Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions Part No , Part No Part No

Installation Instructions

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

Installation Instructions

Installation Instructions

Installation and Operating Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions Part No

Installation Instructions

Installation Instruction

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

Installation Instructions

Installation Instructions

Owner s Information Manual

Installation Instructions

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY

Fig. 1 - Unit PGD4, PGS4, WPG4

Electric Heat Accessory Installation Instructions

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS Low Ambient Kit NASA201LA, NASA401LA

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

Installation Instructions

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

Installation Instruction

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Installation Instructions

Installation Instructions Dual Fuel Ranges

Installation Instructions

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

Installation Instructions

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

Installation Instructions

Installation Instructions

Owner s Information Manual

Installation Instructions

e Bath Fan with Light User s Guide

Installation Instructions

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

Installation Instructions

Installation Instructions

Rotary XL (558 Series) and Classic (548 Series)

Installation Instructions

Fig. 1 - Unit PHD4 and WPH4

Commercial Water Heater Replacement Parts. Price List. For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB. Prices Effective

e Bath Fan with Light User s Guide

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

e Bath Fan with Light User s Guide

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) CONTROL BOX KIT (12 VDC HEAT/COOL)

Your safety and the safety of others are very important.

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

Installation Instructions

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

LGB Gas fired boiler

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Installation Instructions

Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER

Service and Maintenance Instructions

Installation, Operation & Maintenance: Field-Installed Electric Heater for RXT Series Units

FIREPLACE INSTALLATION

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

V SERIES HDR GAS RANGES

14PRR62XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 14PRR62(X)

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Installation Instructions

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

Installation & Troubleshooting Requirements

INSTALLATION INSTRUCTIONS

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

e Heater/Exhaust Fan/Light User s Guide

INSTALLATION INSTRUCTIONS

Transcription:

Installation Instructions Blower Packages For Gas Furnaces KCBBA00TG KCBBA00TG NOTE: Read the entire instruction manual before starting the installation. INTRODUCTION When upgrading a Coleman, Intertherm, or Miller gas furnace for use with an outdoor heat pump or air conditioner, the blower motor assembly must always be changed out. Two kits cover this change out conversion. Kit KCBBA00TG covers the conversion of Coleman 00B, 00C, 00/D, /D, C, DGRT and DLRS series, Intertherm MGHA, and Miller MMHA in -/-, -, -/-, and -ton gas furnaces. Kit KCBBA00TG covers the conversion of Coleman 00B, 00C, 00/D, /D, C, DGRT and DLRS series, Intertherm MGHA, and Miller MMHA in gas furnaces above tons. SAFETY CONSIDERATIONS Installing and servicing heating equipment can be hazardous due to gas and electrical components. Only trained and qualified personnel should install, repair, or service heating equipment. Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel. When working on heating equipment, observe precautions in the literature, tags, and labels attached to or shipped with the unit and other safety precautions that may apply. Follow all safety codes. In the United States, follow all safety codes including the National Fuel Gas Code NFPA No. -/ANSI Z.-. In Canada, refer to the current edition of the National Standard of Canada CAN/CGA- B.- and.-m Natural Gas and Propane Gas Installation Codes. Wear safety glasses and work gloves. Have fire extinguisher available during start-up, adjustment, and service call procedures. Recognize safety information. This is the safety-alert symbol alert to the potential for personal injury.. When you see this symbol on the furnace and in instructions or manuals, be Understand the signal word DANGER, WARNING, or CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard that could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. WARNING: Before installing or servicing system, always turn off main power to system. There may be more than disconnect switch. Turn off accessory heater power if applicable. Electrical shock can cause personal injury or death. DESCRIPTION AND USAGE Kits KCABBA00TG and KCABB00TG are comprehensive kits containing a blower motor assembly, control box assembly, adapter frame, and a parts bag. Installation of components is determined by unit of application. The installation instruction is composed of sections covering specific units and sizes.. Section covers the installation of KCBBA00TG into Coleman 00B, 00C, 00/D, /D, C, DGRT and DLRS series -/-, -, -/-, and -ton gas furnaces.. Section covers the installation of KCBBA00TG into Coleman 00B, 00C, 00/D, /D, C, DGRT and DLRS series gas furnaces above tons.. Section covers the conversion of -/-, -, -/-, and -ton Intertherm MGHA and Miller MMHA Series Gas Furnaces using kit KCBBA00TG and the conversion of units above -ton using kit KCBBA00TG. INSTALLATION SECTION This section covers the installation of KCBBA00TG into Coleman 00B, 00C, 00/D, /D, C, DGRT and DLRS series -/-, -, -/-, and -ton gas furnaces. REMOVE BLOWER FROM CARN. Remove blower from carton. Unit is heavy so exercise care when handling.. Straighten any flanges bent during shipment.. Remove cardboard packing from blower wheel. Form: AG-CBBA-0 Cancels: AG-CABA-0, AG-CAWH-0 Printed in U.S.A. 0- Catalog No. -CB-BA

