Humidity Meters HUMIDITY METERS. hygrometers & therma-hygrometers. what is a hygrometer? applications. monitor humidity levels for better health

Similar documents
hvgrometers Humidity Meters humidity meters hygrometers & therma-hygrometers what is a hygrometer? applications

Humidity Meters. hygrometers & therma-hygrometers. what is a hygrometer? applications. monitor humidity levels for better health. Humidity.

Instruments. for hydroponics & horticulture 2016

Thermometers. for home & garden specialists in temperature measuring equipment for over 30 years

Thermometers. for home & garden specialists lit in temperature t measuring equipment for 35 years

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Thermo-/Hygrometer with Mould Alert Model WS 1500 Operating Manual

Indoor/Outdoor Temperature Alert

Fridge Freezer Thermometer for Internal Temperature

Measurement that works. Extra info deals Puja Engineering. Catering& Food Processors Thermometers

Wet Bulb Thermo-Hygrometer Datalogger

USER GUIDE Heat Index Psychrometer

Thermometers. for foodservice & industry

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

TOOLS AND INSTRUMENTS

INSTRUCTION MANUAL for WS 9420 Digital COMFORT INDEX Thermometer-Hygrometer with Mold Alert and Dew Point Temperature P. 1

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Manual Vane Anemometer PCE-VA 20

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

CALIBRATABLE 7-FUNCTION THERMO- HYGROMETER USER S MANUAL

Comark Instruments. Measuring and monitoring temperature within healthcare and industry. The Professionals Choice

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

HUMIDITY IN INCUBATION

USER GUIDE. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester. Model VFM200

Pressure measuring instruments

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

Soil Moisture Probe. Frizzell ltd. Owners Manual And Reference. Model SMP3A. frizzell ltd. Box 32 Kirwee Canterbury, 7543 New Zealand Ph:

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Model ST-128M Moisture Detector

Using the DewTrak II Dew Point/ Humidity Transmitter

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

108A OTP1800. Grid Support. General Description

9-IN-1 THERMO-HYGROMETER/ MOISTURE METER USER S MANUAL

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

EL-OEM-3 OEM Packaged Voltage Data Logger

Humidity Measurement Technology pros & cons. Helping you make a better measurement.

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Manual Hygrometer PCE-555

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

QUICK START. FLIR Model MR59. Ball Probe Moisture Meter with Bluetooth

OILTESTER - Deep-frying Oil Tester. Instruction manual

Advance Humidity Pump with Octagon 20 and 40 Advance EX Upgrade

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Selecting the right humidity sensor for your application

Using the Model 1500 Portable Chilled Mirror Hygrometer

BC-HTO RELIABLE SENSING TECHNOLOGY

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

Registered address: 7 Drakes Drive, Crendon Business Park Long Crendon, HP18 9FE

WIRELESS THERMO-HYGROMETER Instructions manual Cat. No. WS9070IT+

COA-2010-F Electronic CO 2

Concise catalogue Water-Industry

Introduction. OM-THA2

Thermohygrometer with Single Type K Input and Superheat Function

UC152 and US152. Key Features. Hotplate with Stirrer, UC152 US152. Technical Specification. Ordering Information

Perfect for testing. Perfect for service. The testo Smart Probes Air Conditioning set. The testo 550/557 digital manifolds.

THERMAX Efficiency Monitor

HydroMaster USER S GUIDE HM-500

CO warning instruments and gas spillage detectors

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

CALIBRATABLE 3-FUNCTION THERMO- HYGROMETER USER S MANUAL

PERSONAL COMBUSTIBLE GAS DETECTOR

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

MLTXD16 Temperature Datalogger with Internal and External Sensor. Accuracy & Resolution ±0.3 C avg res. 0.5 C Storage Temperature -40/85 C

Infrared Moisture Balance (FD-660)

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

User's Guide. Pinless Moisture Meter. Model MO257

JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD ARJONS DR., SUITE C P.O. BOX LINKOU-117

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

MR SERIES CARD LOGGERS

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

MicroRay IR-100 NEW. Inspection MicroRay IR-100

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

WIRELESS FRIDGE THERMOMETER Instruction Manual

DEW POINT HYGROMETER MODEL DPH-2020/2012 BULLETIN DPH-2020/2012 can be used to extend the lower measurement limit of the system.

