Review Paper Effect of Parameters in Once-Through Boiler for Controlling Reheat Steam Temperature in Supercritical Power Plants

Similar documents
Solution of I Mid Term Steam Engineering 6ME5A

Boiler Basics. Design and operation

Improving Boiler Stability Through Advanced Regulatory Control

BHEL Steam Generators Material Selection Overview by Veerendar Aluvala DM/BHEL/Trichy

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

BENSON Boiler Technology

BENSON Boilers Experience in Nearly 1000 Plants and Innovative Design Promise Continuing Success Manfred Klein, Rudolf Kral, Eberhard Wittchow

ecodry Figure 1 - Process Diagram ecodry B General Process Description

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Boiler Draft Equipment

TEPZZ 87_ 6A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION

Chapter 10 VAPOR AND COMBINED POWER CYCLES

PESIT-Bangalore South Campus

Development of Boiler Design

Study and Design Considerations of HRSG Evaporators in Fast Start Combined Cycle Plants. Govind Rengarajan, P.E.CEM, Dan Taylor

CONTROLLING BOILER SWELL AND SHRINK

MECHANICAL SCIENCE Module 2 Heat Exchangers

CHAPTER 3 BASIC STEAM CYCLE

Analysis to speed up of the start-up of steam boiler OP-380

Attention is drawn to the following places, which may be of interest for search:

INCREASING BOILER EFFICIENCY BY USING DIFFERENT MEASUREMENTS AND TYPES OF FIRETUBE PLATES AND DIFFERENT NOZZLES

MODULATING CONTROL OF LOW NO X BURNERS

OPTIMISATION OF SOOT BLOWER OPERATION IN BOILER TO IMPROVE EFFICIENCNY

PERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

POWER Selecting Shell Side Design Temperature for Feedwater Heaters

AUTOMATION OF BOILERS USING LABVIEW

WHAT IS A BOILER? BOILER IS AN EQUIPMENT WHICH PRODUCES STEAM AT THE REQUIRED PRESSURE AND TEMPERATURE. BOILER DESIGN, MANUFACTURE & INSTALLATION ARE

Efficient Steam System Design

SCHNEIDER-KESSEL BERLIN

Chapter 2.3: Steam System

NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES

PACKAGED COMMERCIAL WATERTUBE BOILERS


B.Tech. First Semester Examination Basics of Mechanical Engineering (ME-101F)

WET POSITION BOOSTER FANS FOR REDUCED POWER CONSUMPTION AND OPTIMIZED ENVIRONMENTAL PERFORMANCE OF POWER STATIONS WITH FGD AND WET STACK

A Newsletter published by ESI. The Steam and Power SPECIAL FORCES

Yarway Narvik Steam Desuperheater Series 4300 TempLow

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Efficiency and Design Improvements in Multiple Hearth & Fluid Bed Incinerators

What to Expect from Your EtaPRO Investment

Parametric Analysis of Surface Condenser for Thermal Power Plant

US A United States Patent (19) 11 Patent Number: 6,092,490 Bairley et al. (45) Date of Patent: Jul. 25, 2000

- Essay Control Functions and Benefits

THERMAL ENGINEERING & GAS DYNAMICS ME-6002

HEAT EXCHANGERS. Heat exchangers are broadly classified based on the following considerations.

Drying principles and general considerations

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

THE GATE COACH All Rights Reserved 28, Jia Sarai N.Delhi-16, ,-9998

Week 13 Chapter 10 Vapor & Combined Power Cycles

Figure 1: Overview of Rovinari Power Station FGD project planned situation.

Amec Foster Wheeler- Fired Heater Division

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

Efficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

State Grid Zhejiang Electric Power Corporation Electric Power Research Institute, Hangzhou, , China

Homework #4 (group) Tuesday, 27 by 4:00 pm 5290 exercises (individual) Tuesday, 27 by 4:00 pm extra credit (individual) Tuesday, 27 by 4:00 pm

Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina

ENERGY OPTIMIZATION IN THE MAA GAS PROCESSING FACILITIES

A CASE STUDY ON BOILER TUBE FAILURE AT JPL

The Ultimate in Direct Contact Water Heating. by Thermal Engineering of Arizona, Inc. An Inc. 500 Company