. Check rotation of blower wheel in housing. If any rubbing occurs between blower wheel and housing, adjust blower wheel on motor shaft by loosening blower wheel setscrew and sliding wheel along shaft until rubbing stops.. Check blower wheel setscrew for tightness. When tightening setscrew, be sure screw is on flat side of motor shaft.. Check control box and wiring harnesses for shipping damage. File claim with shipper if shipment is damaged or incomplete. REMOVE EXISTING BLOWER FROM FURNACE. Turn electrical power at main electrical service entrance to OFF position.. Remove furnace door.. Unplug motor connector plug from receptacle on furnace control box by pinching clasping tabs on sides of plug and pulling plug straight up from receptacle.. Remove blower mounting screws, then remove blower from front of furnace. Retain screws for new blower installation. INSTALL KCBBA00TG BLOWER ASSEMBLY AND CONTROL BOX A. Mount Control Box and Adapter Frame to Blower. Remove cover from blower control box by removing screw. Retain screw for reinstallation.. Mount control box cover on blower wrapper using No. 0 X /-in. screws. (See Fig..). Install adapter frame to blower housing using No. 0 X /-in. screws. (See Fig..). Mount control box to cover on blower with screw removed in Step above. (See Fig..) Make sure bottom of cover engages inside of control box flange. B. Install Blower Into Unit. Start blower rail flanges into blower slots and push blower into furnace until mounting bracket flange is against furnace. (See Fig..). Secure blower with screws removed earlier in Procedure, Step. Attach blower ground lead under screw in blower compartment that contacts an unpainted surface. C. Connect Wiring Harnesses. Connect -pin plug of -in. wiring harness (supplied) to blower control box receptacle. (See Fig..). Connect -pin plug of -in. harness to furnace control box receptacle. (See Fig..). Connect -pin receptacle of -in. harness to -pin plug of -in. wiring harness. (See Fig..). Connect -pin plug of blower wiring harness to blower control box receptacle. (See Fig..) A. 00B Series Furnace MODIFY FURNACE CONTROL BOX WIRING. Remove /-in. knockout on furnace control box.. Remove furnace control box cover.. Run loose red wire (supplied) from R of low-voltage terminal board on blower control box through knockout hole in furnace control box. (See Fig. and.). Run loose blue wire from -pin receptacle of -in. wiring harness through knockout hole in furnace control box.. Install strain relief to wires and snap into knockout hole of furnace control box.. Remove gray wires from low-voltage connection of transformer. Cut terminals off and strip wires / in. Twist ends of gray wires and red wire together and secure with wire nut provided. (See Fig..). Remove yellow wires from low-voltage connection of transformer. Cut terminals off and strip wires / in. Twist ends of yellow wires and blue wire (of -pin receptacle through knockout) together and secure with wire nut provided. (See Fig..). Replace furnace control box cover. B. 00C, C, 00/D, /D, DLRS, and DGRT Series Furnace. Remove /-in. knockout on furnace control box.. Remove furnace control box cover.. Run loose blue wire from -pin receptacle of -in. wiring harness through knockout hole in furnace control box. (See Fig. and Fig.,,, or.). Install strain relief to wire and snap into knockout hole of furnace control box.. For 00C, C, 00/D, and /D remove yellow wires from low-voltage connection of transformer. Cut terminals off and strip wires / in. Twist ends of yellow wires and blue wire (or -pin receptacle through knockout) together and secure with wire nut provided. (See Fig.,, or.)

