Link-Up. Solid Fuel Association Guide to Central Heating.

Similar documents
High Output Boiler Systems

Efficiency Maximiser for Solid Fuel Central Heating

Introduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.

Cylinders for Domestic Purposes Heat Pumps

Water Heating UK 14 th May 2016

ADVANCE ECB ELECTRIC COMBINATION BOILER

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...

SFA Guide to Building Regulations and Solid Fuel Heating

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

TECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS

XCEL HEAT BANKS Installation Instructions. Thermal Integration Ltd., 1-3 Wealdstone Road, Sutton, Surrey SM3 9QN.

Section 7 F/602/2884 Understand and apply domestic hot water system installation and maintenance techniques

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

Unvented Hot Water Criteria

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

INFORMATION BOOKLET NRG Zone Models 2,3 and 4 Designed, Developed and Manufactured in Ireland

THERMflow Thermal Store Cylinders

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

The stove pictured on the cover is the Evo 30 (see page 9)

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Installation & User Instructions

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

Baxi Maxflow Combi WM

TORRENT STAINLESS ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

Baxi Maxflow Combi FS

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Unvented Water Heating. Zircon

Installation Manual EXCELSIOR Unvented Water Heater

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

The stove pictured on the cover is the Evo 30 (see page 7)

Harlequin HeatStream Case Study

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

AIR ADMITTANCE VALVES FOR DOMESTIC PROPERTIES Guidance Notes

THE OXYVENT TANK. Patent No. EP INSTALLATION MANUAL. This Manual is to be left with owner. TUV Certificate of Design Approval

Instructions for Use Installation and Servicing

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

Performance on demand

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

THERMAL STORE MAINS PRESSURE SYSTEM

TORRENT ECO ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

Schuco SS-TC/SC Cylinders

AIEA Presentation. Wood pellets heating systems.

THERMAL STORE MAINS PRESSURE SYSTEM

EFG ENERGY OPTIMISING SYSTEMS

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

WRAS TEST & ACCEPTANCE CRITERIA Issue No: 1 Date of issue: October Sheet 1 of 7

Assessment Schedule - TS.6

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

VENTED CYLINDER RANGE

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2

Hot Water Supply. Dr. Sam C M Hui Department of Mechanical Engineering The University of Hong Kong

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

thermocompact High performance system boiler range

Combined electric boiler and domestic hot water store

Vented and Unvented Hot Water Systems

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Understand and apply domestic central heating system installation and maintenance techniques

Alpha CombiMax 350 and 600

Quantum. Installation, User and Service Manual. Hot Spring

A Hot water revolution

Protect Safety Alarms

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

Biomass heating: a guide to small log and wood pellet systems

Where gas is not an option,

HEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

Combi Konverter Solar System

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

Risk Assessment and Control Measures for Household Hot Water Systems

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

MORE ABOUT WOOD STOVES 1 JULY 2009.

Thermaflow. Creating Excellence, Building Reputation Unvented Water Storage From The Experts... Thermaflow Thermaflow. Thermaflow.

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

Greenstar regular and system

SEALED THERMAL STORE

Torrent GreenHeat. Design, Installation & Servicing Instructions. Open vented thermal store providing heating and mains pressure hot water

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Re n ewa b l e s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

Domestic heating by gas: boiler systems

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

WATER HEATERS INSTALLATION MANUAL

The Ultimate Solution for Electric Central Heating. Fusion. Comet

STAINLESSLITE ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

ADVANCE ELECTRIC THERMAL STORE

MEGAFLO Eco Plus Solar Unvented Hot Water Cylinders 400L -570L

Installation and Commissioning Manual

TORRENT STAINLESS INSTRUCTION MANUAL DESIGN, INSTALLATION & SERVICING ONE NAME. EVERY SOLUTION.

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

Transcription:

Solid Fuel Association Guide to Central Heating Link-Up Combining solid fuel with other central heating technologies using various methods ranging from a simple link-up to a fully integrated thermal store system www.solidfuel.co.uk

