Installation Instructions

Similar documents
Small Digital Thermostat Controller Temperature Control

5+2 Day. up to HEAT COOL

Installation Instructions HEAT COOL FAN POWER

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCPS101 TSTATBBPS101 P Digital Thermostat 6:03

Installation Instructions

2 - Wire Programmable Digital Thermostat

HEAT COOL 5+2 DAY PROGRAMMABLE 1-STAGE HEAT, 1-STAGE COOL. Installation Instructions TSTATCCPQ501 TSTATBBPQ501 P Digital Thermostat I2:00

7-Day. Digital Thermostat. residential. & 2-cool

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCNB001 TSTATBBNB001 P Digital Thermostat

HEAT HEAT PUMP TOTALINE. Installation Instructions DIGITAL THERMOSTAT MODEL P FM. I2:00 Mo COOL

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

asy Single Day up to 2-heat & 2-cool Stat

INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

HEAT HEAT HEAT COOL COOL

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

Non-Programmable Digital Thermostat

Owner s Manual. Digital Thermostat. Non-Programmable

OWNER'S MANUAL T0140. Contents Page #

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

Installation Instructions

XFlat Blade. Installation Instructions DIGITAL THERMOSTAT 53DFS250-SL. CoolingOnly,Heat Cool,and Heat Pump MULTI-STAGE SEVEN DAY PROGRAMMABLE

HEAT COOL HEAT PUMP MULTI-STAGE SINGLEDAYPROGRAMMABLE TSTATCCPB101 TSTATBBPB101 P Digital Thermostat

Installation Instructions

Owner s Manual. Digital Thermostat

Programmable 5-2 Day Digital Thermostat

5+2 DAY INSTALLATION. Digital Thermostat. residential. & 1-cool. up to. 1-heat PROGRAMMABLE HEAT COOL HEAT PUMP THERMOSTAT. Venstar Inc.

P/N TSTAT0709 DIGITAL THERMOSTAT. Installation Instructions HEAT COOL. Warmer HEAT PUMP. International Comfort Products 2003

INSTALLATION INSTRUCTIONS FAN COIL PROGRAMMABLE DIGITAL THERMOSTAT. Meets California Title 24

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat:

HEAT HEAT HEAT COOL COOL

1 For All Programmable Digital Thermostat

P/N TSTAT0713K 1 For All Programmable Temperature & Humidity AUTO 70 COOL. 2 HEAT - 2 COOL Meets Residential California Title 24

7-Day. Digital Thermostat. residential. & 2-cool

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

Auto-Changeover: Cool Setpoint: Deadband: Differential: Heat Setpoint: Icon: Mode: Non-Programmable Thermostat: Programmable Thermostat:

Programmable Digital Thermostat

DIGITAL THERMOSTAT Up To 2 Heat & 2 Cool Stages with Humidity Control

Auto-Changeover: A mode in which the thermostat will turn on the heating or cooling based on room temperature demand.

2 HEAT - 1 COOL Meets Residential California Title 24

T-32-TS Touchscreen Thermostat. Installation Manual

Owner s Manual. Premier Series Digital Thermostat. and Installation Instructions. Non-Programmable with Humidity Control COMMERCIAL

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Programmable Thermostat

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

OWNER S MANUAL Venstar Inc. 08/07

CTS Series. Owner s Manual. Full Color Touch Screen Display. and Installation Instructions. High Resolution Digital Thermostat

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

5+2 Day. up to HEAT COOL

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

PRO Installation. Touch Wi-Fi Thermostat

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Installation Instructions

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

COMMERCIAL. model SFTHCP742WFC. Premier Series Digital Thermostat. Programmable. Owner s Manual. and Installation Instructions

Safety & Installation Instructions

WARNING Important Safety Information

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

PRO Installation. Touch Wi-Fi Thermostat

ATP21W02 CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS REMOVING OLD THERMOSTAT 2 THERMOSTAT DETAILS

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

WARNING Important Safety Information

Operator: Save these instructions for future use!

Smart Temp. ApolloP/n Installation Manual. Version 1.0

PRO Installation. Thermostat Wi-Fi

SC Installation, Operation & Application Guide

Programmable 5-2 Day Digital Thermostat

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

INSTRUCTION MANUAL P Heating and 1 Cooling

SC Installation, Operation & Application Guide

HEAT COOL. Meets Commercial California Title 24

CT500 Electronic Thermostat

WARNING Important Safety Information

Installation, Start-Up, and Operating Instructions

OWNER S MANUAL Venstar Inc. 08/07

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

SC Installation, Operation & Application Guide

Safety & Installation Instructions

Installation Instructions

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

INSTRUCTION MANUAL P Heating and 2 Cooling with Humidification and De-humdification