BLOWER ASSY CONTROL BOX COVER ADAPTER FRAME Fig. Blower Assembly A CONTROL BOX ASSY BLOWER ASSY ADAPTER FRAME Fig. Blower Assembly Installation A

. For DLRS and DGRT series furnaces, remove of the low-voltage connections of transformer. A gray and a yellow wire should be removed leaving the third yellow wire connected to the transformer. That is the yellow wire that goes to the reignitor module. Cut terminals off and strip the wires / in. Twist ends of yellow, gray and blue wire (or -pin receptacle through knockout) together and secure with wire nut provided. (See Fig..). Replace furnace control box cover. CONNECT THERMOSTAT A. Heating Only Thermostat ( wire). Connect thermostat wires W to W of low-voltage terminal board on blower control box.. Series variation a. For 00B Series: connect thermostat R terminal to loose red wire from -pin plug of -in. harness. (See Fig..) b. For 00C, C, 00/D, /D, DLRS, and DGRT Series: tape loose end of red wire from -pin plug of -in. harness, and connect thermostat wire R to R on low-voltage terminal board. (See Fig..). Remove locking clip on HEAT/COOL switch on blower control box. (See Fig. or.). Explain to homeowner that HEAT/COOL switch must be manually set in appropriate position for heating or cooling.. Turn ON-OFF switch on furnace junction box to ON position. B. Heat/Cool Thermostat ( wire). Connect thermostat wires W and Y to W and Y, respectively, of low-voltage terminal board on blower control box.. Series variation a. For 00B Series: connect thermostat R terminal to loose red wire from -pin plug of -in. harness. (See Fig..) b. For 00C, C, 00/D, /D, DLRS, and DGRT Series: tape loose end of red wire from -pin plug of -in. harness, and connect thermostat wire R to R on low-voltage terminal board. (See Fig..) NOTE: Do not remove locking clip from HEAT/COOL switch.. Turn ON-OFF switch on furnace junction box to ON position. C. Heat/Cool Thermostat ( wire). Remove external jumper wire from G and Y of low-voltage terminal board on blower control box.. Connect thermostat wires W, Y, and G to W, Y, and G, respectively, of low-voltage terminal board on blower control box.. Series variation a. For 00B Series: connect thermostat R terminal to loose red wire from -pin plug of -in. harness. (See Fig..) b. For 00C, C, 00/D, /D, DLRS, and DGRT Series: tape loose end of red wire from -pin plug of -in. harness, and connect thermostat wire R to R on low-voltage terminal board. (See Fig..) NOTE: Do not remove locking clip from HEAT/COOL switch.. Turn ON-OFF switch on furnace junction box to ON position. CONNECT CONDENSING UNIT Connect condensing unit control relay or contactor to Y and C on blower low-voltage terminal board on blower control box. COMPLETE UNIT INFORMATION PLATE Using ballpoint pen, complete information requested on information plate. Peel backing off plate and affix in upper right-hand corner of vestibule panel. COMPLETE UNIT INSTALLATION. For -wire thermostats only: Remember to explain to homeowner that HEAT/COOL switch must be manually set to appropriate position.. Replace furnace door.. Restore power to unit.. Cycle furnace in both heating and cooling modes to ensure proper operation. SERVICE A qualified service person should clean and lubricate the blower unit each heating and cooling season. Clean the blower unit when cooling coil is cleaned. Lubricate motor every years if motor is used intermittently, or every years if motor is in continuous operation. Remove motor to lubricate. Place approximately drops of SAE 0 non-detergent oil in oil port. Plug port securely. Check electrical connections for tightness and controls for proper operation each heating and cooling season. Service as necessary.

