Oak Park Dr., Unit A, Mooresville, NC OVER 60 YEARS OF INNOVATION Product Guide

COLD PLASMA CLEAN KILL GERMS WHILE DRYING HANDS WITH AMERICAN DRYER S NEW PATENT-PENDING COLD PLASMA CLEAN TECHNOLOGY 2014 PRODUCT GUIDE

DR Series PUSH BUTTON & AUTOMATIC STEEL HAND & HAIR DRYER TECHNICAL SPECIFICATIONS

SECTION ELECTRIC HAND DRYERS

SECTION ELECTRIC HAND DRYERS. ** NOTE TO SPECIFIER ** Excel Dryer, Inc.; Electric Hand Dryers.

The Finest Hand And Hair Dryers Available

THE MOST ENERGY EFFICIENT HAND DRYER ON THE PLANET

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

SECTION COMMERCIAL-KITCHEN HOODS

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

SECTION AIR DOORS

reach for the top hand dryers SHDL series

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

reach for the top hand dryers 2016 eln series lan series SHDL series

Hand Dryers Airforce - pg 3

GREEN GUIDE. Comparison of Energy per Use 285,668 ANNUAL SAVINGS 233 KJ GREEN FACTS GREEN CERTIFICATIONS ENERGY REDUCTION COST SAVINGS

SUBMITTAL SCHEDULE & DATA

ARCHITECTURAL SPECIFICATIONS

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

ASI Guide Specification

Hand Dryers / WOR BUYLINE Hand Dryer Benefits Planning Guide - pg 1. Airforce - pg 2. AirMax - pg 3. Model A Series - pg 4

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

SECTION GENERATOR PARALLELING CONTROLS

UFGS (August 2008) UFGS (January 2007) UNIFIED FACILITIES GUIDE SPECIFICATIONS

MacroAir AirElite HVLS Fans

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION WATER-SOURCE UNITARY HEAT PUMPS

SECTION ROTARY-SCREW WATER CHILLERS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION ISOLATED POWER SYSTEMS

SECTION COMPRESSED-AIR EQUIPMENT FOR LABORATORY FACILITIES

Partitions. Accessories. Lockers. No-Touch Washroom Accessories

Construction Standards Page

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

Engineering Specifications

SECTION AIR DUCT ACCESSORIES

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

SECTION INTRUSION DETECTION SYSTEM

UFGS (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

MacroAir AirSpan HVLS Fans

A. This Section includes the following emergency plumbing fixtures:

HAND DRYERS

MacroAir AirVolution HVLS Fans

.2 Section Waste Management and Disposal..4 Section Electrical General Requirements.

MacroAir by Blue Giant AirVolution HVLS Fans

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

SECTION Overhead Coiling Doors

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Copyright 2011 AIA MasterSpec Full Length 06/11 PRODUCT MASTERSPEC LICENSED BY ARCOM TO CALCANA USA LTD.

DIVISION 10 SPECIALTIES

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

SECTION OVERHEAD COILING FIRE DOORS

Hot Air Hand Dryer Range

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

HUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters

SECTION XPRESS II INCLINED WHEELCHAIR PLATFORM LIFT. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

INSTANT-FLOW C-MICRO WATER HEATER

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

SECTION CUSTOM FABRICATED FOODSERVICE EQUIPMENT

Slimline, Energy Saving & Smart. It's the game changer!