DP 300 mobile dew point instrument

VASTHI ENGINEERS. Vasthi Explosive Meter Sheet No. 1 of 5. Vasthi Monitors for Combustible Gas.

SENSORS TRANSMITTERS. Process monitoring

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Digital, not analog: One manifold for all refrigeration systems.

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

HTG79 Operating Instructions

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

EVac II Programmable Digital Vacuum Gauge

Refrigerator/Freezer Thermometer

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

OEM Alpha Thermostat direct Analog

Software Version 2.01 LEVEL MONITOR MODEL 220

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Pocket Moisture Meter Instruction Manual

ST Wiring diagram. Product description. Standard temperature controller. Order number

DT-123/125/127/129 P107. Moisture meters DT-8851/8852 P109. Sound Level Meter DT-8894 P113. Thermo-Anemometer with IR temperature DT-8890/8890A P119

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

Transcription:

HUMIDITY METERS Humidity Meters hygrometers & therma-hygrometers In many manufacturing processes the measurement of relative humidity () is important, as many products are sensitive to variations in humidity. Therefore humidity needs to be measured and controlled for the end products to be consistent in both quality and performance. what is a hygrometer? A hygrometer is an instrument used to measure the quantity of water vapour present in air. Hygrometers can measure relative humidity over the range of 0 to 100 but in most instruments, this range may be more limited depending on the sensor type. Relative humidity is expressed as the ratio of the amount of water vapour present in the air or gas, to the quantity which would reach saturation, saturation being 100 %. applications There are a wide range of applications for measurement in the following industries: pharmaceutical livestock electronic component production paper mills food processing computer rooms The pharmaceutical industry is one of the largest users of humidity instrumentation as products can be sensitive to variations in humidity levels. Food manufacturing processes rely on humidity control, as food preservation techniques are often focused on limiting the activity of water. The humidity is an essential element of climate control in buildings for optimum comfort and energy conservation. Paper and paper based products are highly sensitive to humidity and moisture levels. During production, storage and distribution, the monitoring of humidity can have significant benefits on quality. monitor humidity levels for better health If a building is too damp and the humidity level is too high at above 70, not only does mould develop but it can encourage dust mites to breed in carpets and mattresses. Conversely, if the humidity level is too low at below 25, it can cause respiratory discomfort. The regular monitoring of humidity levels in buildings can improve health. dew point The dew point is defined as the lower temperature to which air must be cooled in order for condensation (saturation) to occur. The dew point is dependent on the concentration of water vapour () present. UKAS Certificates of Calibration Our in-house UKAS calibration laboratory offers certification for both temperature and humidity instruments. Each certificate indicates deviations from standards at five temperature or humidity check points. 100

6000 Series s dew point calculation & max/min function remote or integral & temperature probe s max/min humidity or temperature optional backlit The 6000 series therma-hygrometers are easy to use relative humidity and air temperature measuring instruments. The units measure over the range of 0 to 100 with a resolution of 0.1 and temperature over the range of -20 to 70 C (-20 to 50 C with a fixed probe) with a resolution of 0.1. The therma-hygrometers incorporate a clear custom LCD with C,, max/min, hold and dew point indication. There is an automatic of both open circuit and low. The 6000/6100 the temperature and humidity at the push of a button separately whereas the 6002/6102 humidity and temperature simultaneously and additionally incorporate a backlit. All units are powered by three AAA batteries with a minimum life expectancy of. An auto-power off facility turns the therma-hygrometer off automatically after ten minutes, maximising. HUMIDITY METERS 6100/6102 therma-hygrometers with remote probe These therma-hygrometers utilise an interchangeable probe that incorporates a one-metre lead with a 6-pin Lumberg connector. If the probe needs to be replaced, the instrument will not require re-calibration as the probes are fully interchangeable. 0601 UKAS Calibration Certificate An optional 3-point UKAS Humidity Calibration Certificate is available at a preferential price, when purchased with these therma-hygrometers. DEW POINT HOLD AUTO OFF 224-600 6000 therma-hygrometer 224-610 6100 therma-hygrometer 224-602 6002 therma-hygrometer 224-612 6102 therma-hygrometer 830-227 protective silicone boot - black 224-615 6100/6102 spare probe 890-111 *UKAS 3-point Certificate *price when purchased with a new instrument range -20 to 50/70 C 0 to 100 resolution 0.1 0.1 accuracy ±1 C ±1 digit* ±2 % (10 to 90 ) sensor type silicone bandgap capacitance polymer 3 x minimum 5 years () 12 mm LCD 25 x 56 x 128 mm 130/160 grams *accuracy ±0.4 C over the range 0 to 40 C otherwise ±1 C 101