LOCKING CLIP HEAT/COOL BLOWER CONTROL BOX -IN. WIRING HARNESS -IN. WIRING HARNESS PIN PIN RWGYC LOW VOLTAGE TERMINAL BOARD PIN / GND BLOWER ASSY E PIN EXISTING CONTROL BOX STRAIN RELIEF R OF THERMOSTAT Fig. Coleman 00B Wiring Layout A INSTALLATION SECTION This section covers the installation of KCBBA00TG into Coleman 00B, 00C, 00/D, /D, C, DGRT and DLRS series gas furnaces above tons. REMOVE BLOWER FROM CARN. Remove blower from carton. Unit is heavy so exercise care when handling.. Straighten any flanges bent during shipment.. Remove cardboard packing from blower wheel.. Check rotation of blower wheel in housing. If any rubbing occurs between wheel and housing, adjust blower wheel on motor shaft by loosening blower wheel setscrew and sliding wheel along shaft until rubbing stops.. Check blower wheel setscrew for tightness. When tightening setscrew, be sure screw is on the flat side of motor shaft.. Check control box and wiring harnesses for shipping damage. File claim with shipper if shipment is damaged or incomplete. REMOVE EXISTING BLOWER FROM FURNACE. Turn electrical power at main electrical service entrance to OFF position.. Remove furnace door.. Unplug motor connector plug from receptacle on furnace wiring box by pinching clasping tabs on sides of plug and pulling plug straight up from receptacle.. Remove blower mounting screws, then remove blower from front of furnace. Retain screws for new blower installation. A. Install Blower Into Unit INSTALL KCBBA00TG BLOWER ASSEMBLY AND CONNECT WIRING. Start blower rail flanges into blower slots and push blower into furnace until mounting bracket flange is against furnace. (See Fig..). Secure blower with screws removed earlier in Procedure, Step. Attach blower ground lead under screw in blower compartment that contacts an unpainted surface. B. Connect Wiring Harnesses. Connect -pin plug of -in. wiring harness, supplied in kit, to blower control box receptacle. (See Fig..). Connect -pin plug of -in. harness to furnace control box receptacle. (See Fig..). Connect -pin receptacle of -in. harness to -pin plug of -in. wiring harness. (See Fig..)

LOCKING CLIP HEAT/COOL BLOWER CONTROL BOX -IN. WIRING HARNESS -IN. WIRING HARNESS PIN PIN RWGYC LOW VOLTAGE TERMINAL BOARD PIN / GND BLOWER ASSY E PIN EXISTING CONTROL BOX STRAIN RELIEF ELECTRICAL TAPE Fig. Coleman 00C, C, /D, DLRS, and DGRT Wiring Layout A. Connect -pin plug of blower wiring harness to blower control box receptacle. (See Fig..) A. 00B Series Furnace MODIFY FURNACE CONTROL BOX WIRING. Remove /-in. knockout on furnace control box.. Remove furnace control box cover.. Run loose red wire (supplied) from R of low-voltage terminal board on blower control box through knockout hole in furnace control box. (See Fig. and.). Run loose blue wire from -pin receptacle of -in. wiring harness through knockout hole in furnace control box.. Install strain relief to wires and snap into knockout hole of furnace control box.. Remove gray wires from low-voltage connection of transformer. Cut terminals off and strip wires / in. Twist ends of gray wires and red wire together and secure with wire nut provided. (See Fig. and.). Remove yellow wires from low-voltage connection of transformer. Cut terminals off and strip wires / in. Twist ends of yellow wires and blue wire (of -pin receptacle through knockout) together and secure with wire nut provided. (See Fig..). Replace furnace control box cover. B. 00C, C, 00/D, /D, DLRS, and DGRT Series Furnace. Remove /-in. knockout on furnace control box.. Remove furnace control box cover.. Run loose blue wire from -pin receptacle of -in. wiring harness through knockout hole in furnace control box. (See Fig. and Fig.,,, or.). Install strain relief to wire and snap into knockout hole of furnace control box.. For 00C, C, 00/D, and /D remove yellow wires from low-voltage connection of transformer. Cut terminals off and strip wires / in. Twist ends of yellow wires and blue wire (or -pin receptacle through knockout) together and secure with wire nut provided. (See Fig.,, or.)