Steam Fundamentals. (in heating & processing applications)

HOW TO BOOST THE PERFORMANCE OF FIRED HEATERS

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

Products & Services. DISTRIBUTOR & FOREHEARTH SYSTEMS

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

High Performance Diesel Fueled Cabin Heater. Abstract

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

Influence of Feed Water Heaters on the Performance of Coal Fired Power Plants

Document Code: 1 (13) Issuing date: Status:

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

"A Case Study of Three Drum Parameter Control in Boiler Using Discrete PID Controller Based on Simulation"

REVIEW ON CONDENSER AIR LEAK TEST

Lignite fired power station in Romania fits FGD with Wet Booster Fans and Pennguard lined Concrete Chimneys for maximum Efficiency

Heat Reclaim. Benefits,Methods, & Troubleshooting By Dave Demma, Manager Supermarket Sales, Sporlan Division - Parker Hannifin Corporation

Boiler. Fire tube Boiler:

(Refer Slide Time: 00:00:40 min)

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units.

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE

MASS TRANSFER EQUIPMENT DESIGN CONSIDERATIONS FOR CRYOGENIC ABSORBERS, DEMETHANIZERS AND DEETHANIZERS

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

"HC" AIRFLO. In-duct firing line burner

AIM OF THE EXPERIMENT:- Study of boilers (fire tube, water tube) APPARATUS REQUIRED: - SL.NO NAME OF THE APPARATUS SPECIFICATION QUANTITY 01 Fire tube

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

Boiler drum level controller using Microcontroller

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Steam and Gas Power Systems Prof. Ravi Kumar Department of Mechanical and Industrial Engineering Indian Institute of Technology - Roorkee

Heat pump supplemental heating system for motor vehicles

EXCELSIOR SINHGAD COLLEGE OF ENGINEERING, PUNE PAPER PRESENTATION

WATER TUBE SOLID FUEL SERIES YOSHIMINE CO., LTD

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

Brown Hills College of Engineering & Technology

Transcription:

Research Journal of Engineering Sciences ISSN 2278 9472 Review Paper Effect of Parameters in Once-Through Boiler for Controlling Reheat Steam Temperature in Supercritical Power Plants Abstract Ravindra Kumar P. 1, Ramchandra Raju V. 2 and Ravi Kumar N. 3 1 LakiReddy Bali Reddy Engineering College (Autonomous), Mylavaram, Vijayawada, Krishna (DT), AP, INDIA 2 JNTU College of Engineering, Vizianagaram (DT) AP, INDIA 3 MVGR College of Engineering, Vizianagaram (DT) AP, INDIA Available online at: www.isca.in Received 5 th November 2012, revised 15 th November 2012, accepted 25 th November 2012 In once through boilers, superheated steam is generated at a pressure and temperature above the critical point of 221.2 bar and 375 0 C. For controlling Reheat steam temperature in once through boilers, many methods are being adopted namely Burner angle, Gas Recirculation, divided back pass dampers, excess air and steam bypass as primary control and feed water attemperation is considered as an emergency control. When the boiler is operated in sliding pressure mode the cold reheat steam temperature is higher compared to constant pressure operation. The adjustment required for maintaining constant Reheat outlet temperature is larger in constant pressure operation mode. In general spray is not used for RH steam temperature control for boilers designed for constant pressure operation since the spray quantity required will be large and it will effect on plant heat rate. Utility boilers are operated under sliding pressure mode and hence Reheat steam temperature control by spray is a common practice especially for once-through boilers. This paper deals with the benefits and losses of using spray for Reheat steam temperature control in lieu of other control mechanisms. If the plant incorporates reheat and several stages of feed heating, there is about a 2% gain in overall thermal efficiency compared with the corresponding subcritical cycle. Keywords: Once-through boilers (OTB), supercritical cycle (SC), reheat (RH), and superheat (SH), gas recirculation (GR), natural circulation (NC). Introduction In utility boilers, it is important to achieve best possible heat rate to reduce the fuel cost and hence the operators try to maintain superheat and reheat steam temperatures at a rated value to the extent possible 1. In a once through boiler there is no distinction between liquid and vapor phases and there is a continual increase in fluid temperature 2 In once through boilers, SH steam temperature is maintained by means of coordinated feed water flow and spray attemperation. There are many methods to control RH steam temperature: like Tilting of burner, gas recirculation (GR), divided back pass dampers, excess air and steam bypass. Spray, though considered as an emergency control, is not preferred as a means of RH steam temperature control in constant pressure operation as it affects plant heat rate. However, in case of once through boilers which are generally operated in sliding pressure mode, quantum of RH spray is expected to be lower. In this case RH spray attemperation is preferred as it will result in simpler design and operation of the boiler and also less maintenance as systems like Tilt of burner, GR fans; divided back pass dampers are eliminated 3. The Effect of optimum number of Feed water heaters on the overall plant efficiency improvement is explained by 4, 5. Once-through supercritical boilers have been installed in the U.S. since the 1950s. Some of the earlier constructed units have experienced various problems related to operation and reliability 6. The original supercritical units installed were designed for constant pressure operation, i.e. the boiler operates at full load pressure from start-up and across the entire load range. For start-up, constant pressure operation boilers require a start-up bypass system, which is complex in configuration and operation compared with the new sliding pressure Benson boilers. As a result, the start-up time for constant pressure boilers is longer and the plant minimum load must be kept higher than for the sliding pressure units 7. Nearly 200 supercritical steam generators are operating world-wide today, with pressures up to 310 to 320 bar. In Supercritical Power Plants the Feed Water Temperatures can be raised up to 200 0 C 8. More advances in materials and designs introduced in the late 90's have raised steam temperatures as high as 620 0 C achieving efficiencies of 44% 9. At steam temperatures up to 650 0 C, efficiencies of 50% are being predicted 10, 11. The nature of supercritical steam generation rules out the use of a boiler drum to separate steam from water Drum less "once through" steam generators are universally used for Supercritical operation. The term "steam generator" will be used instead of "boiler" for oncethrough steam production, because boiling as such does not really take place. Turbines for subcritical systems are usually designed for steam pressures of 180bar. A drum operating pressure of 180 to 200bar is required to allow for pressure drops International Science Congress Association 27

