OCHSNER hot water heat pumps NATURAL HOT WATER

Similar documents
ECO AIR/WATER HEAT PUMP For new buildings, low-energy and passive houses

OCHSNER High-Tech heat pumps ENERGY DIRECT FROM NATURE

Heating and cooling with energy from the environment

Heating and cooling with energy from the environment

OCHSNER High-Tech heat pumps ENERGY DIRECT FROM NATURE

Committed to progress OCHSNER THE COMPANY

PRICE LIST EXPORT / April 2012

OCHSNER high tech heat pumps ENERGY FROM NATURE

Calorifier/heat pump CombiVal WPE/WPER (300)

Heat Pump Water Heater Commercial Leaflet 2012

Energy you can recycle

ROTEX HPDU monobloc Maximum efficiency in water heating

REMKO Comfort-WP The versatile heat pump

Aqua 1 plus Air-water heat pumps for domestic hot water production

AQUAHEAT ADVANCE SPLIT

Natural geothermal energy

ROTEX gas hybrid heat pump. A strong team.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

Industrial cooling systems LT

THE HEART OF YOUR COMFORT

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

New Panasonic Aquarea DHW. Domestic Hot Water Tanks

User Manual. Vanvex Optima 180 Domestic Hot Water. Version

PRODUCT DATA SHEETS HEAT PUMPS

Integrated Heat Pump Water Heater

Efficient heating that won t cost the earth

HP WH SERIES HEAT PUMP WATER HEATER. 200l 300l HP200M1, HP250M1 / HP200M3, HP250M3, HP250M3C / HP200S1, HP300S1

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

=Classic range= Classic range technologies. Magnesium anode. Sheathed heating element

Gas wall system and combination boilers. Why Vaillant? For more technology and experience. atmotec plus turbotec plus atmotec pro turbotec pro

Heat pumps. Why Vaillant? Because heating your home should be done naturally.

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

Zehnder ComfoAir 550. Ventilation unit

Press. Heat pumps from Viessmann: efficient heat generation with renewable energy and electricity

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance

Accelera Heat Pump Water Heaters HEAT PUMP WATER HEATERS

recooler HP EQKR HEAT PUMP

EXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump

REMKO HYBRID HEAT PUMPS

Systems engineering Slide 1

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

The Benefits Really Add Up

OCHSNER CO 2 heat pipes an option for vertical collectors

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

VITOSOL. Solar hot water heating systems Flat plate and vacuum tube solar collectors

Technical specifications

BWL air heat pumps BWS brine heat pumps

Ground Source Heat Pumps

Heating with pellets kw

Providing sustainable energy solutions worldwide. CTC heating boilers modern technology, efficient heating

Electricity Consume of Solar AC VS Normal AC

DHW Tanks Indirect Tanks for Domestic Hot Water. New! Single coil tanks with electric element

English. Heating with logs & wood pellets 20-40

VRV The total solution. Integrated Climate Control

SHERPA. Air-water split heat pump. COP > 4 ACS a 60 C

OPERATION GUIDE MODEL CERV-001-PARTA, CERV-001-PARTB CONDITIONING ENERGY RECOVERY VENTILATOR (CERV)

Heat pumps. Heating systems Industrial systems Refrigeration systems

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Optimum efficiency using every bit of energy

SWP. Water heater with SWP heat pump Hot water finally costs less. + Efficiency + Savings + Wellbeing

Discover ebm-papst for buildings. Energy-efficient fans for a controlled room atmosphere.

Dimplex High efficiency air-to-water heat pump for indoor installation. (Low temperature) Order reference

Mechanical ventilation with heat recovery

Lennox Mini-Split Systems Year-Round Comfort and Performance

Create the right atmosphere with renewables

NUOS RANGE HEAT PUMP WATER HEATERS

PE1 Pellet. PE1 Pellet. Pellet boiler - Canada. PE1 Pellet APPROVED FOR EPA 2020 EMISSION LIMITS.