() ON FURNACE CONTROL BOX (L) GRAY GRAY SWICH MANUAL RESET GRAY BLOWER CONTROL (MARKED VAC) FROM BLOWER CONTROL BOX LVTB MARKED R PIN PIN POWER CORD (L) LOAD V LINE 0V LINE 0V LOAD V FROM PIN INCH WIRING HARNESS GAS VALVE (TR) BLOWER CONTROL (COMMON) 00B SERIES. For DLRS and DGRT series furnaces, remove of the low-voltage connections of transformer. A gray and a yellow wire should be removed leaving the third yellow wire connected to the transformer. That is the yellow wire that goes to the reignitor module. Cut terminals off and strip the wires / in. Twist ends of yellow, gray and blue wire (or -pin receptacle through knockout) together and secure with wire nut provided. (See Fig..). Replace furnace control box cover. CONNECT THERMOSTAT A. Heating Only Thermostat ( wire). Connect thermostat wires W to W of the low-voltage terminal board on blower control box.. Series Variation a. For 00B Series: connect thermostat R terminal to loose red wire from -pin plug of -in. harness. (See Fig..) b. For 00C, C, 00/D, /D, DLRS, and DGRT Series: tape loose end of red wire from -pin plug of -in. harness, and connect thermostat wire R to R on low-voltage terminal board. (See Fig..). Remove locking clip on HEAT/COOL switch on blower control box. (See Fig. or.). Explain to homeowner that HEAT/COOL switch must be manually set in appropriate position for heating or cooling.. Turn ON-OFF switch on furnace junction box to ON position. B. Heat/Cool Thermostat ( wire). Connect thermostat wires W and Y to W and Y, respectively, of low-voltage terminal board on blower control box.. Series Variation a. For 00B Series: connect thermostat R terminal to loose red wire from -pin plug of -in. harness. (See Fig..) b. For 00C, C, 00/D, /D, DLRS, and DGRT Series: tape loose end of red wire from -pin plug of -in. harness, and connect thermostat wire R to R on low-voltage terminal board. (See Fig..) NOTE: Do not remove locking clip from HEAT/COOL switch.. Turn ON-OFF switch on furnace junction box to ON position. C. Heat/Cool Thermostat ( wire). Remove external jumper wire from G and Y of low-voltage terminal board on blower control box.. Connect thermostat wires W, Y, and G to W, Y, and G, respectively, of low-voltage terminal board in blower control box.. Series Variation Fig. Coleman 00B Wiring From Transformer A

() ON FURNACE CONTROL BOX (L) PIN PIN PIN LOAD V LINE 0V LINE 0V LOAD V POWER CORD (L) FROM PIN INCH WIRING HARNESS GAS VALVE (TR) DAMPER MOR 00C SERIES DIRECT SPARK IGNITION Fig. Coleman 00C Direct Spark Ignition Wiring From Transformer A a. For 00B Series: connect thermostat R terminal to loose red wire from -pin plug of -in. harness. (See Fig..) b. For 00C, C, 00/D, /D, DLRS, and DGRT Series: tape loose end of red wire from -pin plug of -in. harness, and connect thermostat wire R to R on low-voltage terminal board. (See Fig..) NOTE: Do not remove locking clip from HEAT/COOL switch.. Turn ON-OFF switch on furnace junction box to ON position. CONNECT CONDENSING UNIT Connect condensing unit control relay or contactor to Y and C on blower low-voltage terminal board on blower control box. COMPLETE UNIT INFORMATION PLATE Using ballpoint pen, complete information requested on information plate. Peel backing off plate and affix in upper right-hand corner of vestibule panel. COMPLETE UNIT INSTALLATION. For -wire thermostats only: Remember to explain to homeowner that HEAT/COOL switch must be manually set to appropriate position.. Replace furnace door.. Restore power to unit.. Cycle furnace in both heating and cooling modes to ensure proper operation. SERVICE A qualified service person should clean and lubricate the blower unit every heating and cooling season. Clean cooling coil when blower unit is cleaned. Lubricate motor every years if motor is used intermittently, or every years if motor is in continuous operation. Remove motor to lubricate. Place approximately drops of SAE 0 non-detergent oil in oil port. Plug port securely. Check electrical connections for tightness and controls for proper operation each heating and cooling season. Service as necessary.