HUMIDITY METERS 6500 measures humidity & air temperature dew point calculation & max/min function remote & temperature probe The 6500 therma-hygrometer measures both relative humidity and air temperature. The instrument s over the range of 0 to 100 with a resolution of 0.1 and temperature over the range of 20 to 70 C with a resolution of 0.1 C. The unit incorporates a clear custom LCD with C,, max/min, hold and dew point indication. An auto-power off facility turns the therma-hygrometer off automatically after ten minutes, maximising. The 6500 therma-hygrometer incorporates four, easy to use, push buttons allowing the user to select on/off,, max/min and mode functions. Each unit is supplied with a remote sensor and integral PVC lead. 224-655 6500 therma-hygrometer 830-227 protective silicone boot - black 890-111 *UKAS 3-point Certificate *price when purchased with a new instrument DEW POINT HOLD AUTO OFF range -20 to 70 C 0 to 100 resolution 0.1 0.1 accuracy ±1 C ±1 digit* ±3 % (20 to 80 ) sensor type silicone bandgap capacitance polymer & life 3 x - 12 mm LCD 25 x 56 x 128 mm 160 grams *accuracy ±1 C over the range 5 to 45 C otherwise ±1.7 C Hygro-Thermo pen-shaped hygrometer s humidity & temperature max/min memory function The pen-shaped Hygro-Thermo incorporates a large, clear LCD that simultaneously s both humidity and temperature over the range of 20 to 95 and 0 to 49.9 C. The instrument is ideal for monitoring the humidity and temperature in a wide range of applications. Unlike many hygrometers that are large and heavy to carry around, this compact instrument is truly pocket-sized and convenient to use. The Hygro-Thermo incorporates a max/min button which allows the user to the maximum and minimum humidity and temperature simultaneously. The unit is housed in a slim, pen-shaped ABS case measuring 20 x 23 x 138 mm and incorporates a pocket clip. 810-190 pen-shaped Hygro-Thermo range 0 to 49.9 C 20 to 95 resolution 0.1 C 1 accuracy ±1 C ±5 6000 hours custom LCD 20 x 23 x 138 mm 35 grams 102

with comfort level indicator s both humidity & temperature max/min memory function This therma-hygrometer s both the humidity and temperature in addition to indicating and recording the maximum and minimum readings. The unit features an analog arrow indicator and a colour-coded bar to humidity comfort levels e.g. dry, comfort or wet. The instrument measures both humidity and temperature over the range of 0 to 50 C and 10 to 99 utilising the internal sensors. The thermahygrometer is ideal for monitoring both temperature and humidity in rooms, offices, factories and similar to ensure optimum working conditions are maintained. The unit is housed in an ABS case, measuring 20 x 100 x 110 mm, that incorporates a useful foldaway stand and a keyhole slot for hanging on a wall. 810-130 therma-hygrometer - comfort range 0 to 50 C 10 to 99 resolution 0.1 1 accuracy ±1 C ±5 2 x 20 x 100 x 110 mm 150 grams HUMIDITY METERS max/min & alarm functions range of -49.9 to 69.9 C & 20 to 99 integral & remote temperature probe This therma-hygrometer simultaneously s both and recording the maximum and minimum readings. The instrument measures both humidity and temperature over the range of 0 to 49.9 C and 20 to 99 utilising the internal sensors. Utilising the external temperature sensor the temperature range is extended to -49.9 to 69.9 C. The unit features a temperature alert alarm that will sound when the external remote temperature probe indicates the temperature is 0 C or below. This feature is ideal for frost/freeze alert in horticulture and similar. The unit is housed in an ABS case, measuring 20 x 65 x 97 mm, that incorporates a useful foldaway stand and a keyhole slot for hanging on a wall. 810-155 therma-hygrometer - alarm remote probe range -49.9 to 69.9 C 20 to 99 resolution 0.1 1 accuracy ±1 C ±5 20 x 65 x 97 mm 100 grams 103

