Operating Instructions

Similar documents
PA Purifier System. System Description. Printed Book No. Oct V 4

MIB 303 Separation System. System Description. Printed Book No. Aug V1. Alfa Laval Marine & Power

>:3$!$D"$ $$ DVaRcRe`c>R_fR]?a^sdrc=^ '' &%% " 1^^Z=^!&!#!E!

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Flex separation systems, P-separators 605/615

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

LK Electric Boiler - 4,5

E-16 Main Engine Remote Control System

Refrigerated air dryers

AS DIGITAL FIRE PUMP CONTROLLER

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Operating Display SCREENS

M2000 Engine Controller

SECURIT 700L USER MANUAL

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

User Guide

Operating Instructions Manual Janfire NH/Integral Pellets Burner with External Auger

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

MacDonald Steel Limited

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

M2000 Engine Controller

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Product Manual SZ1009

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Operating, Installation and Service Manual W3400H, CLC 41 Clarus Control

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

"VIP 2" ADVANCED LUBRICATION CONTROLLER

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

CRU-S Series Stainless Steel Condensate Recovery Unit

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

Guardian II Pipeline Washer B Instruction Supplement

Ditec DAS107PLUS User Manual IP2270EN.

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Control Panel User Guide (TO BE RETAINED BY THE USER)

Product Manual SZ1022/SZ1031/SZ1035/

OPERATING INSTRUCTIONS. Drying cabinet DC 7774 DC Read the instructions before using the machine.

Operating manual. Wascator FOM71 CLS

DYGIZONE GJD910 Lighting Controller & Enunciator

AUTOMATIC VACUUM UNIT

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

PUGMILL/MIXER. Instruction Manual NVS-07

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Boiler controller S-Tronic Plus

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

DFZ. Cabin Control Description and operation

ASSEMBLY INSTRUCTIONS FOR THE PUMP AND CONTROL UNIT ZPS 18a-01

Installation Instruction

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

Swedish design and manufacture since 1967

KFP-CF Series Operation Manual

SSV-DC user manual. Phason

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

D A R A - 4. Data Aire Relay Auto-Changeover

Fire Control Panel FS4000

SENSA MRE DDM MR

Operational Overview and Controls Guide

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

SAVE VTC 700. Heat Recovery Ventilation Unit

HEAT PUMP PROGRAMMABLE THERMOSTAT

2604 Controller Melt Pressure Controller

Service Manual for / How to Remove the Cover

Fire Alarm Control Panel EN54 2 & Operation & Programming MAN

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

INSTALLATION/OPERATING INSTRUCTIONS BCP-3. Hot Water Reset Control For up to 3 Boilers. How the BCP-3 operates... 1:4 1:3 1:2 1:1.

PUREAIR SENSE. Instruction Manual. A product by. B at hroom Fan wi t h O dour Sen se Tec h n ology Vent-Axia PureAir Sense F&W Manual.

Compact Genset Controller, CGC 400 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

Air Comfort. Installation instructions (English) A

Flopurge TS. Operation Manual

SWIMMING POOL HEAT PUMP Owners Manual

DFZ. In Cab Control Description and Operation

Door Release Power Supply

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

English Table of contents Features/Accessories

SWEBO Bioenergy Manual pellet burner PB20 Rev no. Date Page PBM1: (36) Installation and maintenance instructions

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Model: Edge-HC. 1 edge-hc

SITC-15 Temperature Controller GITC-15 Temperature Controller Mainframe Operation Manual

WHA 3000V Hot Air Station

F20-S UL = ME109 Page-No: Revision G Test Program - Coding Instruction F20-S/-S UL Material-No.: of 11

OPERATING INSTRUCTIONS

Operation GT7000. Time / Current Temp. TEMP UP button. Display. Fan. Switch. Set Temp. Display. Mode Switch. Backlight. TEMP DOWN button.

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Boiler controller Lambdatronic S 3200

Operation and Maintenance Haskris LX-Series, R-Series, WW-Series, OPC-Series

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

INITIAL START-UP CHECKLIST FOR 23XL HERMETIC SCREW LIQUID CHILLER

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

Instructions for the fan motor control system, SILVER C

Transcription:

S-type Separation System Operating Instructions Printed Book No. Nov 2002 1810571-02 V 5

Alfa Laval reserves the right to make changes at any time without prior notice. Any comments regarding possible errors and omissions or suggestions for improvement of this publication would be gratefully appreciated. Copies of this publication can be ordered from your local Alfa Laval company. Published by: Alfa Laval Tumba AB Marine & Diesel Equipment SE - 147 80 Tumba Sweden Copyright Alfa Laval Tumba AB 2002.

Contents 1 Operating...2 1.1 Before Startup...2 1.2 Operators Panel...5 1.3 Startup...7 1.4 Manual Startup...8 1.5 During operation...12 1.6 Stop...15 1.7 Emergency Stop...16 1.8 After Emergency Stop...17 1.9 Cleaning In Place...19 1.10 Automatic Operation...20 1.11 Remote Operation...22 1.12 Emergency Operation...23 1.12.1 Manual Operation of the Separation System...23 1810571-02

1 OPERATING S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1 Operating 1.1 Before Startup 1 Check that the separator is correctly assembled and connected to power supply of correct voltage and frequency. The EPC 50 Control Unit must be ON. WARNING Breakdown hazard Assemble the separator completely before start. All couplings, covers, and guards must be in place and properly tightened. Non compliance may lead to breakdown. WARNING Electrical hazard Follow local regulations for electrical installation and earthing (grounding). WARNING P003594A Breakdown hazard Check that the power frequency is in agreement with the machine plate. If incorrect, resulting overspeed may cause breakdown. 50 Hz? 60 Hz? WARNING P003606A Use the separation system for the purpose, and within the limits, specified by Alfa Laval. Failure to do so could cause a violent breakdown. 2 1810571-02

S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1 OPERATING 2 Check the oil sump level. If necessary, unscrew the level stick-plug, and top up until oil starts to run from the oil-filling hole. NOTE Too much or too little oil can damage the separator bearings. G0868542 Rotation Direction To check the rotation of the bowl, do a quick start/stop. The motor fan must rotate in a clockwise direction. CAUTION If power cable polarity has been reversed, the separator will rotate in reverse, and vital rotating parts can loosen. NOTE To make this check, the Mode Selector Switch should be in the CIP position. P003593A 1810571-02 3

1 OPERATING S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS Air Valve Block Use the pressure gauge situated in the air valve block to check that the air supply is correct (500 700 kpa or 5 7 Bar). For further information concerning air, see chapter 1 Technical Data in the System Reference/ Installation Instructions booklet. P003682A Operating Water Pressure Check that the operating water pressure is sufficient (200 600 kpa or 2 6 Bar). For further information concerning water, see chapter 1 Technical Data in the System Reference/ Installation Instructions booklet. 4 1810571-02

S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1 OPERATING 1.2 Operators Panel The operators panel (local) is positioned on the upper part of the control cabinet. If the unit contains an optional junction box, the control cabinet can be positioned at a distance of up to 50 metres cable length from the unit. A duplicate operators panel (remote) may be connected for fully functional operation from a remote location i.e. control room. By using the REMIND TM software (see the REMIND TM User s Manual) it is possible to operate the control cabinet from a remote position with the aid of a PC. For further information concerning communication alternatives using REMIND TM and the Remote Operators Panel, see the Remote Operation Systems chapter in the System Reference/Installation Instructions booklet. 1810571-02 5

