Heat pump supplemental heating system for motor vehicles

Similar documents
EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

THERMAL ANALYSIS OF CAR AIR COOLER

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

REVERSIBLE R744 (CO 2 ) HEAT PUMPS APPLIED IN PUBLIC TRAINS

Influence of the method of implementing the forced air flow through the cooling system on the temperature of the coolant in heavy-duty engines

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Heating and Air-Conditioning Testing II. Climatic Test Bench

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

Low GWP Refrigerants for Air Conditioning Applications

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

NEW SOLUTIONS FOR IMPROVING THE VEHICLE HEATING SYSTEM

Increasing Fire Safety of Cologne Main Station by High Pressure Water Mist

HFCs or the Old Refrigerants - what is the best Choice?

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Chapter 10 Lyes KADEM [Thermodynamics II] 2007

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

APPLICATION OF HEAT PUMP SYSTEM FOR ECO-FRIENDLY VEHICLES

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Performance investigation of Air-conditioning system using ejector as expansion device

1+ SEER. 25% COP boost possible. Most valves expand your refrigerant EcoFlow expands your options. with silent defrost.

Induction Billet Heaters with Enthalpy Controlled Zone Heating

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

PERFORMANCE MONITORING OF A HIGH-TEMPERATURE AIR-TO-WATER HEAT PUMP WITH INJECTION CYCLE INSTALLED IN A LOW-INSULATED SINGLE-FAMILY HOUSE IN BELGIUM

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Development of Automotive Air-Conditioning Systems by Heat Pump Technology

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Experimental Performance Analysis of an Automotive Air Conditioning and Heat Pump System using R134a with and without Internal Heat Exchanger

A study of Transient Performance of A Cascade Heat Pump System

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

(12) Patent Application Publication (10) Pub. No.: US 2005/ A1

Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases

Air Conditioning System Sizing for Pure Electric Vehicle

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

ICE THERMAL STORAGE SYSTEM USING DYNAMIC ICE IN HERBIS OSAKA PHASE I AND II PROJECTS

*Bioenergy GmbH Gewerbepark Haag 3, 3250 Wieselburg Land, Austria

Experimental Investigation of a Heat Pump Assisted Fluidized Bed Dryer

ThermoSaver TM Hot Gas Defrost System

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Corn drying experiments by pilot dryer

Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

WET POSITION BOOSTER FANS FOR REDUCED POWER CONSUMPTION AND OPTIMIZED ENVIRONMENTAL PERFORMANCE OF POWER STATIONS WITH FGD AND WET STACK

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Impact of indirect evaporative air cooler type on the performance of desiccant systems

Thermal Simulation of a Heat Pipe Tempered Injection-Mould Tool

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

Performance of an Improved Household Refrigerator/Freezer

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE

Evaluation study of the performance of dual core energy recovery system for dwellings in the Arctic

Heat Pump Fluidised Bed Dryer with CO 2 as Refrigerant Measurements of COP and SMER

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Survey of the Burning Behaviour of the Refrigerant HFO-1234yf Brief Report

High Performance Diesel Fueled Cabin Heater. Abstract

Passive cooling of telecommunication outdoor cabinets for mobile base station

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Application of a hybrid control of expansion valves to a 3-ton large room cooling system

Customers. The core of our innovation. Feeding&Conveying Drying Dosing Temperature Control Refrigeration. Granulation

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Efficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station

FLOODED EVAPORATORS VERSUS DRY EVAPORATORS: IN WHICH CONDITIONS?

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

Transcritical CO2 Bottle Cooler Development

Homework Chapter2. Homework Chapter3


Sub-Critical Operation of the CO2 Expander/ Compressor

Innovative Components for Additional Heating Systems

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Figure 1: Overview of Rovinari Power Station FGD project planned situation.

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

High-efficiency Turbo Chiller (NART Series)

Fluidised-Bed Paddy Drying

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

HYBRID GAS HEAT PUMP WATER HEATER WITH THERMAL EFFICIENCY 120% 23rd World Gas Conference, Amsterdam Main Author. Atsuya Tajima Japan

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector

DRYPOInt RA. Drying. The concept determines the efficiency. DRYPOINT RA, the most economic way to dry compressed air

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

LUCKILY THERE S A BETTER WAY

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS

MINIMISING THE RISK OF WATER HAMMER AND OTHER PROBLEMS AT THE BEGINNING OF STAGNATION OF SOLAR THERMAL PLANTS- A THEORETICAL APPROACH

Development and Application of Micro Channel Heat Exchanger for Heat Pump

Experimental study on mass transfer comparison of two liquid desiccants aqueous solutions

Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

Aspirating Gas Detection CFD Modelling Predicts Application Performance

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

Transcription:

1 Heat pump supplemental heating system for motor vehicles D Antonijevic and R Heckt Visteon Automotive Systems, Visteon Deutschland GmbH, Kerpen, Germany Abstract: The paper deals with the importance of supplemental heating of motor vehicles and the possibilities of automotive heat pump system utilization. A prototype heat pump system for motor vehicles has been developed, built in a test vehicle and tested at low-temperature working conditions. Results have been analysed and the system compared with the other current-production supplemental heating systems. The proposed automotive heat pump heating system has been found to be superior to other automotive supplemental heating solutions regarding the parameters of performance, fuel consumption and operational behaviour. Keywords: 1 INTRODUCTION simple and efficient system able to improve passenger compartment heating without causing any deterioration The fast achievement and maintenance of pleasant in the performance and behaviour of the air conditioning passenger compartment temperature and humidity are system. It is important to note that nowadays nearly all of crucial importance for a high comfort level of the passenger cars in Europe (about 80 per cent) and North vehicle. Normally, in cold weather conditions, ventilation America (about 98 per cent) are manufactured with air and recirculated compartment air is heated by otherwise conditioning (AC) systems, and these already contain wasted engine heat via an adequate heat exchanger. most of the components required for a heat pump However, sometimes the waste heat available is not application. enough to achieve a comfortable passenger compartment temperature. This is increasingly the case, particularly with recent developments in high-efficiency engines with 1.1 Heat pump system architecture very low heat rejection rates [such as the direct injection To achieve a fast warm-up of the passenger compartment, (DI) diesel engine] that are used in mass-produced it is necessary to use the evaporator of the AC system passenger vehicles. The low heat rejection of these engines as a condenser of the heat pump system. This heat has made the heating of the passenger compartments exchanger is placed downstream of the conventional during wintertime a challenge, even in mild climate heater matrix (the heat exchanger that transfers heat from zones. engine coolant to cold air) within the air conditioning In current-production vehicles, comfortable space tembox. peratures are achieved by using supplementary heating Three secondary heat sources for the heat pump devices, such as a PTC heater (electrical air heater), system are available: exhaust gas, engine coolant and glow plug heater (electrical coolant-heater) or fuel-fired ambient air: coolant-heater. In view of the power consumption restrictions, low fuel efficiency and high primary cost of 1. The amount of heat available in the exhaust gas current supplementary heating systems, the aim of the depends on the engine load, and this is a major project described in this paper was to investigate the use disadvantage for utilization of this heat source. In city of a heat pump system. The objective was to develop a traffic conditions, when greatest supplementary heat- ing is required, exhaust heat is lowest and will limit The MS was received on 11 July 2003 and was accepted after revision the heating performance of the heat pump system. for publication on 18 May 2004. 2. Utilizing the heat available in the engine coolant as a * Corresponding author: Visteon Automotive System, Advanced Climate Control Systems, Visteon Technology Center, Visteon Deutschland GmbH, Viateon Strasse 10, 50170 Kerpen, Germany. email: dantonij@visteon.com secondary heat source has the advantage that its temperature increases rapidly during the warm-up of the

