UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

Similar documents
UL HAZARDOUS LOCATIONS SERVICES

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

AGENDA. NEC Code-Making Panel 14. Report on Comment Meeting. November 28-December 1, Redondo Beach, CA

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Certificate of Compliance

Certificate of Compliance

Approval Standard for Electrical Equipment for Use in Hazardous (Classified) Locations - General Requirements

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA

A Guide to Safe Electronic Weighing in Hazardous Locations

Certificate of Compliance

LIGHTING in Hazardous (Classified) Locations

Approval Standard for Electric Equipment for use in Hazardous (Classified) Locations General Requirements

Model 144H. Product Data Sheet , Rev DB February Content

Specifying Temperature Sensors for Hazardous Areas

Certificate of Compliance

Certificate of Compliance

Overview of Hazardous Locations as They Relate to Solenoid Valves

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

CLASSIFICATION COMPARATOR

Guide for hazardous areas

Certificate of Compliance

Model 144H. Product Data Sheet , Rev DB February Content

Certificate of Compliance

Certificate of Compliance

Intrinsically Safe or Explosionproof? Understanding the technology

Certificate of Compliance

Electronic Safety. Hazardous Location. By Jim Marquedant

Introduction to Hazardous Electrical Location Classifications

Certificate of Compliance

Certificate of Compliance

Smoke detection in hazardous areas:

Certificate of Compliance

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

INTERNATIONAL STANDARD

Installation guide for hazardous areas

FLASHLIGHT ANSI STANDARDS

Official Journal of the European Union

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

[ TECHNOLOGY ] and does this definition affect a burner.

S T R I T T & P R I E B E I N C.

Certificate of Compliance

INTERNATIONAL STANDARD

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

ATEX, NOMENCLATURE AND CODING

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Tank Gauging System Special Safety Instruction

Understanding Hazardous Locations Concepts

Certificate of Compliance

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Integrated Solutions Low Voltage Systems

FLASHLIGHT ANSI STANDARDS

Official Journal of the European Union

Australian/New Zealand Standard

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

An Urgent Bulletin from CSA Group

Beamex. Calibration White Paper. Calibration in hazardous areas

Dependable Solutions for Gas Detection

SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

Beamex Calibration White Paper. Calibration in hazardous areas

IECEx Certificate of Conformity

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

White Paper: Hazardous area classification in a nutshell and overview of Arista Industrial computers

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Annubar Flowmeter Series

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

Rosemount 752 Fieldbus Remote Indicator

(German speaking trainers with English written slides)

Inductive slot sensor

Guide to Explosion Protection and Plant Safety

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Guide to Intrinsically Safe Portable Radios

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Description. Applications

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Oil & Gas Oil & Gas. Control Control. every move. Directional Control Valves & Regulators Pressure Controls Temperature Switches Level Controls

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

ATEX, NOMENCLATURE AND CODING

CONTROL BE MADE CHANGES MAY NOT. Page 1

LTFX Electric Tank Immersion Heaters Installation Instructions

Numerical Standards Listing

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Training, Assessment, Consultants for Hazardous & Industrial Areas

Process Instrumentation. Product Guide. Registered Quality System to ISO 9001

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Certification Supplement Manual

Technical Information

ABB s ATEX jargon buster explains the terminology users are likely to encounter when purchasing motors for hazardous areas.

Transcription:

Note: While this material was originally prepared for presentation in February 1999, it has been updated to reflect the evolving technical requirements now applicable as of April 2003. UL Topic III Converting European EEx Certificates Into North American Division Certificates

Converting Certificates Zones to Divisions Applicable European Norm EEx requirements Applicable North American Division requirements 3rd-Party Certification vs. Self-Declaration Converting EN Zone 0 to UL Class I, Division 1 Converting EN Zone 1 to UL Class I, Division 1 Converting EN Zone 1 to UL Class I, Division 2 Converting EN Zone 2 to UL Class I, Division 2 Overview of Class I, Division Protection Methods

Applicable European Norm Requirements EN 50014: Electrical apparatus for potentially explosive atmospheres - General requirements EN 50015: Electrical apparatus for potentially explosive atmospheres - Oil immersion o EN 50016: Electrical apparatus for potentially explosive atmospheres - Pressurized apparatus p EN 50017: Electrical apparatus for potentially explosive atmospheres - Powder filling q EN 50018: Electrical apparatus for potentially explosive atmospheres - Flameproof enclosure d EN 50019: Electrical apparatus for potentially explosive atmospheres - Increased safety e EN 50020: Electrical apparatus for potentially explosive atmospheres - Intrinsic safety i EN 50021: Specification for electrical apparatus with type of protection n EN 50028: Electrical apparatus for potentially explosive atmospheres - Encapsulation m EN 50039: Electrical apparatus for potentially explosive atmospheres - Intrinsically safe electrical systems "i" EN 50284: Special requirements for construction, test and marking of electrical apparatus of equipment group II, category 1 G