1 OPERATING S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS General principle for changing control parameters The Enter button is used to: enter into a parameter list enter into a parameter accept/store a new parameter value. The + or the buttons are used to change the value flashing in the display window. Process parameters Set the process parameters to suit the installation as follows: 1 Push Enter. Parameter no. 1 in the process parameter list is shown. You have now come to the process parameter list. Go through the list and set parameters. 2 When the parameters have been set, End I/O (flashing) shows. Push +. Standst. now shows in the display. 16 15 10 TT MT OP HEATER SEPARATION For information on how to set discharge intervals, see chapter 3 Process Parameters in the Paramete list booklet. EPC-50 INFO Standst. ENTER STOP DISCHARGE OP ACTIVE ALARM P00361HB NOTE Make sure that the operators panel is active (LED green) before operating. 6 1810571-02

S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1 OPERATING 1.3 Startup The control panel mode switch has three positions: MANUAL, AUTO, and CIP. The MANUAL mode is for use on all Separation Unit systems. MAN CIP AUT G046604A The AUTO mode is for use on systems supplied for fully automatic control and/or fully automatic remote control. The following general rules apply for use of the AUTO mode: The EPC 50 must have control of the oil feed pump. The EPC 50 must have control of the heater. The EPC 50 must have control of vibration monitoring. The cover interlock must be fitted. MAN AUT G046605A The CIP mode is for use with Cleaning in Place equipment. See Cleaning In Place on page 19. MAN CIP CIP G046606A 1810571-02 7

CIP MAN AUT 1 OPERATING S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1.4 Manual Startup The first startup must always be carried out manually. Before startup make sure that all the main supply valves for air, oil, and water are open. Open heating media supply valve if applicable. Switch on the power supplies. Make sure the mode selection switch is in the MANUAL position. 1 Start the oil feed pump from the pump starter. The oil flow can be read on the display (parameter In 32). If applicable, set the desired flow using regulating valve RV4. G046600A 2 If necessary, vent air from the heater through the relief valve (if applicable). Switch on the heater from the operator panel (if applicable). 16 15 10 TT MT HEATER OP SEPARATION STOP NOTE EPC-50 INFO DISCHARGE OP A CTIVE The operators panel must be active to allow operation. ENTER ALARM P00361JB 3 Press the SEPARATION button to activate the EPC-50. OP TT MT HEATER 16 15 10 SEPARATION STOP EPC-50 INFO DISCHARGE OP A CTIVE ENTER ALARM P00361LB 8 1810571-02

CIP MAN AUT S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1 OPERATING Before the separator can be started, a number of questions scroll across the display which have to be answered: Has the bowl been dismantled? + = YES, = NO 4 If the bowl has been dismantled press the + button. P003614A If no work has been carried out on the bowl, press the button. The start sequence begins and the text Start appears in the display. NOTE P003613A If this is the first start, answer YES. Assembled according to manual? + = YES, = NO 5 If the bowl has been dismantled and assembled according to the instructions in the Service Manual, press the + button. P003614A Bowl cleaned? + = YES, = NO 6 If the bowl has been cleaned press the + button. An automatic calibration of the system is carried out. See display. P003614A. 7 Push the separator start button. G046601A 1810571-02 9

1 OPERATING S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 8 Listen and observe. Vibration may occur during start up, when passing critical speeds.this is normal and should pass without danger. If vibration increases, or continues at full speed, press the emergency stop button and stand clear until the vibration stops. The separator and heater are stopped when the emergency stop button is pushed. The feed pump stops max. 3 minutes afterwards. P003606A The emergency stop will only reset when the speed sensor indicates zero speed. Once the zero speed signal has been received, the alarm reset button can be pushed. The message Switch power on/off. will be displayed. This refers to the EPC 50 power indside the control cabinet. The cause of vibration must be determined and corrected before starting again See the Alarms and Fault Finding booklet. WARNING Breakdown hazard Always observe the separator during start-up after assembly. If strong vibration occurs, stop by using the Emergency Stop button and evacuate the room. NOTE If the system is equipped with a vibration sensor, and has control of heater and feed pump, the Auto Start can be used. 10 1810571-02

