General Specifications

Similar documents
Model DM8 Vibration Type Density Meter

General Specifications

General Specifications

General Specifications

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

General Specifications

Specifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure

General Specifications

General Specifications

General Specifications

Model PH8USF ULTRASONIC OSCILLATOR (Explosionproof Type) Model PH8AL ALARM BOX

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

IN-SITU ZIRCONIA OXYGEN ANALYZER <HART communication>

Intelligent ph Converter PH400G. PH400G Intelligent ph Converter. Bulletin 12B7C1-01E.

General Specifications

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

13-1. Temperature Regulator

General Specifications

Disc Type Steam Trap TSD-42

General Specifications

General Specifications

Analog Transmitter AT1000 AT1

Zirconia Oxygen Gas Analyzers

IN-SITU ZIRCONIA OXYGEN ANALYZER

General Specifications

Section B Field Instruments

Personal ph, ph/orp, Conductivity Meters

IN-SITU ZIRCONIA OXYGEN ANALYZER

Zircomat Oxygen Analyzers

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement

4.Metering Pumps CONSTRUCTIONS. CR-N Series CRA-N Series: servo control model. CRP-N Series

Model 144H. Product Data Sheet , Rev DB February Content

Personal ph, ph/orp, Conductivity Meters

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

Rosemount 3051CFP Integral Orifice Flowmeter

Personal ph, ph/orp, Conductivity Meters PH71/PH72/SC72

Azbil introduction 2015

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Temperature Measurement Transmitters for field mounting

Tank Gauge Transmitter AT-5000

General Specifications

SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Dust Concentration Meter

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Rosemount 8800D Series Vortex Flowmeter

Ultrasonic Point Level Switches

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

PUV, PIR and PFO Series BROCHURE

User s Manual. CONDUCTIVITY METERING SYSTEM Model SC8SG CONDUCTIVITY DETECTOR IM 12D08G02-01E IM 12D08G02-01E. 5th Edition

Gas cooler series TC-Standard+ X2

General Specifications

User s Manual YTA610 and YTA710 NEPSI Certification

SECTION METERS AND GAGES FOR PLUMBING PIPING

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

BOILER HOUSE PRODUCTS GMS

Oil Leak Detector NAR300 System

CM2-MVC Steam Flow Meter STEAMcube Model: MVC30/MVC31. User's Manual

Ar-Mite TM Low Flow Armored Flowmeter

HL45, HL80 Thermostatic High-Low Valves

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

TMV45 & TMV80 Standard Thermostatic Mixing Valves

% by up ctoond re-heater and

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.

Electronic Pressure Digest. Pressure and Temperature Transmitters

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

NORTH AMERICAN ADVANCED TECHNOLOGIES, INC.

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Model Q45P/R. ph/orp Monitor...

Vibracon LVL-A* Level limit switch for liquids, compact design

NWA300 Field-Based Analog 4-20mA DC Current Meter User's Manual OM

1. Division 23 Section "Steam and Condensate Heating Piping" for steam and condensate meters.

Advanced Ultraviolet Burner Controller

Retrostat Kits for Johnson Controls D/N or H/C Thermostats

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

89BSD Digital Output

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

Differential pressure gauge with electrical contact type Model: P650 series

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

General Specifications

CKD refrigerating type dryer

Rosemount 2090F Hygienic Pressure Transmitter

Model Q45P/R. ph/orp Monitor...

