 12 18 18 2.59 3.70 3.70 1.50 10.00 11.00 0.55 3.27 4.00 2.50 14.51 19.00 3.06 B 18 18 18 3.33 3.33 3.33 1.80 10.00 11.00 0.55 3.32 4.00 2.50 14.73 19.00 3.01 B 7 7 7 7 2.00 2.00 2.00 2.00 1.80 8.00 8.80 0.55 2.89 4.00 2.50 12.82 19.00 2.77 D 7 7 7 9 2.00 2.00 2.00 2.50 1.80 8.50 9.30 0.55 2.89 4.00 2.50 12.82 19.00 2.94 C 7 7 7 12 2.00 2.00 2.00 3.50 1.80 9.50 10.30 0.55 2.96 4.00 2.50 13.13 19.00 3.21 A 7 7 7 18 1.82 1.82 1.82 4.55 1.80 10.00 11.00 0.55 2.99 4.00 2.50 13.27 19.00 3.34 A 7 7 7 24 1.60 1.60 1.60 5.20 1.80 10.00 11.00 0.55 2.99 4.00 2.50 13.27 19.00 3.34 A 7 7 9 9 2.00 2.00 2.50 2.50 1.80 9.00 9.80 0.55 2.96 4.00 2.50 13.13 19.00 3.04 B 7 7 9 12 2.00 2.00 2.50 3.50 1.80 10.00 10.50 0.55 2.96 4.00 2.50 13.13 19.00 3.38 A 7 7 9 18 1.74 1.74 2.17 4.35 1.80 10.00 11.00 0.55 2.99 4.00 2.50 13.27 19.00 3.34 A 7 7 9 24 1.54 1.54 1.92 5.00 1.80 10.00 11.00 0.55 2.99 4.00 2.50 13.27 19.00 3.34 A 7 7 12 12 1.82 1.82 3.18 3.18 1.80 10.00 10.80 0.55 2.96 4.00 2.50 13.13 19.00 3.38 A QUADRI 7 7 12 18 1.60 1.60 2.80 4.00 1.80 10.00 11.00 0.55 2.99 4.00 2.50 13.27 19.00 3.34 A (1x4) 7 9 9 9 2.00 2.50 2.50 2.50 1.80 9.50 10.30 0.55 2.96 4.00 2.50 13.13 19.00 3.21 A 7 9 9 12 1.90 2.38 2.38 3.33 1.80 10.00 10.80 0.55 2.99 4.00 2.50 13.27 19.00 3.34 A 7 9 9 18 1.67 2.08 2.08 4.17 1.80 10.00 11.00 0.55 2.99 4.00 2.50 13.27 19.00 3.34 A energy label -31-