S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1 OPERATING 9 The separator speed, and Start. are shown alternately in the display until the separator is at full speed. If Ti 55 is set to 0, the system goes automatically to separation process 16 15 10 TT MT HEATER OP SEPARATION STOP EPC-50 INFO DISCHARGE OP A CTIVE ENTER ALARM 10 Check the oil feed temperature by pressing the + button until TT1 is shown on the display. 11 Wait until the oil feed temperature is correct: Heavy fuel mode 98 C Lube oil mode 95 C (trunk engines), or 90 C (cross-head engines) P00361KB Diesel oil mode 40 C 12 Standby is displayed when the separator has reached the correct speed, and the oil is at the correct temperature. The process starts automatically. 16 15 10 TT MT HEATER OP SEPARATION STOP EPC-50 INFO DISCHARGE OP A CTIVE ENTER ALARM 13 Adjust the backpressure to the normal running value. Normal running backpressure is determined at commissioning. See the System Reference/Installation Instructions booklet. P00361LB 1810571-02 11

1 OPERATING S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1.5 During operation Operator panel information Observe the operator panel information: Heater operation LED lit (green) Separator system operation LED lit (green) Activated valve LED lit (green) During normal operation, the ALCAP trigger signal is shown on the left of the display, and the time to next sludge discharge is shown on the right. Any alarm is indicated on the display. For further information see the Alarms and Fault Finding booklet. NOTE Regularly check connections. Tighten if necessary. 12 1810571-02

S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1 OPERATING NOTE OP The values displayed in the examples below are not recommendations. 16 15 10 TT MT HEATER SEPARATION STOP More operational information may be read as required, by pressing the + button repeatedly. EPC-50 INFO DISCHARGE OP A CTIVE ENTER ALARM To return to normal display, i.e. the trigger value, and time to next sludge discharge, continue pressing the + button. P00361MB Oil feed temperature. For the correct separation temperature see the System Reference/Installation Instructions booklet. TT1 98 C P00361RA Oil pressure, oil inlet 1 1.4 P00361QA Oil pressure, oil outlet 4 1.4 P00361PA Pressure, water outlet 5 1.4 P00361OA Water transducer value MT 89 P00361TA Speed Rpm 10300 P00361UA Accumulated operating time in hours Run time 5 hours P003625A 1810571-02 13

INFO C EPC-50 B TT MT ENTER HEATER OP SEPARATION STOP DISCHARGE OP ACTIVE ALARM 1 OPERATING S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS CAUTION WARNING Burn hazard Avoid contact with hot surfaces. Process pipes, various machine surfaces, and processed liquid can be hot and cause burns. Breakdown hazard If strong vibration occurs, press the emergency stop button and evacuate the room. Never discharge a vibrating separator. Vibration may then become violent and result in breakdown. CAUTION WARNING Slip hazard Check all connections for leakage. Oil leakage may make the floor slippery. Noise hazard Use ear protection if noise levels are high P004072A 14 1810571-02

S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1 OPERATING 1.6 Stop To stop the system: 1 Stop the system by pushing the SEPARATION button on the operators panel. The yellow LED for separator stop sequence starts to flash. A sludge discharge is initiated. The stop sequence LED changes to steady yellow, and the green LED for separation system operation goes out, when the sludge discharge is completed. 16 15 10 EPC-50 INFO TT MT ENTER OP HEATER SEPARATION STOP DISCHARGE OP A CTIVE ALARM Stop is displayed. If the heater is controlled by the EPC 50, it is switched off automatically. P00361SB When the oil feed temperature has started to drop, the oil feed pump is switched off automatically. The separator comes to a complete standstill after about 20 60 minutes. Standst. is then displayed. CAUTION Breakdown hazard Stop the separator by means of the control unit, and not by turning off the motor. CAUTION Never attempt to clean the bowl by manual discharge in connection with stop. 1810571-02 15