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

tcu.z Commercial Programmable Thermostat Installation Instructions

Installation, Start-Up, and Operating Instructions

Installation Instructions

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

OWNER S MANUAL Venstar Inc. 08/07

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

1F98EZ-1421, Easy Install

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Safety & Installation Instructions

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

Safety & Installation Instructions

Transcription:

OWNER'S MANUAL P/N P374-2200 Installation Instructions 70 AUTO TOTALINE 72 COOL o HEAT o 69 Meets California Title 24 Use with most Air Conditioning & Heating Systems including: 1 or 2 Stage * Electric Cooling & Gas Heating, Heat Pump, Electric or Hydronic Heat. TOTALINE Commercial Systems & Services Carrier Corporation 01/03

Table Of Contents PREPARATION REMOVE OLD THERMOSTAT WIRE CONNECTIONS WIRING DIAGRAMS Gas or Electric Heat Commercial Heat Pump Residential Heat Pump CALIBRATION TEST OPERATION TROUBLESHOOTING 2 3 4 6 10 11 12 12 13 CAUTION Follow Installation Instructions carefully. DISCONNECT POWER TO THE HEATER - AIR CONDITIONER BEFORE REMOVING THE OLD THERMOSTAT AND INSTALLING THE NEW THERMOSTAT. WARNING Replacement Component Division Carrier Corporation 01/03 Page 1

STEP #1 PREPARATION Proper installation of the thermostat will be accomplished by following these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance. Assemble tools Flat Blade Screwdriver Wire cutter & Stripper Make sure your Heater/Air Conditioner is working properly before beginning installation of the thermostat. Carefully unpack the thermostat. Save the screws, bracket, and instructions. Turn off the power to the Heating/Air Conditioning system at the main fuse panel. Most residential systems have a separate breaker for disconnecting power to the furnace. Page 2

STEP #2 REMOVE & REPLACE OLD THERMOSTAT Remove the cover of the old thermostat. If it does not come off easily check for screws. Loosen the screws holding the thermostat base or subbase to the wall, and lift away. Disconnect the wires from the old thermostat. Tape the ends of the wires as you disconnect them, and mark them with the letter of the terminal for easy reconnection to the new thermostat. Keep the old thermostat for reference purposes, until your new thermostat is functioning properly. Page 3

STEP #3 WIRE CONNECTIONS If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below, or the wiring diagrams that follow. Wire from the old thermostat terminal marked Function Install on the new thermostat connector marked G or F Fan G Y1, Y or C Cooling Y1 W1, W or H Heating W1,O,B Rh, R, M, Vr, A Power R C Common C * O/B Rev. Valve W1,O,B** 2nd Stage Heat 2nd Stage Cool RS+5 Remote Sensor +5vdc RS RS G CK1 CK2 Remote Sensor Signal Remote Sensor Ground Dry Contact Switch 1 Dry Contact Switch 2 * C may not be used on all systems. ** O/B is used if your system is a Heat Pump. Page 4

Sample Wiring Diagrams 5 Wire, 1 Stage Cooling, 1 Stage Heat Gas or Electric Heat Residential Gas or Electric Heat *, Electric Cool, split systems & package units W1/O/B Y1 G R C 5 Conductor 18 gauge unshielded cable from the thermostat to the equipment. 24 vac common 24 vac return fan relay 1st stage heat circuit W1 Y1 G R C * If using electric heat this option must be selected on during advanced setup. Page 5

Sample Wiring Diagrams 4 Wire, 1 Stage Cooling, 1 Stage Heat Gas or Electric Heat Residential Gas or Electric Heat *, Electric Cool, split systems & package units W1/O/B Y1 G R C 4 Conductor 18 gauge unshielded cable from the thermostat to the equipment. 24 vac return fan relay 1st stage heat circuit W1 Y1 G R C Page 6 * If using electric heat this option must be selected on during advanced setup.

Sample Wiring Diagrams 6 Wire, 2 Stage Cooling, 1 Stage Heat Residential 2 Stage Cooling, with Gas or Electric Heat* Gas or Electric Heat * If using electric heat this option must be selected on during advanced setup. W1/O/B Y1 G R C 6 Conductor 18 gauge unshielded cable from the thermostat to the equipment. 24 vac common 24 vac return fan relay 1st stage heat circuit W1 Y1 G R C 2nd stage Page 7

Sample Wiring Diagrams 6 Wire, 1 Stage Cooling, 2 Stage Heat Residential & commercial 1 Stage Cooling, with 2 stage Gas or Electric Heat* Gas or Electric Heat * If using electric heat this option must be selected on during advanced setup. W1/O/B Y1 G R C 6 Conductor 18 gauge unshielded cable from the thermostat to the equipment. 24 vac common 24 vac return fan relay 1st stage heat circuit 2nd stage heat circuit relay W1 Y1 G R C Page 8

Sample Wiring Diagrams 7 Wire, 2 Stage Cooling, 2 Stage Heat* Commercial Gas or Electric Heat ***, Electric Cool, split systems & package units including Commercial Heat Pumps ** Gas or Electric Heat * If using electric heat this option must be selected on during advanced setup. ** Commercial heat pumps do not have the heat pump turned on in advanced setup. *** If using electric heat, this option must be selected on during advanced setup. W1/O/B Y1 G R C 7 Conductor 18 gauge unshielded cable from the thermostat to the equipment. 24 vac common 24 vac return fan relay 1st stage heat circuit 2nd stage heat circuit relay 2nd stage W1 Y1 G R C Page 9

Sample Wiring Diagrams Heat Pump 5 Wire, 1 Stage Cooling, 1 Stage Heat* No auxiliary heat, commercial Heat Pumps, split systems & package units. W1/O/B Y1 G R C 5 Conductor 18 gauge unshielded cable from the thermostat to the equipment. 24 vac common 24 vac return fan relay reversing valve W1 Y1 G R C Page 10 * Most commerical heat pumps do not have the heat pump turned on in advanced setup. If using residential heat pump, this option must be selected on during advanced setup.

Sample Wiring Diagrams 6 Wire, 1 Stage Cooling, 2 Stage Heat Most residential split and package heat pumps with auxiliary heat Heat Pump * The heat pump option must be selected on during advanced setup. W1/O/B Y1 G R C 6 Conductor 18 gauge unshielded cable from the thermostat to the equipment. 24 vac common 24 vac return fan relay reversing valve 2nd stage heat circuit relay W1 Y1 G R C Page 11

CALIBRATION Every thermostat is calibrated before it leaves the factory. Under normal circumstances there will never be a need to recalibrate the thermostat again. To accommodate special needs, the thermostat may be recalibrated following these steps: 1. While holding the mode button in, press the fan button for 5 seconds. After all the icons in the display appear, release the buttons. 2. Press the Up and Down buttons simultaneously, twice. 3. Press the up or down buttons until the flashing number equals the current room temperature. 4. Press the mode button to return to normal operation. STEP #4 TEST OPERATION Turn the power on to the Heating/Air Conditioning system. Press the MODE button repeatedly until the HEAT icon appears on the display. Press the Up or Down buttons until the set temperature is 10 degrees above room temperature. The furnace should turn on. Page 12

TROUBLESHOOTING Press the MODE button repeatedly until the COOL icon appears on the display. Press the Up or Down buttons until the set temperature is 10 degrees below room temperature. The air conditioner should turn on. NOTE: Most equipment has a time delay of 5 minutes between cool cycles. This feature is defeatable on the thermostat. Consult the Owner's Manual under Setup, cycles per hour. Press the MODE button repeatedly until the HEAT icon appears on the display. Press the FAN button to Fan On. The fan should turn on and run continuously. SYMPTOM: When using 4 wires (R, G, W, Y), the air conditioning equipment tries repeatedly to turn on, but cannot. At times the display dims or disappears. CAUSE: There is not enough power available to "power share". REMEDY: Connect a 270 ohm, 10 watt power resistor at the furnace as shown below. For Problem A/C For Problem Heat R G W Y C R G W Y C TR300-10w TR300-10w Page 13

TROUBLESHOOTING SYMPTOM: The air conditioning does not attempt to turn on. CAUSE: The compressor timer lockout may prevent the air conditioner from turning on, for a period of time. REMEDY: Consult the Owner's Manual in the Setup section to defeat the cycles per hour and compressor timeguard. SYMPTOM: The display is blank. CAUSE: Lack of proper power. REMEDY: Make sure power is turned on to the furnace and that you have 24vac between R & W. If C is used, 24vac between R & C. SYMPTOM: The air conditioning does not attempt to turn on. CAUSE: The cooling setpoint is set too high. REMEDY: Consult the Owner's Manual in the Setup section to lower the cooling setpoint limit. SYMPTOM: The heating does not attempt to turn on. CAUSE: The heating setpoint is set too low. REMEDY: Consult the Owner's Manual in the Setup section to raise the heating setpoint limit. Page 14

TROUBLESHOOTING SYMPTOM: When controlling a residential heat pump, and asking for cooling, the heat comes on. CAUSE: Heat pump is not selected "on" in the Advanced Setup. REMEDY: Select heat pump on during Advanced Setup programming. Consult the Owner's Manual. SYMPTOM: When calling for cooling, both the heat and cool come on. CAUSE: The Advanced Setup is configured to control a heat pump, and the hvac the thermostat is controlling is a "conventional" (non heat pump) system. REMEDY: Consult the Owner's Manual in the Advanced Setup section to turn off the heat pump. Slimline P374-2200 FCc Tested to Comply with FCC Standards FOR HOME OR OFFICE USE 4Z95 Page 15 P/N 88-410 Rev. 1