() ON FURNACE CONTROL BOX (L) PIN PIN PIN LOAD V LINE 0V LINE 0V LOAD V POWER CORD (L) GRAY FROM PIN INCH WIRING HARNESS SWICH DAMPER MOR DLRS AND DGRT STANDING PILOT WITH REIGNIR Fig. Coleman DLRS and DGRT Standing Pilot Wiring From Transformer A INSTALLATION SECTION This section covers the conversion of -/-, -, -/-, and -ton Intertherm MGHA and Miller MMHA Series Gas Furnaces using kit KCBBA00TG and the conversion of units above -ton using kit KCBBA00TG. REMOVE BLOWER FROM CARN. Remove blower from carton of kit KCBBA00TG or KCBBA00TG. Unit is heavy so exercise care when handling.. Straighten any flanges bent during shipment.. Remove cardboard packing from blower wheel.. Check rotation of blower wheel in housing. If any rubbing occurs between blower wheel and housing, adjust blower wheel position on motor shaft by loosing blower wheel setscrew and adjusting along shaft until rubbing stops.. Check blower wheel setscrew for tightness. When tightening setscrew, be sure screw is on the flat side of motor shaft.. Check control box for shipping damage. File claim with shipper if shipment is damaged or incomplete. NOTE: Use adapter frame and wiring harness supplied. REMOVE EXISTING BLOWER FROM FURNACE. Turn electrical power at main electrical service entrance to OFF position.. Remove furnace door.. Unplug motor connecter plug from receptacle on furnace control box by pinching clasping tabs on sides of plug and pulling plug straight up from receptacle.. Remove blower mounting screws then remove blower from front of furnace. Retain screws for new blower installation. INSTALL KCBBA00TG OR KCBBA00TG BLOWER ASSEMBLY AND CONTROL BOX A. Mount Control Box and Adapter Frame to Blower. Remove cover from blower control box by removing screw. Retain screw for reinstallation.. Mount control box cover on blower wrapper using No. 0 X /-in. screws. (See Fig..)

() ON FURNACE CONTROL BOX (L) PIN PIN PIN LOAD V LINE 0V LINE 0V LOAD V POWER CORD (L) FROM PIN INCH WIRING HARNESS SWICH /D SERIES STANDING PILOT Fig. Coleman /D Standing Pilot Wiring From Transformer A. Mount control box to cover on blower with screw removed in Step. (See Fig..) Make sure bottom of cover engages inside of control box flange.. Install adapter frame to blower housing using No. 0 X /-in. screws supplied in kit KCBBA00TG or KCBBA00TG. (See Fig..) B. Install Blower into Unit. Start blower rail flanges into blower slots and push blower into furnace until mounting bracket flange is against furnace. (See Fig..). Secure blower with screws removed earlier in Procedure, Step. Attach blower ground lead under screw in blower compartment that contacts an unpainted surface. C. Connect Wiring Harnesses. Connect -pin plug of - to -pin wiring harness to blower control box. (See Fig..). Connect -pin plug of - to -pin wiring harness to furnace control box receptacle. (See Fig..). Connect -pin plug of blower wiring harnesses to blower control box. (See Fig..) MODIFY FURNACE CONTROL BOX WIRING. Remove furnace control box cover.. Remove red wire from low-voltage connection of transformer and cut off terminal.. Clip brown wire from low-voltage side of transformer. (See Fig..). Strip / in. of brown and red wires.. Twist end of brown and red wires together and secure with wire nut provided. (See Fig..). Remove black wire from high-voltage side of transformer and cut off terminal.. Locate black wire at fan switch that goes to -pin receptacle of furnace control box and clip at fan switch.. Strip ends / in. each of black wire just removed and black wire removed in Step.. Twist ends of black wires together and secure with a wire nut provided. (See Fig..) 0