Introduction Modern integrated or linked-up systems allow customers to utilise a solid fuel boiler alongside other heating technologies such as gas, oil, heat pumps or solar thus providing maximum flexibility. Note: The information in this booklet specifically applies to open vented systems. With a very few exceptions, it is not recommended that solid fuel appliances be connected to a sealed system so it is very difficult to link up with a combination boiler or other sealed system boiler. Building Regulations The installation of any heating appliance in the UK is subject to Building Regulations. There are separate regulations for Scotland, Northern Ireland and England & Wales. All place constraints on the type of appliance which can be installed particularly in relation to minimum efficiencies. In designing a link-up system, full regard needs to be given to the Building Regulations as they cover all aspects of the installation including electrical work. Benefits of link-up - Flexible heating The real advantage of link-up is its flexibility. The consumer can enjoy the cosy comfort of a solid fuel fire or stove and at the same time, derive a wider heating contribution from it. When the fire is not lit, the primary central heating operates as normal. Interlinking appliances can be achieved in a number of different ways and the method chosen will depend on the existing system if applicable and the output of the appliances being linked. Whichever method is chosen, it is essential to ensure that in every case, the solid fuel appliance has an unrestricted open vent and separate cold feed. To further increase safety and reduce the possibility of boiling in the event of a power or pump failure, any motorised valves fitted to the solid fuel circuit should be of the normally open, powered closed type. It is possible to design a custom link-up system to suit almost any combination of technologies but the design must take into account the specific requirements and hydraulic characteristics of the different appliances and the type of system controls that are to be employed.

Section 1 - Simple Link-up How a Simple link-up works General Features of a simple link-up system:- In its simplest form, an open fire, room heater or stove fitted with a back-boiler can be linked to an existing or new central heating system. The existing or primary boiler continues to service the system as and when required. The hot water and radiators can be supplied by either or both appliances depending on the heat required. Link-up can apply to either hot water only or both hot water and radiators. Solar panels can be integrated to maximise efficiency by providing free hot water from the sun when it is available. Link-up can be very simple and inexpensive if only a limited additional benefit is required. In many cases a simple link-up is most cost effective when an open fire or stove is added to an existing central heating system. By using a boiler flue-set with domestic hot water back-boiler or a boiler stove, it is possible to improve the efficiency of a fireplace and generate additional hot water. Where a glass lined or similarly rust-proofed boiler is fitted to an open fire or stove, the boiler can be connected directly to the domestic hot water cylinder. This type of system was originally used years ago for the production of hot water from open fires but is still valid today. It can be seen from fig.1 that the solid fuel appliance uses the domestic hot water feed and vent and heats the water in the cylinder directly by passing it through the boiler. Simple indirect link-up In this instance, a standard boiler is used and the water in the cylinder is heated indirectly via a coil. It requires the fitting of an additional cold feed and expansion tank to service the new system and allows the use of a standard boiler. In the strictest sense of the word, this is not a link-up as the two appliances have a separate system and heat the same cylinder via separate coils In a house fitted with solar panels, the heat generated can be used to indirectly supply a twin coil hot water cylinder. In this way, hot water can be obtained all year round using the power of the sun backed up by your solid fuel boiler during the cooler months. Simple link-up will only provide hot water and will not assist with heating the radiators. Simple direct link-up Fig.1 Simple direct link-up Fig.2 Simple indirect link-up

Section 2 - Full Link-Up A fully linked up or integrated system enables more than one appliance to contribute to the central heating system as well as the domestic hot water. In the past there have been problems associated with linking two dissimilar heating appliances into the same heating system, especially when the appliances are located remotely from each other. These problems have included loss of heat through the unlit appliance, loss of stored hot water when the heating is on, inefficient use of the heat generated when both appliances are in operation and excessive heat produced when both appliances are operating. There are now specialised products on the market which enable link-up to be carried out successfully between any two appliances and can give different levels of control and automation to meet the customer s requirements. Electronically controlled link-up Heating Innovations Ltd have produced a control system called H2 which operates in conjunction with any solid fuel appliance with a boiler together with an existing open vented automatic central heating system. This system can also be incorporated as part of a new system to enable Link-Up to take place. Installation of the H2 unit has been made as straightforward as possible by having the electrics pre-wired leaving only external connections to be made. More details at www.h2panel.co.uk Neutral point vessel link-up- neutraliser, centraliser The use of a neutral point manifold or vessel offers a neat solution to the problems of linking appliances. This fixes the neutral point location within the system. The cold feed and open vent are both connected to the system at the neutralising chamber. Benefits of a neutral point vessel Because both appliances are only connected through the vessel which has a comparatively large volume, pumped and gravity circuits are hydraulically de-coupled so will not affect each other. In other words, the pumped circuit from a gas or oil boiler will not induce or hinder the flow through a solid fuel boiler via its gravity circuit. A system incorporating a neutralising vessel can connect several different appliances together without them interfering with each other hydraulically. Location In converting an existing system to accommodate a neutral point vessel, most of the work takes place in the airing cupboard thus avoiding general disruption within the home. Where the solid fuel appliances are on the same floor level as the vessel, elevation of the vessel and hot water cylinder is recommended. This elevation is to achieve gravity circulation and efficient venting of the system. Fig.4 Dunsley Neutralizer Fig.3 H2 Panel

www.dunsleyheat.co.uk Fig.5 Dunsley Neutralizer Typical Layout - more details at www. dunsleyheat.co.uk Fig.6 Esse Centraliser Typical Pipework Layout - more details at www.esse.com

