Quantum Series Parallel Shaft Fan Drive for Dry Cooling Systems

Similar documents
PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

MARLOW PUMPS RECIRCULATION

SECTION STEAM CONDENSATE PUMPS

Flygt Top-Entry Agitators CONVENIENT AND EFFICIENT

REVERSING DRUM MIXER

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

Dean Pump High Temperature Chemical Process Inline Pumps

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

Full-line Product Overview

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

568X, 587X, 588X Series

侧进式搅拌器. 产品介绍 Product introduction

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

HOMA Pump, Ansonia Connecticut

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

FAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS.

380 Series Multi-Stage Centrifugal Pumps

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Shipboard Electric Water Heater

Shipboard Electric Water Heater

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

TYPE LF/LC/LCV END SUCTION PUMPS

MODEL 664A MODEL 662A MODEL 663A MODEL 661A AURORA. 660 Series SINGLE STAGE SOLIDS HANDLING VORTEX PUMPS

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

Steele Extrusion Machinery

SECTION AIR HANDLING UNIT

PUMPS AND PROP AGITATORS

dualarm Vertical In-Line Pumps

SAM TURBO INDUSTRY LIMITED

Multistage Centrifugal Blowers

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. ASME/ANSI B73.1 Chemical Process Pump

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Selection V 1 INTRODUCTION PAGE V-2 V 2 SUMP/WELL PUMP SELECTION GUIDE PAGE V-3 V 3 CAN PUMP SELECTION GUIDE PAGE V-4

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

1900 Series In-Line Pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

MacroAir AirElite HVLS Fans

Installation, Operation, and Maintenance Manual

Belt Driven Mixed Flow Fans

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8

Multistage Centrifugal Blowers

Vacuum Systems. A complete line of vacuum pumps and accessories for every dairy

WHY SULLAIR? For more information on the IHI-Sullair joint venture, please visit 2,000th IHI-Sullair centrifugal

SECTION WATER-SOURCE UNITARY HEAT PUMPS

Sierra Europe Srlu Technical Specification AL5000 mobile baler

KCC Centrifugal Fan Air Cooled Condensers

JCseries EVAPORATIVE CONDENSER. engineering data

Screw Compressors ESD SERIES. Capacities from: 816 to 1522 cfm Pressures from: 80 to 217 psig

CASE HISTORY#1 BAD COOLING TOWER GEARBOX? Barry T. Cease Cease Industrial Consulting (843)

Horizontal Split Case Pumps Type U

FEATURES. Vacuum Motor. Moving Ahead With Technology

1.1 This section applies to air handling units for HVAC Systems.

A. Codes and Standards that are Standard at the University:

380 Series Multi-Stage Centrifugal Pumps

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

EVMSU - Vertical Multistage Pumps. Product Catalog

Simsite. Impellers and Wear Rings. Improve Longevity & Performance with Simsite Products!

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

CWA4 Chilled & Hot Water Fan Coil

Explosion-Proof Forced Air Unit Heater - XGB

Multistage Centrifugal Blowers

InterSeptor Centrifugal Separators Operating & Maintenance Manual

CUP-CEP. Condensate Extraction, Multi-stage, Bowl Type, Diffuser Pumps

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

SECTION STEAM CONDENSATE PUMPS

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

Explosion-Proof Forced Air Unit Heater - XGB

Goulds Large Capacity, Single Stage, Double Suction Pump

Plenum Fans. Model HPA. Direct Drive

ÉQUIPEMENT DOYON INC. 1255, rue Principale Linière, Qc, Canada G0M 1J0

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

Booster Compressors N Series. Pressures to 650 psig Capacities 9.5 to 724 cfm

Packaged Steam Fired Water Heater

Stationary screw compressors. Catalog #2

Aquatower STEEL COOLING TOWER. engineering data and specifications

Goulds LP3400 Series Low Pulse Fan Pumps

Panel Fan Series Operators Manual (Galvanized and Polymer)

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Family Curve. Submersible Grinder Pumps 1¼" and 2" Discharge. Effluent/Grinder Pumps.

SECTION XXXXX POSITIVE DISPLACEMENT BLOWER WITH SOUNDSEAL COMPACT ENCLOSURE

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

The G.P.I. Max-Air is a non-positive displacement, high volume, low pressure vacuum motor that can operate as a vacuum, compressor or blower.