in the superheater and main steam line. The densities of steam and water rapidly approaching each other above this pressure level represents an approximate limit for drum-type boilers incorporating steam separation and recirculation. Thermodynamic analysis and its improvement in heat and power for power plants is explained 19. Constant and Sliding Pressure Operation The output of a condensation power station is set by means of m& the live steam mass flow LS P The mechanical power, m of the P turbine shaft depends on the live steam pressure LS, the crosssection of the opening A, or the lifting of the turbine intake T valves, and the live steam temperature, LS according to the following relation: & P LS Pm mls A T LS (1) The live steam temperature should remain constant throughout the whole load control range, so that a high efficiency rate is also achieved during part load and to avoid stress on the turbine caused by temperature changes. The turbine output and the live steam mass flow to the turbine are set during steady-state conditions, either when the live steam pressure is at a constant cross-section of the turbine intake valves (sliding or variable pressure) or when the intake cross-section is at a constant steam pressure (constant pressure). Sliding pressure operation with a low-load recirculation system enables the Benson type boiler to start-up with similar operation characteristics and a start-up pressure profile as for an NC drum type boiler. While the start-up valves in a constant pressure supercritical boiler have to resist a large pressure difference during the bypass operation, the start-up valves in a sliding pressure boiler are only used during the swelling period, which occurs immediately after boiler light-off. The differential pressure during such swelling is less than 6.8 bar, and therefore the duty of the start-up valves is much less in a sliding pressure boiler than the constant pressure boiler. For the Benson boiler, the transition from recirculation mode to once-through mode, or vice-versa, is performed automatically with the operation of the low-load recirculation system and turbine bypass system. By adopting the sliding pressure operation with lower boiler pressures at partial loads, the plant heat rate can be improved at partial loads due to i. improvement of high pressure (HP) turbine efficiency, ii. reduced auxiliary power consumption by boiler feed pumps, and iii. higher steam temperature at the HP turbine outlet. In addition to the plant efficiency advantages, there are other benefits such as reduction in start-up time, increase in ramp rate and reduced erosion of bypass valves. Sliding pressure operation can be utilized in certain drum type boilers as well as once-through steam generators (with some qualifications). The main advantage is higher part load efficiencies. In a conventional drum type boiler-turbine combination, the boiler pressure remains essentially constant throughout the operating range, with load control accomplished by the turbine throttle valves. Throttling steam flow is not a reversible process and therefore introduces inefficiencies to the cycle. With sliding pressure operation with drum type boilers, the turbine operates essentially with throttle valves wide open throughout most of the load range, but admits steam to only a portion of the throttle valves (partial arc admission) rather than all of the valves (full arc admission), and the turbine power is controlled by varying the boiler pressure. Sliding pressure operation has the further advantage of maintaining full superheat temperature over a wider load range than conventional throttling control. This reduces the cyclic thermal stresses experienced during cycling operation. Cycling operation may be defined as rapid rates of load increase and a significantly larger number of starts up and shut down cycles compared to a base load unit. In once through steam generators, load is a function of the steam flow, which in turn is controlled by the feed water pumps. If the pressure throughout the steam generating tubes is allowed to drop below the critical pressure, two-phase flow and steamwater separation will result. This will result in some of the secondary superheater tubes having variations in the steamwater mix. Because of the differences in densities between steam and water, flow will be restricted in the tubes having a greater steam concentration, and uneven heat transfer could cause tube failures. In order to take advantage of the benefits of variable pressure operation during load turndown, pressure control division valves are installed between the primary and secondary superheaters. These valves keep the steam generator tubes above the critical pressure, while permitting the turbine to operate under its optimum pressure for a given load. With partial arc steam admission, the full steam throttle pressure can be maintained down to about 60% load. Because of the requirement to maintain steam generator pressure, the advantage of reducing feed pump pressure at reduced loads cannot be realized with supercritical cycles. The steam temperature is controlled by the firing rate, and is augmented in some units by injecting superheating water between the superheat stages. A once through steam generator requires a more precise balance of Inputs and outputs than drum type boilers because of the lack of the flywheel effect of a boiler drum. In sliding-pressure operation, the turbine output and the steam flow are adjusted by the pressure at the outlet of the boiler. In natural sliding-pressure operation, the live steam valves of the turbine are completely opened, and the cross-section of the turbine intake is constant throughout the whole load range. Advantages of sliding-pressure control are a load-independent temperature distribution in the turbine, a lower pressure stress on the steam generator and a lower power demand of the boiler feed water pump in part-load operation. Disadvantages are the changes of the boiling temperature in the evaporator, due to the pressure changes. The advantage of the decreasing power International Science Congress Association 28

