EL1000 Mach 3 Tech Sheet Balboa Instruments

Similar documents
GL2000 Hot Sheet. System PN 53258_03 (Mach 2.1) Balboa Instruments. System Model # GL2-GL2000-RCA-3.0k Universal AC Service Option

ML550, 551, 554 Panel Operation

BP501G3 Tech Sheet. Part Number: Incoloy Incoloy Titanium. Custom Box Overlay Box Overlay Part Number N/A

BP2100G1 Tech Sheet. Customer: Balboa Water Group

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

spatouch Menued Control Panels

Equipment Booklet. Sousou SPA. for

TP800 and TP900 Series Control Panels

2017 Spa Touch Control Panel with 2000, 2100, 501, 6013 controllers (Spa Owner s Manual insert)

spatouch Icon Driven Control Panels

HT-2 / 9600 Series Control Contents

DistributedBy. 7215BermudaRoadLasVegas,NV89119 TolFree: Fax:

60 Hz. Balboa's BP Troubleshooting & Service Manual THIS MANUAL COVERS THE FOLLOWING: SPA CONTROL SYSTEMS BP500 BP2000G1 TP900, TP800, TP600, TP400

VS/GSSeries. Controls & Panels. Control systems. Your Single Source Solution. ML Panels For EL/GL Systems. Programmable Filtration

EL/GL Series - Mach 3 ML550 User Guide

User Guide. Balboa Water Group

TP600 and TP400 Control Panels

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

EL/GL Series - Mach 3 MLM990S User Guide

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

MSPA-MP METAPACK SERVICE MANUAL. Visual step-by-step guide to easily identify & correct technical problems! Gecko Electronics Inc.

TP600 and TP400 Control Panels

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

EL/GL Series - Mach 3 ML900 User Guide

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

OnCommand. Automation. Operation Manual ONCOM ONCOM-ACT ONCOM-RC ONCOM-ACT-RC ONCOM-POD2 ONCOM-ACT-POD2

Spas with 2 or 3 Pumps

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

D A R A - 4. Data Aire Relay Auto-Changeover

User Manual. Dryer Controller M720

Dryer Controller M720

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

FPC-02 Series. Installation and Operating manual

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Schneider Electric Erie T155 Series

20 Light Remote Annunciator

INSTRUCTIONS FOR THD-U SERIES HOT AIR MATERIAL DRYERS

Smart Temp. Model

50 Hz. Balboa's BP Troubleshooting & Service Manual THIS MANUAL COVERS THE FOLLOWING: SPA CONTROL SYSTEMS BP600 BP2100G1 TP900, TP800, TP600, TP400

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

GENERATOR SELF-TEST VERIFIER (GSV300) INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Pioneer-R16 Gas Monitor Operator s Manual

Model: Touch-RS. 1 Touch-RS

DIAGNOSTIC GUIDE DIAGNOSTIC TEST DISPLAY FAULT/ERROR CODES IMPORTANT. Activating the Diagnostic Test Mode. Before servicing, check the following:

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

TechBook. in.k300tm. Bright LCD screen Spa function icons Affordable. the essential spa keypad

Oakton TEMP 9500 Advanced Multiparameter Controller

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

Smart Temp. ApolloP/n Installation Manual. Version 1.0

WC Series Vended Washers Troubleshooting, and Fault Codes

SITC-15 Temperature Controller GITC-15 Temperature Controller Mainframe Operation Manual

OVEN INDUSTRIES, INC.

Installation Instructions

Product Manual SZ1009

INSTRUCTION MANUAL. Blue Whale Spa Ltd, 11 Glaisdale Drive East Nottingham, NG8 4GU

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

GTC15 Temperature Controller Operation Manual

REC-8R Environmental Control. Operation and Installation Manual

CLEARLY ADVANCED SPA SYSTEMS! OWNER'S MANUAL MC-MP-SBD SPA SYSTEMS INSTALLATION, INSTRUCTIONS & MORE! TAKING OVER THE WAVES!

