Connection of CES-AP to safety relay PNOZ s4.1 Content

Similar documents
Connection of CET4-AR to safety relay PNOZ s5

Connection of CET4-AR to safety relay PNOZ X3.10P

Connection of CET4-AP to Siemens ET 200S

Examples for Use of the MGB Inputs and Outputs

Simply safe. Transponder-coded safety switch CET with guard locking

Simply safe. Transponder-coded safety switch CET with guard locking

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

More than safety. Operating Instructions Safety Switch CET.-AS-...-CB-... (Multicode)

SPECIALISTS IN SAFETY ENGINEERING FOR THE PACKAGING INDUSTRY.

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018

SAFETY RELAY APPLICATION

Safety Function: Single-beam Area Access Control (AAC)

Non-contact, coded safety switches PSEN

The plant meets the requirements of the current FSS 5 Checklist for Vessel Process Plants

Standard package Safexpert Standard Standard package Safexpert Standard PLUS Small Standard package Safexpert Standard Plus

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

Highlights Solutions for you. DOLD - Our experience. Your safety.

ATEX Safety Switches. More than safety.

Safexpert. Standards. Trainings & Seminars. Price list EUR. January 2019

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Original operating instructions Safety switch with guard locking AC901S AC902S

Pilz for a safe crane system

ISIS SAFETY SYSTEM Installation guide

Magnetically Coded Non-contact Switch (MC2)

Safety. Detection. Control. SAFETY INTERFACES. Safety Interfaces and Relays. Product catalogue. Issue 1

CHECKFIRE 210 Detection and Actuation System

SensaGuard TM Integrated Latch Installation Instructions

Australian Standard. Safeguarding of machinery

Dohse Aquaristik GmbH & Co. KG

Operating instructions Mini Jet Ionisator. Air Line V01

Machine Guarding and Safety

LAE10 LFE10. Use. Series 02

Original instructions Sense7-series Non-contact coded safety switch

Operating Guide Safe Torque Off

Operating instructions

9 Standards, Regulations and Authorities

Basics of Safety Applications

Basics of Safety Applications

One giant leap for safety: AZM400.

ISO INTERNATIONAL STANDARD. Safety of machinery Laser processing machines Part 1: General safety requirements

/ sicam SICAM Safety Full functionality for safety-critical applications Answers for infrastructure and cities.

Important Safety Notice

PROTECT SRB 200EXi-1A

Operating Guide Safe Torque Off

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

SAFEMASTER STS. The key to more safety. Our experience. Your safety.

Remote alarm unit Art. Nr.:

Flame Safeguards LFE10. Building Technologies HVAC Products

Edition 8 From serial no Publ. no OM 5030NHD; Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL)

Where Process Safety meets Machine Safety

MACHINERY SAFEBOOK 5. Safety related control systems for machinery. Principles, standards and implementation. (Revision 5 of the Safebook series)

Multifunctional Gate Box MGB. More than safety.

FUNCTIONAL SAFETY OF ELECTRICAL INSTALLATIONS IN INDUSTRIAL PLANTS BY OTTO WALCH

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Cooling Unit for Producing Chilled Water. Envicooler. Operation and Maintenance Instructions. Air handling with the focus on LCC

Functional Safety of Machinery Presented by Greg Richards Manufacturing in America 02/22-23/2017

The Machinery Directive 2006/42/EC

Pilz Safety Lockout System (PSLS)

First of all, what is a safety-related

DIRECTIVE NO: D-B

Operating instructions

Technical Specification for Remote Controlled Temporary Traffic Management Signs for use on the Highways Agency Strategic Road Network

Dohse Aquaristik GmbH & Co. KG

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

ENGLISH USER S MANUAL PRE SOAKER 3600


Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Edition 8, From serial no Publ. no OM 5030, Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL)

CE Marking and Technical Standardisation

100 Series Gas Ventilation Interlock System

Flame Safeguards LFE10. Building Technologies HVAC Products


SAFETY STANDARDS & SOLUTIONS MATERIAL HANDLING & INTRALOGISTICS

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System)

Installation Instructions. devireg 700/ /752/753/754

Control Panel Basics Volume 1

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

Sliding Gates White Paper 1 Sliding Gate Safety Third Edition

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

European Regulations of Medical Devices and In-vitro Diagnostic Medical Devices. The Notified Body Point of View

Installer: (Name, address, telephone)

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

CRU-S Series Stainless Steel Condensate Recovery Unit

Translation Supplementary requirements for the testing and certification of Safety relays

Installer: (Name, address, telephone)

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

ISO INTERNATIONAL STANDARD. Industrial fans Mechanical safety of fans Guarding

ISO Safety of machinery Laser processing machines Part 1: General safety requirements

TECHNICAL SPECIFICATION

ESPE Electro-Sensitive Protective Equipment

The Next Generation Machine Protection System

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

Safety Service MACHINE. Risk evaluation Safety level evaluation. News about directives. Periodical device inspection. Control of electric parts

Product overview. Alarm indicator, operator and display panels

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

Transcription:

Connection of CES-AP to safety relay PNOZ s4.1 Content Interlocking device according to EN 1088... 2 Components/modules used... 2 EUCHNER... 2 Other... 2 Functional description... 3 General... 3 Connections... 3 Safety assessment... 3 Principle circuit diagram... 4 Setting of the operating mode selector switch mode... 5 Automatic, manual start without short circuit detection... 5 Monitored start rising edge without short circuit detection... 5 Monitored start falling edge without short circuit detection... 5 Setting of the Reset for PNOZ s4.1... 6 Manual Reset... 6 Automatic Reset... 6 Important note please observe carefully!... 7 AP000178-01_07/13 Page 1 of 7

