NOFIQ detects, alarms and extinguishes a starting fire automatically.

Similar documents
The five primary functions of NOFIQ can operate without human intervention, so preventing the rapid expansion of the fire. SAFE.

Cold chain monitoring technologies. Facility monitoring

WIRELESS SOLUTIONS FOR RESIDENCES. A Group brand

Multi-Gas-Controller MGC2

Sun Ray Electric Radiators Stylish, Efficient, Low Energy

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

Data Center. Cold Storage

USER MANUAL FOR OPERATING SYSTEM

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

TABLE OF CONTENTS. Page 2

Sirius SAT. Working towards a cleaner future. Heat Boxes with Wireless Data Transmission. heating specialists

LORAIN CIP 4890/48120 DC Power System

InvisiFence User Manual

Danfoss gas detection units

DSE ELECTRONIC SIRENS Advantages & Functions

OPTIMUM APPLIED SYSTEMS,

Intellia Sounder Bases and Sounder Beacon Bases

Detection, and Suppression Systems

NEW RANGE OF WARM AIR CURTAINS

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

HRX Technical Manual. Version 1.2

HRX3000. Technical Manual

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Added password for IP setup page : Password must be in IP format!

Smart Wireless Devices LAN-WMBUS-M. Wireless MBUS, door and window sensor. With optional glass break accessory.

OJ Waterline control system

BSC-50 ADU-500. Autonomous RTUs

FIRElux Emergency Lighting

HART XL High Sensitivity Smoke Detection

600 Range Dialer Installation Manual. Version 1.0

Chlorine gas leak detector

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

LORAIN CSP DC Power System

Wireless Smart Metering LAN-WMBUS-M. Wireless MBUS, door and window sensor. With optional glass break accessory.

Ness acomms Install & User Manual

Monitoring Solutions

REPEATER FS5200R INSTRUCTION MANUAL

Public Address Project Combisound System

P R O D U C T D ATA S H E E T

PitBoss User Manual. Version /24/2013 Copyright 2013 PumpAlarm.com, LLC

Integrated Security Solutions

Wireless Alarm Systems

Amjo Corp is the creator and developer of the aka web site.

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

Affordable wireless monitoring without compromise

Radio fire warning panel SRC 3000

Product Catalogue Carephones and Telecare solutions for independent living

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL

Call stations and extensions

Security made in Germany

Gas Controller Module GC-06

Automatic Fire Extinguishing System for Mobile Units VES-SRA1 Type with Electric Remote Controlled Monitors

SMD601 Plus. The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities. Threat Detection through Electromagnetics

MAMI MULTI BASE STATION

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

HA06. User manual. (SDO Hot Air One) HOT AIR / QUARTZ REFLOW OVEN. Version 2.21

HART XL High Sensitivity Smoke Detection

GAS EXTINGUISHING SYSTEMS COMPACT EXTINGUISHING SYSTEMS. OneU. Fire Protection Systems for 19" Racks

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200. Issue 01

Multifunction IAQ Monitor

Local Control Network - building controls in perfection

Very High Sensitivity Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.

0KITMGSM00 KIT FOR BOILER CONTROL THROUGH GSM FOR ITACA - FORMENTERA INSTALLATION USE AND MAINTENANCE

Integrated Security Solutions

Gas ventilation monitoring and control system

Product Guide MAN7030-2

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

*** Quotation*** Joney Technology Co.,Ltd Wireless Control Panel/Detector/Accessories. CE RoHS APPROVAL PICTURE NEW

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

Carbon Monoxide CO Transmitter ADT-X3-1110

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

ACC RADIO CONTROL SYSTEM. Rev A 12/23/14

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Affordable wireless monitoring without compromise

EC3-X33 Stand-alone Superheat Controller Technical Data

CU-IQ MANUAL 1. DESCRIPTION Radio Control Panel CU-IQ

Wireless security products

The product can be worked together with our wireless controller to control a ventilator, air cleaning device, or

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

The supplier and installer of the system should be approved by the local civil defence authority.

SYSTEM OVERVIEW. Environmental Monitoring. Simplified.