Simply renewable A ++ A +++ ROTEX air-to-water heat pump

Ventilation unit Zehnder ComfoAir 200

THE CARRIER COMFORT LINE

Air to water Heat Pump System

Flexible heating system without limits.

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

Planning guide. (2010/09) en

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

The natural ombination

the expert in heat management.

Heating with wood chips

Starting current with soft starter Fuse protection

Saving energy comes naturally to us.

AIR CONDITIONING HOLIDAY. Elite W A R R A N T Y

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

RETAIL PRICE LIST. season 2017/2018 valid from: April 18, INTELIGENTNE ROZWIĄZANIA

Product Range kw

your tree NEW TREE for you Several facts on trees: Follow our Green Tree heat pumps

Solar water heating system

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

Measurement and modelling of a multifunctional solar plus heatpump system from Nilan. Experiences from one year of test operation.

The ultimate fresh air solution.

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

2 - The compressor increases the pressure of the refrigerant gas which causes it to increase in temperature.

Savings and performance worth celebrating! The DHP-AQ new air source heat pump from Danfoss

Samsung EHS Heat Pump Test

Log fired heating system

Transcription:

OCHSNER hot water heat pumps NATURAL HOT WATER

OCHSNER hot water heat pumps HOT WATER HEATING MORE EFFICIENT THAN EVER The Europa Series heat pumps are the ideal supplement to any heating system for providing all your hot water needs. As well as providing hot water extremely efficiently, they can also provide other features such as cooling and exhaust ventilation of store rooms (eg. pantries). Environmentally friendly hot water heating using air/exhaust air or ground heat as the heat source Combinable with photovoltaic- or solar systems Very quiet operation ehpa-seal of quality Intelligent control technology with the simplest operation and with Touch Display Additional functions such as cooling, drying and ventilation Highly efficient and with long life Page 2

OCHSNER hot water heat pumps offer the following additional advantages Up to 65 C hot water A hot water temperature up to 65 C in heat pump operation means more hot water if required. For an occasionally higher hot water demand, E-rods are factory-fitted in the tanks of the compact units. High-class components for high reliability Double vacuum-enamelled quality hot water storage tanks ensure a long service life of your heat pumps. Only chlorine-free, absolutely ozone-neutral and non-flammable safety refrigerants as well as high-quality compressors are used. The only cost effective alternative to solar thermal hot water heating Using solar heat indirectly day & night, even in bad weather Easy commissioning Quick setup, fast installation Plug in switch on ready! Tiptronic plus control with Touch Display Intelligent control with simple operation of: Models Europa 323 DK, 323 DK-EW, 333 Genius and Mini IWP with SmartGrid function Hot-water regulation with switchable Hygiene - Comfort function Ventilation function with integrated fan-speed regulation and timer program Real time clock (timer program for hot water, hygiene and ventilation modus) Heat pump operation with defrost function for deployment down to -10 C air temperature Solar regulation as standard in Models Europa 323 DK and 323 DK-EW for solar thermal system (to be supplied and configured on site) using the Tiptronic plus Smart Grid (SG) Function, the Europa 323 DK, Europa 323 DK-EW and Europa Mini IWP are already prepared for Smart Metering and therefore well equipped for the electricity network of the future Use your own-generated PV electricity as priority for hot water production, thus easing your budget and the environment by decreasing your CO 2 emissions. Additionally, you can benefit from the expected favourable rates of future power grids!