/ Aquatower Fiberglass Cooling Tower /

Transcription:

Quantum Series Parallel Shaft Fan Drive for Dry Cooling Systems The Quantum Series Parallel Shaft Fan Drive for dry cooling systems reflect a long history of quality workmanship and reliability. Amarillo Gear Company has been designing and manufacturing application specific gear drives since 1934, and the commitment to excellence continues today. One example of this commitment is the availability of complete noise and vibration testing, with all data taken under full power loading, up to 250 hp (186 kw). All fan drives are spin tested prior to shipment and a complete conformity check is made. This ensures that Amarillo supplies the product exactly as required and it will provide reliable service demanded by the owner. Having a parallel shaft fan drive specifically designed for dry cooling systems means the process for selecting the correct fan drive is simple. It s as easy as following the steps shown below. For unusual applications, or extreme operating conditions, contact Amarillo Gear Company for help making the correct selection. Quantum Series Parallel Shaft Fan Drive selection 1. Calculate the required ratio by dividing the motor speed (input) by the desired fan speed (output). 2. Select the fan drive from Table 1 that has a motor power rating, under the required ratio column, that is equal or greater than the motor power at the motor speed. All ratings include an AGMA 2.0 service factor on motor nameplate power which is generally recommended by leading industry designers of Air Cooled Condenser systems for long life and required reliability. Table 1 Service Power Ratings (AGMA Service Factor = 2.0 on motor nameplate power) Horse Power Rating Model Input RPM 18.22 19.27 19.78 20.82 22.02 22.60 Q-500 1750 254 263 250 254 259 250 1500 218 225 214 218 222 214 1200 174 180 172 174 178 172 Kilowatt Power Rating Exact Ratio Vertical Down Thrust Capacity: 10,500 lbs. (47kN) Exact Ratio Model Input RPM 18.22 19.27 19.78 20.82 22.02 22.60 Q-500 1750 189 196 186 189 193 186 1500 162 168 159 162 165 159 1200 130 134 128 130 132 128

The Q-500 Parallel Shaft Fan Drive is designed to ensure that the thermal rating meets or exceeds the service (motor power) rating in Table 1 when the ambient temperature is 120 F or less. No thermal calculations are required. For rare applications where the ambient temperature is above 120 F, contact Amarillo Gear Company for thermal ratings for your specific project conditions. The Quantum Series Parallel Shaft Fan Drive is designed and manufactured specifically for the demanding environment of dry cooling systems. As with any precision machine component, proper selection, installation, maintenance and operating procedures are imperative for long life and trouble-free service. Our engineers will be pleased to assist with unusual conditions that require special procedures, options, or modifications. What To Consider? Ratio All ratios are reducing and defined as the ratio of the input speed to output speed. Exact ratios are noted in Table 1. Special ratios may be available for specific applications. Please contact Amarillo Gear Company for more information. Ratings Amarillo Gear Company recommends a minimum AGMA Service Factor of 2.0 on motor name plate power for gear drives in ACC fan service. The service ratings (motor power rating) noted in Table 1 includes an AGMA service factor of 2.0 on motor name plate power. Ratings are listed for 60 and 50 Hertz electric motor speeds. Ratings at intermediate speeds may be interpolated from the table. Contact the factory for recommendations when the electric motor speed is outside the table range. Design features and ratings are in accordance with, or exceed, the minimum requirements of AGMA (American Gear Manufacturers Association) and CTI (Cooling Technology Institute) standards. Direction of Rotation Normal rotation is both shafts clockwise, when viewed from the top. Occasional use with both shafts rotating counterclockwise is permissible (as long as a non-reverse backstop is not used). Special bearing arrangements are used when the primary direction of rotation is counterclockwise, incurring additional cost, and the fan drives should be ordered accordingly. Quantum Series Standard Features The Quantum Series Parallel Shaft Fan Drive is patent pending and revolutionary in the design of gears for use in ACC s, and provides solutions to common complaints expressed by owners of this type of equipment. The Quantum design is for the owner who seeks to improve the reliability of his rotating equipment and significantly reduce costly repairs and down time. Heat Dissipation The Q-500 fan drive is a power dense compact design incorporating the use of cooling fins for efficient heat dissipation while also providing supreme gear box rigidity.