Interlocking device according to EN 1088 Safety function Interlocking device according to EN 1088 Reliability figures according to EN ISO 13849 Category 4, PL e Components/modules used EUCHNER Description Safety switches with transponder technology Order no./ item designation 116502 / CES-I-AP-U-C04-USB-11650 117324 / CES-I-AP-M-C04-USB-117324 Tip: More information and downloads about the above mentioned EUCHNER products can be found at www.euchner.de. Simply enter the order number into the search field. Other Description EMERGENCY STOP Safety relay Items PNOZ s4.1 / 750 124 (V1.0) PNOZ s4.1 C / 751 124 (V1.0) AP000178-01_07/13 Page 2 of 7

Functional description General The CES-AP is part of an interlocking device in accordance with EN 1088. The two safe outputs of the last CES-AP are connected to a PNOZ s4.1 safety relay. Connections Designation Function Use in this example FO1A, FO1B OD Safety outputs. HIGH when the safeguarding device is closed and the actuator is in operating distance. Monitoring output. HIGH when outputs FOIA and FOIB are switched on (safety guard closed). Switch-off of at least one of the outputs leads to a direct switch-off of the safety contacts (13 14, 23 24, ) of the safety relay PNOZ s4.1. Important: The actual shutdown of the energy which is causing a hazard in a machine is not shown in the example and must be supplemented. Function is not used. Safety assessment The CES-AP features complete monitoring for faults in the safety-relevant parts and in the connected cables (clock pulses at outputs FO1A and FO1B). The safety relay PNOZ s4.1 achieve up to PL e according to the manufacturer s information (see the device s operating instructions for this purpose). The wiring corresponds to the circuit light barrier or safety switch with detection of shorts across contacts via ESPE in the operating instructions of the PNOZ s4.1. Therefore, PL e in accordance with EN ISO 13849-1 can be achieved for position monitoring of a safety guard and for interlocking (preventing the operation of a machine element under certain conditions). Important: Switch-off of the energy and any necessary monitoring energy switch-off (feedback loop) of the hazard are not part of this document and must be added in accordance with the risk assessment for the machine. In this example, the safety evaluation unit without feedback loop and without start button is used. Please refer to the operating instructions of the safety evaluation unit for more information. AP000178-01_07/13 Page 3 of 7

Principle circuit diagram In the example Automatic Reset of the PNOZ s4.1 is used Figure 1 AP000178-01_07/13 Page 4 of 7

Setting of the operating mode selector switch mode Only with the following settings does the safety relay PNOZ s4.1 operate correctly with a CES-AP. Automatic, manual start without short circuit detection Operating mode selector Automatic, manual start switch mode Without short circuit detection ATTENTION: For an automatic start push-button S2 has to be replaced by a bridge. Monitored start rising edge without short circuit detection Operating mode selector Monitored start, rising edge switch mode Without short circuit detection Monitored start falling edge without short circuit detection Operating mode selector Monitored start falling edge switch mode Without short circuit detection AP000178-01_07/13 Page 5 of 7

Setting of the Reset for PNOZ s4.1 Only with the following settings does the safety relay PNOZ s4.1 operate correctly with a CES-AP. Manual Reset Automatic Reset AP000178-01_07/13 Page 6 of 7

Important note please observe carefully! This document is intended for a design engineer who possesses the requisite knowledge in safety engineering and knows the applicable standards, e.g. through training for qualification as a safety engineer. Only with the appropriate qualification is it possible to integrate the introduced example into a complete safety chain. The example represents only a part of a complete safety chain and does not fulfill any safety function on its own. In order to fulfill a safety function, the energy switch-off function for the hazard location and the software within the safety evaluation must also be considered, for example. The introduced applications are only examples for solving certain safety tasks for protecting safety guards. The examples cannot be comprehensive due to the application-dependent and individual protection goals within a machine/installation. If questions pertaining to this example remain open, please contact us directly. In accordance with Machinery Directive 2006/42/EC, the design engineer of a machine or installation is obligated to perform a risk assessment and take measures to reduce the risk. When doing this, the engineer must comply with the applicable national and international standards. Standards generally represent the current state of the art. Therefore, the design engineer should continuously inform himself about changes in the standards and adapt his considerations to them. Relevant standards include EN ISO 13849 and EN 62061. This application must be regarded only as assistance for the considerations about safety measures. The design engineer of a machine/installation is obligated to assess the safety technology himself. The examples must not be used for assessment, because only a small excerpt of a complete safety function was considered in terms of safety engineering here. In order to be able to use the safety switch applications correctly on safety guards, it is indispensable to observe the standards EN ISO 13849-1, EN 1088 and all relevant C-standards for the respective machine type. Under no circumstances does this document replace the engineer s own risk assessment, and it cannot serve as the basis for a fault assessment. Particularly in case of a fault exclusion, it must be noted that this can be performed only by the design engineer of a machine or installation and requires a reason. A general fault exclusion is not possible. More information about fault exclusion can be found in EN ISO 13849-2. Changes at products or within assemblies from third-party suppliers used in this example can lead to the function no longer being ensured or the safety assessment having to be adapted. In any event, the information in the operating instructions on the part of EUCHNER, as well as on the part of third-party suppliers, must be taken as the basis before this application is integrated into an overall safety function. If contradictions should arise between the operating instructions and this document, please contact us directly. Use of brand and company names All mentioned brand and company names are property of the respective manufacturers. The use is only for clear identification of compatible peripheral devices and environment of operation in combination with our products. EUCHNER GmbH + Co. KG Kohlhammerstraße 16 70771 Leinfelden-Echterdingen Telefon: +49 711 75 97-0 Telefax: +49 711 75 97-303 info@euchner.de www.euchner.de AP000178-01_07/13 Page 7 of 7