OCHSNER hot water heat pumps Europa PRODUCT RANGE Europa 323 DK AIR/EXHAUST AIR HEAT PUMP WITH 300 L TANK Europa 323 DK-EW DIRECT EXTRACTION HEAT PUMP WITH 300 L TANK for hot water heating, cooling of pantries and storage rooms, cellar dehumidification and ventilation for hot water heating all-year-round, even at low outdoor temperatures - for passive and low-energy houses Compact unit with 300 l storage tank water temperature up to 65 C in heat pump operation heat pump operation with de-icing function for use down to -10 C air temperature with immersion sleeve for third-party brand thermostat or sensor with register for external heat sources such as furnaces or solar collectors E-rod heating element factory fitted air ducts DN 150 up to 20 m possible 2 factory-fitted sacrificial magnesium anodes legionella switching using heat pump operation optimum heat input Tiptronic plus control with Touch Display Compact unit with 300 l storage tank water temperature up to 60 C in heat pump operation with immersion sleeve for third-party brand thermostat or sensor with register for external heat sources such as furnaces or solar collectors E-rod heating element factory fitted With 75 m copper ground collector for use of ground heat from the garden for up to 1,700 operating hours per year 2 factory-fitted sacrificial magnesium anodes legionella switching using heat pump operation optimum heat input Tiptronic plus control with Touch Display Page 4

*Available from Q4/2017 Europa 333 GENIUS AIR /EXHAUST AIR HEAT PUMP WITH 300 L STORAGE TANK Europa 300 L AIR /EXHAUST AIR HEAT PUMP WITH 300 L STORAGE TANK for hot water heating, cooling of pantries and storage rooms, cellar dehumidification and ventilation for hot water heating, cooling of pantries and storage rooms, cellar dehumidification Compact unit 333 Genius the new flagship in the OCHSNER hot water series heat sources air/ exhaust air water temperature up to 65 C in heat pump operation Smart-Grid ready PV - Own consumption optimising - continuously variable from 0 to 2000 W with Register for external heat sources, such as heating boiler or solar thermal systems impressed current anode legionella switching via heat pump operation most simple commissioning Compact unit 300 L with 300 l storage tank water temperature up to 65 C in heat pump operation ready to run e-heating rod factory fitted as standard air routing DN 150 up to 20m possible 1 pce. Magnesium protective anode factory fitted legionella switching via heat pump operation optimum heat input Tiptronic light control without additional register - thus not suitable for external heat sources, such as heating boiler or solar thermal systems Tiptronic plus S control with Touch Display intelligent control with simple operation: hot water regulation with selectable hygiene-comfort switching ventilation function with integrated fan speed control heat pump operation with defrost function down to -10 C real time clock (timer program for hot water, hygiene and ventilation modus) BUS - communication for building management / Smart Home connection

Europa 250 DK/DKL AIR/EXHAUST AIR HEAT PUMP WITH 250 L TANK Europa Mini IWP/IWPL AIR/EXHAUST AIR HEAT PUMP FOR EXTERNAL TANKS UP TO 500 L Europa Mini EWP DIRECT GROUND EXPANSION HEAT PUMP FOR EXTERNAL TANKS UP TO 500 L for hot water heating, cooling of pantries and storage rooms, cellar dehumidification and ventilation Compact unit Europa 250 DK with 250 l storage tank for households with up to 4 persons water temperature up to 65 C in heat pump operation with immersion sleeve for third-party brand thermostat or sensor with register for external heat sources such as furnaces or solar collectors E-rod heating element factory fitted air ducts DN 150 up to 20 m possible 1 factory-fitted sacrificial magnesium anodes legionella switching using heat pump operation optimum heat input Tiptronic light control Compact unit Europa 250 DKL without additional register - thus not suitable for external heat sources, such as heating boiler or solar thermal systems for hot water heating, cooling of pantries and storage rooms, cellar dehumidification and ventilation, combination with existing pellets, solar or furnace systems Split unit for external tanks up to 500 l water temperature up to 60 C in heat pump operation space-saving design air ducts DN 150 up to 20 m possible internal heat exchanger tank charging via integrated circulation pump legionella switching using heat pump operation also available as package solution with 300l or 500l DHW tank Split appliance IWP Tiptronic plus control with Touch Display Split appliance IWPL Tiptronic light control for hot water heating, also at low outside temperatures, auxiliary heating via buffer tank Energy supply to passive houses, combination with existing pellets, solar or furnace systems Split unit for external tanks up to 500 l water temperature up to 60 C in heat pump operation space-saving design with 75 m copper ground collector for ground heat from the garden for up to 1,700 operating hours per annum internal heat exchanger tank charging via integrated circulation pump legionella switching using heat pump operation Tiptronic light control also available as package solution with 300l or 500l DHW tank Page 6