Housing and Castings Castings are rigidly designed, using finite element analysis, and constructed to absorb internal and external loads with minimum deflection. The gear case is a split case design, with both case and cover doweled together to assure permanent alignment of bearings and gears under load. The interior features a sloped floor that permits complete drainage of oil when a change is required. All casting materials are ASTM A48 Class 30 gray iron for effective damping of noise and vibration. All mating castings are sealed using form-in-place gasket material, eliminating leaks caused by other sealing materials. The Quantum Series has mounting provisions for easy installation of accelerometers for vibration monitoring of each shaft. Mounting feet are predrilled with pilot holes to assist in installation of dowel pins. Helical Gears Amarillo Gear Company manufacturers in house (U.S.A.) the helical gearing for the Quantum Series Parallel Shaft Fan Drive. This allows Amarillo 100% quality control. Helical gears are designed and manufactured from nickel alloy steel. The gears are case hardened to ensure optimum tooth strength and precision ground to a minimum AGMA class Q-11 quality level to provide low-noise, low vibration operation. Quiet Operation Quiet operation of the Quantum Series Parallel Shaft Fan Drive is achieved through careful design and controlled manufacturing methods of all components. Amarillo Gear engineers understand the many parameters that affect gear noise and have applied the latest research to the design of the Quantum Series Parallel Shaft Fan Drive. Rigid shafts and rigid, permanently aligned housings, guarantee precise alignment of gears under load. Test results collected in our on-site test facility prove that our sound levels are among the lowest available in the industry. Please see table on A-Weighted Sound Power for specific data. Efficient Operation and Design The Q-500 parallel shaft fan drive is proven to be 98% efficient under full load. The Quantum series also features efficient design by significantly reducing the number of parts typically found in a parallel shaft gear box thereby contributing to the Quantum s reliability. Bearings All bearings are roller type, sourced from major Tier 1 manufacturers. Bearing spans are maximized for rigidity and increased bearing life. The fan shaft thrust bearing is designed and sized to carry all loads imposed by the fan while maintaining 100,000 L 10 life. All bearings are sized to meet or exceed the minimum life requirements of AGMA and CTI. All bearings are sized to the metric standard for easy, worldwide sourcing if replacement is necessary. Seals on Input and Output Shafts The Quantum Series is unique in the industry in that a non-contact bearing isolator seal is used on the input shaft. Typical designs use lip seals which have a finite life dictated by time and use. These older designs require costly shut downs for repair and maintenance. Since the bearing isolator used on the Quantum input shaft is non-contact, it should last the life of the fan drive and never require maintenance.

The Quantum Series is also unique in that it features a true dry well patent pending design for the output shaft. No seal is required or installed on this shaft that can wear and require costly maintenance and shutdowns. Amarillo Gear is a recognized expert in the design of dry well constructed gear boxes having used a similar design in a gear box produced for over 70 years. Shafting The Quantum series features input and output shafts properly designed and sized for rugged use in an ACC. Shafts are manufactured from alloy steel and all surfaces are precision machined to insure proper installation of the gears, bearings, input coupling and fan hub. A retaining plate is also provided on the output shaft to add additional security for interference fit fan hubs. The output shaft is available to a length specified by the customer. Lubrication An internal positive displacement oil pump provides bidirectional lubrication. All plumbing is internal to the gear case (except where an optional oil filter is specified) eliminating the risk of external oil leaks and handling damage. A dip stick and permanently mounted oil level sight gauge is provided on all units to provide direct visual determination of oil level. Sump magnets are also standard on the Quantum series. Amarillo also offers the popular GSU (Gear Service Unit) to further minimize maintenance of lubrication of the fan drive and to extend lubricants serviceable life. Contact Amarillo Gear for more information on the GSU. Another feature of the Quantum series is that no greasing of oil seals and bearings are required. All lubrication is provided by the generous oil sump. This eliminates costly shut downs and leaks related to overfilling or using the wrong grease. Breathers Each Quantum series fan drive is shipped with a hygroscopic breather to absorb moisture before it enters the fan drive. The breather is shipped loose with the fan drive and should be installed at the time of operation to ensure maximum life of the breather. Motor Stand Amarillo Gear has designed the motor stand for the Quantum series to rigidly and safely support common motors in use today. For your specific motor application, please contact Amarillo Gear Company. Retrofit Replacement for Other Models The Quantum series, specifically the Q-500, is designed as a drop in replacement for parallel shaft gear drives produced by other manufacturers. Please contact Amarillo Gear to find out how the Quantum series can bring reliability to your dry cooling system. Extended Limited Warranty Amarillo Gear is pleased to offer as standard, a 36 month limited warranty on the Quantum Q-500 parallel shaft fan drive. For details, please contact Amarillo Gear Company.