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

SmarTemp Control fx 2.0

Installation and Operation Manual

This manual covers your new TidalFit

Table of contents. in.k200 keypad overview - introduction function description instructions Typical settings...

SAS6000UTK-7 UNIVERSAL THERMOSTAT

IMPORTANT SAFETY INSTRUCTIONS READ ENTIRE MANUAL BEFORE INSTALLING SPA. PLEASE SAVE THIS MANUAL. OWNER S MANUAL. 8 Button Controller & Pack

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

D3000. Installation and Operating Manual SAFETY D3000 SPECIFICATIONS PRODUCT DESCRIPTION

PARAGON Commercial Refrigeration Controls

INSTALLATIONN GUIDE & OPERATION MANUAL

Safety & Installation Instructions

Operator: Save these instructions for future use!

General Purpose IO Technical Manual

ALARM OUTPUT MODULE. Product #7736

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

EasyTronic III MANUAL SERVICE

Halton SAFE / 7.14 user guide and installation instructions

RE-PR3-E-27 3-Phase Panel Mount 27kW

EL-TSTAT-8820 Safety & Installation Instructions

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

MPT Electric Fire Pump Controller

Operator: Save these instructions for future use!

Transcription:

EL000 Mach Tech Sheet Balboa Instruments System PN 55068-04 System Model # EP-EL000M-DCAH Software Version # EPN # 8 Base PCBA PN 5487-04 PCB EL000 PN 95 Rev B or C HEX File 0004 Base Panels ML400 PN 5684 Template used: 4057-v_A.pdf 04/6/008.pdf 04/0/008 Page

System Revision History System PN EPN Date Requested By Changes Made 55068-0 0.6.006 Balboa Software update to v8 55068-0 n/a 07.0.007 Balboa Software update to v0 55068-04 8 04.0.008 Balboa Software update to v Page

Basic System Features and Functions Power Requirements 40VAC, 60Hz, 40A, Class A GFCI-protected service (Circuit Breaker rating = 50A max.) System Outputs Setup (As Manufactured) Additional Options Connects to Main Panel terminal J70 or J7 Connects to Remote terminal J0 Connects to terminal J9 Connects to A.V. terminal J W J J4 G J7 J70 J0 J9 MAIN PANELS AUX. PANELS J7 J5 K P LO ALRM J96 U4 J80 J69 J0 ADCM REMOTE J8 J J4 J8 K W9 A EXT TST AUX. F CFG SENS. A SENS. B VAC Page

