TEMPERATURE & PRESSURE CONTROLS

Similar documents
Opening Point Adjustment Range psig (kpa) Commercial Type Non-Corrosive RefrigerantsS (R) 160 to 260 (1103 to 1793) 70 to 150 (483 to 1034)

A11 Series Low Temperature Cutout Controls

TEMPERATURE & PRESSURE CONTROLS

TEMPERATURE & PRESSURE CONTROLS

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

Davies Is Your #1 Source For Temperature Controls

270XT Freeze Protection, IP30

F261 Series Fluid Flow Switches

y Small dimensions. Easy to install in refrigerated counters or cold rooms

Pressure switch KPU. Data sheet

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Centro-Matic Automated Lubrication Systems System Controls

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

Tubular Industrial Process

Thermostat KPU. Data sheet

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

MACH N-407 Heat Pump Air-Cooled Chiller

HEATING- Heating Accessories RW List Prices Page X - 1. Bronze B&G Circulator Pumps. Iron Body Red Fox B&G Circulator Pump

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

HEATING- Heating Accessories RW List Prices Page X - 1. Iron Body Red Fox B&G Circulator Pump. Bronze B&G Circulator Pumps

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

Dual Pressure Controls

For Technical Service Telephone Facsimile

Commercial Refrigeration Catalog

MR3CCUHV Temperature/Defrost Control

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

TC-5231 Series, TC-5232, & TC-5241 Series

Table of Contents. Part Number Index SANDYS INDUSTRIAL GLASS WHEELER A

Water-Cooled Dual Compressor Screw Chiller

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

JCseries EVAPORATIVE CONDENSER. engineering data

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

49 Danfoss Thermostat Kits Ranco Varifix Kits

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

water to water heat pumps

A99B Series Temperature Sensor

MAC N-407 Air-Cooled Chiller

Easy. Products and technologies for all your application needs, today and tomorrow. Quick Select Guide 2017

TECHNICAL. Series 18. Pump Packages

Call us today! (800)

FS80-C Flow Switch. Features and Benefits. Allows user select the setting according the needs of system

Refrigerant Valves/Accessories

Tubular Industrial Process

Brasch Hazardous Location Unit Heaters

Powers Controls ET 134 Low Temperature Detection Thermostat

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Call us today! (800)

Call us today! (800)

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

section8 CONTROLS & MEASUREMENT

SYSTEM DESIGN REQUIREMENTS

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit

FX5 Series Explosion-Proof Electric Air Heaters

YCIV Hz & Hz

IS Series Pressure Sensing Switches

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Easy Find the right products fast with our Quick Selection Guide. Products and technologies for all your application needs, today and tomorrow

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Isco 3700ZR Sampler. Manual Set

water source / fan coils

SpaceKeeper Console (SKC)

AIR COOLED PACKAGED CHILLER

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST TEL NO: ORDER NO: CONTRACT NO:

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GUIDE SPECIFICATIONS AQUARIUS ii

CR1 Series Triton Corrosion Resistant Washdown Heaters

THERMOSTATS THERMOSTATS HEATING AND COOLING

SECTION STEAM CONDENSATE PUMPS

Powers Controls Low Temperature Detection Thermostat

MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: CUSTOMER ORDER NO: PHONE: JCI CONTRACT NO: JOB NAME:

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 14 Automatic Control Components and Applications

temperature Controllers

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

Variable Area Flowmeters Ratosight TM Flow Rate Indicators with Optional Ratolarm - 10A2235

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

V246 Series Two-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

ULTRA-SAFE Explosion-proof Duct Heaters

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

Liebert CSU3000 Chiller

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Contour TM Screw Compressors

Comfort. Description. Applications

Paragon. Induced Draft, Counter Flow Optional Accessories

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Transcription:

TEMPERATURE & CONTROLS JOHNSON CONTROLS A11 SERIES LOW TEMPERATURE CUTOUT CONTROL The A11 Series low temperature cutout controls incorporate a 20-ft long, vapor charged sensing element. The A11 reacts to the coldest 18-in. section of the controls sensing element. The A11 is suitable for monitoring the face temperature of hot water coils for freeze protection. A11A-1C A11B-1C SWITCH ACTION SPST - Open Low SPST - Open Low 35 to 45 (2 to 7) 35 to 45 (2 to 7) DIFF F (C ) Manual Reset 8(4.4) (Fixed) BULB AND CAPILLARY 20 ft of 1/8-in. O.D. Tubing, 4 ft Cap. 20 ft of 1/8-in. O.D. Tubing, 4 ft Cap. ADJUSTER Screwdriver Slot Screwdriver Slot JOHNSON CONTROLS A19 REMOTE BULB CONTROL The A19 Series are single stage temperature controls that incorporate liquid filled sensing elements. P4411 SWITCH ACTION DIFF F (C ) *Replaces White-Rodgers 1609-101. Replaces White-Rodgers 1609-12, -13; Ranco O10-1408, -1409, -1410, -1490, O60-110; Honeywell L6018C-1006, L6021A-1005, T675-1011, -1508, -1516, -1821, T4301A-1008, T6031A-1011, T6031A-1029. BULB AND CAPILLARY **Case-Compensated.!Universal Replacement. BULB WELL NO. (Order Separately) ADJUSTER MAX. BULB TEMP Wide Range Adjustable Differential A19ABA-40C* SPST Open Low 30 to 100 ( 34 to 38) 3 to 12 (1.7 to 6.7) 3/8 in. x 4 in., 6 ft Cap. WEL14A-602R Screwdriver Slot 140 (60) A19ABC-4C SPDT 50 to 130 (10 to 55) 3-1/2 to 14 (1.9 to 8) 3/8 in. x 5 in., 8 ft Cap. WEL14A-603R Knob 170 (77)!A19ABC-24C SPDT 30 to 100 ( 34 to 38) 3 to 12 (1.7 to 6.7) 3/8 in. x 4 in., 8 ft Cap. WEL14A-602R Convertible 140 (60)!A19ABC-36C SPDT 30 to 100 ( 34 to 38) 3 to 12 (1.7 to 6.7) 3/8 in. x 4 in., 20 ft Cap. WEL14A-602R Convertible 140 (60) A19ABC-37C SPDT 30 to 100 ( 34 to 38) 3 to 12 (1.7 to 6.7) 3/8 in. x 4 in., 10 ft Cap. WEL14A-602R Screwdriver Slot 140 (60) A19ABC-74C SPDT 30 to 100 ( 34 to 38) 3 to 12 (1.7 to 6.7) 3/8 in. x 4 in., 6 ft Cap. WEL14A-602R Screwdriver Slot 140 (60) Fixed Differential A19AAF-12C SPDT 25 to 225 ( 4 to 107) 3-1/2 (1.9) 3/8 in. x 3 in., 10 ft Cap. WEL14A-602R Screwdriver Slot 275 (135) CASE COMPENSATED FIXED DIFFERENTIAL A19AAC-4C SPDT 0 to 80 ( 18 to 27) 5 (2.8) 3/8 in. x 4 in., 6 ft Cap. WEL14A-602R Screwdriver Slot 140 (60) A19AAD-12C SPST Open Low 30 to 50 ( 34 to 10) 2-1/2 (1.4) 3/8 in. x 4 in., 7 ft Cap. WEL14A-602R Screwdriver Slot 140 (60) Close Differential A19AAD-5C** SPST 30 to 50 ( 1 to 10) Open Low (Bulk Milk Cooler) 2-1/2 (1.4) 3/8 in. x 2-5/8 in., 6 ft Cap. WEL16A-601R Screwdriver Slot 190 (88) A19AAF-20C SPDT 30 to 100 ( 34 to 38) 2-1/2 (1.4) 3/8 in. x 4 in., 6 ft Cap. WEL14A-602R Screwdriver Slot 140 (60) A19AAF-21C SPDT 40 to 90 (4 to 32) 1-1/2 (0.8) 3/8 in. x 5-3/4 in., 6 ft Cap. WEL14A-603R Screwdriver Slot 140 (60) Manual Reset A19ACA-14C SPST Open Low 30 to 100 ( 34 to 38) Manual Reset 3/8 in. x 4 in., 6 ft Cap. WEL14A-602R Screwdriver Slot 140 (60) A19ACA-15C SPST Open Low 30 to 100 ( 34 to 38) Manual Reset 3/8 in. x 4 in., 10 ft Cap. WEL14A-602R Screwdriver Slot 140 (60) A19ADB-1C SPST Open High 100 to 240 (38 to 116) Manual Reset 3/8 in. x 3-1/2 in. 6 ft Cap. WEL14A-602R Knob 290 (143) A19ADN-1C SPST Open HIgh 100 to 240 (38 to 116) Manual Reset 3/8 in. x 4 in., 6 ft Cap. WEL14A-602R Screwdriver Slot 290 (143) 1031