Section 3 Thermal Store Link-Up The thermal store system takes the principle of the neutralising vessel one step further by providing considerable heat storage as well as neutralisation of water circulation. A thermal store is a large tank (typically 200-300 litres) very much like a hot water cylinder but instead of containing domestic hot water, it is filled with primary or system water. Both the appliances and heating circuits are connected directly rather than via a coil. Direct connection means that the store holds primary water. In other words it is the same water that is circulating around the stove or the gas boiler. The thermal store acts as the neutral point of the system and also stores some or all of the heat produced for later use. Domestic hot water can be supplied at mains pressure via a secondary coil inside the store or through a separate plate heat exchanger. Many different sources of heat can be integrated into the same system. Fig.7 Typical thermal store system Solar Panel Heat Leak Radiator Solar heating can either be a fully filled pressurised system or drain back system as Alternative method of providing mains pressure hot water using a plate heat exchanger piped directly into the thermal store. Note:- The same arrangement would allow connection to a sealed radiator system or underfloor heating system. Mains cold water Solar Coil Room thermostat Pump with bypass Thermal Store Solid Fuel Appliance Radiator Circuit or underfloor system

Pipework Design The output from a solid fuel stove can be turned down but not turned off. Therefore, there are two essential rules to be observed when designing the system. 1. The system must have an unrestricted open vent to atmosphere. 2. There must be scope for the dissipation of heat from the appliance in the event of a pump or power failure. A heat leak radiator should be provided sized to the turn- down output of the appliance (usually 25% of maximum output). The stove primary pipework should always be designed so that in the event of a pump failure, heat can circulate by gravity (thermosiphon) to the store or to the heat leak radiator. Where the primaries are pumped, a bypass should be fitted to the pump to facilitate an unrestricted cold feed to the appliance (10mm diameter). Important note: A stove should never be connected to an unvented cylinder unless two tiers of safety can be provided in accordance with Part G of the Building Regulations. Guidance should be sought from the manufacturer of the system. Accumulators and buffer tanks Accumulators and buffer tanks are both thermal stores, the difference between the two is the way they are used. A buffer store retains heat for later use. The buffer can supplement the output of the appliance when demand is high and store heat when demand is less. This can be particularly useful in the case of a stove which will work more efficiently and cleanly when burning at a higher rate. Stored heat can be immediately accessed without having to wait for the appliance to heat up to working temperature. A buffer will help to maintain a more consistent output from sources that may work slightly intermittently such as solar or heat pumps. An accumulator takes this a step further by storing all the heat produced by an appliance during an extended period working at full rate. This heat is then gradually used up over the course of the day. This is an ideal way to use the heat from batch log burning appliances etc. Because accumulators store more heat they are usually bigger than buffer tanks. Benefits of using a thermal store The water in a thermal store is usually stored at around 80⁰C. This water is then circulated to the heat emitters via thermostatic mixing valves. For a radiator circuit, the water would typically be mixed down to 60⁰C whilst for underfloor systems, this could be as low as 35⁰C. By storing water at a higher temperature, the charge of heat lasts longer. Additional overheat protection for thermal stores A secondary coil connected to the cold water main and controlled by an overheat valve can be fitted as shown overleaf. In the event of an overheat situation, the store can be cooled down by the coil and the heated water goes to domestic waste via a tundish.

Fig.8 Additional overheat protection To drain via tundish Cold in coil Valve opens at 95⁰C Additional notes:- To ensure a satisfactory link-up the following factors must be taken into account. 1. The priority of any design must be safety. There must be no possible danger to persons or property arising from the way a householder may use the system, even if this is unorthodox, unreasonable or ill advised. 2. Ensure separate and suitable flues exist for each appliance in use. 3. All components of the linked system must conform to all relevant Water Bye-Laws, Building Regulations, British/ European Standards and Approved Codes of Practice. 4. Since much of the pipework of an existing system will be concealed, it must all be located and correctly identified by whoever carries out the installation. 5. Any solid fuel appliance must always have a separate cold feed and vent which must be permanently open and unobstructed at all times without valves. Many modern gas and oil boilers operate with sealed and pressurised systems which are not suitable for linking to an open vented system. 6. The float valve in the feed and expansion cistern and the overflow pipes must be made of copper. The Solid Fuel Association is the UK s foremost authority on all aspects of domestic solid fuel heating. We are happy to offer expert guidance to both professionals and consumers alike. To find out more about solid fuel, visit our website at www.solidfuel.co.uk Or call us on 01773 835400