requirement for boiler feed pumping is stronger when the live steam pressure becomes higher. The general outcome in applying natural sliding pressure is a heat rate (including that of the boiler feed pumping power) which is slightly better than with nozzle-governed constant-pressure operation; with modified sliding pressure the heat rate is higher. (a) (b) (c) Figure-2 a) Natural Circulation 1 b) Once Through and residual water separation 1 c) Once through Benson Boiler 1 Figure-1 Graphical Representation of OTB pressures at different Boiler loads 18 Supercritical Steam Generator Design Configurations The major differences between the various once-through steam generator designs on the market are the configuration of the furnace enclosure circuits and the systems used to circulate water at start up and low loads. In both boiler systems, greater output changes are always initiated by increasing the firing rate. Drum and once-through boilers differ in controlling the feed water. In drum boilers, the feed water is designed to be controlled by the drum water level. The feed water control is coupled with the fuel control via the evaporator and the circulation system. Changes in the feed water flow do not immediately influence the flow through the superheater. When the firing rate is increased, delayed steam generation in the circulation system, due to the large storage capacity of the evaporator, may result in insufficient superheater cooling. With rapid load changes, the spray attemperators often do not suffice to control the live steam temperatures, so this circumstance places another limit on the load change rate in drum boilers. Once-through boilers are capable of coping with load change rates of 5-8% per minute, which is higher than the rates of 2-3% per minute that drum boilers can deal. The three leading designs are: i. Vertical Tube multipass furnace, upon which early Supercritical designs were based. These proved suitable for the base load operation, but were not as well suited for cycling because of the thermal stresses involved. ii. The spiral tube Benson furnace configuration, in combination with a boiler recirculation pump was developed to minimize thermal shock during transients. iii. Spiral tube Sulzer furnaces are very similar to the Benson furnaces; both use Seperator vessels for start up. Impact of HP spray water Flow on Once-Through Steam Generators by Sliding-Pressure or Constant-Pressure operation: Circulation systems are almost exclusively operated with constant-pressure control, while once-through systems mostly use sliding pressure, though in some cases constant pressure as well. For steam generators operated with constant pressure only in the evaporator, sliding-pressure operation does have the well-known operating advantage, though not the economic advantage, of the disproportionately decreasing power consumption of the boiler feed pump in part-load operation. Figure-3 Dependence of the HP spray water flow on the unit output and on the fouling state of the furnace 1 International Science Congress Association 29