() ON FURNACE CONTROL BOX (L) PIN PIN PIN LOAD V LINE 0V LINE 0V LOAD V POWER CORD (L) FROM PIN INCH WIRING HARNESS BOOSTER () DAMPER MOR C SERIES STANDING PILOT Fig. Coleman C Standing Pilot Wiring From Transformer A 0. Tape exposed ends of black and brown clipped wires with electrical tape.. Connect red and white wires of -in. wiring harness to red and white wires of furnace control box, respectively.. Replace furnace control box cover. CONNECT THERMOSTAT A. Heating Only Thermostat ( Wire). Connect thermostat wire R and W to R and W, respectively, of low-voltage terminal board on blower control box.. Remove locking clip on HEAT/COOL switch of blower control box. (See Fig..). Explain to homeowner that HEAT/COOL switch must be manually set in appropriate position for heating or cooling.. Turn ON-OFF switch on furnace junction box to ON position. B. Heat/Cool Thermostat ( Wire). Connect thermostat wires R, W, and Y to R, W and Y, respectively, of low-voltage terminal board on blower control box. NOTE: Do not remove locking clip from HEAT/COOL switch.. Turn ON-OFF switch on furnace junction box to ON position. C. Heat/Cool Thermostat ( Wire). Remove external jumper wire from G and Y of low-voltage terminal board on blower control box.. Connect thermostat wires R, W, Y, and G to R, W, Y, and G, respectively, of low-voltage terminal board on blower control box. NOTE: Do not remove locking clip from HEAT/COOL switch.. Turn ON-OFF switch on furnace junction box to ON position. CONNECT CONDENSING UNIT Connect condensing unit control relay or contactor to Y and C of blower low-voltage terminal board on blower control box. COMPLETE UNIT INFORMATION PLATE Using a ballpoint pen, complete information requested on information plate. Peel backing off plate and affix in upper right-hand corner of vestibule panel.

NOTE: If any of the wire supplied with the furnace must be replaced, it must be replaced with type 0 C min. thermoplastic or it's equivalent. 00B 0 Fig. 0 Coleman 00B Wiring Diagram BR BLOWER 0V TRAN REVERSING RR A R W G Y C ORN ELECTRICAL TAPE CAP FM ALS GROUND SCREW LOAD LINE V SEC 0V PRI V BLOWER CONTROL BLOWER ORN WIRE NUT BRN LIN V TRANS ORN QV COM

00C DIRECT SPARK IGNITION 0 NOTE: If any of the wire supplied with the furnace must be replaced, it must be replaced with type 0 C min. thermoplastic or it's equivalent. Fig. Coleman 00C Direct Spark Ignition Wiring Diagram BR BLOWER 0V TRAN REVERSING RR A R W G Y C ELECTRICAL TAPE FAN CAP FM ALS WIRE NUTS BOOST CONDENSATE COIL BOOSTER MOR DAMPER MOR 0V TRAN V GROUND VALVE GROUND BRN POWER GAS CONTROL ON LE V

TRANS. 00C STANDING PILOT 0 NOTE: If any of the wire supplied with the furnace must be replaced, it must be replaced with type 0 C min. thermoplastic or it's equivalent. Fig. Coleman 00C Standing Pilot Wiring Diagram BR BLOWER 0V TRAN REVERSING RR A0 R W G Y C ELECTRICAL TAPE FAN ORN CAP FM ALS WIRE NUT LINE 0V PRI V SEC DAMPER MOR GROUND SCREW GAS CONTROL LOAD V

TRANS. DLRS AND DGRT STANDING PILOT WITH IGNIR 0 BR BLOWER REVERSING 0V TRAN NOTE: If any of the wire supplied with the furnace must be replaced, it must be replaced with type 0 C min. thermoplastic or it's equivalent. Fig. Coleman DLRS and DGRT Standing Pilot with Ignitor Wiring Diagram A R W G Y C CAP FM ALS ORN WIRE NUT ELECTRICAL TAPE LINE 0V PRI V SEC LOAD FAN DAMPER MOR V PILOT BURNER ELECTRODE GROUND SCREW REIGNIR MODULE GAS CONTROL RR V NOTE: Remove jumper across the G and Y terminals for a -wire thermostat.

