Circuit Protector. GCP Series. Features. Electromagnetic Overcurrent Protection. Approvals. AC/DC Dual Voltage. Easily Identified ON/OFF Indicator

Similar documents
Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

MICRO SWITCH GLL Series

V-Basic Standard V15 Series

MICRO SWITCH NT Series

FR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

HIH-4010/4020/4021 Series Humidity Sensors

Intrinsically Safe Transmitters, Option Code 2n

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

MICRO SWITCH NT Series

HIH-4030/31 Series Humidity Sensors

HIH-5030/5031 Series Low Voltage Humidity Sensors

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

HIH-4000 Series Humidity Sensors

HIH-4602-L Series Humidity Sensors

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

Potential Applications

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified


Micropower Omnipolar Digital Hall-Effect Sensor ICs

Issue 1. MICRO SWITCH Rocker Switches TP Series. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS PORTFOLIO VALUE TO CUSTOMERS

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

Installation Instructions for the

MICRO SWITCH BAF/DTF Series

General Purpose Industrial VRS Magnetic Speed Sensors

Guide to Hazardous Location Approvals:

Wireless Panel-Mount Monitor

Installation Instructions for the

Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

HOA6480 Series Barcode Sensor Infrared Products

High Temperature Industrial VRS Magnetic Speed Sensors

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

MICRO SWITCH GSX Series

MICRO SWITCH V15W Series Watertight Miniature Switches

Quick Start Guide for the Limitless Series WGLA Limit Switch used in conjunction with the Limitless WPMM Series ISSUE WARNING

HFX Fiber Optic Component 50 Mbps, 650 nm LED

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

1HP Series. Aerospace-Grade Pressure Switch High Pressure Series. precise, demanding requirements of aerospace and defense applications.

Sensors and Switches in Commercial Traction Elevators

WARNING MISUSE OF DOCUMENTATION

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

Wireless Heavy-Duty Limit Switch with Eyelet-Pull (WLS Series)

Installation Instructions for the 600 Series Optical Encoders

Quadrature Speed and Direction Sensors

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 4. Datasheet

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

Silica, Phosphate, Hydrazine Analyzers Series 2140 Specifications

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 3. Datasheet

Sensor Evaluation Kit, SEK001

MICRO SWITCH E6/V6 Series

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

900 ControlEdge Remote Termination Panel (RTP) For Relay Outputs

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

Interactive Catalog Replaces Catalog Pages

AMR 4-Pin Quadrature Sensor Integrated Circuit

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

FSS-SMT Series. Low Profile Force Sensor

Issue 4. Bipolar Hall-Effect Digital Position Sensor ICs: SS40F, SS40AF. Sensing and Internet of Things. Datasheet

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

HIH-4602 A & C Series.

FEATURES AND BENEFITS

LCZ Series Hall-effect Zero Speed Sensors

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

MICRO SWITCH Basic Switches Line Guide

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

Issue B. Bipolar Hall-Effect Digital Position Sensor ICs: SS41, SS41-L, SS41-T2, SS41-T3, SS41-S, SS41-SP. Sensing and Internet of Things

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Fiber Optics and Liquid Level Sensors Line Guide

MICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet

Linear Current Sensors

EMERGENCY STOP NEEDS 2015 CATALOG

FF-ST4 Series. Type 4 Safety Light Curtains. Potential Applications. Features

TruStability Board Mount Pressure Sensors

Airflow Sensors Line Guide

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

MICRO SWITCH BX/BX2 Series

DESCRIPTION FEATURES WARNINGS APPLICATIONS

High Sensitivity Latching Digital Hall-effect Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-T3 SS460S-LP

Molded Case Circuit Breakers, Bulletin 140G

CM Series. 2D Imager Modules. Compact 2D Imager Module for Kiosk Data Capture Operations FEATURES & BENEFITS DIFFERENTIATION VALUE TO CUSTOMERS

High Sensitivity Latching Digital Hall-effect Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP

* Consult factory on conditions for approval acceptability

Hydrazine Analyzer Series 2171 Specifications

Transcription:

Circuit Protector GCP Series Features Electromagnetic Overcurrent Protection Overcurrent is prevented by an electromagnet, which is more appropriate and effective for circuit protection than the thermostatic method (bimetal). AC/ Dual Voltage AC/ dual voltage, it can be used up to AC250V/60V (Singlepole), and 120V (Double-pole). Compact Size 17.5mm width per 1 pole, subcompact size compared to general circuit breakers. It requires less space for multiple units being installed. Optional Auxiliary Switch The auxiliary switch function allows to check for operating trip by connecting with a buzzer or lamp. Approvals GCP series is not only KC-certified (Korea) but also internationally recognized with its UL, CE, TUV, PSE, and CCC certifications. (UL No.E241678, CE/TUV No.N8 13 06 44033 020, PSE No.JET6977-42010-1001:1006, CCC certification to be completed by the end of 2013) Easily Identified / Indicator / indications are clearly visible even from a distance and ideal for control panel application. The trip handle is designed to prevent malfunction at a slight touch. Easy Installation & Maintenance Compliance with the IEC standard, DIN rail mounting makes installation and removal easier than ever. Safe Design for Secure Insulation The terminal part is protected by walls to prevent the wiring from being exposed. A cover is incorporated to enhance shock safety. Others High vibration resistance (15G) and shock resistance (50G) Label discoloration prevented by laser marking Rated breaking capacity AC/ 1,500A (KC: 2,500A) 3D drawing (3D model file) provided Honeywell Sensing and Control 1