Applicable UL Requirements UL 515 ANSI/UL 525 ANSI/UL 583 ANSI/UL 674 ANSI/UL 698 UL 698A ANSI/UL 781 ANSI/UL 783 ANSI/UL 823 ANSI/UL 844 ANSI/UL 877 ANSI/UL 886 ANSI/UL 894 Electric Resistance Heat Tracing for Commercial and Industrial Applications Flame Arresters Electric-Battery-Powered Industrial Trucks Electric Motors and Generators for Use in Division 1 Hazardous (Classified) Locations Industrial Control Equipment for Use in Hazardous (Classified) Locations Industrial Control Panels Relating to Hazardous (Classified) Locations Portable Electric Lighting Units for Use in Hazardous (Classified) Locations Electric Flashlights and Lanterns for Use in Hazardous (Classified) Locations Electric Heaters for Use in Hazardous (Classified) Locations Electric Lighting Fixtures for Use in Hazardous (Classified) Locations Circuit Breakers and Circuit-Breaker Enclosures for Use in Hazardous (Classified) Locations Outlet Boxes and Fittings for Use in Hazardous (Classified) Locations Switches for Use in Hazardous (Classified) Locations ANSI/UL 913 Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, and III, Division 1, Hazardous (Classified) Locations ANSI/UL 1002 Electrically Operated Valves for Use in Hazardous (Classified) Locations ANSI/UL 1010 Receptacle-Plug Combinations for Use in Hazardous (Classified) Locations ANSI/UL 1203 Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations ANSI/UL 1207 Sewage Pumps for Use in Hazardous (Classified) Locations UL 1604 Electrical Equipment for Use in Class I and II, Division 2, and Class III Hazardous (Classified) Locations ANSI/UL 2208 Solvent Distillation Units UL 2225 Metal-Clad Cables and Cable-Sealing Fittings for Use in Hazardous (Classified) Locations SU 1836 Electric Motors and Generators for Use in Class I, Division 2 and Class II, Division 2 Hazardous (Classified) Locations

3rd-Party Certification vs. Self-Declaration Risk of explosion requirements European Notified Bodies 3rd-party certify North America requires 3rd-party certification Risk of fire & Risk of electric shock" requirements Referred to as ordinary locations requirements European Notified Bodies allow self-declaration North America requires 3rd-party certification

Converting EN Zone 0 to UL Class I, Division 1 Risk of explosion requirements EN ia / [ia] requirements typically cover UL Class I, Division 1 requirements Exception is regarding U.S. Code markings (Class, Division, Group) Risk of fire & Risk of electric shock requirements No significant issues for converting EN ia to UL Class I, Division 1 Issues to consider for converting EN [ia] to UL Class I, Division 1 include: Plastics used as an enclosure, insulation, or direct support Internal component evaluations Branch circuit protection Overload & endurance testing Product specific operational safety testing

Converting EN Zone 1 to UL Class I, Division 1 Risk of explosion requirements EN Zone 1 protection methods are typically not able to be converted to UL Class I, Division 1 protection methods Exception is direct-entry flameproof, d, which can be converted into Division 1 explosion-proof, but with significant additional testing and constructional evaluation In addition, the following are still issues: U.S. wiring methods (conduit vs. cable) Sealing of entry Grounding (sizing of terminals) Metric entry thread marking Code markings (Class, Division, Group) Risk of fire & Risk of electric shock requirements Issues to consider for converting EN Zone 1 to UL Class I, Div. 1 include: Plastics used as an enclosure, insulation, or direct support Internal component evaluations Branch circuit protection Overload & endurance testing Product specific operational safety testing

Converting EN Zone 1 to UL Class I, Division 2 Risk of explosion requirements EN Zone 1 protection methods are able to be converted to UL Class I, Division 2 protection methods, but there is some additional testing EN Zone 1 protection methods that have first been converted into UL Zone 1 protection methods are allowed to be marked for Div. 2 with no further evaluation (per Section 501-1 of the 1999 NEC) Code marking issues (Class, Division, Group) still apply Risk of fire & Risk of electric shock requirements If the EN Zone 1 certificate has already been converted into a UL Zone 1 certificate, then there are no additional issues associated with the Division 2 marking

Converting EN Zone 2 to UL Class I, Division 2 Risk of explosion requirements EN Zone 2 protection methods are typically converted to UL Class I, Division 2 protection methods with minimal additional evaluation EN Zone 2 protection methods that have first been converted into UL Zone 2 protection methods are allowed to be marked for Div. 2 with no further evaluation (per Section 501-1 of the 1999 NEC) Code marking issues (Class, Division, Group) still apply Risk of fire & Risk of electric shock requirements If the EN Zone 1 certificate has already been converted into a UL Zone 1 certificate, then there are no additional issues associated with the Division 2 marking

Overview of Class I, Division Protection Methods Area Protection Methods Applicable Certification Documents USA Canada Division 1 Explosionproof enclosures UL 1203 CSA 30 Explosionproof motors and generators UL 674 CSA 145 Explosionproof industrial control equipment UL 698 CSA 30 Explosionproof portable lighting units UL 781 CSA 137 Explosionproof flashlights and lanterns UL 783 CSA 157 Explosionproof heaters UL 823 CSA 30 Explosionproof lighting fixtures UL 844 CSA 137 Explosionproof circuit breakers and enclosures UL 877 CSA 30 Explosionproof outlet boxes and fittings UL 886 CSA 30 Explosionproof switches UL 894 CSA 30 Explosionproof valves UL 1002 CSA 30 Explosionproof receptacle-plug combinations UL 1010 CSA 159 Explosionproof sewage pumps UL 1207 CSA 145 Explosionproof MC cables and sealing fittings UL 2225 CSA 174 Explosionproof other electrical equipment UL 1203 CSA 30 Intrinsic safety (2 fault) UL 913 CSA 157 Purged/Pressurized (Type X or Y) NFPA 496 NFPA 496 Division 2 Hermetically sealed UL 1604 CSA 213 Nonincendive circuits, components & equipment UL 1604 CSA 213 Non-Sparking UL 1604 CSA 213 Purged/Pressurized (Type Z) NFPA 496 NFPA 496 Any Class I, Division 1 method ---- --- Any Class I, Zone 0, 1 or 2 method UL 60079 series CSA E60079 series