GL BAL GLEDAL 150W B L A Z E AISL E L IGHT SPECIFICATION SHE ET OPTICAL SPECS ELECTRICAL SPECS CERTIFICATIONS OTHER DETAILS DIMENSIONS BEAM ANGLES

Building Technologies

Excel Click & Go Lite

Owners Manual OWNERS MANUAL. Australia s original Outdoor brand. Part No. Comp830Li. SAI Global Cert. SAI AS

CO SENSOR CARBON MONOXIDE DETECTOR

Heimdall Radar Traffic Detector

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200 with resevoir. Issue 01

Solutions for Smarter Home Security

Sentry Freedom Wireless Emergency Call

Pre-programmed room controller with communication

EasyTronic III MANUAL SERVICE

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

Electronic pellet burner controller - NPBC-V3M. Electronic Pellet Burner Controller NPBC-V3M

Hygrometer / Air Quality Meter

Transcription:

max. 4 units cable-connected Electrical equipment like switch cabinets, meter boxes and computers are potential seats of fire. From now on these objects can be protected optimally thanks to the NOFIQ fire protection system. NOFIQ continuously monitors the carbon monoxide concentration and the temperature inside these objects. As soon as one of these value increases at a certain rate or reaches a critical level, an alarm will be reported to the alarm management station. NOFIQ detects, alarms and extinguishes a starting fire automatically. Existing systems, like for example sprinklers, are only put into operation after the inside of the electrical equipment is completely on fire and flames are already outside of the objects. From that moment on a fire is much harder to control and it will result in smoke, soot and water damage. Thanks to NOFIQ, fire detecting, alarming and extinguishing is now possible without human intervention. Thus rapid expansion of a fire is prevented. Specsheet-E-V05.ALG-sep2010

The NOFIQ BASE is the alarm management station of the NOFIQ fire protection system. The NOFIQ BASE registers alarm and error messages reported by the system s FE s and HUBs. The NOFIQ BASE can be connected to existing infrastructure (building management system, existing fire alarm, etc.) art. nr.:1020.1000.0000 alarm management station display type LCD; number of characters 2 x 40 acoustic signal 4/5 khz @ 65 db(a) 10 coloured LEDs (red, yellow and green) power supply primary power supply: AC-DC adapter 110V-260V 50-60 Hz emergency power supply: maintenance-free battery, at least 24 hours output / input 5 x potential-free switch contacts 24V DC / 1A (max. 30V DC / 1A) (notification alarm, error); RS232 connector (configuration and maintenance); 1 x RJ11 analogue telephone connector (for notification of alarm or error over telephone line); serial communication BASE-HUB environmental temperature -10 o C...+60 o C; air humidity <95% RH; air pressure 86-106 kpa housing Fe360 powdercoat / IP30, weight 4 kg; dimensions (hxwxd) 304 x 244 x 89mm accessories supplied 1 x right-angled euro connector (art.nr. 1020.1000.0020) 1 x manual (art.nr. 1020.1000.0009) 1 x warning sign (art.nr. 1020.1000.0016) 2 x authorisation keys; 2 x cabinet keys; 6 x cable couplings (art.nr. 1020.1000.0023) 3 metres fire-resistant cable type E30 (art.nr. 1020.1000.0018) Specsheet-E-V05.BASE-sep2010

The NOFIQ BASE-HUB is the transfer station of the NOFIQ BASE. The NOFIQ BASE-HUB translates all messages sent by FE s and HUBs to the BASE. The NOFIQ BASE-HUB is always supplied in combination with the NOFIQ BASE. art. nr.:1020.2000.0000 transmitting and receiving station of the NOFIQ BASE power supply through NOFIQ BASE output / input serial communication with the NOFIQ BASE environmental temperature -10 o C...+60 o C; air humidity <95% RH; air pressure 86-106 kpa housing polycarbonate / class V-2 / IP30; weight 250 gr.; dimensions (h x w x d) 272 x 74 x 46 mm accessories supplied 1 x NOFIQ antenna (art.nr. 1020.4000.0009) optional accessories NOFIQ advanced antenna Specsheet-E-V05.BASEHUB-sep2010