TEMPERATURE & CONTROLS JOHNSON CONTROLS A19 SERIES COILED BULB SPACE THERMOSTAT Wide range temperature control with air coil sensing element. A19BAB-3C SWITCH ACTION SPST, Open High! A19BAC-1C SPDT AT19BAF-1C SPDT! A19BBC-2C SPDT 35 to 95 (0 to 35) 30 to 110 ( 1to43) 30 to 110 ( 1to43) 30 to 100 ( 34 to 38) DIFF F (C ) BULB AND CAPILLARY ADJUSTER MAX. BULB TEMP VENTILATING, HEATING 3 (1.7) Fixed 1-3/8 in. x 2-1/4 in. Coiled Knob 3-1/2 (1.9) Fixed 1-3/8 in. x 2-1/4 in. Coiled Convertible 140 (60) 1-1/2 (0.9) Fixed 1-3/8 in. x 2-1/4 in. Coiled Knob COOLING 3to12 (1.7 to 7) 1-3/8 in. x 2-1/4 in. Coiled Convertible 140 (60) *Replaces White-Rodgers 201-16, -8, 2A37-1; Ranco 010-1418, -1802, 016-594, C30-C1101; Honeywell T631A, T696A, T6054 A1005.!Universal Replacement. JOHNSON CONTROLS A19 SERIES WATER CHILLER CONTROL (With Locked Cutout/Adjustable Cut-in) Remote bulb temperature control with limited set point range, adjustable differential, and adjustable cut-out. A19ZBA-1C SWITCH ACTION SPST Close High, Open Low 38 to 80 (3 to 27) DIFF F (C ) 8to40 (4 to 22) Adjustable BULB AND CAPILLARY 3/8-in. x 3-7/16 in., 6ftCap. BULB WELL NO. (Order Separately) WEL14A-602R ADJUSTER Knob 1032

TEMPERATURE & CONTROLS JOHNSON CONTROLS A19 DEFROST DURATION AND FAN DELAY CONTROL Remote bulb control with adjustable defrost termination temperature and preset fan delay temperature. A19ZBC-2C SWITCH ACTION SPDT DEFROST TERMINATION 45 to 85 (7 to 29) BULB AND CAPILLARY 19/64 in. x 3-1/8 in. 6ftCat ADJUSTER Knob JOHNSON CONTROLS A19 SERIES AUTOMATIC CHANGEOVER WITH STRAP-ON MOUNTING This is a changeover control for use with combination heating and cooling thermostats. SWITCH ACTION DIFF F (C ) MOUNTING A19CAC-1C SPDT 60 to 90 (16 to 32) 10 (5.6) 42 in. cap. A19CAC-2C SPDT 60 to 90 (16 to 32) 10 (5.6) Direct JOHNSON CONTROLS A19 HOT WATER TEMPERATURE CONTROL WITH STRAP-ON MOUNT A SPDT, strap-on, surface type hot water control for direct or reverse action. Can be used as either an open high control or an open low control.!a19dac-1c SWITCH ACTION SPDT 100 to 240 (38 to 116) DIFF F FIXED (C ) 10 (5.6) MOUNTING Clamp-on Strap Supplied NOTE: Replaces White -Rodgers 1127-2. A19DAC-1 not for use as a limit control.!universal Replacement. 1033

TEMPERATURE & CONTROLS FLANGE MOUNTED DUCT THERMOSTAT A wide-range temperature control with a special air coil sensing element and an adjustable mounting flange. A19EAF-1C A19EAF-2C SWITCH ACTION SPDT SPDT 60 to 1230 (16to54) 30 to 110 ( 1to43) DIFF F (C ) MAXIMUM BULB TEMPERATURE 2 (1.1) 200 (93) 2 (1.1) 140 (60) JOHNSON CONTROLS A19 SERIES HOT WATER TEMPERATURE CONTROL (Well Immersion) This is a universal replacement control for open high or SPDT applications. The control is furnished with a well assembly for 1/2-inch tapping.!a19abc-11c!a19abc-12c A19ADB-2C APPLICATION Open High (R-B) Open Low (R-Y) High Temp Lockout SWITCH ACTION SPDT SPDT Open High with Lockout 100 to 240 (38 to 116) 100 to 240 (38 to 116) 100 to 240 (38 to 116) DIFF F (C ) 6to24 (3 to 13) 6to24 (3 to 13) Manual Reset (locks out high) WELL CONN. SIZE-NPT ADJUSTER MAX. BULB TEMP 1/2 in. Convertible 250 (121) 1/2 in. 8ft.Cap. Convertible 290 (143) 1/2 in. Knob 250 (121)!Universal Replacement. 1034

TEMPERATURE & CONTROLS JOHNSON CONTROLS A419 ELECTRONIC TEMPERATURE CONTROL The A419 Series control is a line voltage, single-stage, electronic temperature control with a Single-Pole, Double-Throw (SPDT) output relay. It has heating or cooling modes of operation with an adjustable set point and differential, a lockable keypad, an adjustable anti-short cycle delay, and binary input for temperature offset. The A419 combines remote sensing capability and interchangeable sensors with electronic accuracy, all in a NEMA 1 high-impact plastic enclosure that is suitable for surface-mounting or DIN-rail mounting. P4412 The A419 can be used to control a wide variety of single-stage refrigeration or HVAC equipment. Typical applications include: freezer control in convenience stores reach-in coolers supermarket display cases for produce or meats restaurant or convenience store walk-in coolers boiler control compressor lockout (disables the compressor when temperature exceeds limits) condenser fan cycling pump control for cooling towers space and return-air temperature A419ABC-1C A419 Electronic Temperature Control with Display and Sensor (120/240 VAC model) A419GBF-1C A419 Electronic Temperature Control with Display and Sensor (24 VAC model) A99BB-200C PTC Sensor with 6.5 ft (1.98 m) Leads BKT287-1R 35 x 7.5 mm, 0.305 m (12 in.) long DIN Rail BKT287-2R 35 x 7.5 mm, 0.914 m (36 in.) long DIN Rail PLT344-1R Two End Clamps, for DIN Rail Mounting CLK350-2 7-Day Programmable Digital Clock; Electronic Switch Output WEL11A-601R Immersion Well (Use with Thermal Compound) JOHNSON CONTROLS A319 ELECTRONIC TEMPERATURE CONTROL The A319 Series is a line voltage, single-stage electronic temperature control with Single-Pole, Double-Throw (SPDT) relay output and LED indication. The A319 features heating or cooling modes of operation, adjustable cut-in, adjustable differential, and an interchangeable temperature sensor. The A319 couples electronic accuracy with remote sensing capability in a NEMA 1 high-impact plastic enclosure suitable for surface or DIN rail mounting. P4415 ITEM A319 Temperature Control with Sensor A319ABC-12-01 Cut-in Range: 100 to 220 F (38 to 105 C) Differential: 1 to 30 F (0.5 to 17 C) Sensor Lead Length: 8 ft (2.4 m) A319 Temperature Control With Sensor A319ABC-24-01 Cut-in Range: 20 to 100 F ( 30 to 38 C) Differential: 1 to 30 F (0.5 to 17 C) Sensor Lead Length: 8 ft (2.4 m) A319 Temperature Control With Sensor A319ABC-07-01 Cut-in Range: 25 to 50 F ( 32.5 to 10 C) Differential:1to15 F(0.5to8 C) Sensor Lead Length: 8 ft (2.4 m) A319 Temperature Control Without Sensor A319ABC-12-02 Cut-in Range: 100 to 220 F (38 to 105 C) Differential: 1 to 30 F (0.5 to 17 C) A319 Temperature Control Without Sensor A319ABC-24-02 Cut-in Range: 20 to 100 F ( 30 to 38 C) Differential: 1 to 30 F (0.5 to 17 C) A319 Temperature Control Without Sensor A319ABC-07-02 Cut-in Range: 25 to 50 F ( 32.5 to 10 C) Differential:1to15 F(0.5to8 C) 1035