Technical Information OUSTF10

Ultrasonic Switches. Features & Benefits

OIL FILM DETECTOR (Long-distance correspondence Version)

BINDER Scientific Product Catalog

PARTICULATE EMISSION MONITORING

General Specifications

Absolute and Gage Pressure Transmitter

Flow Measurement SITRANS F C

Gas cooler series TC-Standard+

Transcription:

General Specifications Model DM8 Vibration Type Liquid Density Meter Overview In 1967, YOKOGAWA developed the Model VD6 Vibration Type Liquid Density Meter in response to user requests for an online density meter, to assist in process automation and saving labor resources and energy while further improving and stabilizing quality. This was an important development in the instrumentation field, because density is a fundamental physical quantity, the accurate measurement of which is important for almost all processes. The VD6 density meter has gone on to develop an excellent reputation as a highly stable high sensitivity meter. The Model DM8 Vibration Type Density Meter is a highly reliable, multi-function meter developed on the basis of our experience with the VD6 and which takes advanrage of the latest computer technology to integrate a wide range of sensor techniques. Its converter incorporates a microprocessor to directly convert frequency signals from the sensor into density values and display them and is provided with a variety of functions such as one-touch calibration, self diagnosis, digital output (RS-232C), etc. System Configuration Model VD6SM Sampling unit Model VD6D Model VD6DF Detector Model VD6DS Model DM8W Special cable Max. 2 km Model DM8C Converter Standard Specifications Transmission signal 1. General Specifications Measurement object: Liquid density Measurement principle: Vibration density measurement Measurement range: Density: 0.5 to 2.0 g/cm 3 Temperature: 10 to C Distance between Detector and Converter: Up to 2 km Power supply: 90 to 132 V AC or 180 to 264 V AC, 50/60 Hz Power consumption:20 VA 2. Detector (1) General Purpose Detector Model VD6D Detector construction: Non-explosion protection, rainproof construction Case material: Cast Aluminium alloy Case coating: Epoxy rasin, baked finish Case color: Jade green (equivalent to Munsell 7.5BG4/ 1.5) Wetted part materials: Base: SUS316 Vibrator: SUS316 or Ni (Au Blazing: BAu 4) Converter Detector Measuring liquid temperature: 10 to C Measuring liquid pressure: 2 MPa G or less Withstandable pressure: 4.9 MPa G Steam tracing: Available Process connection: Rc1/4 Electrical connection: G3/4 Mounting: JIS 50A pipe mounting Ambient temperature: 10 to 50 C Weight: Approx. 12 kg (2) Flameproof (Explosionproof) Detector Model VD6DF Detector construction: TIIS d2g3 or NEC Class I, Division 1, Groups C and D, Flameproof construction Process connection: Rc1/4 or 1/4NPT female (only for VD6DF- *B/FM) Electrical connection: G3/4 or 3/4NPSM female (only for VD6DF- *B/FM) Specifications are the same as for the (1) General Purpose Detector except for the above construction. (3) Sanitary Use Detector Model VD6DS Process connection: Special joint for connection to JIS 6A pipe (with gasket) Wetted part materials: Added to the standard model Gasket: Teflon O-Ring: Viton Stream tracing: Not available Specifications are the same as for the (1) General Purpose Detector except for the above two items. Temperature detector protecting tubes are detachable. These detectors cannot be used with highly corrosive liquids and solutions likely to stick to sensors. If it is desired to be applied to solutions containing slurry or sludge, consult with YOKOGAWA. For measuring NaOH solutions, use sensors with a nickel vibrator. Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5617 Fax.: 81-422-52-6792 Copyright Apr. 1998 7th Edition Apr. 2009