Specifications Model GCP-31AN GCP-32AN GCP-33AN Appearance (DIN-rail mounting) Rated breaking capacity No. of poles Single Double Triple Rated voltage AC250V/60V AC250V/120V AC250V Note 1) Rated current 0.1A, 0.3A, 0.5A, 1A, 2A, 3A, 5A, 7A, 10A, 15A, 20A, 25A, 30A Weight 77g 150g 220g Insulation resistance UL1077 CCC GB17701 PSE CE EN60934 IEC60934 KC K60934 100M Ohm min (500V insulation resistance tester) AC 250V 1.5KA 60V 1.5KA - 120V - 1.5KA AC 220V 2.5KA Reference ambient temperature Operating ambient temperature Terminal 60V 2.5KA - 120V - 2.5KA +40 C -10 ~ +60 C Permitted relative humidity 0 ~ 85% Operating type Body Auxiliary switch Mounting Dielectric voltage Vibration resistance Shock resistance Endurance Accessories Approvals KC certification (Korea) Instantaneous (I), Medium Speed (M) M4 screw (25A or below): 1.2~1.5Nm, M5 screw (30A): 1.8~2.2Nm M3 screw: 0.8~1.0Nm IEC 35mm rail and M4 screw AC1500V (50/60Hz) for 1 min 15G (147m/S²), IEC60068-2-6 50G (500m/S²), IEC60068-2-27 10,000 times (mechanical); 6,000 times (electrical) Auxiliary switch (AX) IEC60934, K60934, UL1077, GB17701 JH02039-13001 CE certification (Europe) N8 13 06 44033 020 UL certification (US) PSE certification (Japan) E241678 JET6977-42010-1001:1006 CCC certification (China) To be certified in 2013 Note 2) Note 1) The triple-pole product is for AC only, not for. Note 2) CCC certification to be completed by the end of 2013. Note 1) Note 1) Honeywell Sensing and Control 2

Model Selection Guide GCP-3 X AN X XXXX XX Model Name GCP-3 No. of poles Single 1 Double극 2 Triple극 3 Connection Standard DIN rail Operating Medium Speed M Instantaneous I Rated current 0.1A 7A 0.3A 10A 0.5A 15A 1A 20A 2A 25A 3A 30A 5A Standard Auxiliary switch Accessories AX Example 1) GCP-3 circuit protector; single-pole with DIN rail; Medium Speed; standard type of 3A rated current - GCP-31ANM3A Example 2) GCP-3 circuit protector; double-pole with DIN rail; Medium Speed; auxiliary switch type of 0.5A rated current - GCP-32ANM0.5AAX Characteristic Curve for Trip Medium Speed Instantaneous (hr) (min) 2h 1h 30min 20min 10min 6min 4min AC (hr) (min) 1h 40min 20min 10min 6min 4min AC 2min 2min 1min 1min Operating time 30sec 20sec 10sec 5sec 2sec Max Operating time 30sec 20sec 10sec 5sec 2sec (sec) 1sec (sec) 1sec 0.5sec 0.5sec 0.2sec 0.1sec 0.05sec Min 0.2sec 0.1sec 0.05sec Max 0.02sec 0.01sec 0.02sec 0.01sec Min 0.006sec 0.006sec 1 1.25 2 3 4 5 7 10 20 50 100 1 1.25 2 3 4 5 7 10 20 50 100 Current (multiples of rated current) Current (multiples of rated current) Honeywell Sensing and Control 3

Temperature Compensation Curve The operating time for the Medium Speed (M) type is measured at the ambient temperature of 40 C. Refer to the ambient temperature compensation curve before use for the operating time for any other temperature range. The Instantaneous (I) type is not affected by the ambient temperature. Rated current change (%) Ambient temperature [ C] Rated Current Ratio by Mounting Position It appears that the operating current is 90% or 110% depending on the mounting position. Correct the rated current before use by referring to the figures below. Vertical Horizontal Reverse vertical Reverse horizontal 100% 110% 100% 90% Vertical mounting (general) Reverse vertical mounting Din Rail Din Rail Honeywell Sensing and Control 4

External Dimensions [Unit: mm] General Type Single-pole Double-pole Triple-pole AX Type Single-pole Double-pole Triple-pole Hole Dimensions 12.0 54.0 2-M4 29.5 54.0 2-M4 47.0 54.0 2-M4 Single-pole Double-pole Triple-pole Honeywell Sensing and Control 5

GCP Series Circuit Protector Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING PERSAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Honeywell 5F, Sangam IT Tower 1590, Sangam-dong, Mapo-gu, Seoul, 121-835, Korea Phone: +82-2-799-6097 Fax: +82-2-792-9013 E-mail: scinfo@honeywell.com http://www.honeywell.co.kr/acs/sc Copyright September 2013 Honeywell Co., Ltd. All rights reserved.