TEMPERATURE & CONTROLS JOHNSON CONTROLS A28 SERIES TWO-STAGE FLANGE MOUNTED DUCT THERMOSTAT The A28AK is a two-stage temperature control with special air coil sensing element and adjustable mounting flange. P4408 DIFFERENTIAL F (C ) MAXIMUM ALLOWABLE NUMBER OF SWITCH FIXED TEMPERATURE AT BULB STAGES ACTION Each Stage Between Stage A28AK-1C 2 2-SPDT Switches 30 to 110 ( 1 to 43) 2 (1.1) 3 (1.7) 140 (60) A28AK-2C 2 2-SPDT Switches 60 to 130 (16 to 54) 2 (1.1) 3 (1.7) 200 (93) JOHNSON CONTROLS P70 SERIES SINGLE-POLE DUAL CONTROL This P70 Series of dual pressure controls employs a SPST switch, that is opened when either high pressure or low pressure beyond the control settings is sensed at the control s two bellows sensing elements. The load-carrying contacts provide direct control of AC motors within the control s rating. These controls provide close high-open low (low pressure) or open high-close low (high pressure) contact action. P4410 P70LB-6C P70MA-18C! P70LB-1C! P70MA-1C! P70NA-1C P70SA-1C P70LA-2C P70MA-2C SWITCH ACTION SPST SPST Two Independent SPDT Switches SPST LOW HIGH Range Diff Range Diff (Non-Adj) MICRO-SET FOR R-12, R-22, R-134a, R-500, R-502 (R) 65 psi at < 300 psig 75 psi at 300-400 psig 95 psi at > 400 psig 12 in. to 80 ( 41 to 552) 20 in. to 100 ( 68 to 690) 12 in. to 80 ( 41 to 552) 20 in. to 100 ( 68 to 690) Min5(34) Max 35 (241) 100 to 500 (690 to 3447) Lockout (Requires Manual Reset) ALL FOR R-12, R-22, R-134a, R-500, R-502 (R) 65 psi < 300 psig 75 psi 300-400 psig 95 psi > 400 psig Min7(48) Max 50 (345) 100 to 500 (690 to 3447) Lockout (Manual Reset) Min5(34) Max 35 (241) Min7(48) Max 50 (345) Lockout (Requires Manual Reset) Lockout (Requires Manual Reset) Switchable Between Manual and Automatic Reset FOR AMMONIA 65 psi < 300 psig 75 psi 300-400 psig 95 psi > 400 psig 100 to 500 (690 to 3445) 100 to 500 (690 to 3445) Lockout (Requires Manual Reset) CONNECTOR 36 in. Cap. with 1/4 in. Flare Nut 36 in. Cap. with 1/4 in. Flare Nut 36 in. Cap. with 1/4 in. Flare Nut 36 in. Cap. with 1/4 in. Flare Nut 36 in. Cap. with 1/4 in. Flare Nut 36 in. Cap. with 1/4 in. Flare Nut 1/4 in. Female NPT Conn. 1/4 in. Female NPT Conn. LMITED KNOB ADJ. Cut-out None Cut-out None None None MAXIMUM OVER 325 Low 525 High (2241 Low) (3620 High) 325 Low 525 High (2241 Low) (3620 High) 525 Low 525 High 325 Low 525 High (2241 Low) (3620 High)! Universal Replacement. 1036

TEMPERATURE & CONTROLS JOHNSONCONTROLSA72AASERIESCOILEDBULBSPACETHERMOSTAT (Cooling) The A72 is a space sensing thermostat with heavy-duty contacts A72AA-4C SWITCH ACTION DPST Close High Open Low 15 to 55 ( 9 to 13) DIFF F (C ) 3to30 (1.7 to 17) BULB AND CAPILLARY Coiled Copper Bulb ADJUSTER Screwdriver Slot JOHNSON CONTROLS A72CA HOT WATER SINGLE FUNCTION CONTROL (Two-Pole-Heavy Duty) The A72CA is a direct immersion hot water control with heavy duty contacts. A72CA-1C SWITCH ACTION Open On Rise 140 to 220 (60to104) DIFFERENTIAL F (C ) WELL CONN. SIZE Min. Max 6 (3) 45 (25) 1/2 in. NPT JOHNSON CONTROLS A72 SERIES COOLING TOWER OR EVAPORATIVE CONDENSER CONTROLS (Single Stage Temperature Control with Outdoor Enclosure) The A72CE and A72CE are wide range temperature controls with heavy duty DPST contacts and neoprene coated sensing elements. A72AE-1C A72CE-1C SWITCH ACTION DPST Close High 25 to 90 DPST ( 5 to 30) Open HIgh DIFF F (C ) 4to25 (2.2 to 14) BULB AND CAPILLARY 1-1/16 in. x 6-3/4 in. Neoprene Coated 6ft.Cap. ADJUSTER Internal Screwdriver Slot 1037

TEMPERATURE & CONTROLS JOHNSON CONTROLS P70, P72, and P170 SERIES CONTROLS FOR LOW The P70, P72, and P170 controls for low pressure applications are designed primarily for low pressure cut-out control, pump-down control, and capacity control on commercial refrigeration and air conditioning applications. These controls are available in several pressure ranges and are compatible with most common refrigerants. They may also be used on other non-corrosive fluid applications. Ammonia-compatible models are also available. Controls also are available in several different electrical ratings and switch configurations. The P72 models provide direct control of 208-240 volt single-phase motors up to 3 hp and 208-220 volt, 3-phase motors up to 5 horsepower. P70A and P170A models with Single-Pole Single-Throw (SPST) Open-low switch action are the most popular models, and are typically used for low pressure cut-out and pump-down control. P70 and P170 models are also available with SPST Open-high switch action, and are typically used for capacity control. Models with Single-Pole Double-throw (SPDT) or 4-wire, 2 circuit switch action allow users to install alarm devices or other control circuits. P72 models have a Double-Pole Single-Throw (DPST) switch with load-carrying contacts that can provide direct control of 208-240 V single-phase motors up to 3 hp, and 208-220 V 3-phase motors up to 5 hp. NEMA 1 enclosures are standard on most models. NEMA 3R enclosures are also available. P1019 FOR STANDARD P70, P72, and P170 CONTROLS FOR LOW P70AB-12 P170AB-12 P70AB-1 P70AB-2 P70CA-1 P70EA-10 P72AA-1 P72AB-1 P170AB-2 SWITCH ACTION SPST Open Low SPST Open Low SPST Open High SPDT 1to3OpenLow 1 to 2 Close Low DPST Open Low SPST Open Low DIFFERENTIAL (psi) (kpa) CONNECTOR MAX. OVER MICRO-SET CONTROLS (For Non-Corrosive Refrigerants) 12in.Hgto80 Minimum 5 (34) 36 in. Cap. with 1/4-in. Flare Nut 525 psig ( 41 to 551) Maximum 35 (241) 1/4-in. Male flare Connector (3617 kpa) ALL- CONTROLS (For Non-Corrosive Refrigerants) 20 in. Hg to 100 ( 68 to 690) Minimum 7 (48) Maximum 50 (345) t(34) Fixed Minimum 7 (48) Maximum 50 (345) 1/4 in. Male Flare Connector 36 in. Cap. with 1/4 in. Flare Nut 1/4 in. Male Flare Connector 36 in. Cap. with 1/4 in. Flare Nut 325 psig (2239 kpa) MAX WORKING 80 psig (551 kpa) 100 psig (6990 kpa) LIMITED KNOB ADJUSTMENT Supplied but not assembled Supplied, but not assembled None Mounted on Differential Screw 1/4 in. Male Flare Connector P170CA-1 SPST Open High None ALL- CONTROLS (Ammonia-Compatible) P70AA-5 SPST Open Low 20 in. Hg to 100 P70CA-4 SPST Open High ( 68 to 690) Minimum 7 (48) Maximum 50 (345) 1/4 i n. SS Female NPT 325 psig (2239 kpa) 100 psig (690 kpa) None 1038