3. Converter Model DM8C Display: Digital display, five digits LED Display contents: Density (g/cm 3 ) after conversion to reference temperature (center temperature) Density (g/cm 3 ) at the measuring temperature Measuring liquid temperature ( C) Set density value for the calibration liquid (g/cm 3 ) (displayed on call) Temperature coefficient set value for the calibration liquid ( 10 5 g/cm 3 / C) (displayed on call) Output signal set value (%) (displayed on call) Setting for output range low limit (g/cm 3 ) (displayed on call) Setting for output range high limit (g/cm 3 ) (displayed on call) Reference temperature (center temperature) set value ( C) (displayed on call) Temperature coefficient set value for the measuring liquid ( 10 5 g/cm 3 / C) (displayed on call) Fault contents display Output signal: Analog output: 4 to 20 ma DC (load resistance 550 or less), and 0 to 1 V DC (load resistance 250 k or more), isolated output. Density (g/cm 3 ) after conversion to the reference temperature Digital ooutput: To RS-232C Density (g/cm 3 ) after conversion to the reference temperature Density (g/cm 3 ) at the measured temperature Measured liquid temperature Calibration state Failure alarm Output signal span: 0.05 to 0.5 g/cm 3 settable Reference temperature set range: 0 to C (in increments or decrements of 1 C) Contact output on failure: One point. Contact closed on failure or power failure. Contact open when normal. Permissible voltage: 220 V DC, 250 V AC Permissible current: 2A (resistive load) Permissible contact power: 60 W Fault detecting contents: Detector failure and converter failure Failure output: Analog signal: Falls down to about 10 % of the output signal span Digital signal: Error message outputs Output signal hold: Holds in the CAL. or Maintenance mode. Settable range for temperature coefficient: 0 to 0.002 g/ cm 3 / C Calibration procedure: One-touch calibration by strong calibration liquid density (one-point calibration) Ambient temperature: 10 to 55 C Power supply: 90 to 132 V AC or 180 to 264 V AC, 50/60 Hz Case construction: Dust and rain proof construction Coating color: Door: Equivalent to Munsell 2.8GY6.4/0.9 Case: Equivalent to Munsell 2.0GY3.1/0.5 Coating finish: Baked finish epoxy resin 2 Mounting: To panel, wall or JIS 50A pipe Air purge connector: Rc1/8, Rc1/4, or 1/4NPT female is also optionally available Electrical connection: Five holes, 27 mm dia. Attached with four plastic waterproof plugs equivalent to JIS A15, and one plastic waterproof plug equivalent to JIS A20. Weight: Approx. 7.5 kg 4. Special Cable Model DM8W Type: Six-conductor double shield cable Insulator: Polyethylene Sheath: Polyvinyl chloride Insulation resistance: 0 M /km Conductor resistance: 15.31 /km Finished O.D.: 15.8 mm 5. Sampling Unit Model VD6SM External dimensions: Approx. 400(W) 400(D) 1350(H) mm Coating finish: Epoxy resin, baked gray finish (equivalent to Munsell N7) Watted part materials: SUS316, Teflon (gasket for flowmeter, pressure gauge and strainer), Ni for /FN option. Weight: Approx. 80 kg Process conditons: Inlet temperature: 0 to C Inlet pressure: 0 to 1 MPa or 0 to 2 MPa Required differential pressure: At least kpa Flow rate: 1 to 10 l/min Inlet Outlet F TI NV1 FM PI BV1 Sampling System Diagram NV2 DD NV4 NV3 Element specitications F: Strainer body; SUS316, element; SUS316, Ni fo /FN option PI: Pressure gauge, 0 to 1 MPa or 0 to 2 MPa, SUS316 TI: Thermometer, 0 to C or 0 to 150 C, SUS316 FM: Flowmeter, tapered metal tube flowmeter, 1 to 10 l/ min, SUS316 BV: Ball valve, SUS316 NV: Needle valve, SUS316 DD: Density detector Note: This sampling system cannot normally be applied to food applications, if it is desired to be applied to food applications, consult with YOKOGAWA. Characteristics (overall characteristics after combing the detector and the converter) Repeatability: 5 10 4 g/cm 3 (for digital output) 1 % of span (for analog output) Linearity: ±0.5 % of span (when span is 0.2 g/cm 3 or less) ±1 % of span (when span is more than 0.2 g/ cm 3 ) Temperature characteristics: ±0.5 % of span/±10 C (Compensating error for changes in the measuring liquid temperature and detector temperature) All Rights Reserved. Copyright 1988, Yokogawa Electric Corporation 7th Edition Apr.09,2009-00

