Ultraviolet Lights on Daikin Applied Rooftop Systems and Rooftop Air Handlers

Similar documents
ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

WARNING WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

UV100A Ultraviolet System

UV100E Ultraviolet Air Treatment System

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

UVIOOAUltravioletSystem

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

GRU-V Air Purifier. Product Manual

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc.

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

UV Lamp and Quartz Sleeve Replacement/Maintenance

Flame Simulator User Manual. Publication Rev. A

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

PCO/UV N-Duct Model. Owner s Guide

IMPORTANT INSTRUCTIONS OPERATING MANUAL

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

AIR PURIFIER WITH GERMICIDAL UV LIGHT

Safety Manual Section 15 Radiation Safety

HEALTHY HOME AIR PURIFICATION SYSTEM

Model AD30-2. Document No B3 Revised November Atlantic Ultraviolet Corporation

ALL-IN-ONE SF PF312 MAR PMAX All-In-One Instructions.indd 1 3/1/2017 9:20 AM

Instruction Sheet DANGER

Instruction Sheet DANGER

IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER

Rainsoft Division of Aquion, Inc East Lunt Avenue Elk Grove Village, Illinois or

SLT-Series Installation and maintenance instructions

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Ultraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual

PRECISION PRECISION. Installation and Operating Instructions FLOW. AUTOMATIC REGULATOR

AIR PURIFICATION SYSTEM

Model CWA200 Owner s Manual

Document No B1 February Atlantic Ultraviolet Corporation

owner s guide TPP201M uv germicidal air purifier TPP201M uv germicidal air purifier

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

CURE ZONE 2 (#A )

The Role of Air Handling Units in Combating the Spread of Infectious Disease

by Owner s Manual For use with model: AA250 For safety and to ensure proper use carefully read the contents of this manual before operating the unit.

Prizmatix UV Torch. User Manual

ASG EZ-9000GR Tape Dispenser User Manual ASG #66136

Instruction Sheet. VIQUA UVMAX Lamp and Quartz Sleeve Replacement

Cleans and sanitizes CPAP mask and accessories. Lumin USER MANUAL.

SERVICE REQUIREMENTS

owner s guide TPP uv germicidal air purifier TPP230 uv germicidal air purifier

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

AirPurification System

Document No A3 Revised February Atlantic Ultraviolet Corporation

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

MULTI-TECH II INSTRUCTION MANUAL. Model XJ-3000D

Air Cleaning System USE & CARE INSTRUCTIONS. Model No. AC4300BPT 3-Year Limited Warranty

Nicholas Harmon President, Verilux, Inc.

SERVICE & TROUBLESHOOTING MANUAL FOR DISPLAY HOLD CABINETS DHC SERIES

SimplyClear Pressurized Filter Product Manual

HEALTHY HOME SYSTEM CONTROL Plus Model: HHSC+

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 0905 FAOM15_0905

USE & CARE INSTRUCTIONS

or

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

OPERATION & INSTALLATION MANUAL AIR PURIFICATION SYSTEM (APS300)

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Owner s Manual. Airgle Personal Air Purifier ( Model: AG25 )

Important Safety Instructions

FLAME CUBE ELECTRIC FIREPLACE MODEL EF-BLT02 OPERATION MANUAL

UVC in the Operating Room.

SERVICE PARTS/OPERATION for

A measured step forward

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 02_04 FA SP-ENG OM - 02_04

Ultraviolet (UV) Monitoring System - Open Channel Horizontal Systems Operation and Maintenance Manual

RoofPak Applied Rooftop Systems

Document No A9 Revised August Atlantic Ultraviolet Corporation

EQUIPMENT OPERATION MANUAL. Loctite High Intensity Ultraviolet Source

UVC 500 Ultraviolet Crosslinker

NANO TECH UV-C DISINFECTION SYSTEM

I N S T A L L A T I O N, O P E R A T I O N, M A I N T E N A N C E M A N U A L UVR SERIES ULTRAVIOLET WATER TREATMENT SYSTEM

owner s guide TPP230H uv air purifier TPP230H uv air purifier

Safety Information Contents List Odorox Boss XL3 Unit Operational Guidelines Operating The Odorox Boss XL3... 4

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

Dogeroo & Super Dogeroo

Daikin Direct Expansion (DX) Cooling Coils

Unit 3 Machine Composition

Supply air hood JSI-UV Installation-, adjustment and user guide

February Guide to using germicidal UV. Part of the the Search, Treat, Prevent Comprehensive Approach for TB

1020 Industrial Drive, Orlinda, TN fax

ANTIBACTERIAL HAND VAC

NEW GREEN SERIES INSTALLATION AND OPERATION SP-150GS SP-200GS. Manufactured by ULTRA-SUN TECHNOLOGIES, INC Stellar Court Corona, CA 92883

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

PRE INSTALLATION PROCEDURES

IMPORTANT SAFETY INSTRUCTIONS

REGISTERED HANDBOOK. Document: ECN: Revision: C. MANUAL, O&M TrojanUVLogic TM System Systems Without Wiper AM, VM & TM Models

Product Brief. specification. UV Module Solution. Description. Features and Benefits. Key Applications CMW-PS-C01. Table 1.