More than just hot-water heating: The Europa multifunctional appliances can dry, cool and provide corresponding ventilation. EXAMPLE A (Type Europa 250 DK/DKL, 323 DK, 333 Genius, 300L and Mini IWP) installation in heating room hot-water heating from room air added benefit: store room or wine cellar cooling EXAMPLE B (Type Europa 250 DK/DKL, 323 DK, 333 Genius, 300L and Mini IWP) installation in laundry room hot-water heating from room air added benefit: laundry drying in the room, decalcified water for steam irons EXAMPLE C (Type Europa 323 DK, 333 Genius / living space ventilation as exhaust-air system) installation in utility room with heating heat pump heat recovery from exhaust air for hot water heating added benefit: living space ventilation (hygienic single-duct system) Extraction of stale, moist air from damp rooms (bathroom, WC, kitchen) and controlled fresh-air entry using adjustable wall-vents in living area, hallway or staircase. symbolic picture HOT WATER HEAT PUMPS MULTIFUNCTION APPLIANCES/EXHAUST AIR HEAT PUMPS SERIES MODEL 333 Genius EUROPA 323 DK 323 DK-EW 300 L 250 DK 250 DKL Mini IWP Mini IWPL Mini EWP Dimensions (Dia.xH) [mm] 650 x 1850 650 x 1850 650 x 1850 650 x 1850 650 x 1610 650 x 1610 650 x 426 650 x 426 650 x 426 Weight [kg] 165 165 165 165 145 141 45 45 43 COP according to 16147 3,82 3,15 3,5** 3,15 2,71 2,71 3,16 2,94 4,1** 4** Heat pump capacity at E4/W15-55 E4/W15-55 E4/W35 Sound pressure level at distance of 1 m [db(a)] 49 49 35 49 49 49 49 49 49 Nominal voltage [V] 230 230 230 230 230 230 230 230 230 Operating temperature of air input min/max* [ C] -10/+40-10/+40 - +6/+40 +6/+40 +6/+40-10/+40 +6/+40 - max. water temperature [ C] 65 65 60 65 65 65 60 60 60 Energy efficiency class A + A + A A + A + A + A + A A *Temperature of installation area minimum + 10 to + 15 C (depending on mode of operation) **COP according to EN 255-3 The performance data refer to the heat pump data measured under standard conditions (heating capacity, COP), taking the specified tolerances into consideration. The energy efficiency of the system and thus the running costs are the responsibility of the system installer. The heat pump heating systems are to be installed according to OCHSNER guidelines. No guarantee of the heat pump function can be given for systems that have not been built to these guidelines. OCHSNER therefore recommends that trained OCHSNER-System partners install the heat pump. Even if the system has been installed according to the OCHSNER guidelines, the efficiency values on site can still deviate from factory specifications, because the latter are based on standard conditions. Furthermore, user behaviour also plays a decisive role.

OCHSNER Wärmepumpen GmbH Austria (Commercial register) Krackowizerstraße 4 A-4020 Linz kontakt@ochsner.at Head office/works Ochsner-Straße 1 A-3350 Haag Tel: +43 (0)5 042458 Customer-Hotline: +43 (0)820 201000 kontakt@ochsner.at OCHSNER Wärmepumpen GmbH Germany D-60314 Frankfurt a. M. Riederhofstraße 27 Customer-Hotline: +49 (0)1805 624763 kontakt@ochsner.de OCHSNER Switzerland CH-8001 Zürich Uraniastrasse 18 Tel: +41 583204 100 kontakt@ochsner.com Phone: 01463713131 www.ochsner.com OCHSNER East PL 31-302 Kraków ul. Pod Fortem Nr. 19 Tel: +48 (0)12 4214527 kontakt@ochsner.pl identity.co.at Subject to technical changes, misprints and errors. W774e P 03/2017