SECTION HVAC Fans

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

BLG77 Rising Fenced Barrier

SECTION HVAC Fans

B. Section Identification for Fire Suppression Piping and Equipment.

INSTALLATION and OPERATION INSTRUCTIONS

Product Guide Specification

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

CR1 Series Triton Corrosion Resistant Washdown Heaters

SECTION AIR CURTAINS

PALMER FIXTURE FULL LINE PRODUCT CATALOG

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

Design and Construction Standards SECTION PLUMBING EQUIPMENT

INSTANT-FLOW C-MICRO WATER HEATER

SECTION STEAM CONDENSATE PUMPS

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

RP SERIES THERMAL PROTECTORS

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

SSB. S CLASS SPLIT SYSTEM R 410A Two Stage Compressor 60 HZ A I R C O N D I T I O N E R S

SECTION FIRE ALARM SYSTEMS

The Complete Range of Hand Dryers

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

Transcription:

Architectural 3-Part Specifications (Specifier Note: The purpose of this guide specification is to assist the Specifier in correctly specifying American Dryer electric hand dryers and their installation. The Specifier needs to edit these guide specifications to fit the needs of each specific project. References have been made within the text of the specification to MasterFormat Section numbers and titles. The Specifier needs to coordinate these numbers and titles with sections included for the specific project. Throughout the guide specification, there are Specifier Notes to assist in the editing of the file. Brackets have been used to indicate when a selection is required. Unless otherwise noted, the first option is the standard feature. American Dryer offers five different models to suit every project. The EXTREMEAIR is THE HIGH SPEED HAND DRYER FOR THE NEXT GENERATION. Features include Cold Plasma Clean TM Technology for sanitizing (CPC SERIES Only) Adjustable Sound and Speed and Universal Voltage. Specify the CPC SERIES for sanitizing and drying. Specify the GXT SERIES for the fastest performance or the EXT SERIES for more energy efficiency. The new ADVANTAGE SERIES HAND DRYERS the perfect replacement for the traditional dryer with more power and features in a heavy duty, compact and vandal-resistant package. The GX SERIES AUTOMATIC HAND DRYERS provide a quiet and compact design to fit any budget. Contact an American Dryer representative for further assistance with appropriate product selections.) SECTION 10 28 40 HAND DRYERS American Dryer EXTREMEAIR CPC SERIES American Dryer EXTREMEAIR GXT SERIES American Dryer EXTREMEAIR EXT SERIES American Dryer ADVANTAGE AD SERIES American Dryer GLOBAL GX SERIES PART 1 - GENERAL 1.1 SECTION INCLUDES A. Warm-air dryers. 1.2 REFERENCES A. Underwriters Laboratories, Inc. (UL for USA and C-UL for Canada) 1. UL 499; UL Standard for Safety Electric Heating Appliances 2. CSA C22.2 Canadian Standard for Hair Dressing Equipment 3. UL867 Standard for Electrostatic Air Cleaners (EXTREMEAIR CPC SERIES) 4. California Air Resource Board, CARB (EXTREMEAIR CPC SERIES) Revised November 18, 2013 10 28 40-1 HAND DRYERS

1.3 ACTION SUBMITTALS A. Refer to Section [01 33 00 Submittal Procedures] [Insert section number and title]. B. Product Data: For each type of dryer indicated, including written installation instructions. (Specifier Note: DELETE LEED Submittals paragraph and subparagraph below if not project specific.) C. LEED Submittals: 1. Product Data for Credit EA1: For motor energy usage calculations. D. Shop Drawings: Include dimensions, method of attachment, and electrical wiring. E. Samples: Provide finish samples for each finish required. F. Warranty: Sample of special warranty. 1.4 CLOSEOUT SUBMITTALS A. Refer to Section [01 78 00 Closeout Submittals] [Insert section number and title]. B. Maintenance data. 1.5 QUALITY ASSURANCE A. Dryers: Listed per UL 499 and CSA C22.2 and shall bear UL and C-UL label. 1.6 DELIVERY, STORAGE AND HANDLING A. Refer to Section [01 60 00 Product Requirements] [Insert section number and title]. B. Deliver dryers and components in manufacturer s original, unopened, undamaged containers with identification labels intact. C. Store dryers as recommended by manufacturer. 1.7 WARRANTY A. Refer to Section [01 78 36 Warranties] [Insert section number and title]. Revised November 18, 2013 10 28 40-2 HAND DRYERS

B. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of dryers that fail in materials or workmanship within specified warranty period. (Specifier Note: SELECT five year warranty when EXTREMEAIR models are specified. SELECT five year warranty when American ADVANTAGE series is specified. SELECT three year warranty when the Global GX series is specified. 1. Warranty Period: [5] [3] years. PART 2 - PRODUCTS (Specifier Note: Product Information is proprietary to American Dryer. If additional products are required for competitive procurement, contact American Dryer for assistance in listing competitive products that may be available.) 2.1 MANUFACTURER A. American Dryer, Inc.; 33067 Industrial Road; Livonia, MI 48150, USA; Phone 734.421.2400, fax 734.421.5580; Toll free 800.485.7003; website www.americandryer.com. Email: sales@americandryer.com. (Specifier Note: DELETE paragraph below when substitutions are not allowed.) 1. Subject to compliance with requirements, manufacturers of products of equivalent design may be acceptable if approved in accordance with [Section 01 25 00 Substitution Procedures] [Insert section number and title]. 2.2 WARM-AIR DRYERS (Specifier Note: RETAIN paragraph and sub-paragraphs below when specifying EXTREMEAIR CPC.) A. Automatic, High Speed, Cold Plasma Clean Dryer & Sanitizer [Insert drawing designation] 1. Basis-of-Design Product: American Dryer s EXTREMEAIR CPC SERIES. 2. Cold Plasma Clean Technology dryer and sanitizer 3. Proven to kill up to 99.6% of pathogens on hands 4. Adjustable Speed: 10 + seconds 5. Adjustable Sound Level: 83-69 db 6. Universal Voltage 110-120/208/220-240 Volts, 50/60 Hz, 1500 W Max. 7. Motor: 5/8 HP, 24,000 14,000 RPM adjustable, commutated through-flow discharge vacuum motor/blower with automatic resetting thermal protector. 8. Adjustable Air Velocity: 19,000 10,000 LFM Revised November 18, 2013 10 28 40-3 HAND DRYERS

9. Air Temperature: 135 F 10. Energy Usage: 51 KJ 11. Mounting: Surface mounted 12. Operation: Automatic, microprocessor-controlled infrared-sensor activated a. Maximum Operation Time: 35 seconds. 13. Cover Material and Finish: [Flame retardant ABS polymer, with white finish] [Steel, with white epoxy finish] [Steel, with black graphite epoxy finish][steel, with satin chrome finish] [Stainless steel, with no. 4 brushed finish]. (Specifier Note: Supply with 110-120V when better efficiency is desired. Standby power with 120V supply consumes 1W versus 4W when 240V is supplied. 120V is also a more standard voltage. COORDINATE project electrical requirements with electrical engineer.) 14. Electrical Requirements: Universal Voltage automatically configures the dryer to operate on 110-120/208/220-240V, 50/60Hz, 1500 W Max. (Adjustable 1500 W to 800 W) (Specifier Note: ADD wall guard part no. ADA-WG below where ADA requirements limit below to semi-recess the dryer into the wall where ADA requirements limit hand dryer 15. ADA Accessories [None] [ADA-WG Wall Guard] [ADA-RK Recess Kit (Specifier Note: RETAIN paragraph and sub-paragraphs below when specifying EXTREMEAIR GXT.) B. Automatic, High Speed, Warm-Air Dryer [Insert drawing designation] 1. Basis-of-Design Product: American Dryer s EXTREMEAIR GXT SERIES. 2. Adjustable Speed: 10 + seconds 3. Adjustable Sound Level: 83-69 db 4. Universal Voltage 110-120/208/220-240 Volts, 50/60 Hz, 1500 W Max. 5. Motor: 5/8 HP, 24,000 14,000 RPM adjustable, commutated through-flow discharge vacuum motor/blower with automatic resetting thermal protector. 6. Adjustable Air Velocity: 19,000 10,000 LFM 7. Air Temperature: 135 F 8. Energy Usage: 51 KJ 9. Mounting: Surface mounted 10. Operation: Automatic, microprocessor-controlled infrared-sensor activated a. Maximum Operation Time: 35 seconds. Revised November 18, 2013 10 28 40-4 HAND DRYERS

11. Cover Material and Finish: [Flame retardant ABS polymer, with white finish] [Steel, with white epoxy finish] [Steel, with black graphite epoxy finish][steel, with satin chrome finish] [Stainless steel, with no. 4 brushed finish]. (Specifier Note: Supply with 110-120V when better efficiency is desired. Standby power with 120V supply consumes 1W versus 4W when 240V is supplied. 120V is also a more standard voltage. COORDINATE project electrical requirements with electrical engineer.) 12. Electrical Requirements: Universal Voltage automatically configures the dryer to operate on 110-120/208/220-240V, 50/60Hz, 1500 W Max. (Adjustable 1500 W to 800 W) (Specifier Note: ADD wall guard part no. ADA-WG below where ADA requirements limit below to semi-recess the dryer into the wall where ADA requirements limit hand dryer 13. ADA Accessories [None] [ADA-WG Wall Guard] [ADA-RK Recess Kit] (Specifier Note: RETAIN paragraph and sub-paragraphs below when specifying EXTREMEAIR EXT series.) C. Automatic, High Speed, Warm-Air Dryer [Insert drawing designation] 1. Basis-of-Design Product: American Dryer s EXTREMEAIR EXT SERIES. 2. Adjustable Speed: 12 + seconds 3. Adjustable Sound Level: 83-69 db 4. Universal Voltage 110-120/208/220-240 Volts, 50/60 Hz, 540 W Max. 5. Motor: 5/8 HP, 24,000 14,000 RPM adjustable, commutated through-flow discharge vacuum motor/blower with automatic resetting thermal protector. 6. Adjustable Air Velocity: 19,000 10,000 LFM 7. Air Temperature: 85 F 8. Energy Usage: 22 KJ 9. Mounting: Surface mounted 10. Operation: Automatic, microprocessor controlled infrared-sensor activated a. Maximum Operation Time: 35 seconds. 11. Cover Material and Finish: [Flame retardant ABS polymer, with white finish] [Steel, with white epoxy finish] [Steel, with black graphite epoxy finish] [Steel, with satin chrome finish] [Stainless steel, with no. 4 brushed finish]. Revised November 18, 2013 10 28 40-5 HAND DRYERS

(Specifier Note: Supply with 110-120V when better efficiency is desired. Standby power with 120V supply consumes 1W versus 4W when 240V is supplied. 120V is also a more standard voltage. COORDINATE project electrical requirements with electrical engineer.) 12. Electrical Requirements: Universal Voltage automatically configures the dryer to operate on 110-120/208/220-240V, 50/60Hz, 540 W Max. (Adjustable 540 W to 300 W) (Specifier Note: ADD wall guard part no. ADA-WG below where ADA requirements limit below to semi recess the dryer into the wall where ADA requirements limit hand dryer 13. ADA Accessories [None] [ADA-WG Wall Guard] [ADA-RK Recess Kit] (Specifier Note: RETAIN paragraph and sub-paragraphs below when specifying American ADVANTAGE series.) A. Automatic, Warm-Air Dryer [Insert drawing designation] 1. Basis of Design: American Dryer s ADVANTAGE AD series. 2. Drying Time: 25 seconds 3. Energy Usage: 128 KJ 4. Universal Voltage 110-120/208/220-240 Volts, 50/60 Hz, 1500 W Max. 5. Motor: 1/8 HP, 4,800 RPM automatic thermal protector. 6. Air Flow: 180 CFM 7. Air Velocity: 7,300 LFM 8. Sound Level: 67 db 9. Heating Element: NiChrome resistance wire 10. Air Temperature: 120 F at 72 F ambient 11. Mounting: Surface mounted 12. Operation: Automatic, microprocessor controlled infrared-sensor activated a. Hand Dryer Maximum Operation Time: 35 seconds. b. HAIR Dryer Maximum Operation Time: 80 seconds. 13. Cover Material and Finish: [Flame retardant ABS polymer, with white finish] [Steel, with white epoxy finish] [Steel, with black graphite epoxy finish] [Steel, with satin chrome finish] [Stainless steel, with no. 4 brushed finish]. (Specifier Note: Supply with 110-120V when better efficiency is desired. Standby power with 120V supply consumes 1W versus 4W when 240V is supplied. 120V is also a more standard voltage. COORDINATE project electrical requirements with electrical engineer.) 14. Electrical Requirements: Universal Voltage automatically configures the dryer to operate on 110-120/208/220-240V, 50/60Hz, 1500 W Max. Revised November 18, 2013 10 28 40-6 HAND DRYERS