CA3500, BA3500, CH3500 New Comfort

Installation and Maintenance Manual IM 1038

Connevans. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Instruction Manual FEEL THE ENERGY. FEEL THE FRESHNESS.

Operator Preventive Maintenance

Transcription:

Installation and Maintenance Manual Group: Applied Systems Part Number: IM790 Date: June 2004 Ultraviolet Lights on Daikin Applied Rooftop Systems and Rooftop Air Handlers Models RPS/RDT/RFS/RPE/RDE/RDS/RAH 2004 Daikin Applied Page 1

Table of Contents Introduction... 2 Description... 2 Operation... 3 Maintenance... 4 Bulb Replacement... 4 Typical Parts List... 4 Introduction This manual provides general information about the Ultraviolet Light option for Daikin RoofPak applied rooftop models RPS/RDT/RFS/RPE/RDE/RDS and RAH. In addition to an overall description of the unit, it includes removal and installation procedures, maintenance instructions and parts identification. Hazard Identification Information Warnings indicate hazardous situations which, if not avoided, can result in severe personal injury or property damage. UVC exposure is harmful to the skin and eyes. Looking at an illuminated bulb can cause permanent blindness. Skin exposure can cause Cancer. Always disconnect power to unit before servicing. Do not operate if disconnect switch has been disabled. Figure 1. Typical Ultraviolet Light Installation CCAUTION Cautions indicate hazardous situations which, if not avoided, can result in personal injury or equipment damage. Description Ultraviolet C light bathes the moist surfaces on the coil and drain pan, killing most microorganisms that can grow there. Cooling Coil Light Power Disconnect Switch Ultraviolet lights are typically installed on the leaving side of the cooling coils in the unit. Each light module is mounted on a rail and is removable for convenient bulb replacement. UV Light Power Disconnect switches (two per door) are factory installed on every door that allows a direct line of sight to the UV lamps when opened. These switches are designed to prevent UV exposure when cabinet doors are opened and must not be disabled. View Window AIRFLOW Ultraviolet Light Units Light Power Disconnect Switch A viewing window near the UV lights allows viewing to determine if the lights are energized. The viewing windows use specially designed glass that blocks harmful UV light. Page 2

Operation Refer to the Wiring Schematic below. 115 VAC power for the UV lights is provided by control circuit transformer T1. The lights operate whenever the unit is powered, system switch S1 is closed, and all doors with door power disconnect switches are closed. To turn the lights off, disconnect power to the entire unit, or open system switch S1. Figure 2. Typical Ultraviolet Light Wiring Schematic The normally open disconnect switches are wired in series in a circuit that supplies 24VAC to the coil of relay R45. When all doors are closed, relay R45 is energized, and its normally open contacts (in series with system switch S1) provide 115VAC to the UV lights. Page 3

Maintenance Bulb Replacement Replace all bulbs every 12 months regardless of their condition. Refer to the manufacturer s suggested replacement interval. NOTE: A glowing lamp indicates only that the UV light is powered, not that it is emitting the necessary UVC wavelength for germicidal effect. Disconnect power to the unit before servicing. Verify the power has been disconnected. Before opening the doors, use the viewing window to make sure the UV lights are off. Florescent bulbs contain mercury, which can cause personal injury if breathed or ingested. Use appropriate protective gear to clean up broken bulbs. Figure 4. Removing Lamp Units - Step 2 Disconnect Power Receptacle from Lamp Unit Figure 5. Removing Lamp Units - Step 3 Personal Injury Hazard. Power supply can cause electrical shock. Always disconnect power to unit before servicing. UVC exposure is harmful to the skin and eyes. Looking at an illuminated bulb can cause permanent blindness. Skin exposure can cause Cancer. Verify the UV lights are off by using the view window. Remove Lamp Units Do not open modular UV Lamp units. There are no user serviceable components inside. 1. Allow lamps to cool for 5 minutes before handling. 2. Unplug the power receptacle from the row of lamps by pulling it apart from the lamp unit and sliding the receptacle off the rail. 3. Carefully slide the lamp units off the rail. Use the slots in the rail if needed to help in removal. Place the lamp unit on a flat surface. Figure 3. Removing Lamp Units - Step 1 Lamp Unit Removing Bulbs 1. Allow bulbs to cool for 5 minutes before handling. 2. Grasp body of bulb firmly at each end. 3. Rotate bulb 90 degrees in either direction. 4. Remove bulb. 5. Reverse process to install replacement bulb. 6. Wipe down bulb with clean cloth and alcohol. Avoid touching bulb as fingerprints can degrade performance. 7. Dispose of removed bulbs in accordance with local environmental regulations. Replacement Parts List Daikin PN Pull Lamp Unit Up and Away from Rail and Remove Description 033696300 Power Disconnect Switch 205484001 18 in. Lamp Holder 205484101 24 in. Lamp Holder 205484201 36 in. Lamp Holder 205485501 Hard Wire Module 205484501 18 in. Lamp 205484601 24 in. Lamp 205484701 36 in. Lamp Power Receptacle Page 4

This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.daikinapplied.com. 2004 Daikin Applied www.daikinapplied.com 800-432-1342