2 D ANTONIJEVIC AND ROMAN HECKT AC operation, and for refrigerant evaporation during HP operation) and accumulator and refrigerant routings (pipes and hoses). With the exception of the four-way valve, the two-way expansion device instead of an orifice valve and some additional routings, all the components of the combined system exist already in a standard AC system. The R134a heat pump system was designed to pre- heat the air in front of the heater core with 1.5 3 kw supplemental heating power. The rest of the heating load was to be supplied by engine coolant through a conventional heater matrix. Cold air passed through the interior heat exchanger was then heated to a certain temperature by the heater matrix. After reaching a stable coolant and/or passenger compartment temperature, the heat pump was switched off. car. The problem is that the engine coolant cannot be used at the same time in the heater matrix for heating the passenger compartment. 3. Using the ambient air as the heat source has the best thermodynamic justification since the heat is pumped out from the surrounding air. In addition, the conventional heater matrix can be used in the usual way for passenger compartment heating. A potential disadvantage of ambient air as the heat source is frost formation in the air-to-refrigerant heat exchanger under certain conditions. Taking into consideration the calculated performances and assumed behaviour of different heat pump systems, as well as number, type, dimensions and costs of the components to be added to the air conditioning system, it was decided that the heat pump with ambient air as the heat source has the best prospects for highperformance supplementary heating, with minimized fuel 2.1 Test procedure and results consumption increase at a competitive price. To verify The heat pump system was built in the test vehicle which had a 1.8 l DI diesel engine. The vehicle was fully instrumented for measuring all relevant temper- atures, pressures, velocities and fuel consumption. Tests at different ambient and driving conditions were performed. Besides collecting data relevant for the system analysis, subjective passenger compartment comfort evaluations were also performed. The procedure for evaluating the this, a heat pump system, with R134a refrigerant as its working fluid, has been designed, built in a test vehicle and tested. This paper describes the results of this programme. 2 SYSTEM DESCRIPTION heat pump system test results and their comparison with the corresponding data for baseline heating and the The layout of the combined air conditioning/heat pump other supplemental heating systems will be explained in system is shown in Fig. 1. The system consists of a comthe following example. pressor, a four-way valve, an interior heat exchanger A test was run at an ambient temperature of 11 C, [used for refrigerant evaporation during AC operation, with moderate constant driving conditions (50 km/h in and for refrigerant condensation during heat pump ( HP) third gear). During the heat pump test the refrigerant operation], a two-way expansion device, an exterior heat loop low pressure stabilized at about 1.1 bar almost exchanger (used for refrigerant condensation during immediately after the system was switched on, while the high pressure needed about 3 min to reach a stabilized pressure level of 9 bar (Fig. 2). During the rest of operation the high pressure continued to increase slowly and reached 10 bar before the heat pump was switched off (after 13 min). The corresponding temperatures of refrigerant condensation inside the interior heat exchanger were 32 C after 3 min and 42 C after 13 min. The outlet temperatures of air preheated in the interior heat exchanger ranged from 30 C (after 3 min) to 36 C (after 13 min). The air was, afterwards, further heated by the coolant in the heater matrix, before being blown into the passenger compartment at considerably higher temperature (Fig. 3) than in the case of baseline heating. The shape of the temperature curves shown in Fig. 3, with a characteristic temperature jump after 3 5 min, is the consequence of the applied test procedure: air was blown into the compartment through defrost registers until its temperature reached 35 C, and from that moment the airflow was switched to the foot registers. During the test the heat pump system reached a stable Fig. 1 Scheme of R134a AC/HP system supplementary heater output of about 1.9 kw after only

HEAT PUMP SUPPLEMENTAL HEATING SYSTEM FOR MOTOR VEHICLES 3 Fig. 2 Refrigerant pressures during maximum heat per- formance testing at T = 11 C (at 50 km/h Fig. 4 Overall heat performance during maximum heat performance testing at T = 11 C (at 50 km/h It is important to note that the heat pump system provides almost instant heating of the passenger compartment. For example, the level of 1 kw overall heating power was reached after 30 s of operation, compared with 3 min in the case of baseline conventional heating. The results achieved with the heat pump system were also compared with those available from other supplementary heating systems currently in use, namely the glow plug heater (electrical coolant-heater) and PTC heater (electrical air heater). Tests were carried out using the same vehicle and on the same driving track under the same ambient condition. The air blower level and the driving conditions were also the same in each case. To increase the comparability, the observed air temperatures were corrected with the differences in the ambient Fig. 3 Average temperatures of air blown into the compartment temperatures during the tests. (through the front foot register) during maximum heat The differences between the systems quickly became performance testing at T = 11 C (at 50 km/h obvious by comparing the average temperatures of air. R134a heat pump versus at its inlet to the passenger compartment (Fig. 3 and baseline, glow plug heater and PTC heater Table 1). For example, after 15 min the average air temperatures at the outlet of the front foot air registers that 2 min (Fig. 4). The heat pump was switched off after were reached during one set of tests were 43 C for the 13 min because the comfort level in the passenger com- baseline heating, 45.5 C with a 600 W glow plug heater, partment had been reached, as well as a sufficient performance level of the conventional heater for further compartment temperature maintenance. and about 56 C with a 1000 W PTC heater. With the heat pump system the average outlet temperature after 15 min would have been about 68 C, which is 25 K Table 1 Comparison of different heating systems at T = 11 C (at 50 km/h Average front foot outlet air temperature ( C) Time needed to Average fuel achieve comfort consumption Heating system After 7 min After 15 min (min) ( l/100 km) Baseline heating 25.3 43.0 >30 5.12 (100%) Glow plug heater (600 W ) 27.4 45.5 >30 5.80 (113%) PTC heater (1000 W ) 35.5 56.0 30 6.35 (124%) Heat pump system 44.4 68.0 13 5.96 (116%)