Need for steam temperature control Superheat and reheat steam temperatures should not be allowed to increase beyond the rated value as it will result in metallurgical problems in superheater and reheater tubes and also turbine components. On the other hand, steam temperature lower than rated value will result in higher cycle heat rate. Typically a temperature reduction of 10 0 C in large capacity power plant will result in about 0.3 % increase in plant heat rate. Hence it is essential to maintain the superheat and reheat temperatures within a narrow range around the rated values. In a coal fired boiler, super heat and reheat pick up are influenced by many variables like coal quality, dirtiness of the furnace, fouling of heat transfer sections, etc,. When the furnace is cleaner compared to the design condition, the furnace absorption is more resulting in lower furnace outlet temperature and hence lower SH and RH temperatures. On the other hand, when slagging / fouling occurs due to deterioration in coal quality, furnace absorption will be lower resulting in higher furnace outlet temperature and hence higher SH and RH outlet temperatures. Normally superheat steam temperature is maintained over the load range by means of coordinated feed water flow and spray attemperation. Various methods are employed to maintain the reheat steam temperature at rated value over the control load range. The after effect of reheat temperature control on superheat temperature increase or decrease is regulated by feed water attemperation 12,13. Relative Heat Rate Improvement (%) 10.00 8.00 6.00 4.00 2.00 0.00 Heat Rate Improvement for Single Reheat Cycle 25 0 C =1.25% Improvement in Heat Rate 180 240 300 360 Subcritical cycle Supercritical Cycle Advanced Supercritical Cycle Superheater Outlet Steam Pressure (bar) 540/540 C 565/565 C 580/600 C 600/600 C 600/620 C Ultra Supercritical Cycle Figure-4 Effect of Relative Heat Rate Improvements for different superheater outlet pressure for Boiler Relative change in efficiency (%) 12 10 8 6 4 2 0 550 600 650 700 750 Reheat Temperature (C) relative change in efficiency at 200 bar relative change in efficiency at 250 bar relative change in efficiency at 300 bar relative change in efficiency at 350 bar Figure-5 Effect of Relative Change in Efficiency for Reheat Temperature at different Pressures International Science Congress Association 30

Burner angle Tilting burners are provided in corner or tangential fired boilers. The burners can be tilted up or down in unison in all the four corners to move the fire ball inside the furnace either upward or downward to change the furnace absorption. When RH temperature is lower than the rated value, burners are tilted up to reduce the furnace absorption and increase the furnace outlet temperature. As more heat is now available for RH pick up, RH temperature can be maintained. When RH temperature is more than the rated value, the burners are tilted down shown in figure 6. heat at furnace outlet are changed. When RH outlet temperature is lower than rated value, GR quantity is increased to increase the heat available for RH pick up. In this case power consumed by the GR fan is additional loss and will increase the net plant heat rate. Figure-7 Divided back pass damper control 16 Figure- 6 Burner angle 16 Divided back pass dampers The divided back pass arrangement is used in wall fired boilers with fixed burners. In wall fired boilers, the convective back pass is divided into two gas passes. On one side, Low Temperature Reheat (LTRH) section is located and on the other side Low Temperature Superheat (LTSH) section is located. These two sections are divided by steam cooled wall or a baffle plate. A common economiser heat transfer section is located across both the LTRH and LTSH sections outlet. The gas mass flow through LTRH side can be increased or decreased (gas biasing) by the multi louver dampers positioned at the outlet of each pass (generally at the outlet of economizer section in lower gas temperature region). Figure-7 for a typical arrangement of dived back pass with control damper. Gas Recirculation Flue gas at economizer outlet or ID fan outlet is drawn and reintroduced into the furnace by a Gas Recirculation (GR) fan. Tight shut off dampers are positioned both upstream and downstream of the fan. Refer Figure 8 for a typical arrangement of gas recirculation. As the quantity of re-circulated gas is changed, the quantity of heat absorbed in the furnace and the Figure-8 Reheat Steam Temperature control by Gas Recirculation 16 Excess air Excess air by itself is not used as a means of RH steam temperature control as an increase in excess air will increase the stack loss and reduces the boiler efficiency. Typically 0.3 to 0.4 % of boiler efficiency will be lost for every 10 % increase in excess air. In some cases especially when the control load is very low, in addition to burner tilt angle or gas biasing, excess air is also to be increased to achieve the Reheat steam temperature. International Science Congress Association 31

