P R O D U C T D ATA S H E E T

Similar documents
TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

IGD. O p e r a t i o n a n d M a i n t e n a n c e V International Gas Detectors. Triton House Crosby Street Stockport SK2 6SH England

P R O D U C T D ATA S H E E T

TOC-20 SERIES. Refrigerant Gas Monitor. Installation and Operation Manual Version 3 IGD OLIVER CH4 NO. Document Ref: T20-V3

IGD.CO.UK

APPLICATION DATA SHEET

GAS DETECTION International Gas Detectors CH4 NO

TOCSIN 750 SERIES OLIVER IGD. Triton House Crosby Street Stockport SK2 6TS England

CH4 NO TOC-30A-AN1 TOC-30A-ANN TOC-30A-AN2 TOC-30A-AN3. Pepper Road Bramhall Technology Park Stockport SK7 5BW England. International Gas Detectors

3M Oldham OLCT 100. Description. Fixed Gas Detector

OLC(T) 100 FIXED GAS DETECTOR

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

APPLICATION DATA SHEET

CH4 SO2NO2. C O2 mount options. The controller has two SPCO relays as standard with three 4-20mA outputs and an RS485 Modbus UK Design And Manufacture

G-TECTA TM. Portable Gas Detection Instruments

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

2-WIRE SYSTEMS OLIVER IGD. 2-Wire. Version 3.2 T750-INST. Addressable. Triton House Crosby Street Stockport SK2 6SH England

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

APPLICATION DATA SHEET

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Dräger Polytron 5720 IR Toxic Gas Detection

GAS DETECTOR ST400EC PART.NO

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

HART TOCSIN 903 SINGLE CHANNEL GAS DETECTOR USER INSTRUCTIONS. Oliver IGD Limited NEW WITH OPTIONAL. 4a Pepper Road Stockport SK7 5BW England

Dräger Polytron 8200 Stationary gas detector (CatEx)

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

GAS DETECTION SYSTEMS

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Danfoss gas detection unit Type GD Heavy Duty

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

SYSTEMS LTD. Model «FDG3» LEADERS IN PROCESS ANALYSIS AND CONTROL

portable gas analyser

Two-Channel Gas Controller

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Sieger Apex. Flexibility that meets your requirements

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

ALTAIR 5X Multigas Detector

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Sensepoint XCD RTD. A gas transmitter for use with directly or remotely mounted toxic and Oxygen gas sensors

ALTAIR 5X Multigas Detector Product Specification

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 5720 IR Detection of carbon dioxide

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Dräger Polytron 8100 EC Detection of toxic gases and vapors

International Gas Detectors Ltd. Siting Gas Detectors. Gas detectors usually fall into three specific groups for placement

Monitores Personales. Personal Monitor

Dräger Polytron 5100 EC Detection of toxic gases and vapors

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Hygrometer / Air Quality Meter

GAS DETECTION SYSTEMS

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

T.ex Single Gas Detector VISA

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Dräger Polytron 5100 EC Detection of toxic gases and vapors

ULTIMA X5000. MSAX5000.com

Micro III (Models G203, G203S, and G213) Operation Manual

Stand Alone DYNAGARD SP Operation Manual

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

Safe Operation Manual. Honeywell IQ Force Gas Detector

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

14300 MAINS SEPARATOR ALARM MANUAL

SIL 2. Ultima X Series Gas Monitors CERTIFIED

INSTRUCTION MANUAL (ATEX / IECEx)

Inc Series Digital Gas Detector/Controller. Operation Manual

S5000 Gas Monitor. GMS5000.com

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

MICRO III (G202 / G202s / G212) Single Gas Detector

Gas Controller Module GC-06

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

SUPREMATouch. Modular Fire & Gas Detection System

Sensepoint XCD. Flammable, toxic and oxygen. catalytic, electrochemical cell and infrared sensors.

ESD3000 ESD200 Combustible / Toxic Gas Detector

Transcription:

TOCSIN 750 SERIES ANNUNCIATORS Addressable Gas Detection Interface Point -Wire Addressable Systems Sounder Display Shows: Reading-Message-Alarm RGB Relay Output off Solid State Beacon Sounder Output off Digital Inputs, 4-0mA Inputs or TOC-10 Inputs E-Stop Key Switch Gas Detector Input Flammable - Toxic - Oxygen Detection Core Cable Unscreened Addressable Interface to Controller. Network up to 3 Annunciators or other Addressable Devices per Highway. Clear Effective Reliable Protection Feature Rich Colour RGB Status Display Sounder Install 750 Series Annunciators for effective Door Entry Protection or for Room Status Display. Slam Switch Green Display with Message When all is Good Changing to Flashing Red with Message in Alarm. With its Built in Sounder, 750 Annunciators Provide Clear Unambiguous Indication. Know Instantly The Hazard and Don't Confuse With Fire or Security Alarms. Add to this 750 Series Control Relay Digital or Analogue Device Inputs Gas Detectors For Flammable Gases GD Toxic Gases or Oxygen Detection Annunciators Include Interfacing For Gas Detectors and Your System Devices Providing Simple Installation with Enhanced Safety HSCO SOCO SK 6TS Fax: +44 (0) 161 484 345 REF T10--3R-V1.06 Ref: T750A

Standard Specifications Standard Features Power 1 to 6V DC Colour Change display: Construction ABS Green: No Alarm Display Optional x 8 RGB LCD Flashing Red: alarm User Options for E-Stop and Key Switch Amber: Fault I/O 1 off SPCO Relays 4A/30V AC Non-Inductive User Configurable from 650/750 Controllers multifunction ports as: Digital Input Max 0.Hz Digital Input 0-3V Max 0.Hz 4-0mA input or Solid State Output 4V DC Max 300mA shared Across both Ports Input From TOC-10 Link Function Blue: Menu system Sensor sounder Direct Pellistor Interface Custom Message Display: Green (no alarm) Default Message: ALL CLEAR Note this alternates with the gas reading for any connected detector. Red (alarm) Default Message: GAS ALERT Amber (fault) Default Message: SYSTEM FAULT Input for Toxic,Oxygen, Infra red and PID detectors Messages can be altered as required. 85dB I/O can be configured to suit application, as much or as little as required. Communication Sentinel+ Protocol, -Wire Connection A,B All settings battery backed on module Temperature 0 to 55 Deg C Humidity 0-95% RH Non-Condensing Sealing IP55 Mounting Wall Mount Weight 1.75Kg Constant monitoring for faults Calibration interface for connected detectors REF: T750A HSCO SOCO SK 6TS Fax: +44 (0) 161 484 345 REF T10--3R-V1.06 Ref: T750A

Issuers name and address: EC Declaration of Conformity Oliver Limited of Declares that the product listed as: TOCSIN 750 SERIES ANNUNCIATOR Crosby St,, Addressable -Wire Gas Detection System I/O Point United Kingdom Are in conformity with the provisions of the following European Directive(s) when installed, operated, serviced and maintained in accordance with the installation and operating instructions contained in the product documentation. 004/108/EC EMC Directive 006/95/EC Low Voltage Equipment Directive (note not applicable to 4V DC Powered Versions) And that the standards and/or technical specifications referenced below have been applied or considered. EN 61779-1:000 Electrical apparatus for the detection and measurement of flammable gases, general requirements and test methods. EN 5071:010 Electrical apparatus for the detection and measurement of combustible gases, toxic gases or Oxygen: requirements and tests for apparatus using software and or digital technologies. Excluding requirements for SIL EMC Generic standards. Immunity for industrial environments EN 61000-6-: 005 EN 61000-6-4: 007/A1: 011 EMC Generic standards. Emission standard for industrial environments EMC Limits. Limits for harmonic current emissions (equipment input current 16 A per phase) EN 61000-3-: 014 EMC Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage EN 61000-3-3: 013 supply systems, for equipment with rated current 16 A per phase Technical File Reference Product Markings T750ANN-TF9 TOC-750-ANN Oliver Limited Operate and Independently assessed ATEX/IECEX QAN. Quality Assurance Certificate Number ExVeritas 16PQAN0014 Quality Assurance Notification Number: 585 ExVeritas, Units 16-18, Abenbury Way, Wrexham Industrial Estate, Wrexham, UK, LL13 9UZ S/-serial number Oliver Limited operate an independently assessed Testing Agency: ISO9001:008 Quality Management System. TUV - SUD Octagon House Concorde Way Quality Management Certificate Number PO 15 5RL FS 646773 Fareham BSI Assurance UK LTD, Chiswick High Road, London W4 4AL UK TUV Certificates and reports can be checked on-line at https://www.tuev-sued.de/industry_and_consumer_products/certificates Issued by: Oliver Limited,, SK 6TS, United Kingdom Signature: Declaration of Conformity in accordance with EN ISO/IEC 17050-1:010 Name Andrew J Collier M.I.O.D Position: Managing Director Date: HSCO SOCO SK 6TS 1.June 016 Declaration Ref: T750ANN-DEC- Fax: +44 (0) 161 484 345 REF T10--3R-V1.06 Ref: T750A