TRANS. /D STANDING PILOT 0 NOTE: If any of the wire supplied with the furnace must be replaced, it must be replaced with type 0 C min. thermoplastic or it's equivalent. Fig. Coleman /D Standing Pilot Wiring Diagram BR BLOWER 0V TRAN REVERSING RR A R W G Y C ELECTRICAL TAPE FAN ORN CAP FM ALS WIRE NUT LINE 0V PRI V SEC GROUND SCREW GAS CONTROL LOAD V

00/D HOT SURFACE IGNITION Fig. Coleman 00/D Hot Surface Ignition Wiring Diagram A0 NEUTRAL 0V PRI V SEC 0 LINE LOAD NOTE: If any of the wire supplied with the furnace must be replaced, it must be replaced with type 0 C min. thermoplastic or it's equivalent. BR BLOWER 0V TRAN REVERSING RR R W G Y C ELECTRICAL TAPE CAP FAN MANUAL RESET FM ALS BOOST CENTRIFUGAL BOOSTER MOR DAMPER MOR V TH TR GROUND SCREW IGNITION MODULE L S OR IGN S OR IGN L WV OR TR WV OR VALVE TH HOT SURFACE IGNIR BRN BRN GRD SCREW BRN GAS CONTROL NOTE: Incoming power must be polarized. Observe color cooling.

TRANS. STANDING PILOT 0 NOTE: If any of the wire supplied with the furnace must be replaced, it must be replaced with type 0 C min. thermoplastic or it's equivalent. Fig. Coleman C Standing Pilot Wiring Diagram BR BLOWER 0V TRAN REVERSING RR A R W G Y C ELECTRICAL TAPE FAN CAP FM ORN ALS WIRE NUT LINE 0V PRI V SEC DAMPER MOR GROUND SCREW GAS CONTROL LOAD CONDENSATE COIL BOOSTER MOR BOOST V

HEAT/COOL BLOWER CONTROL BOX BLOWER ASSY PIN RWGYC PIN LOW VOLTAGE TERMINAL BOARD LOCKING CLIP AU/FAN/ON PIN EXISTING FURNACE CONTROL BOX Fig. Intertherm MGHA and Miller MMHA Wiring Layout A PIN NEUTRAL FAN ON/OFF L GROUND SCREW WHITE FAN AUX TAPE WHITE PIN TAPE BRN TRANS BRN EXISTING FURNACE CONTROL BOX BRN GAS VALVE Fig. Furnace Control Box Modification A0 COMPLETE UNIT INSTALLATION. For -wire thermostat, position HEAT/COOL switch to appropriate mode. Explain to homeowner that HEAT/COOL switch must be manually set to appropriate position.. For - or -wire thermostats, locking clip should not be removed from HEAT/COOL switch since modes are automatically selected.. Replace furnace door.. Restore power to unit.. Cycle furnace in both heating and cooling modes to ensure proper operation. SERVICE A qualified service person should perform cleaning and lubricating of the blower unit each heating and cooling season. Clean cooling coil when blower unit is cleaned. Lubricate motor every years if motor is used intermittently, or every years if motor is in continuous operation. Remove motor to lubricate. Place approximately drops of SAE 0 non-detergent oil in oil port. Plug port securely. Check electrical connections for tightness and controls for proper operation each heating and cooling season. Service as necessary.

INTERTHERM MGHA AND MILLER MMHA SERIES GAS FURNACES 0 BR 0V TRAN Fig. Wiring Diagram A R W G Y C NEUTRAL L CAP FM SLS WHITE WHITE TAPE TAPE BRN GROUND SCREW FS LS BRN GAS VALVE BRN EXISTING FURNACE CONTROL BOX LS FS SLS FM FAN SECONDARY FAN MOR CAP TRAN BR RR FAN ON/OFF SLS CAPACIR TRANSFORMER BLOWER REVERSING BR RR RR V NOTES:. Incoming power must be polarized. Observe color coding. (See furnace data label for electrical data.). If any of the original wire, as supplied, must be replaced, use 0 C thermoplastic type wire or it's equivalent. -00 0

EXISTING FURNACE CONTROL BOX INTERTHEM MGHA AND MILLER MMHA 0 Fig. 0 Intertherm/Miller Wiring Diagram BR BLOWER 0V TRAN REVERSING RR A R W G Y C CAP FM ORN ALS V TRANS TRANS TRANS TRANS EXISTING EXISTING TRANS TRANS TRANSFORMER TRANS EXISTING FAN FAN/ON/OFF

RESCO P.O. Box, Indianapolis, IN 0 0c Book/Tab: /d /d Catalog No. -CB-BA