Maintaining Constant Reheater Temperatures As in the case of superheating in high-pressure zones, heating surfaces with convection and radiation characteristics should be utilised in order to keep constant reheater steam temperatures. Reheating does not involve the balancing influence on the live steam temperature by migrating vaporisation and superheating zones in the furnace wall of a once-through steam generator. The operating regime of a steam generator - constant or sliding pressure - can have an influence, however, on the necessary temperature rise. In constant pressure operation, the reheater must be supplied with relatively more heat because the reheater inlet steam temperature drops as the output decreases 14. But in sliding-pressure operation, the reheater inlet temperature is nearly independent of the output. A relatively simple method to control and limit the reheater outlet temperature is to spray feed water between two subsequent reheat surfaces at a pressure similar to the exit steam pressure of the high-pressure turbine 14. In this case, the reheater is designed to be larger for full load and its steam exit temperature is limited to the allowable temperature by spray water admixing. When output diminishes, the necessary spray water flow decreases as well. Reheater spraying for temperature control, however, has the consequence of a loss in efficiency, because the high-pressure zone of the steam generator is bypassed, and only steam at the reheater pressure is produced and exploited. The heating of the spray water by mixing at a low reheater pressure results in a lower temperature of heat addition. Table-1 Main Specifications of the Once Through Boiler 17 Item Specifications Generating Capacity (Gross) Boiler Type Main Steam Pressure Main Steam Temperature Reheat Steam Temperature Economiser Inlet Feed Water Temperature Combustion System Draught System Main Steam Temperature Control System Reheat Steam Temperature Control system 1000 MW Babcock-Hitachi Supercritical Sliding Pressure Operation Benson Boiler 245 bar 605 0 C 605 0 C 287 0 C Pulverized Coal Fired Balanced Draught Water-Fuel Ratio Control and Staged Spray Attemperation Parallel Gas Dampering and Spray Attemperation Other methods of temperature control avoid the disadvantageous effect of reheater spraying on the steam generator efficiency 15, for instance by transferring heat between the live steam and the reheater steam system or by shifting the heat flux through flue gas recirculation or tilting burner, to set constant reheater steam outlet temperatures. In order to control the heat transfer between the high-pressure superheater and the reheat surfaces, the reheat surfaces are designed to be either larger or smaller than without this control. Designed larger, they transfer heat to the live steam system in the upper output range. Designed smaller, they take heat from the high-pressure superheaters in lower output range. Excess heat of the reheater can also be used to preheat the feed water. This kind of temperature control only involves pressure losses. Conclusion Once through Boiler with Supercritical Steam parameters (240bar, 600 0 C) improve the plant cycle efficiency by 40% where as with Constant pressure boilers give only 36%. Heat rate improvement of about 1.25% compared with constant pressure boiler gives 0.75% which results in reduced coal consumption. Reduced gaseous emissions and pollutants are possible with once through steam generators compared with constant pressure Natural Circulation boilers. Slight marginal effect on heat rate improvement, RH steam temperature control by spray attemperation in once through boilers is good for the plants. References 1. Spliethoff H., Power Generations from Solid Fuels, 125-200 Springer (2010) 2. Stephen J. Goidich, Richard J. Docherty, Kenneth P. Melzer, The world s first supercritical boiler FW-Benson vertical PC Boiler The Long view power project, by Power Gen Europe, Colonge, Germany, May 26-28 (2009) 3. Balakrishnan T. and Balarathinam V., Introduction of supercritical / ultra supercritical technology in India, Tiruchirapalli, India Energex (2008) 4. Srinivas T. and Gupta A.V.S.S.K.S., Thermodynamic analysis of Rankine cycle with generalization of feed water heaters, Journal of the Institute of Engineers (India), 87, 56-63 (2007) 5. Srinivas T., Gupta AVSSKS and Reddy B.V., Generalized Thermodynamic Analysis of Steam Power Cycle with 'n' number of Feed Water Heaters, International Journal of Thermodynamics, 10(4), 177-185 (2007) 6. Saito K. et al., Reliability of Supercritical Boiler and its Advantages, Electric Power (2004) 7. Shimogori Y. et al., Experience in Designing and Operating the Latest Ultra Supercritical Coal Fired Boiler, Power-Gen Europe (2004) 8. Gupta A.V.S.S.K.S., Satyanarayana I., Srihari B., Reddy B.V., Govindarajulu K. and Nag P.K., Thermodynamic Analysis of Supercritical Cycle, The Seventh ASME - ISHMT National Heat and Mass Transfer Conference, IGCAR, Kalpakkam, (2004) International Science Congress Association 32