PART NUMBERS & FEATURES Part Number Description Multifunction-IO Relay Sounder Display E-Stop Key Switch RGB Display TOC-750-APP Base Unit with Gas Detector TOC-750-AP1 With E-Stop TOC-750-AP With Key Switch TOC-750-AP3 With Key Switch & E-Stop TOC-750-ATX With Type B ATEX Gas Detector TOC-750-IO No Display IO Function Only Annunciator Technical Housing Sealing Environment Temperature Voltage Communication Relay Inputs/Outputs Sounder Display ABS IP65 (using suitable glanding) 0-95% RH Non Condensing 0-55 Deg C 1-6V DC Sentinel+ Protocol -Wire Power and Data Highway Connections as: A, B 4A Non Inductive Loads 30V AC Gas Detector, TOC-10 Link Function Input (see TOC-10), Digital Switch, Solid State Outputs 85dB x 8 Programmable LCD with RGB Backlight Annunciator Mounting details and dimensions 17 158 76 48 43 86 5 0mm Entries Top, Bottom & Either Side 98 18 Note TOC-750-AP3 Shown Typical safe area detector on page 3 HSCO SOCO SK 6TS Fax: +44 (0) 161 484 345 REF T10--3R-V1.06 Ref: T750A

Gas Detector Mounting details and dimensions Toc-750 Detectors & Toc-750 Annunciator Series 17 158 98 18 44 76 SN:035-1-1 ADD:4110 0mm Entries Top, Bottom & Either Side Interface Locations View with front cover removed Core Cable Power & Comms Unscreened Mk7 or P-Y-W Type B ATEX Pellistor Flammable Gas Detector Interface SN:035-1-1 ADD:4110 3 Core Cable Pellistor Connection P-Y-W Core Cable Power & Comms Unscreened Configurable Switched Input or Solid State O/P or 4-0mA Input Configurable Switched Input or Solid State O/P or 4-0mA Input Gas Solenoid Fused Spur Example Only TOC-30A Series Gas Detector Interface SN:035-1-1 ADD:4110 SPCO Relay for Switching External Loads HSCO SOCO SK 6TS Fax: +44 (0) 161 484 345 REF T10--3R-V1.06 Ref: T750A

TOC-750 Series Safe Area Gas Detectors Detectors 750 Series Gas Detectors provide accurate measurement of the background atmosphere for a specific hazardous target gas. Clean lines and easy integration into existing or newly planned control systems make the TOC Series the safety engineers device of choice. Using the latest microprocessor -Wire addressable technology and software TOC Series detectors are a reliable long term monitoring solution. TOC 750 Series Detectors are supplied pre-calibrated ready to use and directly connect to TOCSIN 650 or 750 Series Controllers. Order Codes TOC-750 Series Detectors Gas Standard Range Order Code Typical Cell Life Flammable Gases 0-100% LEL TOC-750-PHC >3 Years Carbon Monoxide TOC-750-CO >5 Years Oxygen 0-30% Vol TOC-750-O >5 Years Nitric Oxide 0-00ppm TOC-750- > Years Nitrogen Dioxide 0-0ppm TOC-750- > Years Ammonia TOC-750-NH3 > Years Chlorine 0-0ppm TOC-750-CL > Years Detector Fitted with gas collector cone and remote gassing facility Order Codes Gas Collector Cone For TOC-750 Series Remote Gassing Facility Splash Guard Calibration Adaptor TOC0/30 Series Code TOC-750-CNE Code TOC-750-RME Code TOC-750-SPL Code 4011109 Full Specifications Refer to 750 Safe Area Detector data sheet Mounting details and dimensions Toc-750 Safe Area Detectors 17 158 98 18 44 76 SN:035-1-1 ADD:4110 0mm Entries Top, Bottom & Either Side HSCO SOCO SK 6TS Fax: +44 (0) 161 484 345 REF T10--3R-V1.06 Ref: T750A