HUMIDITY METERS ideal for the home, office or factory max/min temperature & humidity function integral & temperature This therma-hygrometer simultaneously s both and recording the maximum and minimum temperature and humidity readings. The hygrometer measures both humidity and temperature over the range of 0 to 50 C and 10 to 99 utilising the internal sensors. This therma-hygrometer is ideal for monitoring both temperature and humidity in rooms, offices, factories and similar to ensure optimum working conditions are maintained. The unit is housed in an ABS case, measuring 20 x 100 x 110 mm, that incorporates a useful foldaway stand and a keyhole slot for hanging on a wall. 810-145 therma-hygrometer range 0 to 50 C 10 to 99 resolution 0.1 1 accuracy ±1 C ±5 20 x 100 x 110 mm 135 grams for panel-mounting s both temperature & humidity easy panel-mounting installation This panel-mounted therma-hygrometer simultaneously s both humidity over the range of 20 to 99 and temperature over the range of 0 to 49.9 C with a resolution of 1 and 0.1 C. This instrument is ideal for OEMs for installing into equipment, i.e. vivariums, egg hatcheries and similar. The therma-hygrometer is easily installed into a panel via a mounting hole with a minimum Ø33 mm cut-out. The unit incorporates a screw clamp with a maximum panel thickness of 7 mm. The therma-hygrometer features a max/min memory function for both temperature and humidity. The unit is powered by a CR2032 coin cell with a life expectancy of 5000 hours continuous use. 810-180 therma-hygrometer - panel C range 0 to 49.9 C 20 to 99 resolution 0.1 C 1 accuracy ±1 C ±5 3 volt CR2032 lithium coin cell 5000 hours Ø50 x 41 mm 42 grams 104

with internal & external probe s both humidity & temperature max/min memory function The therma-hygrometer simultaneously s both and recording the maximum and minimum readings. Using the external remote probe with integrated three metre lead the unit measures both temperature and humidity over the range of -20 to 70 C and 10 to 99. Alternatively using the internal sensor the unit measures temperature over the range of 0 to 50 C. This therma-hygrometer is ideal for monitoring both temperature and humidity in rooms, offices, factories and similar to ensure optimum working conditions are maintained. The unit is housed in an ABS case, measuring 20 x 100 x 110 mm, that incorporates a useful foldaway stand and a keyhole slot for hanging on a wall. 810-140 therma-hygrometer - with probe remote probe range internal 0 to 50 C - range external -20 to 70 C 10 to 99 resolution 0.1 1 accuracy ±1 C ±5 20 x 100 x 110 mm 170 grams HUMIDITY METERS max/min & alarm functions remote & temperature probe 0 C or below audible alert/alarm This therma-hygrometer simultaneously s both and recording the maximum and minimum readings. Utilising the internal sensor the instrument measures temperature over the range of 0 to 49.9 C. The external remote probe with integrated three meter lead measures both temperature and humidity over the range of -49.9 to 69.9 C and 20 to 98. The unit features a temperature alert alarm that will sound when the external remote probe indicates the temperature is 0 C or below. This feature is ideal for frost/freeze alert in horticulture and similar. The therma-hygrometer is housed in an ABS case measuring 18 x 41 x 76 mm, that incorporates a foldaway stand. Each unit is supplied with a probe wall bracket. 810-195 therma-hygrometer - with probe range -49.9 to 69.9 C 20 to 98 resolution 0.1 1 accuracy ±1 C ±3 % at 25 18 x 41 x 76 mm 85 grams 105