VALVES AND VALVE ACCESSORIES JOHNSON CONTROLS V46 SERIES ACTUATED WATER REGULATING VALVE The V46 is a pressure actuated, modulating valve that is suitable for use either on closed or open systems. Direct acting valves open on pressure increase. This type of valve is primarily used to regulate the flow of water or glycol to a water cooled condenser on a refrigeration system. Reverse acting valves open on pressure decrease and are generally used in parallel with a direct-acting valve or for bypass operation. FEATURES no close fitting or sliding parts in water passages minimizes chatter or water hammer free movement of all parts provides smooth pressure modulation refrigerant adjustment is not affected by water pressure withstands high hydraulic shock without damage range spring does not come in contact with cooling water easy manual flushing, if required 3/8, 1/2, and 3/4-in. valves may be disassembled and reassembled without detaching from the refrigeration system or without pumping down Modulate flow of water or glycol to a water cooled condenser on a refrigeration system. Examples include: Ice machines computer room air conditioning units ice cream machines refrigeration cases P4409 SPECIFICATIONS V46 SERIES ACTUATED WATER REGULATING VALVES Maximum Water Temperature 170 F (77 C) Valve Commercial: 3/8 to 3/4-in. cast brass, 1 in. and larger cast iron with a special finish Body Navy and Maritime: Cast naval bronze with monel interior parts SPECIFICATION REFRIGERANT OPENING POINT * V46A B, C, D MODULATING START POINT* V46N MAXIMUM PERMISSIBLE Water Refrigerant Static B Across Valve Non-Corrosive Refrigerants (R-12, R-22, R-134a, R-502, R-404a, R-507) 90 to 280 (621 to 1931) All Range Valve 70 to 260 320 (2206) 40 to 100 (276 to 690)** (483 to 1793) 150 All Range with High Overpressure 60 PST 370 (2551) (1034) 70 to 300 3/8 in. Extended All Range 440 (3034) (483 to 2068) Valves 2 in. or Larger R-12, R-134a 70 to 170 100 to 200 150 230 (1586) 2 and 2-1/2-in. Low Range (483 to 1172) (690 to 1931) (1034) 60 PST R-22, R-502, R-404a, R-507 160 to 260 180 to 280 320 (2206) 2 and 2-1/2 in. High Range (1103 to 1793) (1241 to 1931) Other Refrigerants 100 to 200 150 Ammonia R717 130 to 230 (896 to 1586) 60 PST 320 (2206) (690 to 1379) (1034) *V46A, B, C, D direct acting valve ranges indicate the valve opening point; V46N reverse acting valve ranges indicate the valve closing point. **For heat pump applications (3/8-in. through 1-1/2-in. sizes only) used in parallel with direct-acting valve. 1039

VALVES AND VALVE ACCESSORIES JOHNSON CONTROLS V46 SERIES ACTUATED WATER REGULATING VALVE (cont) PIPE SIZE (in.) INLET AND OUTLET OPENING POINT *Replacement element supplied with 1/4-in. male SAE connector. Order SEC37A capillary kit with 2 flare nuts separately, if needed. **Low water flow valve 2.5 GPM max. Maximum opening point of 70 to 300 psi (483 to 2068 kpa), maximum permissible pressure of 440 psi (3034 kpa). NOTES: 1. Use only on valves specified. 2. Standard capillary length of Style 45 and Style 34 elements is 30 inches. ELEMENT STYLE SEAT REPAIR KIT REPLACEMENT POWER ELEMENTS COMMERCIAL TYPE, STANDARD FLOW NON-CORROSIVE REFRIGERANTS (R) V46AA-1C 3/8 NPT STT14A-600R SEP91A-600R and SEC37A-601R* V46AB-1C 1/2 NPT STT15A-602R SEP91A-602R and SEC37A-602R* V46AC-1C 3/4 NPT Threaded 30 in. Capillary STT16A-601R SEP91A-601R and SEC37A-602R* 1/4-in. Flare Nut V46AD-1C 1NPT (Style 45) STT17A-609R SEP91A-603R and SEC37A-600R* V46AE-1C 1-1/4 NPT STT17A-610R V46AJ-2C 1/2 70 to 250 (483 to 1793) STT15A-602R SEP77A-605R V46EK-2C 3/4 STT16A-601R SEP127A-600R Union 30-in. Capillary V46AL-2C 1 1/4in. Flare Nut STT17A-609R (Style 46) SEP107A-602R V46AM-2C 1-1/4 STT17A-610R 30-in. Capillary V46AR-1C 1-1/2 1/4-in. Flare Nut (Style 45) STT17A-610R SEP91A-603R and SEC37A-600R* V46AS-1C 2 4-Hole 70 to 170 (483 to 1172) ASME Flange 1/4-in. Male Flare SEP81A-602R STT18A-600R V46AS-2C 2 160 to 250 (1103 to 1793) Fitting (Style 5) SEP81A-601R V46AT-1C 2-1/2 70 to 170 (483 to 1172) SEP81A-602R (Note 1) STT81A-601R V46AT-2C 2-1/2 160 to 260 (1103 to 1793) SEP81A-601R COMMERCIAL TYPE, LOW FLOW NON-CORROSIVE REFRIGERANTS (R)** 30-in. Capillary V46DA-2C 3/8 NPT Threaded 70 to 260 (483 to 1793) 1/4-in. Flare Nut (Style 45) STT14A-630R SEP91A-600R and SEC37A-601R COMMERCIAL TYPE AMMONIA (R) V46AC-8C 3/4 NPT STT16A-601R SEP70A-601R V46AD-4C 1NPT Threaded STT17A-609R 46AE-4C 1-1/4 NPT 1/4-in. Female NPT STT17A-610R SEP70A-604R 100 to 200 (690 to 1379) V46AR-2C 1-1/2 (Style 15) STT18A-610R V46AS-3C 2 4Hole ASME Flange STT18A-600R V46AT-3C 2-1/2 STT18A-601R SEP70A-605R MARITIME TYPE NON-CORROSIVE REFRIGERANTS (R) V46BA-2C 3/8 NPT STT14A-601R SEP13A-602R V46BB-2C 1/2 NPT STT15A-603R SEP13A-600R V46BC-2C 3/4 NPT Threaded 70 to 260 (483 to 1793) 30-in. Capillary with STT17A-613R SEP13A-603R V46BD-2C 1NPT Sweat Connection STT17A-611R V46VE-2C 1-1/4 NPT (Style 34) STT17A-612R SEP50A-600R V46BS-4C 2 4Hole V46BT-4C 2-1/2 ASME Flange 160to260(1103to1793) STT18A-602R SEP50A-601R NAVSEA CERTIFIED NON-CORROSIVE REFRIGERANTS (R) V46CJ-2C 1/2 Sweat Connector STT15A-603R SEP13A-600R V46CN-2C 3/4 STT17A-613R SEP13A-603R V46CP-2C 1 4Hole Navy Flange STT17A-611R V46CQ-2C 1-1/4 70 to 260 (483 to 1793) V46BR-2C 1-1/2 4Hole ASME Flange STT17A-612R SEP50A-600R V46CR-2C 1-1/2 6HoleNavy 30-in. Capillary with Flange Sweat Connection V46BS-3C 2 4Hole ASME Flange 70 to 170 (483 to 1172) (Style 34) V46CS-3C 2 6Hole V46CS-4C 2 Navy Flange 160 to 260 (1103 to 1793) V46BT-3C 2-1/2 4Hole ASME Flange 70 to 170 (483 to 1172) V46CT-3C 2-1/2 6Hole V46CT-4C 2-1/2 Navy Flange 150 to 260 (1103 to 1793) STT18A-602R SEP50A-601R 1040

VALVES AND VALVE ACCESSORIES JOHNSON V46N SERIES REVERSE ACTING VALVE The V46N Series are reverse acting pressure actuated modulating valves used on either open or closed loop coolant systems. Reverse acting valves open on a refrigerant pressure decrease. They are generally used in parallel with a direct acting valve for heat pump applications or for bypass operation. bypass systems water cooled heat pumps in parallel with direct acting valve PIPE SIZE (in.) INLET AND OUTLET OPENING POINT ELEMENT STYLE SEAT REPAIR KIT REPLACEMENT POWER ELEMENTS COMMERCIAL TYPE, STANDARD FLOW NON-CORROSIVE REFRIGERANTS (R) V46NA-1C 3/8 NPT STT14A-600R SEP91A-600R & SEC37A-601R* 90 to 280 (621 to 1931) V46NB-1C 1/2 NPT STT15A-602R SEP91A-602R & SEC37A-602R* V46NB-2C 40 to 100** (276 too 690) 30-in. Capillary with V46NC-1C 90 to 280 (621 to 1931) 1/4-in. Flare Nut 3/4 NPT STT16A-601R SEP91A-601R & SEC37A-602R* V46NC-2C Threaded 40 to 100** (276 to 690) + Schrader Valve V46ND-1C 90 to 280 (621 to 1931) Depressor 1NPT (Style 45) STT17A-609R V46ND-2C 40 to 100** (276 to 690) SEP91A-603R & SEC37A-600R* V46NE-1C 90 to 280 (621 to 1931) 1-1/4 NPT STT17A-610R V46NE-2C 40 to 100** (276 to 690) *Maximum bellows overpressure is 320 psig (2206 kpa). Replacement element provided with 1/4-in. male SAE connector. Order SEC73A capillary kit with 2 flare nuts, separately if needed. Use only on valves specified. **For heat pump applications. JOHNSON CONTROLS V47 SERIES TEMPERATURE ACTUATED MODULATING VALVE The V47 is a temperature actuated modulating valve that regulates the flow of water or glycol to maintain a desired temperature. Three temperature ranges for each valve size are available. Many valves come with a removable bypass plug that can be replaced by the bypass orifice provided separately with each valve. Valve action is open on temperature increase. For open on temperature decrease models, contact Application Engineering. ACCESSORIES (Companion Flanges and Gasket) KIT NUMBER KIT14A-612 KIT14A-613 KIT14A-614 WATER VALVE SIZE (in.) 1-1/2 in. 2in. 2-1/2 in. SPECIFICATIONS V47 SERIES TEMPERATURE ACTUATED MODULATING VALVES Maximum Bulb Temperature 20 F ( 6.7 C) above temperature range Maximum Water Temperature 170 F (77 C) Maximum Supply Water Pressure 150 psig (1034 kpa) Capillary Length* 6 ft (1.83 m) Nylon Armor Temperature Bulb Style 4** (pictured) (1/2 in. NPT closed tank immersion) *V47AC-8 Capillary Length 4 ft. **V47AB-2 Temperature Bulb Style 1 (no 1/2-in. NPT male fitting). METRIC CONVERSION CHART F C 75 to 115 24 to 46 75 to 135 24 to 57 115 to 160 46 to 71 115 to 180 46 to 82 160 to 205 71 to 96 160 to 230 71 to 110 1041