500 Reheat Temperature (C) 400 300 200 Reheat inlet temperature - sliding mode operation Reheat inlet temperatureconstant pressure mode operation 100 10 20 30 40 50 60 70 80 90 100 Load (%) Figure- 9 Reheat Inlet Temperature control for both constant pressure and sliding pressure operation at different loads 16 800 Reheat Temperature (C) 700 600 500 Rated Steam Temperature Control at 586 C Reheat outlet temperaturesliding pressure mode operation Reheat outlet temperature - constant pressure mode operation 400 10 20 30 40 50 60 70 80 90 100 Load (%) Figure-10 Reheat Outlet Temperature control for both constant pressure and sliding pressure operation at different loads 16 International Science Congress Association 33

650 600 Water & Steam Temperature ( 0 C) 550 500 450 400 350 300 250 Economiser Inlet Economiser Outlet Reheater Inlet Reheater Outlet Superheater Inlet Superjheater Outlet 200 0 1000 2000 3000 4000 Steam Flow (TPH) Figure-11 Static Characteristics Steam and Water flow in Boiler 9. Shinotsuka N. et al., Application of High Steam Temperature Counter measure in High Sulfur Coal- Fired Boilers, Electric Power (2003) 10. Abe T. et al., Design and Operating Experience of Supercritical Pressure Coal Fired Plant, Electric Power (2003) 11. The statistics on Supercritical Boiler use is From Power Magazine, July, (2002) 12. Singapore, Dincer I. and Muslim H.A., Thermodynamic Analysis of Reheat Cycle Steam Power Plants, Int. J. Energy Research, 25, 727-739 (2001) 13. Habib M.A., Said S.A.M. and Al-Zaharna, Thermodynamic optimization of reheat regenerative thermal-power plants, Journal of Applied Energy, 63, 17-34 (1999) 14. Ibrahim A.H., Second law analysis of the reheatregenerative Rankine cycle, Energy Conversion and Management, 38(7), 647-658 (1997) 15. Fukuda Y. et al., Application of High Velocity Flame Sprayings for the Heat Exchanger Tubes in coal Fired Boiler, Int. Thermal Spraying Conf. May, Osaka, (1995) 16. Joachim Franke, SIEMENS AG, Germany, Ponnusami K Gounder, CETHAR VESSELS LTD, V.Balarathinam, CETHAR VESSELS LTD, Reheat steam temperature control concept in Once-through boilers, (2008) 17. Mark Richardson, Yoshihiro Kidera, et.al, Supercritical Boiler Technology Matures, (2008) 18. Leading the Industry in Supercritical Boiler Technology, ALSTOM (2007) 19. Dev Nikhil, Attri Rajesh et.al., Thermodynamic and the Design, Analysis and Improvement of Heat and Power System, Research Journal of Recent Sciences, 1(3), 76-79 (2012) International Science Congress Association 34