Persistent Memory and Powering Up Any time you change DIP Switches or Software Configuration Settings that affect parameters the user can change (any filter settings, set temperature default, Celsius vs Fahrenheit, -hour vs 4-hour time, reminders suppression, etc), you must reset Persistent Memory for your DIP Switch or Software Configuration Settings changes to take effect. You should also reset Persistent Memory after loading a new file into a board (using the ESM, purchased seperately). To reset Persistent Memory: Power down. Set A ON (See illustration below). Power up. Wait until or is displayed on your panel. Note: If appears see section below. Set A OFF. (This can be done safely with power on if you use a nonconductive tool such as a pencil to push the switch back to the OFF position. Otherwise, power down before setting A OFF) Power up again (if you powered down in the previous step). For all other power ups, leave A OFF. About Persistent Memory and Time of Day Retention: This system uses memory that doesn t require a battery to store a variety of settings. What we refer to as Persistent Memory stores all the User Preferences, as well as all the filter settings, the set temperature, and the heat mode. Persistent Memory is not used for Time of Day. Time of Day needs to be kept running (not just stored) while the power is off, so a separate Real Time Clock feature (on all models except the EL000) keeps track of Time of Day while the unit is off. Time of Day Retention, and Time of Day Retention alone, is controlled by the J9 jumper. J9 must be set according to main system panel used. RTC Enabled (Not Jumpered) Switchbank A J9 RTC Disabled (Jumpered) J9 Switchbank B message on power up: If appears before (and instead of) or, you have not configured DIP Switches and/or Software Configuration Settings in a valid manner. This must be corrected before you can reset Persistent Memory. The switch numbers, jumpers, or configuration settings displayed after are ones with which the system has found a configuration problem. For example: would mean that the combination of how you ve set A5 and how you ve set B is not supported on this system. would mean that there is a problem with jumper J99 would mean that the combination of how you ve set pump for -speed and blower for -speed is not supported on this system. would mean that the combination of how you ve set DIP switches which have been assigned to pump and blower is not supported on this system. Power Up Display Sequence Upon power up, you should see the following on the display: Three numbers in a row, which are the SSID (the System Software ID). The third display of these numbers is the Software Version, which should match the version of your system. For example, if these three numbers are, that is a Mach EL8000 at version 6. If there is a Configuration Error, the message (see above) will appear at this point (and none of the messages below will display). Otherwise what comes next is: An indication of either the input voltage detected (EL000/EL000), or the heater wattage range supported (EL8000/GL000/GL8000). Heater wattage display: means the system supports a heater from kw to kw. means the system supports a heater from kw to 6 kw. means the system supports a kw heater only. (These ranges may be modified slightly in the case of special heaters, which the next bullet covers.) Input voltage display: A system showing supports kw to 6 kw heaters. A system showing supports the very same heaters, although at 0V those heaters will function at only /4 of their 40V rated wattage. (The system shows only either or as a general indication of input voltage; it does not show the actual input voltage.) If your system is using a special type of heater, a display such as may appear next. If your system is using the generic Balboa heater, no heater type display will appear. or will appear to signal the start of Priming Mode. At this point, the power up sequence is complete. Refer to the User Guide for the ML Series panel on your system for information about how the spa operates from this point on. Page 4

W W Wiring Configuration and DIP Settings Setup (As Manufactured) TORQUE RANGE FOR TB: 7-0 IN. LBS. K7 Pb CLASS G FUSE 0A FUSE A 50V J J8 F7 K4 J K F0 FUSE 0A 50V F4 WHT AC J J9 J8 J4 J4 J48 TB Balboa EL000 Mach III P/N 95 REV C NEUTRAL WHITE HOT BLACK HOT RED COPYRIGHT 005 MADE IN U.S.A. J5 J54 J55 J5 J6 RED AC BLK AC HTR 5.5 kw F FUSE 0.A 50V HTR K8 K6 W -Spd P G W B R F K Ozone 4hrs T P-LO 4HR J5 V-A E.GND J J97 J9 G W B R Ozone SWITCHBANK A W7 W J J4 G W B R J7 J7 J70 J0 J9 MAIN PANELS AUX. PANELS V Light J5 BLK V-B J7 J6 K with P Low U4 ADCM J8 P LO ALRM J69 J J95 J85 J96 K runs REMOTE J4 J0 J80 J8 EXT TST AUX. F CFG SENS. A SENS. B VAC J86 K Spa Light W9 J WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches. WARNING: Persistent Memory (A) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page) TST AUX. F CFG A, Test Mode OFF A, Low High Amp A, Filter by Time Duration A4, Hr Time A5, Degrees F A6, Short Timeouts SENS. A Switchbank A When the Logic Jumper is not installed on J8 (CFG), DIP Switch Settings are enabled. DIP Switches will then operate as shown below. A7, Cleanup Cycles OFF A8, Pump Disabled A9, No Circ Pump A0, Blower Disabled A, Do Not Use A, Memory ON J J96 Circ/Ozone 4hrs Page 5 K runs per J J7 SSID # 00 04 V Light Wiring Color Key 0 Volt Connections 40 Volt Connections Black AC Jumpers Volt Connections Relay Control Wires Board Connector Key Typically Line voltage Typically Line voltage for -speed pumps Neutral (Common) 4 Ground Note flat sides in connector