TOC-750 Series Atex Gas Detectors Detectors 750 Series Gas Detectors ATEX Gas Detectors provide the ultimate in safety for gas detection in hazardous areas. Approved to the latest ATEX standards and utilising s -Wire Sentinel+ technology this range is simple to install, robust in operation with peace of mind that plant and personnel are effectively protected. s comprehensive range provides protection for all your gas hazards Order Codes TOC-750 Series ATEX Gas Detectors Sensor type Part Number Flammable Gases Pellistor TOC-750-ATX Min Range Max Range TOC-750-AP4 With Display And E-Stop Display Non ATEX Flammable Gases Infra-Red Point TOC-750A-FL TOC-750A-HFL Carbon Dioxide Infra-Red Point TOC-750A-CO TOC-750-ATX 0-100%Vol 0-3000ppm 0-5000ppm 0-% 0-5% TOC-750A-HCO 0-100% TOC-750A-CO 0-1000ppm TOC-750A-HCO 0-000ppm 0-4000ppm Nitric Oxide TOC-750A- Nitrogen Dioxide TOC-750A- 0-0ppm Hydrogen Cyanide TOC-750A-HCN 0-10ppm 0-00ppm Hydrogen Sulphide TOC-750A-HS TOC-750A-HHS 0-500ppm 0-1000ppm TOC-750A-VHS 0-5000ppm 0-10000ppm TOC-750A-NH3 0-00ppm TOC-750A-HNH3 0-1000ppm 0-000ppm TOC-750A-VNH3 0-5000ppm 0-7000ppm Oxygen TOC-750A-0 0-5% Sulphur Dioxide TOC-750A-SO 0-5ppm Hydrogen Chloride TOC-750A-HCL 0-5ppm Hydrogen TOC-750A-H 0-00ppm 0-000ppm Carbon Monoxide Ammonia HSCO SOCO SK 6TS TOC-750A-HS II D G Ex db IIC T6 Gb IECEx EXV16.000X ExVeritas 16ATEX0140X Ex tb IIIC Db. M0 Entries Ex db IIC T6 Gb Ta = -0 to +40 C Ex tb IIIC T85 C Db IP66 Ex db IIC T5 Gb Ta = -0 to +55 C Ex tb IIIC T100 C Db IP66 IECEx EXV16.003X Rating W ExVeritas 16ATEX 0141X 585 Full Specifications Refer to 750 ATEX data sheet Fax: +44 (0) 161 484 345 REF T10--3R-V1.06 Ref: T750A

System Example SN:035-1-1 ADD:4110 Use Annunciators For Door Entry Control. Use Annunciators with Gas Detector Interfaces to Detect & Alarm in Specific Areas Controller in Supervisors Office Laboratory Mix Annunciators With Other Addressable Devices Such as TOC-750 Series Detectors. Use ATEX Rated detectors where required SN:035-1-1 ADD:4110 Gas Bottle Store Core Highway as: 4V A,B Typically 1.5mmSQ Unscreened Cable Use the Detector or Annunciator I/O Capability to Control Gas Supply Valves, Beacon-Sounders or other devices ATEX Zoned Area HSCO SOCO SK 6TS Fax: +44 (0) 161 484 345 REF T10--3R-V1.06 Ref: T750A