VALVES AND VALVE ACCESSORIES JOHNSON CONTROLS V47 SERIES TEMPERATURE ACTUATED MODULATING VALVE (cont) PIPE SIZE (in.) (Opening Point) F *Style 1 bulb (does not include 1/2-in. male NPT fitting). **ASME Flange. BULB SIZE (in.) (Dia Length) STD BYPASS ORIFICE DIA (in.) SEAT REPAIR KIT REPLACEMENT SENSING ELEMENT BULB WELL NUMBER (Order Separately) V47AA-1C 3/8 115 to 180 Heating 11/16 x 3-1/4 0.062 STT14A-600R SET29A-622R WEL18A-602R V47AA-2C 3/8 160 to 230 Heating 11/16 x 3-1/4 0.062 STT14A-600R SET29A-623R WEL18A-602R V47AA-3C 3/8 75 to 135 Cross Ambient 11/16 x 6 0.062 STT14A-600R SET29A-601R WEL17A-601R V47AB-2C 1/2 75 to 135 Cross Ambient 11/16 x 10* STT15A-602R SET29A-602R WEL17A-600R V47AB-3C 1/2 115 to 180 Heating 11/16 x 3-1/4 0.062 STT15A-602R SET29A-624R WEL18A-602R V47AB-4C 1/2 160 to 230 Heating 11/16 x 3-1/4 0.062 STT15A-602R SET29A-625R WEL18A-602R V47AB-5C 1/2 75 to 135 Cross Ambient 11/16 x 10 0.062 STT15A-602R SET29A-602R WEL17A-600R V47AC-3C 3/4 115 to 180 Heating 11/16 x 3-1/4 0.062 STT16A-601R SET29A-627R WEL18A-602R V47AC4C 3/4 160 to 230 Heating 11/16 x 3-1/4 0.062 STT16A-601R SET29A-627R WEL18A-602R V47AC-6C 3/4 75 to 135 Cross Ambient 11/16 x 10 0.062 STT16A-601R SET29A-604R WEL17A-600R V47AC-8C 3/4** 75 to 135 Heating 11/16 x 3-1/4 STT16A-601R SET98A-621R WEL18A-602R V47AD-1C 1 75 to 135 Cross Ambient 11/16 x 16-1/4 0.093 STT17A-609R SET29A-605R V47AD-2C 1 115 to 180 Heating 11/16 x 6 0.093 STT17A-609R SET29A-629R WEL17A-601R V47AD-3C 1 160 to 230 Heating 11/16 x 6 0.093 STT17A-609R SET29A-630R WEL17A-601R V47AE-1C 1-1/4 75 to 135 Cross Ambient 11/16 x 16-1/4 0.093 STT17A-610R SET29A-605R V47AE-2C 1-1/4 115 to 180 Heating 11/16 x 6 0.093 STT17A-610R SET29A-629R WEL17A-601R V47AE-3C 1-1/4 160 to 230 Heating 11/16 x 6 0.093 STT17A-610R SET29A-630R WEL17A-601R V47AR-1 1-1/2** 75 to 135 Cross Ambient 11/16 x 16-1/4 0.093 STT17A-610R SET29A-605R V47AR-2 1-1/2** 115 to 180 Heating 11/16 x 6 0.093 STT17A-610R SET29A-629R WEL17A-601R V47AR-3 1-1/2** 160 to 230 Heating 11/16 x 6 0.093 STT17A-610R SET29A-630R WEL17A-601R V47AS-1 2** 115 to 160 Heating 11/16 x 10 0.125 STT18A-600R SET29A-632R WEL17A-600R V47AS-2 2** 160 to 205 Heating 11/16 x 10 0.125 STT18A-600R SET19A-633R WEL17A-600R V47AS-3 2** 75 to 115 Cross Ambient 11/16 x 43 0.125 STT18A-600R SET29A-606R V47AT-1 2-1/2** 15 to 160 Heating 11/16 x 10 0.125 STT18A-601R SET29A-632R WEL17A-600R V47AT-2 2-1/2** 160 to 205 Heating 11/16 x 10 0.125 STT18A-601R SET29A-633R WEL17A-600R V47AT-3 2-1/2** 75 to 115 Cross Ambient 11/16 x 43 0.125 STT18A-601R SET29A-606R 1042

VALVES AND VALVE ACCESSORIES JOHNSON CONTROLS V47N SERIES REVERSE ACTING VALVE The V47N Series are reverse-acting, temperature-actuated, modulating valves that regulate the flow of water or glycol to maintain a desired temperature. Reverse-acting valves open on a drop in temperature. They are generally used in parallel with direct-acting valves for hand pump applications or for bypass operation. bypass systems water-cooled heat pumps in parallel with a direct-acting valve PIPE SIZE & CONNECTOR OPENING POINT FACTORY SET OPENING POINT BULB SIZE (in.) STANDARD BYPASS ORIFICE V47NA-2C 85 to 155 F 105 F 11/16 x 3-1/4 3/8-in. Screw V47NA-8C 215 to 265 F 240 F 1-1/4 x 5 0.04 in. V47NB-1C 1/2-9n. Screw 85 to 155 F 105 F 11/16 x 3-1/4 V47NC-1C 3/4-in. Screw V47NR-1C 1-1/2-in. Flange 45 to 85 F 55 F 11/16 x 16-1/4 REPAIR PARTS AND ACCESSORIES PARTS FOR: Seat Repair Kit Replacement Sensing Element Bulb Well Number (Order Separately) WEL18A-601R (Monel) V47NA-2C STT14A-600R V47NA-8C V47NB-1C STT15A-602R WEL18A-601R (Monel) WEL18A-602R (Brass) V47NC-1C STT18A-601R V47NR-1C STT17A-610R SET29A-605R JOHNSON CONTROLS V48 SERIES THREE-WAY WATER REGULATING VALVE V48 Series valves are designed specifically for condensing units cooled either by atmospheric or forced draft cooling towers. V48 Series valves are used on single or multiple condenser hook-ups to the tower to provide the most economical and efficient use of the tower. REFRIGERANT (R) FACTORY SETTINGS Opening Press. Port 1 to Port 2 Closing Press. Port 1 to Port 3 R-12 95 (655) 120 (896) R-22 165 (1138) 215 (1482) (Non-Corrosive Refrigerants) PIPE SIZE (in.) OPENING POINT OF NORMALLY CLOSED SIDE ( ELEMENT STYLE WATER SUPPLY INLET AND OUTLET PORTS MAX BELLOWS OVER SEAT REPAIR KIT REPLACEMENT SENSING ELEMENT V48AB-1C 1/2 85 to 110 (586 to 758) 230 psig (1586 kpa) SEP91A-602R STT15A-605R V48AB-2C 1/2 145 to 190 (1000 to 1310) 320 psig (2206 kpa) SEC37A-602R* V48AC-1C 3/4 85 to 110 (586 to 758) 230 psig (1586 kpa) SEP91A-601R 30-in. Capillary STT16A-604R V48AC-2C 3/4 145 to 190 (1000 to 1310) 320 psig (2206 kpa) SEC37A-602R* with 1/4-in. Flare V48AD-1C 1 85 to 110 (586 to 758) Nut (Style 45) 230 psig (1586 kpa) Threaded STT17A-616R V48AD-2C 1 145 to 190 (1000 to 1310) 320 psig (2206 kpa) SEP91A-603R V48AE-1C 1-1/4 85 to 110 (586 to 758) 230 psig (1586 kpa) SEC37A-600R* STT17A-617R V48AE-2C 1-1/4 145 to 190 (1000 to 1310) 150 psig 320 psig (2206 kpa) V48AF-1C 1-1/2 85 to 110 (586 to 758) 1/4-in. Male Flare (1034 kpa) 230 psig (1586 kpa) SEP81A-602R STT17A-604R V48AF-2C 1-1/2 Fitting (Style 5) 320 psig (2206 kpa) SEP81A-601R 30-in. Capillary V48AJ-2C 1/2 with 1/4-in. Flare 320 psig (2206 kpa) STT15A-605R SEP77A-605R 145 to 190 (1000 to 1310) Nut (Style 45) Union V48EK-2C 3/4 30-in. Capillary 370 psig (2551 kpa) STT16A-604R SEP127A-600R V48AL-2C 1 with 1/4-in. Flare STT17A-616R Nut (Style 46) 320 psig (2206 kpa) SEP107A-602R V48AM-2C 1-1/4 STT17A-617R *Replacement element supplied with 1/4-in. male SAE connector. Order SEC37A capillary kit with two flare nuts separately if needed. Use only on valves specified. NOTE: Standard capillary length on Style 45 and Style 34 elements is 30 inches. 1043