Popular Options Quantum Series Parallel Shaft Fan Drive for Dry Cooling Systems Amarillo Gear Company is pleased to offer many popular options requested by its customers to ensure the fan drive performs as required. Some of the options are listed below: Oil Filter (10 micron, spin on type) The Quantum Series Parallel Shaft Fan Drive for dry cooling systems reflect a long history of quality workmanship Non-reverse and backstop reliability. (internal) Amarillo Gear Company has been designing and manufacturing application Oil pressure specific switch gear or drives transmitters since 1934, and the commitment to excellence continues today. One example of this commitment is the availability of complete noise and vibration testing, with all data taken Low under oil level full switch power or loading, transmitters up to 250 hp (186 kw). Special marine paint finishes and colors All fan drives are spin tested prior to shipment and a complete conformity check is made. This ensures that Oil Amarillo temperature supplies switch the product or transmitters exactly as required and it will provide reliable service demanded by the Extended owner. lower bearing housing for increasing fan stability caused by dynamic loads Having Motor a to parallel fan drive shaft coupling fan drive specifically designed for dry cooling systems means the process for selecting Oil heaters the correct and thermostat fan drive is simple. It s as easy as following the steps shown below. For unusual applications, or extreme operating conditions, contact Amarillo Gear Company for help making the Oil sampling port correct selection. Quantum Series Parallel Shaft Fan Drive selection 1. Calculate the required ratio by dividing the motor speed (input) by the desired fan speed (output). COOLING FINS INSPECTION PORTS NPT HYDROSCOPIC DESCANT BREATHER NPT TRUE DRY WELL DESIGN FOR OUTPUT SHAFT; NO SEAL REQUIRED OIL TEMP. SWITCH OIL FILL PORT NPT NON-CONTACT BEARING ISOLATOR; NO SEAL REQUIRED 10 MICRON OIL FILTER OIL HEATER 1200 174 180 172 174 178 172 Ø CUSTOMER SPECIFIC LUBE GAUGE & SIGHT GLASS MOTOR MOUNT 2. Select the fan drive from Table 1 that has a motor power rating, ACCOMODATES under the required ratio column, that 447 TC/ TSC is equal or greater than the motor power at the motor speed. 449 All TC/ ratings TSC include an AGMA 2.0 service OIL LEVEL SWITCH factor on motor nameplate power which is generally recommended by leading industry designers of Air Cooled Condenser systems for long life and required reliability. Table 1 Service Power Ratings (AGMA Service Factor = 2.0 on motor nameplate power) Horse Power Rating Exact Ratio OIL SAMPLING PORT ACCELEROMETER MOUNT Model 1/4-28 UNF Input - 2B RPM 18.22 19.27 19.78 20.82 22.02 22.60 Q-500 1750 254 263 250 254 259 250 1500 218 225 214 218 222 214 Kilowatt Power Rating Vertical Down Thrust Capacity: 10,500 lbs. (47kN) Exact Ratio CUSTOMER SPECIFIC SHAFT LENGTH INTERNAL NON-REVERSE SPAG OIL DRAIN NPT Model Input OIL TEMP. RPM RTD 18.22 19.27 19.78 20.82 OIL PRESSURE SWITCH 22.02 22.60 Q-500 1750 189 196 186 189 193 186 1500 162 168 159 162 165 159 1200 130 134 128 OIL GALLEY TEMP. SWITCH 130 132 128

QUANTUM ARALLEL SHAFT Q-500 DIMENSIONS 33.27 30.63 20.50 8 "XBF" HOLES EQ. SP. ON A "XAJ" B.C. 27.98 19.50 19.30 19.30 19.50 23.03 CG 15.02 20.88 XBD XAK XAJ MOTOR REGISTER CHIME.20 Ø 1.7784±.0005 0.5 X 0.5 X 3.0 KEYWAY XN 23.53 A=28.21 1.00 CUSTOMER SPECIFIC CUSTOMER 1.25 x 1.25 SPECIFIC x 4.9 KEYWAY Ø CUSTOMER SPECIFIC