4 D ANTONIJEVIC AND ROMAN HECKT Overall heat performance during maximum heat per- formance testing at T = 3 C (at 50 km/h higher than in the case of baseline heating. These results have shown that the heat pump system can heat the same amount of ambient air to a higher temperature during the same time as other proposed systems. Additionally, neither the glow plug nor the baseline heater system reached a pleasant subjective comfort rating during the 30 min test. The 1000 W PTC heater reached a pleasant comfort rating at the end of the test. In contrast to the other supplementary heating systems, the heat pump reached pleasant comfort after 13 min. The heat pump system was switched off after 13 min, and the average temperature of air blown into the passenger compartment decreased slightly in the following minutes. That did not cause any thermal discomfort. Behaviour similar to that described was detected in most of the performed tests. Of course, at higher ambient temperature and/or higher engine load, heating of the passenger compartment is faster and the heat pump can be switched off after a shorter period. For example, in the test performed at an ambient temperature of 3 C (Figs 5 and 6), the comfort level was reached after only 8 9 min of heat pump operation, and the heat pump could have been switched off. 2.2 Fuel consumption The heating performance of a supplementary heating device is of course the most important parameter, but it is also very important to develop a system with high fuel efficiency. The importance of a high fuel efficiency of supplemental heating systems has increased in recent years with the increased attention to cold start emissions and emissions caused by comfort and climate devices. Fuel consumption data from the engine control unit were used to calculate instantaneous fuel consumption Fig. 6 in litres of fuel per 100 km and the average fuel consumption during the tests. Of course, the instantaneous fuel consumption under cold engine conditions was very high for all the observed cases and influenced the values of average fuel consumption. During the 30 min warm-up test at 50 km/h in third gear, the 1.8 l diesel engine with baseline heating con- sumed on average 5.1 l of fuel per 100 km (Table 1). With the 600 W glow plug heater, the average fuel con- sumption increased by about 13 per cent to 5.8 l/100 km. The 1000 W PTC heater caused an increase in the average fuel consumption of 24 per cent compared with the base- line. The R134a heat pump system caused an increase in the average fuel consumption of 16 per cent compared with baseline heating. It can be concluded that the fuel consumption of the proposed R134a heat pump system is within the range of the 600 W glow plug heater, but the heat performance is considerably higher than the heat performances of both the 600 W glow plug heater and the 1000 W PTC heater. Fig. 5 Average temperature of air blown into the compartment (through the front and rear foot registers) during maxi- mum heat performance testing at T = 3 C (at 50 km/h. R134a heat pump versus baseline 2.3 Ice formation issues During some of the tests, frost layers of different thickness, depending on ambient and operating conditions, were observed. Functional blockage of the exterior heat exchanger was never experienced, regardless of the amount of frost on the surface. Even after a 1.5 h long-distance drive test, with the heat pump constantly running, at an ambient temperature of 1 C and a relative humidity of 90 per cent, the exterior heat exchanger did not stop extracting heat from ambient air. Considering a common duration of heat pump operation before switching to heater matrix heating only, it was concluded that the frost formation issue is not of primary importance.

HEAT PUMP SUPPLEMENTAL HEATING SYSTEM FOR MOTOR VEHICLES 5 3 CONCLUSION Finally, the proposed heat pump system showed a significantly better heat performance fuel consumption The proposed R134a heat pump system is capable of ratio by compression with those of the glow plug heater supplying the passenger compartment with a significant and PTC heater supplementary heating systems. amount of supplementary heat. The output of the test system was usually in the range 1.5 3 kw, depending on the ambient temperature and driving conditions. Supplementary heat was supplied almost instantly after the heat pump was started, no matter how cold the REFERENCES engine. During the presented tests, preheating of the air in the interior heat exchanger takes a significant load 1 Kampf, H., Kunberger, O. and Weinbrenne, M. Klimatisierung von Fahrzeugen mit kraftstoffsparenden Motoren. PKWfrom the conventional heater matrix. Preheated air enters Klimatisierung, 1999, pp. 1 23 ( Expert Verlag). the heater core at higher temperature compared with the 2 Shafai, E., Wimmer, R. and Geering, H. P. A new control conventional baseline heating system, so the amount of approach for heat pump heating systems. In Proceedings heat extracted from the coolant is lower, the coolant is of 7th International Energy Agency Conference on Heat heated faster and the engine reaches optimal working Pumping Technologies, Beijing, China, May 2002, pp. 146 157. temperature in a shorter time. 3 Rice, C. K. DOE/ORNL heat pump design model, over- Frost formation on the air side surface of the exterior view and application to R-22 alternatives. In Proceedings heat exchanger was detected during some of the tests of 3rd International Conference on Heat Pumps in Cold but showed only a very small influence on the heat Climates, Wolfville, Nova Scotia, Canada, August 1997, performance of the heat pump system. pp. 43 66.