1 OPERATING S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS If the system is switched off for reasons other than high vibration, it is not necessary to wait for the separator to slow down before restarting the process. See 1.4 Manual Startup, page 8. WARNING Breakdown hazard The system must not be restarted with the separator rotating if high vibration alarm has been given. 1.7 Emergency Stop If an emergency situation occurs, press the emergency stop button and evacuate the room. Do not return until the separator has come to a complete standstill. WARNING Disintegration hazard If unusually strong vibration occurs, press the Emergency Stop button and leave the room Do not enter the room after an emergency stop while the separator is still rotating. G04659BA NOTE In order to be able to restart, the system must be at standstill, and then the EPC power switched off on. 16 1810571-02

S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1 OPERATING 1.8 After Emergency Stop Separator standstill Dismantling work must not be started before all rotating parts have come to a complete standstill. DANGER Entrapment hazard Make sure that rotating parts have come to a complete standstill before starting any dismantling work. The rotation indicator lamp, where applicable, must be off. I00293AA 1810571-02 17

1 OPERATING S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS Avoid accidental start WARNING Entrapment hazard To avoid accidental start, switch off and lock power supply before starting any dismantling work. Make sure that separator has come to a complete standstill before starting any dismantling work Remedy the cause The cause of the emergency must be remedied before attempting to restart the separator. If the cause is not found, an overhaul must be performed on the separator, and all moving parts thoroughly checked WARNING Disintegration hazard Do not start the separator after an emergency stop without first remedying the cause of the emergency. Make sure that the bowl is clean before restart. 18 1810571-02

S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1 OPERATING Separator reassembled The separator must be fully reassembled with all covers and guards in place and tightened before unlocking the power supply and starting the system. WARNING Breakdown hazard Assemble the separator completely before restart. All couplings, covers, and guards must be in place and properly tightened. Non compliance may lead to breakdown. P003594A 1.9 Cleaning In Place The use of Cleaning In Place (CIP) equipment is recommended for best separation results. For further information on the CIP equipment, see the CIP booklet, bookno. 1817261. Before connecting the CIP equipment to the Separation Unit, the switch on the control cabinet must be turned to the CIP position. This is to avoid accidental pumping of oil when the pipeline is opened up. For instructions on how to connect the CIP equipment to the Separation Unit, see the Service Manual booklet. For recommended CIP intervals see chapter 1 Technical Data in the System Reference/ Installation Instructions booklet. 1810571-02 19

1 OPERATING S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1.10 Automatic Operation For automatic operation, the system must be equipped for automatic start. Make sure the mode selection switch is in the AUTO position and Pr3 has the correct setting. NOTE If local control is needed (for example in an emergency situation), turn the switch to manual mode. This will automatically override the Pr3 setting. NOTE The first startup must always be carried out manually. The system can thereafter be run automatically as long as no changes are made to it between runs. 1 Press the SEPARATION button OP TT MT HEATER 16 15 10 SEPARATION STOP EPC-50 INFO DISCHARGE OP A CTIVE ENTER ALARM P00361LB Before the separator can be started, a number of questions scroll across the display which have to be answered: 20 1810571-02

S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1 OPERATING Has the bowl been dismantled? + = YES, = NO 2 If the bowl has been dismantled press the + button. P003614A If no work has been carried out on the bowl, press the button. The start sequence begins and the text Start appears in the display. P003613A Assembled according to manual? + = YES, = NO 3 If the bowl has been dismantled and assembled according to the instructions in the Service Manual, press the + button. P003614A Bowl cleaned? + = YES, = NO 4 If the bowl has been cleaned press the + button. An automatic calibration of the system is carried out. See display. P003614A To stop the process, press the SEPARATION button (see 1.6 Stop, page 15.) OP TT MT If the system is to be restarted, the system valves can remain in operating positions. 16 15 10 HEATER SEPARATION STOP EPC-50 INFO DISCHARGE OP A CTIVE ENTER ALARM P00361LB 1810571-02 21

1 OPERATING S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1.11 Remote Operation Remind/Remote Operation NOTE After maintenance, the system must be started locally. If in Remote, and + is pushed in answer to the question Has the bowl been dismantled?, the system reverts to local control. Follow the instructions in chapter 1.10 Automatic Operation, page 20. 22 1810571-02