3 Flow characteristics:±0.1 % of span in the 0 to 5 l/min range Pressure characteristics: ±0.0005 g/cm 3 /±98 kpa change Viscosity error: ±0.1 % of span in the 0 to 1500 cp range Standard Accessories Syringe (for injecting standard solution or solvenet) Brush (for cleaning the detector) Allen wrench for terminal box Allen wrench for locking the cover O-Ring Silica gel Fuse for the converter (3A) 1 bag 2 packs Model and Suffix Codes 1. Detector ( 1 ) General Purpose Detector Model Suffix code VD6D Vibrator -S3 material -N1 * B (2) Flameproof Detector Model Suffix code VD6DF Vibrator -S3 material -N1 * B (Option) Option code for Detector (VD6) for Converter (DM8C) General purpose detector SUS316 Ni Style B Option code Flameproof detector SUS316 Ni Style B /FM NEC Class I,Division 1,Group C and D, explosionproof (3) Sanitary Use Detector Model Suffix code VD6DS Vibrator -S3 material * B 2. Converter Model DM8C Power supply Suffix code -A1 -A2 *C (Option) Air purge connector 3. Special Cable Model DM8W Cable length Option code Option code /AP1 /AP2 Suffix code Option code -L *A Sanitary use detector SUS316 Style B Converter 90 to 132V AC, 50/60Hz 180 to 264V AC, 50/60Hz Style C Rc1/4 1/4NPT female Special cable Length (unit: m) Style A (Note) Enter the cable length in -L in m. [Example] L0050 for 50 m L0 for m L2000 for 2 km 4. Sampling Unit Model Suffix code Option code VD6SM Piping connection Pressure guage range Temperature range Style code Option -JPT -10K -20K -150-300 -151-301 -WST -PG10 -PG20 -PK10 -PK20 -T -T150 Material of strainer element Sampling unit for Vibration type Density Meter (Note 1) Rc1/2 JIS 10K 15 RF Flange JIS 20K 15 RF Flange ANSI Class 150 1/2 RF Flange ANSI Class 300 1/2 RF Flange JPI Class 150 1/2 RF Flange JPI Class 300 1/2 RF Flange 1/2 inch welding socket 1 MPa 2 MPa Diaphragm type 1 MPa Diaphragm type 2 MPa 0 to C 0 to 150 C Style B * B /ST With steam tracing (Note 2) /FN Ni (Note 3) (Note 1) VD6SM Sampling unit is not including Detector. Order detector VD6D or VD6DF, separately. DM8C converter and special cable DM8W are also required for sampling system of density meter. (Note 2) If stean tracing is necessary, select the diaphragm type pressure guage. (Note 3) If measuring solution includes NaOH ( 30%), select option code /FN of Ni. All Rights Reserved. Copyright 1988, Yokogawa Electric Corporation 7th Edition Apr.09,2009-00

4 Wiring Connection Detector Special cable Converter A2 A3 A4 A6 A5 B4 B5 RED BLUE YELLOW BROWN GREEN WHITE GRAY A2 A3 A4 A6 A5 B4 B5 G L1 L2 N.C C SG RD TD + - + - Alarm Digital signal 0 to 1V DC 4 to 20mA DC Closed when a failure is detected or the power fails. Density signal after being converted to the reference temperature state Density signal before being converted to the reference temperature state Temperature signal Density signal after being converted to the reference temperature state Power supply External Dimensions 1. Detector General Purpose and Flameproof Detector Models VD6D and VD6DF 246 110 104 153 192 Sample lnlet Rc1/4 (1/4NPT for VD6DF- *B/FM) 78 Steam Connection Rc1/4 (1/4NPT for VD6DF- *B/FM) Sample Outlet Rc1/4 (1/4NPT for VD6DF- *B/FM) 50A (2-inch) Pipe (Horizontal or Vertical) 116 74 342 58 Electrical Wiring Port G3/4 (3/4NPSM for VD6DF- *B/FM) 200 160 146 All Rights Reserved. Copyright 1988, Yokogawa Electric Corporation 7th Edition Apr.09,2009-00

