Nurse Call Systems & Emergency Call Systems. Overview of ANSI/UL 1069 and ANSI/UL 2560

Similar documents
2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Independent Living without Leaving Home. Personal Emergency Reporting Systems from Linear

Applying Performance-based Fire Alarm System Design Part 4

SECTION NURSE CALL SYSTEM

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

RULES OF THE TENNESSEE DEPARTMENT OF INTELLECTUAL AND DEVELOPMENTAL DISABILITIES OFFICE OF LICENSURE CHAPTER LIFE SAFETY LICENSURE RULES

Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

2018 NICET Code Transition Changes

Changes in NFPA

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

NFPA 72 Code Changes vs 2013

Established /10/2015. Doran Pruisner Dan Wood

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

Staff Alert Panel. Installation Guide. Using the Touchpad Exit Controller B

Unified Fire Authority - Fire Prevention Bureau

Fire Alarm System Fundamentals

Fire Alarm and Life Safety System Inspection Certificate

Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7

El Reno Fire Department Fire Alarm Plan Review Worksheet

1 Exam Prep Fire Alarm Signaling Systems Tabs and Highlights

Danilo B. Concepcion, CBNT, CCHT-A Operations Manager St. Joseph Hospital Renal Services

First Revision No NFPA [ Section No ]

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

Changes to NFPA 101A 2013 Edition for Health Care Facilities

LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE

A Complete Smart Care Solution

Quick Response. Plus Wireless Call Solution

Chapter 43, Building Rehabilitation allows for degrees of compliance based on the work category such as the extent of work.

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

SAF-BCF SECOND REVISIONS WITH STATEMENTS

ERS-3600B. PERS-3600B Personal Emergency Reporting System

EFFECTIVE DECEMBER 28, 2010 SECTION 610 CARBON MONOXIDE ALARMS

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

ResidentGUARD Security Systems

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Wanderer Security Systems FOR COMPLETE RESIDENT SAFETY

Code Alert Series 30 Software User Guide

GENERAL FIRE PROCEDURES

Overview of Fire Alarm Provisions Based on the 2012 IBC, IFC and NFPA 72, 2013 Edition

The 2013 National Fire Alarm and Signaling Code


Iowa State Fire Marshal

UNION DESARROLLOS ELECTRONICOS, S.A. udecom Nurse call system

2012 International Fire Code Errata (Portions of text and tables not shown are unaffected by the errata)

SECTION 915 CARBON MONOXIDE DETECTION

System Comparison Chart BY ACCUTECH

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

FIRE ALARM SYSTEMS & 780 CMR. Dave LeBlanc, PE, FSFPE March 17, 2015

Enactment Date: Rapid Intervention Team and RIT Officer

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC)

MODULE 8. Tying the Systems Together: Emergency Control Functions and Interfaces

Cedar Hammock Fire Rescue Standard Operational Guidelines FIRE WATCH. General. Requirements for a Fire Watch

Finally, an affordable wireless call bell system for smaller facilities

A Complete Smart Care Solution

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

CODE ALERT Enterprise Software User Guide

Public. Mike Free Health. State of Alabama Department of

ASHE Advocacy Team. Q4 ASHE Advocacy Liaison Webinar 12/7/16 12/7/16. Tim Adams, FASHE, CHFM, CHC Director of Leadership Development

Emergency Planning for Institutional Facilities

Public Health Fax: Web Site:

Fire Safety Plan FOR. Business/Property Name: Address: Phone Number: Occupancy Classification. Approved by Fire Inspector: Date:

MNEC NFPA 72 WHITE PAPER

University Design Standard Fire Alarm Systems

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

Sentry Freedom Wireless Emergency Call

Emergency Evacuation Plan

The WAVE Plus Instant Notification System for Schools and Colleges

St. Vincent s Health System Page 1 of 6

Infant & Pediatric Security Solutions

EC EP 14 All other electrical K-920 equipment in patient care vicinity NFPA , Chapter 10

Situational Awareness for Life & Fire Safety. October 10, 2013

Agency for Health Care Administration

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Written Fire Safety Plans

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates

WIRELESS SIGNAL UNIT FEATURES

2012 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

Mass Notification Systems

Report on First Revisions with Statement June 2014 NFPA 101

FIRE SAFETY AND EVACUATION PLANNING FOR ASSISTED LIVING FACILITIES AND NURSING HOMES

Compliance w/ the 2012 Life Safety Code

INSPECTION AND TESTING FORM

IFC Significant Changes from the 2009 to the 2015 Edition Tier 1

BCU Critical Care Fire Action Plan

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

Environmental Planning and Assessment Amendment (Smoke Alarms) Regulation 2006

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Emergency Communications

Responder IV Wireless Bed Interface User s Guide

AlertWave Smart Wireless Solutions for Today s Campus Whether you are a large university

Telligence Operation Manual

Transcription:

Nurse Call Systems & Emergency Call Systems Overview of ANSI/UL 1069 and ANSI/UL 2560 The Association of Electrical and