DIP Switches and Jumpers Definitions WARNING: Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components. Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system. Contact Balboa if you require additional configuration pages added to this tech sheet. DIP Switchbank A Key A...Test Mode (normally Off) A...In ON position, heater can run while any/all high-speed pumps or blowers are running. (High amperage)...in OFF position, heater is disabled while any high-speed pump or blower is running. (Low amperage) A...In ON position, filter cycles are programmed by duration...in OFF position, filter cycles are programmed to start and end times A 4...In ON position, displays time in 4 hours (military time)...in OFF position, displays hour time A 5...In ON position, displays temperature in Celsius...In OFF position, displays temperature in Fahrenheit A 6...In ON position, Equipment timeout 0 minutes (4 hours for Pump Low)...In OFF position, Equipment timeout 5 minutes ( hours for Pump Low) A 7...In ON position, Cleanup Cycle 0 minutes after spa use/timeout, Pump Low & Ozone run for hour....in OFF position, no Cleanup Cycle A 8...In ON position, enables Pump (A0 must be Off)...In OFF position, disables Pump A 9...In ON position, Circ Pump 4 Hours with F Shut-off. *See note below....in OFF position, no Circ Pump A 0...In ON position, Blower enable when Pump is disabled (A8 must be Off)...In OFF position, Blower disabled A...In ON position, DO NOT USE. *See note below....in OFF position, Pump is two-speed A...Persistent memory reset (normally off) (used when spa is powering up) *Note: For systems with a Circ Pump, software must be v0 or higher and requires X-0 expansion board to be installed. Also, the Ozone generator, if installed, will be moved to X-0 board. Jumpers J Jumper on Pins and will power J9 (Ozone) with Pump Low. Jumper on Pins and will power J9 to run 4 hours. J7 Jumper on Pins and will power one leg of J (Spa Light) at 0 Volts AC. Jumper on Pins and will power one leg of J (Spa Light) at Volts AC. Note: W9 controls voltage on the other leg of J and must be set for the same voltage. J96 Jumper on Pins and will operate the relay K with Pump Low. Jumper on Pins and will operate the relay K independently. Page 6

Ozone Connections Ozone Connector Voltage: The EL circuit board is factory configured to deliver a preset voltage (0V or 40V) to the on-board ozone connector (J9). See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage. For 40V output W connects to Red AC and for 0V output W connects to White AC. The voltage to the ozone connector can be changed in the field if required. W just needs to be set for the required voltage. Balboa Ozone Generator: If the board is set up to operate a 0V ozone generator, the connector on the ozone generator is likely to be configured correctly, but should be compared to the illustration below. If a 40V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next to the green ground wire as described below. Note: A special tool is required to remove the pins from the connector body once they are snapped in place. Check with your Balboa Account Manager for information on purchasing a pin-removal tool. Balboa Ozone connector configuration for 0V 60Hz Line - Black conductor Use this slot for the leftover Red conductor Common - Install the White conductor here for 0V ozone Ground (Green) conductor B G Balboa Ozone connector configuration for 40V 60Hz Line - Black conductor Use this slot for the leftover White conductor Common - Install the Red conductor here for 40V ozone Ground (Green) conductor Flat sides of sockets as shown B G W wire determines voltage J W G R B W K T P-LO 4HR F0 J J97 FUSE 0A 50V J9 W7 W J FUSE A 50V F4 G N V-B BLK J6 J7 K J85 J95 P LO ALRM J96 J86 K G N W9 J Line - Black conductor Use this slot for the leftover conductor Common - Red for 40V or White for 0V ozone (See W wire) Ground (Green) conductor F J5 V-A MAIN PANELS AUX. PANELS J7 J70 J0 J9 ADCM J69 U4 J80 J0 REMOTE K E.GND SWITCHBANK A J4 J J4 J7 J5 J8 J8 EXT TST AUX F CFG SENS A SENS B VAC Page 7

Panel Configurations Note: Connects to Main Panel terminal J70 or J7 NON-TIME CAPABLE ML400 PN 5684 with Overlay PN 45 Jets Aux Temp Light Heat Page 8