LIQUID LEVEL AND FLOW CONTROLS JOHNSON CONTROLS F61 SERIES FLOW SWITCH (Standard Flow Rate SPDT) The F61 Series Flow Switches are Single-Pole, Double-Throw (SPDT) flow switches used on fluid lines carrying water, ethylene glycol, or other fluids not classified as hazardous. They can be wired to energize one device and de-energize another device powered from the same source when fluid flow either exceeds or drops below the set flow rate. The F61MG type flow switches are used for low-energy loads to operate small relays, solenoid valves, and electronic control circuits. These flow switches have gold-plated contacts for improved electrical performance in low voltage, low current circuits. FEATURES stainless steel paddle has three segments for use in pipes from 1 in. to 3in.(25mmto75mm)diameter paddle segments can be removed or trimmed as needed F61KB-11 and F61MB-1 include a 6-in. (152 mm) paddle for pipes 4 in. to 6 in. (102 mm to 152 mm) gold-plated contacts on F61MG-1 reduce intermittent contact problems in low-voltage and low-current circuits : use on lines carrying water or ethylene glycol not for use with hazardous fluids or in hazardous atmospheres TO ORDER: Specify the part number from the following selection chart. ENCLOSURE BELLOWS PADDLE F61KB-11 NEMA 1 Phosphor Bronze Stainless Steel; 3-piece Paddle (3 in., 2 in., and 1 in. Segments) Installed; 6 in. Paddle Supplied Uninstalled F61LB-1 NEMA 1 Phosphor Bronze Stainless Steel; 3-piece Paddle (3 in., 2 in. and 1 in. Segments) Installed F61MB-1 NEMA 3R Phosphor Bronze Stainless Steel; 3-piece Paddle (3 in., 2 in., and 1 in. Segments) Installed; 6 in. Paddle Supplied Uninstalled F61MB-5 NEMA 3R Stainless Steel Stainless Steel; 3-piece Paddle (3 in., 2 in., and 1 in. Segments) Installed; 6 in. Paddle Supplied Uninstalled F61MB-1* NAME 3R Phosphor Bronze Stainless Steel; 3-piece Paddle (3 in., 2 in., and 1 in. Segments) Installed; 6 in. Paddle Supplied Uninstalled *Gold-Plated Contacts. 1044

LIQUID LEVEL AND FLOW CONTROLS JOHNSON CONTROLS F59 SERIES SUMP PUMP SWITCH The F59 Series controls are designed to start an electric motor on liquid level rise and stop the motor on liquid level drop. The control cuts in when upper weight is submerged approximately halfway, and cuts out when lower weight is approximately half-exposed. Each switch includes 36 in. cable and (2) two weights. FEATURES F59D-5 is equipped with a power cord and a piggyback style plug. The male prongs plug into the wall outlet, and the sump pump cord plugs into the female end of the plug. On/Off control of sump pumps. CONTACT MOUNTING ACTION ADJUSTER!F59A-1 DPST External mounting bracket Drop cord wiring!f59a-2 DPST External mounting includes universal mounting bracket and 24 in. strap for quick, easy mounting on the motor, on the pedestal or on the discharge pipe. Drop cord wiring F59D-5 SPST External mounting includes 8 ft power cord with 3-prong clamp for mounting on the pedestal piggyback plug or on the discharge pipe. F59H-1 DPST External mounting bracket Conduit Wiring 7/8-in. conduit openings in case.!universal Replacement. 1045

LIQUID LEVEL AND FLOW CONTROLS JOHNSON CONTROLS F61 SERIES FLOW SWITCH (Low Flow Rate SPDT) For use on liquid lines using water, ethylene glycol solutions, or other liquids not injurious to the brass and phosphor bronze parts. The SPDT contact switch is activated by a low flow rate; however, it has a large flow capacity with a minimum pressure drop. Typical applications include: water purification and treatment systems booster pumps fast shutdown on high input boilers to guard against circulation failure cooling systems for electronic tubes, bearings and compressors INLET AND OUTLET SIZE FEMALE NPT ENCLOSURE NEMA TYPE R to Y Closes Flow Increase F61KD-3C 1/2 x 1/2 in. (13 x 13 mm) 1 Minimum 0.6 (2.27) F61KD-4C 3/4 x 3/4 in. (19 x 19 mm) 1 F61KD-8C 3/4 x 3/4 in. (19 x 19 mm) 1 F61MD-1C 1/2 x 1/2 in. (13 x 13 mm) 3R F61MD-2C 3/4 x 3/4 in. (19 x 19 mm) 3R ADJUSTMENT GPM (L/Min) Maximum 1.1 (4.17) Minimum 8.5 (32.2) Maximum 9.0 (34.1) Minimum 0.6 (2.27) Maximum 1.1 (4.17) Minimum 0.6 (2.27) Maximum 1.1 (4.17) RtoYOpens Flow Decrease Minimum 0.3 (1.14) Maximum 0.9 (3.4) Minimum 4.5 (17.1) Maximum 6.3 (23.9) Minimum 0.3 (1.14) Maximum 0.9 (3.4) Minimum 0.3 (1.14) Maximum 0.9 (3.4) MAXIMUM LIQUID TEMP 250 F (121 C) MINIMUM LIQUID TEMP 32 F (0 C) 20 F ( 29 C) MAXIMUM LIQUID 150 psig (1034 kpa) JOHNSON CONTROLS P62 SERIES AIRFLOW SWITCH (SPDT Contact Unit) This control detects airflow or the absence of airflow in ducts, responding only to the velocity of air movement. The one-piece stainless steel paddle can be trimmed, if necessary. The control is supplied with mounting plate gasket. The range adjusting screw permits field adjustment of flow rate setting. F62AA-8* F62AA-9 PADDLE SIZE (in.) 2-1/8 in. x 6-7/8 in. 3-1/8 in. x 6-7/8 in. DIMENSION 10-3/8 in. H (including paddle), 4 in. W, 2-13/16 in. D 10-3/8 in. H (including paddle), 4 in. W, 2-13/16 in. D MAX AMBIENT TEMP 100 (40) 100 (40) MAX. AIR VELOCITY 2000 FPM (10 m/sec.) 2000 FPM (10 m/sec.) *Replaces McDonnell Miller AF-2. 1046

LIQUID LEVEL AND FLOW CONTROLS JOHNSON CONTROLS F63 SERIES LIQUID LEVEL FLOAT SWITCH (For Closed Tanks) The F63 can be wired to close one circuit and open another circuit when liquid level rises above or falls below the required level. The F63AC-1 has a NEMA 1 general purpose enclosure. The F63BF-1 has a NEMA 3R raintight enclosure. Not for use with hazardous fluids or in hazardous atmosphere. FEATURES SPDT snap-acting switch rugged steel enclosure (For Closed Tanks) SWITCH ACTION *Or Ambient Dew Point. **Or Liquid Freezing Point. ELECTRICAL RATINGS TYPE OF ENCLOSURE F63AC-1 SPDT General Purpose NEMA 1 F63BF-1 SPDT Vaportight/ Raintight NEMA 3R LIQUID TEMPERATURE MAX AMBIENT TEMP Max Min 250 32 (121) (0)* 180 20 (40) ( 29)** MAX LIQUID 100 (690) MOTOR RATINGS 120 VAC 208 VAC 240 VAC 277 VAC Horsepower 1 1 1 AC Full Load Amp 16.0 8.8 8.0 AC Locked Rotor Amps 96.0 52.8 48.0 Non-Inductive or Resistance Load Amp 16 16 16 16 Pilot Duty 125 VA, 24/277 VAC JOHNSON CONTROLS F92 SERIES AIR VOLUME CONTROL (For Shallow Wells) Shallow well air volume control prevents water logged or air bound tanks by maintaining proper air volume. FEATURES internal parts are constructed of brass to minimize corrosion high impact plastic body is resistant to mechanical damage and corrosion air volume control for shallow well tanks (For Shallow Wells) F92B-1 F92B-2 F92B-9 GAUGE TAPPING 1/4 in. Tap for Gauge 0.016 in. Brass Orifice 1/4 in. Tap for Gauge 1/4 in. Tap for Gauge COPPER TUBING AND CONNECTORS Flat Flare Fitting for 3/16 in. tubing on all air volume controls See Accessories Table for optional tubing kits. Kit No. 190-820 Included with Control TANK CONNECTOR 1-1/4 in. (32 mm) Male NPT SUPPLY TANK 80 lbs (552 kpa) Max Pressure Min Diameter 9 in. (229 mm) 1047