S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1 OPERATING 1.12 Emergency Operation In the event of a water transducer failure, the system can still be operated by setting parameter Pr 4 in the EPC to standby mode (see the Parameter List booklet). The transducer is then disabled and the time to discharge automatically changes to 15 minutes. Nc (not connected) is shown on the display. All Alcap functions are disabled. Water is removed only during a discharge. A reminder alarm is activated after 24 hours. If the system oil contains plenty of water, and the oil density is less than 991 kg/m 3, emergency operation as described below is possible. 1.12.1 Manual Operation of the Separation System In the event of extemely high water content, the system can be run manually by a competent engineer using the following instructions: 1 Ensure all oil system manual valves are in the correct position. 2 Set the selection switch on the control unit to the MANUAL position. 3 Fit a jumper between terminals X9:1, and X9:2 in the EPC. 4 Start the feed pump. 5 Start the separator. 6 Heat the oil to the correct separating temperature. Where there is a Heatpac EHM electric heater, use jumpers in the power unit to bridge terminals X12.11 X12.6, X12.11 X12.9, and X12.11 X12.7. Switch on the heater and use the switch to regulate the temperature. NOTE Remove the jumpers after emergency operation. 1810571-02 23

1 OPERATING S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 7 When the separator is up to speed and the correct oil flow and temperature are achieved, close the bowl. Open SV15 for 5 seconds.wait 15 seconds. Open SV16 for15 seconds. The bowl is now closed. 8 Temperature, flow, and backpressure must remain constant throughout. C B A G065001A 9 Screw C (see illustration on the right), should be in the outermost position (12 on the scale). Screw C is fixed by stop B. 10 Remove the water outlet pipe at D or E. G065021A D E G065031A 24 1810571-02

S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS 1 OPERATING 11 Screw in screw A to move the paring tube to its innermost position. 12 Open SV10 as follows: Time (secs.) SU 200/SU 820/SU 825 40 0.7 SU 300/ SU 830/SU 835 40 1,1 SU 400/SU 840/SU 845 70 1.9 SU 500/SU 850/SU 855 30 3.0 SU 600/SU 860/SU 865 50 4.5 13 Open SV1 to open oil feed V1. 14 Open SV5. This will open the water outlet valve V5. 15 Carefully screw out screw A until water starts to come from D or E. 16 Lock screw A in position. Amount bowl filled (litre) A G065011A WARNING Breakdown hazard During operation, SV 16 should be open to ensure that the bowl remains closed. 1810571-02 25

1 OPERATING S-TYPE SEPARATION SYSTEM OPERATING INSTRUCTIONS Discharge 1 Close oil feed V1 using SV1. 2 Close water outlet V5 using SV5. 3 Open SV10 to add displacement water as follows: Time (secs.) SU 200/SU 820/SU 825 60 0.9 SU 300/ SU 830/SU 835 49 1.3 SU 400/SU 840/SU 845 79 2.1 SU 500/SU 850/SU 855 44 4.0 SU 600/SU 860/SU 865 59 5.4 Amount bowl filled (litre) 4 Open SV15 until a discharge is heard (within 5 seconds). 5 Wait 15 seconds. 6 Open SV16 for 15 seconds. 7 Open SV10 as follows: Time (secs.) SU 200/SU 820/SU 825 40 0.7 SU 300/ SU 830/SU 835 40 1,1 SU 400/SU 840/SU 845 70 1.9 SU 500/SU 850/SU 855 30 3.0 SU 600/SU 860/SU 865 50 4.5 Amount bowl filled (litre) 8 Open V1. 9 Open V5. 10 Maintain backpressure at normal setting throughout. WARNING Breakdown hazard Discharging of the bowl, and supervision of the operation, is now completely manual and under the direct responsibility of the engineer who has placed the separation system in the manual control mode. 26 1810571-02