Overview National Consensus Standards American National Standards Institute (ANSI) Nurse Call Systems Emergency Call Systems Overview of new UL2560 Standard Differences between UL1069 and UL2560 Applicability of Standards 3

Nurse Call Systems & UL1069 4

Consensus Standards UL1069 complies with all relevant articles of NFPA70 National Electrical Code and NFPA99 Health Care Facilities Code NFPA101 (Life Safety Code) 18.1.1.1.2/3 defines Healthcare facilities to be where the occupants sleep there, but are not reasonably able to evacuate themselves in an emergency As such, these facilities have 24-hour staff on duty 5

Nurse Call Systems UL1069 Hospital Signaling and Nurse Call Equipment Created in 1977 by UL and Nurse Call industry 7 th edition (October 2007) clarifications/additions focused on three areas: Wireless nurse call devices Definition and verification of core system elements Definition of oxygen-enriched testing for pendant controls 6

Nurse Call Systems Wireless Nurse Call Devices Wireless initiating devices, as part of the fundamental system, have clear limitations: 1) The intent of wireless devices is to extend the coverage of a hard-wired system, however, only initiating devices can be wireless 2) The fundamental notification devices MUST be wired 3) Wireless devices utilize a shared radio frequency (RF) space Not guaranteed to be available or work in all real world environments UL1069 adds requirements to assure best possible reliability 7

Nurse Call Systems Wireless Nurse Call Devices Wireless initiating devices, as part of the fundamental system, have clear limitations: 4) Devices are supervised. Loss of contact with receiver for more than 90 seconds (including interference, loss of battery power, damage, etc.) = a supervisory alarm This requirement is based on testing the LARGEST possible system Note: On systems listed prior to Ed 7, the supervision time may be 24 hours Extensive testing required to assure devices will work in predictable interference scenarios Systems must have designs that hop or move frequencies to work around potential interferences 8

Nurse Call Systems Fundamental System Requirements UL1069 defines the fundamental nurse call system devices: Patient Station Bath Station Emergency Station Corridor Light Console Power and Control A system without corridor lights cannot be UL1069 listed 9

Nurse Call Systems Oxygen-Enriched Environments UL1069-listed systems fully comply with NFPA99 for safety of pendant devices (call cords and pillow speakers) in oxygen-enriched environments 10

Emergency Call Systems & UL 2560 11

Emergency Call Systems UL2560 Emergency Call Systems for Assisted Living and Independent Living Facilities 1 st edition published September, 2011 Addresses minimum performance of emergency call (e-call) systems in senior living communities 12

Emergency Call Systems UL2560 Requirements Placement Permanently fixed e-call station must be located in every resident bathroom Additional optional stations at resident beds, elsewhere in living areas and common areas are allowed Pendants Pendants are optional, but if included, must comply with the standard Assigning pendants to residents does not remove requirements for at least one fixed e-call station in each resident bathroom 13

Emergency Call Systems UL2560 Requirements Call Indicator E-call stations and pendants must include call assurance indication Central Notification Station There must be at least one notification station to receive all calls Must be at a fixed location Additional optional portable notification stations are allowed 14

Emergency Call Systems UL2560 Requirements Origination Reporting The origin of a resident call must be reported at a notification station The origin must be specific e.g. Apt 117 or 3 rd Floor Men s Room Cancellation Call (from fixed station or pendant) must be canceled at the source of the call Exception: If the system can separate non-emergency resident calls from emergency resident calls and there is voice communication between the e-call station and notification station Non-emergency calls can be canceled from notification station after voice contact with resident has been made 15

Emergency Call Systems Other UL2560 Requirements Connection Testing System Testing Back-up Power Low Battery Alarm Interference Testing To obtain a copy of UL2560: http://ulstandardsinfonet.ul.com/catalog/stdscatframe.html 16

Comparison of the Standards 17

Standards Comparison Required Call Notification Supervision of Wireless Initiating Devices Mobility UL1069 Wired - Console and corridor lights Every 90 seconds Assumes patient is not mobile UL2560 Wired/Wireless Console only Every 24 hours Assumes resident is mobile Nursing Staff 24/7 Required Not required 18

Applicability of the Standards 19

Applicability of Standards When UL1069 Applies Systems covered by the standard are intended to be installed in either General or Critical Care areas in accordance with: National Electrical Code (NFPA70) Health Care Facilities Code (NFPA99) Life Safety Code (NFPA101- Chapter 18) 20

Applicability of Standards When UL2560 Applies Systems covered by standard are intended to be installed in: Assisted and independent living facilities 24/7 staffing is not required Residents can reasonably be assumed to evacuate themselves in an emergency 21

Importance of Listing 22

Importance of Listing When nurse call systems are listed to UL1069 and emergency call systems to UL2560, you can count on: Product safety for all users System reliability Corporate integrity to design to the highest standards now and as new requirements are implemented Peace of mind for staff, patients, residents, and relatives 23

Questions? Thank You! 24