CONTROLS JOHNSON CONTROLS P28 SERIES LUBE OIL CUTOUT CONTROL (With Time Delay) The P28 series provides dependable shutdown on pressure of lubricated refrigeration compressors by sensing low lube oil pressure. A built-in time delay switch, accurately compensated for ambient temperature, allows for pressure pick up on start and avoids nuisance shutdowns on pressure drops of short duration during the running cycle. Semi-hermetic compressors The P28 control measures pressure available to circulate oil through the lubrication system. (Net oil pressure is the difference between oil gauge and crankcase pressure.) SPECIFICATIONS maximum bellows pressure is 180 psig (2241 kpa) TIME DELAY *Switch differential approximately 5 psi (34 kpa). Time delay relay energizes @ 9 psi (61 kpa) pressure difference, de-energized @ 14 psi (97 kpa) difference. Replaces Ranco P30-3701. **Non-corrosive refrigerants include R-12, R-22, R-134a, R-500, R-502 (R). Replaces Ranco P30-3601. ***Replaces Ranco P30-3801.!Universal Replacement. ELECTRICAL RATINGS PILOT DUTY TIME DELAY HEATER CIRCUIT VAC TYPE OF RESET * REFRIGERANT (R) CONNECTION! P28AA-1C 90 sec!p28aa-2c 60 sec 36 in. Cap. with Non-Corrosive** P28AA-17C*** 120 sec 1/4 in. Flare Nut P28AA-18C 45 sec Manual P28A-1C 90 sec 120/240 8to70 Ammonia 1/4 in. Female NPT 90 sec (55 to 483) P28DA-1C with Runlight and Alarm Terminals 36 in. Cap. with Non-Corrosive** 1/4 in. Flare Nut P28GA-2C 90 sec Automatic P28NA-5C 120 sec 24 VAC or VDC Manual TIME DELAY HEATER CIRCUIT PILOT CIRCUIT ALARM CIRCUIT (Must be same voltage as pilot circuit) 120/240 VAC 750 VA, 120/240 VAC 125 VA, 120/240 VAC 24 VAC or VDC 125 VA, 24 VAC 57.5 VA, 24 VDC 125 VA, 24 VAC 57.5 VA, 24 VDC P28DA-1 CONTACT RATING 2 to 1: 2 to 3 (Must be same voltage as time delay circuit) Crankcase Heater: Term 2 to 1 Runlight: Term 2 to 3 10 amp 120 VAC, 5 amp 240 VAC 10W 1048

CONTROLS JOHNSON CONTROLS 32 SERIES SENSITIVE SWITCH This differential pressure switch is used to sense airflow in ducts. airflow proving with electric duct heaters, humidifiers, and other equipment. maximum airflow control for variable volume systems reheat duct powered systems clogged filter detection detection of icing of air conditioning coils and initiation of defrost cycle ACCESSORIES FTG18A-600R Remote Mounting Kit: 4 in. flanged sensing tube, two barbed fittings, two No. 10 screws, and a gasket. ELECTRICAL RATINGS MOTOR RATINGS VAC 120 208 240 Type P32AC (Standard Differential, 1/2 hp) AC Full Load Amp 9.8 5.65 4.9 AC Locked Rotor Amp 58.8 33.9 29.4 Non-Inductive or Resistive Load 15 amp 24 to 277 VAC Pilot Duty 125 VA, 24 VAC; 360 VA, 120 to 277 VAC MOTOR RATINGS VAC 120 208 240 Type P32AF (Close Differential, 1/4 hp) AC Full Load Amp 5.8 3.3 2.9 AC Locked Rotor Amps 34.9 19.8 17.4 Non-Inductive or Resistive Load 10 amp, 24 to 277 VAC Pilot Duty 125 VA, 24 VAC; 360 VA, 120 to 277 VAC P32AC-1C AMBIENT TEMPERATURE Min/Max CONNECTOR High Pressure connectors are metal 1/8 in. female NPT inside, 1/2 in. NPSM outside for mounting. MAXIMUM OVER * CONTACT ACTION in. WC (kpa) 0.15 to 12 (0.037 to 2.99) SENSITIVITY AT MIN. SET POINT in. WC (kpa) 0.07 (0.017) 0.04 (0.01) SET POINT SCALE PLATE L MOUNTING BRACKET BKT182R P32AC-2C 40 F ( 40 C) U BKT229-1R min. 1 SPDT Adjustable Yes 167 F (75 C) (6.895) 0.05 to 5 P32AF-1C max. Low Pressure L BKT182-1R (0.012 to 1.24) connectors are 0.025 molded, 1/8 in. (0.006) P32AF-2C female NPT U BKT229-1R *Maximum overpressure at either connection. Supplied with 1/4 in. compression fitting, 4 in. extension tube, two mounting screws, and O gasket (angle barbed fitting installed). 1049

CONTROLS JOHNSON CONTROLS P45 SERIES LUBE OIL CUTOUT CONTROL (With Time Delay) The P45 control provides dependable, low lube oil pressure protection for refrigeration compressors. The factory set pressure setting provides operation to the compressor manufacturer s specification. A built-in time delay relay, compensated for ambient temperature, allows for pressure pick-up on start and avoids nuisance shutdowns on short duration pressure losses during the running cycle. FEATURES universal mounting trip-free manual reset ambient compensated time delay semi-hermetic compressors The P45 control measures net oil pressure available to circulate oil through the lubrication system. (Net oil pressure is the difference between oil pump pressure and the crankcase pressure.) ELECTRICAL RATING PILOT DUTY TIME DELAY HEAT CIRCUIT PILOT DUTY 120/240 VAC 750 VA, 120/240 VAC TIME DELAY*! P45NCA-12C 120 sec. P145NCA-12C P145NCB-12C***! P45NCA-82C P145NCA-82C P145NCB-82C HEATER CIRCUIT VAC TYPE OF RESET Copeland Compressors MAXIMUM BELLOWS FACTORY SETTING 120/240 Manual 425 (2390) 9 (62)** Carlyle Compressors 45 sec. 120/240 Manual 425 (2390) 6.5 (45) CONNECTION 36 in. Cap. with 1/4 in. Flare Nut Style 5 36 in. Cap. with 1/4 in. Flare Nut Style 5 *Relay is not field-replaceable. Replaces Ranco P30-5826. **Switch differential is approximately 5 psi (34 kpa). Time delay relay energizes at 9 psi (61 kpa) pressure difference, de-energizes at 14 psi (97 kpa) difference. Replaces Ranco P30-5827. ***Replaces Ranco P30-5827 (includes alarm wire). Switch differential is approximately 4.5 psi (34 kpa). Time delay relay energizes at 6.5 psi (45 kpa) pressure difference, de-energizes at 11 psi 76 kpa) difference.!universal Replacement. 1050

CONTROLS JOHNSON CONTROLS P74 SERIES DIFFERENTIAL CONTROL Series P74 measures the pressure difference between two sources: supply lines and return lines. A change in differential pressure will reposition the switching mechanism to cause corrective action of the supplementary control equipment. differential pressure sensing on chillers or water-cooled condensers lube oil failure cutout for refrigeration compressors (same as the P28, but does not incorporate time delay) positioning M100 Series motor-actuated valves (P74JA-2) to prove pump operation SWITCH ACTION DIFFERENTIAL psi (kpa)* SWITCH DIFFERENTIAL CONNECTIONS FOR ALL NON-CORROSIVE LIQUIDS P74AA-1C SPST Closes on Decreases in Pressure Difference 8to70Adjustable 36 in. Cap. with 8to30Adjustable P74BA-1C SPST Opens on Decrease in Pressure Difference (55 to 483) 1/4 in. Flare Nut 2to26Adjustable 36 in. Cap. with P74EA-8C 3.5 Fixed (14 to 207) 1/4 in. Flare Nut SPDT (Snap Acting) P74FA-1C 1/4 in. Male Flare 8to60 1.5 Fixed P74FA-5C 1/4 in. FNPT (55 to 414) P74JA-2C SPDT (Floating) 2.5 Fixed 1/4 in. Male Flare BELLOWS MATERIAL Stainless Steel Brass *Maximum continuous pressure to low pressure bellows 180 psig (1241 kpa). Suitable for use as refrigeration pressure limiting controls. 1051

