SUBMITTAL SCHEDULE & DATA

Similar documents
GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

AUGUST, High-Efficiency Condensing Gas-Fired Separated Combustion Unit Heaters

bring value to your space

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

Gas-Fired Unit Heaters Commercial & Industrial

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces

FEATURES AND BENEFITS

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

HVAC HEATING PRODUCTS

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Gas-Fired Unit Heaters Commercial & Industrial

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

GQVC-12 HVAC EQUIPMENT. GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces.

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

Work In Shirt-Sleeve Comfort When It s Doggone Cold

Gas-Fired Indoor and Outdoor Duct Furnaces

Thermal Devices, Inc. Mount Airy, Maryland USA

Industrial Air Heaters

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS

TECHNICAL SPECIFICATIONS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Gas-Fired Heating Equipment

Rheem Classic Series Multi-position Gas Furnaces

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Ruud Achiever Series Multi position Gas Furnaces

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

Multi-Position Gas Furnaces

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

HVAC HEATING PRODUCTS

MULTI POSITION GAS FURNACE

Ruud Achiever Plus Series Multi-position Gas Furnaces

RG7D 1-Stage Heat Series

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

True performance and rugged durability. TU, LF and LD Models

GA Gas Unit Heater Assemblies Technical Guide

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Direct Fired Heater Model AD Specification

Ruud Acheiver Series Upflow Gas Furnaces

G6RC Series TECHNICAL SPECIFICATIONS

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

Gas-Fired Indoor Duct Furnace Gravity and Power Vented

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Product Catalog Gas Heating Products: Indoor and Outdoor Units

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

SUH-8 UNIT HEATERS. High Efficiency Heating Equipment

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Rheem Classic Plus Series Multi position Gas Furnaces

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

GARAGE / WORKSHOP INFRARED HEATERS

MULTI POSITION GAS FURNACE

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

Multi-Position Gas Furnaces

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

U n i t H e at e r s

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

13 GEP A L P - 1 A

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

STEAM/HOT WATER UNIT HEATERS

Cabinet Unit Heaters Steam / Hot Water

MERIT SERIES Downflow

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

Transcription:

SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Date: 10/31/2016 Location: Engineer: Submitted by: Jeff Musto Architect: Contractor: Model Number HD 75AS0121FBAN Quantity of Units 1 Btu/Hr Input 75,000 Btu/Hr Output 61,500 CFM 1160 Altitude 0-2000 Temperature Rise (degrees F) 49 External Static Pressure (E.S.P) 0.00 Total Static Pressure (T.S.P.) 0.00 Gas Type Propane Gas Control Type Single Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry Supply Voltage 115/60/1 Control Voltage 24V Motor HP 1/12 Motor RPM 1625 Blower RPM N/A Heat Exchanger Type Aluminized Steel Heat Exchanger/Burner Options & Accessories (See Attached Pages) Unit Tag Remarks

SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Model Description Qty Tag HD 75AS0121FBAN Propeller Unit Heater 1 53149 HD 75AS0121FBAN 1

1,2,3 4,5,6 7 8 9,10 11,12 13 14 15 16 HD 75 A S 01 21 F B A N AccuSpec V4.6.1 HD MODEL NOMENCLATURE 1,2,3 - Product Type HD - Power Vented Propeller Unit 4,5,6 - Furnace Input Rating 75-75,000 Btu/hr Input 7 - Heat Exchanger Type A - Aluminized Steel Heat Exchanger and Burner 8 - Pilot Ignition S Direct Spark Ignition 9,10 - Motor and Drive Code (Power Code) 01-115V motor 11,12 Gas and Valve/Ignition Control Type (Control Code) 21 - Propane, Single Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 13 Fan Guard Type F - Finger Proof Fan Guard 14 Development Sequence B - Current 15 Future A For Future Use 16 Factory Installed Option N - None

GENERAL PERFORMANCE DATA General Performance Data Model HD 75 At 0 Elevation Btu/Hr. Input 75,000 Btu/Hr. Output 61,500 Entering Airflow (CFM) 1160 Outlet Velocity 769 Air Temp. Rise ( F) 48 Mounting Height (Max Ft.) 1 14 Heat Throw (Max. Mtg. Ft.) 2 38 Unit Total Power (Amps) 3.25 As Configured at 0-2000 Ft. Elevation Btu/Hr. Input 75,000 Btu/Hr. Output 61,500 Configured Air Temp Rise ( F) 49 Motor Data Horse Power 1/12 RPM 1625 Type P.S.C. Motor Amps at 115V 1.95 Clearances to Combustibles Top and Bottom 1 Vent Connector 4 Access Side 18 Non-Access Side 1 Rear 18 1 At 65 F ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit. 2 Heat Throws are calculated at 65 F ambient with a 49 F air temperature rise with the unit mounted at a maximum mounting height of 14 feet.