(Specifier Note: ADD wall guard part no. ADA-WG below where ADA requirements limit below to semi recess the dryer into the wall where ADA requirements limit hand dryer 15. ADA Accessories [None] [ADA-WG Wall Guard] [ADA-RK Recess Kit] (Specifier Note: RETAIN paragraph and sub-paragraphs below when specifying GLOBAL GX series.) A. Automatic, Warm-Air Dryer [Insert drawing designation] 1. Basis of Design: American Dryer s GLOBAL GX series. 2. Drying Time: 40 seconds 3. Energy Usage: 153 KJ 4. Motor: 1/12 HP, 3,100 RPM, permanently lubricated, maintenance free, brushless induction motor with automatic resetting thermal protector. 5. Air Flow: 120 CFM 6. Air Velocity: 4,000 LFM 7. Sound Level: 63 db 8. Heating Element: NiChrome resistance wire 9. Air Temperature: 120 F at 72 F ambient 10. Mounting: Surface mounted 11. Operation: Automatic, microprocessor controlled infrared-sensor activated a. Maximum Operation Time: 60 seconds. 12. Cover Material and Finish: One-piece, [heavy duty, flame retardant ABS polymer, with white finish] [18 gauge steel, with electrostatically applied, chip-resistant white epoxy finish] [18 gauge steel, with electrostatically applied chip resistant black graphite epoxy finish] [18 gauge steel, with chrome-plated satin finish]. (Specifier Note: SELECT 110-120V option when better efficiency is desired. Standby power on the 120V model consumes 1W versus 4W on 240V models.120v is also a more standard voltage. COORDINATE project electrical requirements with electrical engineer.) 13. Electrical Requirements: [110-120 V, 12 A, 1500 W, 50/60 H] [208-240 V, 6 A, 1500 W, 50/60 H]. (Specifier Note: ADD wall guard part no. ADA-WG below where ADA requirements limit below to semi recess the dryer into the wall where ADA requirements limit hand dryer 14. ADA Accessories [None] [ADA-WG Wall Guard] [ADA-RK Recess Kit] Revised November 18, 2013 10 28 40-7 HAND DRYERS

PART 3 EXECUTION 3.1 GENERAL A. Install hand dryers in accordance with manufacturer s installation guidelines and recommendations. 3.2 PREPARATION A Verify substrates have been properly prepared. B. Coordinate location and installation of electric hand dryers with blocking and other fixtures. 1. Verify dryers will be located at least 2 feet apart. 2. Verify dryers will be located at least 12 inches from side of washbasin. 3. Verify dryers will be located at least 18 inches above any projection which may interfere with operation of automatic sensor. C. Coordinate location and requirements for power supply, conduit, disconnect switches and wiring. 3.3 INSTALLATION A B C Install hand dryers level, plumb, and firmly anchored in locations and at heights indicated. Install hand dryers using manufacturer recommended fasteners for each substrate. Apply bead of caulk around edges of cover to wall. 3.4 PROTECTION A. Protect installed hand dryers after installation from damage during construction. If damage occurs, remove and replace damaged unit as required to provide units in their original, undamaged condition. END OF SECTION Revised November 18, 2013 10 28 40-8 HAND DRYERS