CONTROLS JOHNSON CONTROLS P128 AND P145 SERIES LUBE OIL CONTROLS The P128 and P145 Series controls provide dependable low pressure lube oil cut-out for pressure lubricated refrigeration compressors. The P128 Series offer adjustable range settings. The P128 and P145 controls feature a 1/4-in. male flare pressure connection which may be used with a refrigerant hose or cap tube such as SEC99 UltraCap. FEATURES ambient compensated time delay relay trip-free manual reset industry standard P128 is fully adjustable throughout its range P145 is factory set to compressor manufacturer s specifications Lube oil cutout on hermetic and semi-hermetic compressors used in commercial air conditioning and commercial and industrial refrigeration systems. TIME HEATER CIRCUIT TYPE OF DELAY VAC RESET - psi (kpa)! P128AA-1C* 90 sec 8to70(55to! P128AA-2C 60 sec 483)! P128AA-17C** 120 sec! P145NCA-12C 120/240 Manual Factory Set 9 (62)! P145NCA-82C*** 45 sec Factory Set 6.5 (45)! P145NCB-12C 120 sec Factory Set 9 (62)! P145NCB-82C 45 sec Factory Set 6.5 (45) *Replacement for P28AA-1-. Replaces Ranco P30-3701. Replacement for P28AA-2-. Replaces Ranco P30-3601. **Replacement for P28AA-17-. Replaces Ranco P30-3801. Replacement for P45NCA-12-. (Copeland Model). Replaces Ranco P30-5826. ***Replacement for P45NCA-82-. Copeland model with alarm circuit. ****Carlyle model with alarm circuit. NOTE: SEC99 UltraCap hose must be ordered separately.!universal Replacement. REFRIGERANT Non-Corrosive CONNECTION 1/4 in. Male Flared Conn. JOHNSON CONTROLS P12 SERIES DIFFERENTIAL CONTROLS The P12 Series Differential Pressure Controls are suitable for use with oil and/or non-corrosive refrigerants. The switch is actuated by a difference in pressure between the two sensing elements. The control is factory-set to open the switch (COM to 1) at a differential pressure of 18 psi (124 kpa) and close the switch (COM to 1) at a differential pressure of 12 psig (82 kpa). The control is not field-adjustable. This control may be connected to a P28 oil failure cutout control, with time delay, to give complete monitoring of lubrication on two refrigeration compressors driven by one motor. DIFFERENTIAL MAXIMUM ALLOWABLE ENCLOSURE FITTING COM to 1 Opens COM to 1 Closes, P12AA-3C 18 psi (124 kpa) 12 psi (821 kpa) 425 (2390) NEMA1 Enclosure 1/4 in. male SAE flare fitting 1052

CONTROLS JOHNSON CONTROLS P445 SERIES ELECTRONIC LUBE OIL CONTROL The P445 Series Electronic Lube Oil Control is designed for use on refrigeration compressors equipped with an oil pump that accepts a single-point differential pressure transducer. The P445 control senses net tube oil pressure and de-energizes the compressor if lube oil pressure falls below the manufacturer s recommendation for longer than the time delay. Front-mount LEDs indicate the status of the lubrication system and a user-selectable time delay can be set to minimize compressor short cycling. The R310A Current Sensing Switch is separately available for applications where the P445 control and the compressor are powered separately. FEATURES SPDT relay contacts for liquid line solenoid and alarm applications, improves performance of alarm indication, including circuits that use neon lights relay contact output for the compressor provides reliable, long-lasting operation built-in test circuit verifies proper control operation quickly without additional tools or equipment improved noise immunity exceeds requirements of UL 991 section 9 for transient overvoltage immunity and IEC 801-3 and IEC 8001-6 for electromagnetic current immunity, reducing the effect of noise caused by contacts or variable speed motor drives selection of anti-short cycle time delay on loss of power allows for choice of anti-short cycle strategy for a wide range of equipment requirements, possible elimination of short cycle timer user-friendly display panel continuously displays status of the compressor lubrication system size and wiring easily replaces many existing electromechanical and electronic lube oil controls P4413 Electronic Lube Oil Control, 120 Second Delay Before Lockout, Fixed Setpoint P445NCB-21C Pressure: 9 psi (62 kpa), 48 in. Cable, Includes Sensor (Copeland) Electronic Lube Oil Control, 120 Second Delay Before Lockout, Fixed Setpoint P445NCB-22C Pressure: 9 psi (62 kpa), 36 in. Cable, Includes Sensor (Copeland) Electronic Lube Oil Control, 90 Second Delay Before Lockout, Fixed Setpoint P445NCB-25C Pressure: 10 psi (62 kpa), 48 in. Cable, Includes Sensor (Tecumseh) Electronic Lube Oil Control, 120 Second Delay Before Lockout, Fixed Setpoint P445NCB-82C Pressure: 6.5 psi (44.8 kpa), 36 in. Cable, Includes Sensor (Carlyle) SPECIFICATIONS Power Requirements Fixed SetPoint Pressure Lube Oil Time Delay (Factory Settings) Anti-short Cycling Timer Type of Refrigerant Maximum Electrical Rating P445 Series Electronic Lube Oil Control 120 or 240 VAC, 50/60 Hz +10%, 15%; power consumption; 3 VA P445NCB-82 6.5 lb (44.8 kpa) P445NCB-21 9 lb (62 kpa) P445NCB-22 9 lb (62 kpa) P445NCB-25 10 lb (69 kpa) P445NCB-25 90 ±12 seconds P445NCB-21 120 ± 15 seconds P445NCB-22 120 ± 15 seconds P445NCB-82 120 ± 15 seconds Four selectable positions; 0, 35, 65, and 100 seconds (nominal times) Noncorrosive refrigerants only Isolated relay output to compressor contactor (M-1 and M-2) Pilot Duty 375 VA at 120 VAC, 750 VA at 240 VAC 1053

ELECTRONIC FAN SPEED CONTROLS JOHNSON CONTROLS P66 SERIES ELECTRONIC FAN SPEED CONTROL The P66 is a pressure-actuated electronic motor speed controller. By directly sensing pressure, this device electronically varies the speed of a fan motor. This control can be used with a single-phase permanent split capacitor and shaded pole motors that are approved by the motor and equipment manufacturer for speed control applications. To prevent overheating, use a ball bearing motor with a service factor of at least 1.25. P4407 OPERATING (Factory Setting) EFFECTIVE THROTTLING (Fixed) (Adjustable) MAXIMUM OVER CONTROL VOLTAGE START VOLTAGE %OFLINE CAPILLARY LENGTH (in.) P66AAB High-Pressure Models P66AAB-1C 190-250 (1310-1724) 10 60 P66AAB-3C 180-240 (1241-1655) 16 60 P66AAB-6C 170-230 (1172-1586) 16 60 P66AAB-9C 170-230 (1172-1586) 40 60 P66AAB-10C 190-250 (1310-1724) 16 120 P66AAB-11C 140-200 (965-1379) 60 (414) 140-350 24 VAC, 1 VA, 450 (3103) (965-2413) Class 2 16 60 P66AAB-12C 220-280 (1517-1931) 16 120 P66AAB-14C 220-280 (1517-1931) 40 120 P66AAB-15C 190-250 (1310-1724) 40 60 P66AAB-25C 180-240 (1241-1655) 10 120 P66AAB-26C 220-280 (1517-1931) 40 60 P66AAB Low Pressure Models P66AAB-4C 135-165 (931-1138) 80-200 10 P66AAB-7C 85-115 (586-793) 80-200 24 VAC, 1 VA, 16 30 (207) 450 (3103) P66AAB-13C 60-90 (414-621) 60-180 Class 2 16 60 P66AAB-19C 115-145 (9793-998) 80-200 40 P66ABB All General Application Models P66ABB-21C 220-280 (1517-1931) 140-350 24 VAC, 1 VA 120 60 (414) 450 (3103) 16 P66ABB-24C 190-250 (1172-1724) (965-2413) Class 2 60 1054