The NOFIQ HUB routes the wireless signal from the various NOFIQ FE s and other HUBs to the BASE. The NOFIQ HUB bridges the distance between the various components. A large network of NOFIQ FE s, spread out over larger distances, is no problem thanks to the NOFIQ HUB. art. nr.:1020.3000.0000 acoustic signal signal repeater NOFIQ system 4/5 khz @ 55 db(a) power supply internal: NOFIQ battery-pack, lifetime 2 years (art.nr. 1020.4000.0010) external: NOFIQ mains power adapter (art.nr. 1020.3000.0004) output / input input external power supply (primary power supply / supplemental battery-pack) environmental temperature -10 o C...+60 o C; air humidity <95% RH; air pressure 86-106 kpa housing polycarbonate / class V-2 / IP30; weight 250 gr.; dimensions (h x w x d) 272 x 74 x 46 mm accessories supplied 1x NOFIQ antenna (art.nr. 1020.4000.0009) 1x NOFIQ battery-pack (art.nr. 1020.4000.0010) optional accessories NOFIQ advanced antenna; 1x NOFIQ mains power adapter (art.nr. 1020.3000.0004) Specsheet-E-V05.HUB-sep2010

The NOFIQ FE20 is a fully automatic and autonomous extinguishing system. Thanks to an optimal combination of CO and temperature detection, it can detect, alarm, communicate and extinguish a starting fire in its initial phase. It can be applied in switch cabinets, meter boxes and computers. art. nr.:1020.4000.0000 extinguishing agent switch cabinets, meter boxes, computers DSPA.nl aërosol component FP-20 (net weight extinguishing agent: 20 grams) fire classes solids 0,24m 3 ; liquids 0,25m 3 ; gasses 0,44 m 3 ; oils and fats 0,17 m 3 acoustic signal 4/5 khz @ 55 db(a) power supply internal: NOFIQ battery-pack, lifetime 2 years (art.nr. 1020.4000.0010) external: NOFIQ mains power adapter (art.nr. 1020.3000.0004) output / input environmental housing InterNOFIQBus (group extinguishing for max. 4 FE s); potential-free switch contact 24V / 1A (switch off ventilation provision or power sources); input external power supply (use low temp./ supplemental battery-pack) temperature -10 o C...+45 o C; air humidity <95% RH; air pressure 86-106 kpa polycarbonate / class V-2 / IP30; weight 350 gr.; dimensions (h x w x d) 249 x 44 x 68 mm accessories supplied 1 x NOFIQ antenna (art.nr. 1020.4000.0009); 1 x NOFIQ battery-pack (art.nr. 1020.4000.0010) optional accessories 1 x NOFIQ mains power adapter (art.nr. 1020.3000.0004); antenna extension cord; antenna base; NOFIQ advanced antenna Specsheet-E-V05.N20-sep2010

The NOFIQ FE80 is a fully automatic and autonomous extinguishing system. Thanks to an optimal combination of CO and temperature detection, it can detect, alarm, communicate and extinguish a starting fire in its initial phase. It can be applied in switch cabinets, meter boxes and computers. art. nr.:1080.4000.0000 extinguishing agent switch cabinets, meter boxes, computers DSPA.nl aërosol component FP-80 (net weight extinguishing agent: 80 grams) fire classes solids 0,89m 3 ; liquids 0,95m 3 ; gasses 1,64 m 3 ; oils and fats 0,64 m 3 acoustic signal 4/5 khz @ 55 db(a) power supply internal: NOFIQ battery-pack, lifetime 2 years (art.nr. 1020.4000.0010) external: NOFIQ mains power adapter (art.nr. 1020.3000.0004) output / input environmental housing InterNOFIQBus (group extinguishing for max. 4 FE s); potential-free switch contact 24V / 1A (switch off ventilation provision or power sources); input external power supply (use low temp./ supplemental battery-pack) temperature -10 o C...+45 o C; air humidity <95% RH; air pressure 86-106 kpa polycarbonate / class V-2 / IP30; weight 690 gr. ; dimensions (h x w x d) 312 x 68 x 97 mm accessories supplied 1 x NOFIQ antenna (art.nr. 1020.4000.0009); 1 x NOFIQ battery-pack (art.nr. 1020.4000.0010) optional accessories 1 x NOFIQ mains power adapter (art.nr. 1020.3000.0004); antenna extension cord; antenna base; NOFIQ advanced antenna Specsheet-E-V05.N80-sep2010