5 Sanitary Use Detector Model VD6DS 246 110 104 153 192 Gland Sample lnlet * 166 Sample Output * 116 74 103 345 73 50A (2-inch) Pipe (Horizontal or Vertical) 58 Electrical Wiring Port G3/4 160 200 146 * The ends of sample inlet and outlet are connected with 6A (1/8-inch) pipe in welding. The pipe may be removed by loosing the gland. All Rights Reserved. Copyright 1988, Yokogawa Electric Corporation 7th Edition Apr.09,2009-00

6 2. Converter Model DM8C Wiring port holes (5-ø27) (with rubber plugs) Mounting bracket (applicable with any mounting method to panels, walls or pipes) Mounting panel thickness Max. 12 Purge air inlet Rc1/8 Purge air outlet (with seal sheet) Pipe mounting bracket Mounting pipe (50A (2-inch) pipe) 3. Special Cable Model DM8W B4 WHITE GRAY B5 110(from A) A2 RED A3 BLUE 110(from A) A5 GREEN Density detector A4 YELLOW 130(from A) 110(from A) A6 BROWN 60(from A) 60 (from A) 60(from A) A B 50m, m, or 2km 15.8 Density converter (from B) B4 (from B) WHITE 80 B5 (from B) GRAY 120 A2 RED A3 (from B) BLUE 110 A4 (from B) YELLOW A5 (from B)90 GREEN A6 (from B)80 BROWN All Rights Reserved. Copyright 1988, Yokogawa Electric Corporation 7th Edition Apr.09,2009-00

7 4. Sampling Unit Model VD6SM 270 400 Steam Trap 4-15 holes For Anchor Bolts Thermometer 300 400 50 50 Pressure Gauge P - P view (Steam trace only) (*1) Note: Some detail of steam trace tube omitted in this drawings. (*1): Only for with steam trace.(option /ST) Detector Flowmeter P P 1350 Condensate Outlet(*1) Sample Outlet 125 150 Steam Inlet(*1) Sample Inlet strainer 150 Approx.407 34 200 L L 200 () (for flange) (for welding socket) Model and Codes VD6SM - JPT - P 0 - T1 0 B VD6SM - 10K - P 0 - T1 0 B VD6SM - 20K - P 0 - T1 0 B VD6SM - 150 - P 0 - T1 0 B VD6SM - 300 - P 0 - T1 0 B VD6SM - 151 - P 0 - T1 0 B VD6SM - 301 - P 0 - T1 0 B VD6SM - WST - P 0 - T1 0 B Connection Type Rc 1/2 female JIS 10K 15 RF Flange JIS 20K 15 RF Flange ANSI Class 150 1/2 RF Flange ANSI Class 300 1/2 RF Flange JPI Class 150 1/2 RF Flange JPI Class 300 1/2 RF Flange 1/2 B Welding Socket L 0 All Rights Reserved. Copyright 1988, Yokogawa Electric Corporation 7th Edition Apr.09,2009-00

8 Inquireis sheet for the Vibration Liquid Density Meter Thank you for inqurity on our vibrationliquid density meter. Please specify your requiremets by checking the appropriate boxes and filling in the blanks with the requested information. 1. General Items Company name: Contact person: Section: Address: (Phone No. ) Plant name: Measurement location: Purpose: Indication Recording Alarm Control 2. Measurement conditions (1) Liquid temperature: to, normally [ C] (2) Liquid pressure: to, normally [kpa] (3) Liquid flowrate: to, normally [l/min] (4) Slurry or soiling components?: Yes No (5) Name of measured liquid: (6) Composition of measured liquid: (7) Other: 3. Installation location (1) Ambient temperature: (2) Installation location: Outdoors Indoors (3) Other: 4. User requirements (1) Measurement range: (2) Vibration material: SUS316 Ni (3) Cable length between detector and converter: m (4) Power supply: 90 to 132 V AC 180 to 264 V AC (5) Other: All Rights Reserved. Copyright 1988, Yokogawa Electric Corporation 7th Edition Apr.09,2009-00