DIMENSIONS UNIT Model HD Dimensions Model Size HD75 Dimensions (in inches) A 26.8 B 18 C 16.5 D 14.9 E 15.9 F 10.7 G 18.5 H 7.8 I 31 J 25 Vent Connector Diameter 3 Gas Connection Diameter 1/2 Fan Diameter 14 Approx. Shipping Weight 85 lbs.

Standards All unit(s) shall include: C.S.A. (Canadian Standards Association) design certification for use in both the US and Canada to the ANSI Z83.8 - latest revision, standard for Gas Unit Heater and Gas-Fired Duct Furnaces for safe operation, construction, and performance Mechanical Configuration Furnace(s) section with 82% minimum efficiency provided by an indirect-fired tubular heat exchanger with individually fired tubes for maximum heat transfer with minimal noise of flame ignition/extinction. Venting Arrangement The venting shall be a power exhausted arrangement. The unit shall be tested to insure proper ignition when the unit is subjected to 40 mile per hour wind velocities. The unit shall also include a factory mounted differential pressure switch designed to prevent main burner ignition until positive venting has been proven. Unit Casing The unit heater(s) casing shall be constructed of not less than 22 gauge aluminized steel with minimization of exposed fasteners. All exterior casing parts shall be cleaned of all oils and a phosphate coating applied prior to painting. The exterior casing parts shall then be painted with an electrostatically applied baked-on gray-green polyester powder paint (7- mil thickness) for corrosion resistance. The unit shall be furnished with horizontal air deflectors. The deflectors are adjustable to provide for horizontal directional airflow control (up or down). Furnace Section The heat exchanger(s) shall be made of 18 gauge aluminized steel tubes and headers. The thermal efficiency of the unit(s) shall be a minimum of 82% efficient for all air flow ranges. Each heat exchanger tube shall be individually and directly flame-fired. The heat exchanger tube shall be crimped to allow for thermal expansion and contraction. The flue collector box shall be made of 20 gauge aluminized steel. The heat exchanger(s) seams and duct connections shall be certified to withstand 0.9" W.C. external static pressure without burner flame disturbance. The burner(s) shall be in-shot type, directly firing each heat exchanger tube individually and is designed for good lighting characteristics without noise of extinction for both natural and propane gas. The ignition controller(s) shall be 100% shut-off with continuous retry. The gas pressure shall be 11-14" W.C. for propane gas. The solid state ignition system shall directly light the gas by means of a direct spark igniter each time the system is energized. The unit gas controls shall be provided with the following: Single-stage gas controls with a single-stage combination gas control, an ignition control. The unit fires at 100% full fire based on a call for heat from a room thermostat.

An automatic reset high limit switch mounted in the air stream to shut off the gas supply in the event of overheating. A time delay relay that delays the start of the air mover to allow the heat exchanger a warm-up period after a call for heat. The time delay relay shall also continue the air mover operation after the thermostat has been satisfied to remove any residual heat in the heat exchanger. The unit shall be orificed for 0-2000 feet elevation above sea level. Electrical All electrical components shall carry UL, ETL, or CSA listing. A low voltage terminal board shall be provided for direct wiring connection to an external thermostat. A single 115V to 24V step down transformer shall be provided for all unit controls. Air Mover The motor horsepower shall be 1/12 H.P. The motor wiring shall be in flexible metal BX conduit. The motor shall be controlled by a time delay relay. Propeller models shall meet the following requirements: The motor type shall be Single-Speed, Open Drip Proof (ODP). The air mover motor shall be a 115V motor. Mounting The unit shall be equipped with mounting brackets to allow for threaded rod suspension or to be bolted directly to the ceiling support structure allowing 1 of top clearance. Accessories The following field installed accessory control devices shall be provided with the unit: