Venting Supplement Saf-T Vent 3" venting Special gas vent system vent and combustion air supplement for 3" diameter venting Hazard definitions

Similar documents
GOLD. Venting Supplement. Water Boiler Series 3 & 4. for 3" venting

GOLD GV. Venting Supplement for 3 venting. Water Boiler Series 3 & 4

GOLD GV. Venting Supplement. Water boiler Series 3. Special gas vent system vent and combustion air supplement. Hazard definitions.

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

Vent Supplement Ultra-80, -105, -155, -230 & -310

PVC, CPVC, PP & SS Vent Supplement

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

User s Information Manual

GOLD. User s Information Manual. Water Boiler Series 4

User s Information Manual

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

User s Information Manual

User s Information Manual

Esteem 399 Low NOx Gas Fired Boiler

MC Series Gas-Fired Heating Appliance

GOLD CGt. User s Information Manual. Natural gas-fired water boiler with tankless heater

User s Information Manual

GWC. User s Information Manual. Gas-Fired Water Boilers. Model

Installation & Operation Manual Models: Starting Serial #H07H

Residential Gas Hybrid Water Heater

PVC, CPVC, PP & SS Vent Supplement

Elite. User s Information Manual. Elite and Elite VWH* All Models

Universal Fire Tube Boiler Wall Mount Models

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

Installation & Operation Manual Models:

PVC, CPVC, PP & SS Vent Supplement

ProLine XE Combi Boiler

User s Information Manual Models:

User s Information Manual Lynx Direct-Vent Sealed Combustion Condensing Boiler Model LX-90, LX-120, LX-150

Tankless Water Heater

Installation & Operation Manual Models:

User s Information Manual

User s Information Manual Models:

Power-Fin 4:1 HOT WATER HEATING BOILERS DOMESTIC HOT WATER SUPPLY BOILERS 1,500,000, 1,700,000 and 2,000,000 Btu/hr MODELS

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

Installation & Operation Manual Models:

Noble Fire Tube Boiler and Combi Installation & Service Manual NKC NKB

Installation & Operation Manual Models:

WHAT TO DO IF YOU SMELL GAS

Direct Exhaust Venting Kit Instructions

Installation & Service Manual Models:

Installation & Operation Manual Models: WH

Installation & Operation Manual Models:

Installation & Operation Manual Models:

Vent and air piped through a side wall (concentric termination)

GOLD CGs. Boiler Manual. Gas-Fired Water Boilers. Maintenance Parts. Installation Startup

User s Information Manual

Installation & Operation Manual Models:

Installation & Operation Manual Models:

Fire Tube Combi Boiler Installation & Service Manual Models:

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Contents. Hazard definitions

INSTALLATION AND SERVICE MANUAL

User s Information Manual Models:

Installation & Operation Manual Models:

Installation & Operation Manual Models: Series: 100 & 101

INSTALLATION AND SERVICE MANUAL. Hot Water Heating Boilers Domestic Hot Water Supply Boilers 399, ,000 Btu/hr Models

Installation & Operation Manual Models:

User s Information Manual Models:

User s Information Manual Models:

Installation & Operation Manual Models: WH

Please read before proceeding

SEPARATED COMBUSTION WARNING

Installation guide and material checklists

Operating Instructions and User s Information Manual VITOROND 200 WARNING WARNING IMPORTANT. Read and save these instructions for future reference.

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

SEPARATED COMBUSTION. General WARNING

Introduction Engineering and Design Manual

Aqua Balance. Direct Exhaust Venting Kit Instructions

INSTALLATION AND SERVICE MANUAL

User s Information Manual Models: WH

User s Information Manual

Do not use this vent pipe or fittings for venting incinerators of any kind.

Manual Addendum. This Addendum needs to be used in conjunction with the Evergreen Boiler Manual P/N _0518

AquaBalance SERIES 2 WALL MOUNT GAS-FIRED WATER BOILER Boiler Manual. Contents. Page. Hazard definitions

User s Information Manual Models: Starting Serial #H05H

Installation & Operation Manual Models: 502, 752, 1002, 1302, 1501, 1701, and 2001 Up To 5:1 Turndown Beginning with Serial #

Inspection Checklist Mechanical Rough in

User s Information Manual Models:

SEPARATED COMBUSTION. General

Contents. Hazard definitions

ASX7-5-IOM-3 J

User s Information Manual Models:

INSTALLATION AND SERVICE MANUAL

Boiler Manual. Wall Mount Gas-Fired Water Boilers 70/110/155

NTI TRINITY Ti INSTALLATION AND OPERATION INSTRUCTIONS Ti Boilers and Ti Combi Models VERSION DATE:

Installation Operation Maintenance

Outdoor Armor Water Heater Installation & Operation Manual Models:

Aqua Balance. Boiler Manual WMB-80/120/155. Wall Mount Gas-Fired Condensing Boilers Combi and Heating Only Models. Quick Start Guide Pages 3 & 4

2012 INTERNATIONAL FUEL GAS CODE VENTS

PVC, CPVC, PP & SS Vent Supplement WARNING

PVC, CPVC, PP & SS Vent Supplement

WHAT TO DO IF YOU SMELL GAS

INSTALLATION AND SERVICE MANUAL

INSTALLATION INSTRUCTIONS

ASX7-4-IOM-6 J

INSTALLATION INSTRUCTIONS

Page. Hazard definitions

FreeStyle Wall Mount Gas-Fired Condensing Boilers Combi & Heat Only Models

INSTALLATION INSTRUCTIONS G2D93CT, G2D93CU, G2D95CT, & G2D95CU High Efficiency Multiposition Gas Furnace with System Sentry Control System WARNING

Transcription:

GOLD GV Water Boiler Series 3 & 4 Venting Supplement 3" venting Special gas vent system vent and combustion air supplement for 3" diameter venting Heat-Fab, Inc. AL29-4C Stainless Steel Special Gas Vent System may be used in new installations of GV-3 through GV-6 boilers. Hazard definitions The following defined terms are used throughout these Instructions to bring attention to the presence of hazards of various risk levels or to important information concerning the life of the product. Indicates presence of hazards that will cause severe personal injury, death or substantial property damage. Indicates presence of hazards that can cause severe personal injury, death or substantial property damage. Indicates presence of hazards that will or can cause minor personal injury or property damage. Indicates special instructions on installation, operation or maintenance that are important but not related to personal injury or property damage. To the installer: This Venting Supplement must only be used by a qualified installer/service technician. Read these Instructions completely before beginning the installation. Failure to follow all instructions can cause severe personal injury, death or substantial property damage. To install a new vent system follow instructions in: This Venting Supplement. GV Boilers Vent/Air Intake Termination Assembly Instructions, if using Weil-McLain Vent/Air Intake Termination Kit. OR GV Water Boiler Series 3 & 4 Direct Vent Through-Roof or Through- Unused-Chimney Venting Supplement, if using Weil-McLain Through-Roof or Through-Unused-Chimney Termination Kit. manufacturer s instructions supplied with vent material. For installations above 5,500 feet use only direct vent (ducted combustion air) when sidewall venting. All of the vertical (through-roof or throughunused-chimney) methods in this Venting Supplement are acceptable and can result in severe personal injury, death or substantial property damage if ignored.

GOLD GV Series 3 & 4 Venting Supplement for 3" venting Combustion air supply Special note Refer to GV Boiler Manual for sizing free area of combustion/ventilation air openings. All boilers experience some condensation in section assembly during start-up. Unlike most conventional boilers, condensation is minimized in the GV Boiler by a built-in mixing system, maintaining boiler return water temperature above 130 0 F, during steady state operation. Flue gas condensate is slightly acidic. In most cases ph level is not harmful to vents or drains. When combustion air is contaminated by vapors from products and areas, listed in Table 1 below, condensate acidic levels increase. Higher acidic levels attack many materials, including stainless steel commonly used in high efficiency systems. You may choose to use outside combustion air for any of the following reasons: Installation is in an area containing contaminants listed in Table 1 below, which will induce acidic contamination. You want to reduce infiltration into your home through openings around windows and doors. Table 1 Corrosive contaminants Products to avoid Spray cans containing chloro/fluorocarbons Permanent wave solutions Chlorinated waxes/cleaners Chlorine-based swimming pool chemicals Calcium chloride used for thawing Sodium chloride used for water softening Refrigerant leaks Paint or varnish removers Hydrochloric acid/muriatic acid Cements and glues Antistatic fabric softeners used in clothes dryers Chlorine-type bleaches, detergents, and cleaning solvents found in household laundry rooms Areas likely to have contaminants Dry cleaning/laundry areas and establishments Swimming pools Metal fabrication plants Beauty shops Refrigeration repair shops Photo processing plants Auto body shops Plastic manufacturing plants Furniture refinishing areas and establishments New building construction Remodeling areas Garages with workshops Adhesives used to fasten building products and other similar products To prevent the potential of severe personal injury or death, check for areas and products listed above before installing boiler. If found: remove products permanently OR provide outside combustion air 2

GOLD GV Series 3 & 4 Venting Supplement for 3" venting Vent termination Venting method definitions Direct vent Uses outside combustion air with combustion air connector piping sealed at all joints and seams. Also known as sealed combustion. Non-Direct vent Uses inside combustion air with no combustion air connector piping. Properly locate vent termination Follow instructions on this page when determining vent location to avoid possibility of severe personal injury, death or substantial property damage. 1. When using direct vent method Refer to separate instructions packed with Weil-McLain direct vent termination kit and vent pipe manufacturer's instructions for additional locations. 2. For location of non-direct vent vertical termination, see vent pipe manufacturer's instructions. 3. Gases will form white plume in winter. Plume could obstruct window view. 4. Prevailing winds could cause freezing of condensate and water/ice buildup on building, plants or roof. 5. Locate or guard vent to prevent accidental contact by people or pets. 6. Do not terminate vent in window well, stairwell, alcove, courtyard, or other recessed areas. 7. Non-Direct vent installations only Vent must terminate more than 4 feet below or to side of all doors or windows. 8. Vent must terminate more than 1 foot above grade or anticipated snow line. In addition, vent termination must be at least 7 feet above public walkway and 3 feet above any forced air intake within 10 feet. Stay well away from trees, shrubs, and decorative items. Site conditions may dictate greater clearances. See Figure 1. 9. Vent must terminate at least 4 feet horizontally, and in no case above or below, unless a 4 foot horizontal distance is maintained, from electric meters, gas meters, regulators, relief valves, and other equipment. 10. Locate or guard vent to prevent condensate from damaging exterior finishes. 11. Do not extend exposed vent pipe outside of building. Condensate could freeze and block vent pipe. 12. Vent must terminate at least 6 feet away from adjacent walls. 13. Do not terminate vent closer than 5 feet below roof overhang. 14. Do not terminate vent above any door or window. Condensate can freeze, causing ice formations. 15. Do not use existing chimney as raceway if another appliance or fireplace is vented into or through chimney. 16. Do not connect: Any other appliance to vent pipe. Multiple boilers to a common vent pipe. 17. Do not wrap or insulate vent pipe and fittings. 18. Canadian installations See B149.1 or B149.2 Installation Code. 19. A gas vent extending through an exterior wall shall not terminate adjacent to the wall or below building extensions such as eaves, parapets, balconies or decks. Failure to comply could result in severe personal injury, death or substantial property damage. Figure 1 Vent termination locations Forced air intake 3 feet If within 10 feet 1 foot 1 ft 1 ft 7 feet 1 ft Public Walkway 26507 Snow 26508 3

GOLD GV Series 3 & 4 Venting Supplement for 3" venting Installation Pre-installation planning 1. Follow national, state, local or provincial codes or regulations when venting GV boiler. 2. Choose vent method from those shown on page 5. 3. Select vent run components from Table 2. Table 3 states maximum vent run lengths and number of elbows. Do not exceed data in Table 3. See Figure 2 for slightly reduced boiler output. 4. If installing with direct vent method, use same maximum run length and number of elbows from step 2. Vent and combustion air connector piping configurations must match. Use suitable 3" material for combustion air connector piping, such as: Dryer vent Galvanized steel PVC (3" I.D.) 5. Refer to vent termination WARNING, item 19 on page 3. Table 2 Parts list Description Weil-McLain Part Number Heat-Fab, Inc. Part Number GV starter tee 699-999-025 73WMSTXL GV termination coupling 699-999-001 73WMTERM 45 o elbow 699-999-010 7311GC 90 o elbow 699-999-011 7314GCTR 6" pipe 699-999-003 7301GC 12" pipe 699-999-004 7302GC 18" pipe 699-999-005 7304GC 18" slip connector (Note 1) 699-999-009 7324GC 24" pipe 699-999-006 7305GC 37 ½" pipe 699-999-007 7307GC 49 ½" pipe 699-999-008 7308GC Horizontal support 699-999-016 7323GC Weil-McLain Vent/Air Intake Termination Kit 382-200-430 -- Weil-McLain Through-Roof or Through-Unused-Chimney Termination Kit 382-200-435 -- Notes 1. Use to adjust for non-standard pipe lengths and before termination coupling to terminate run. Table 3 Vent and combustion air connector piping lengths and number of elbows Maximum vent length (feet) Total number of elbows 0 2 3 4 5 6 7 8 GV-3 thru GV-5 100 80 70 60 50 40 30 20 Figure 2 % Output Boiler output 100 99 98 97 GV-6 GV-3 GV-4 GV-5 GV-6 80 60 50 40 30 20 10 -- 96 26500 95 0 20 40 60 80 100 Total equivalent length (feet) of vent (from boiler to vent termination) 4

GOLD GV Series 3 & 4 Venting Supplement for 3" venting Installation continued Select vent method For altitudes more than 5,500 feet above sea level Do not use non-direct vent through sidewall methods as shown in Figures 4 and 6 below. Can cause severe personal injury, death or substantial property damage if ignored. Figure 3 GV direct vent through sidewall (using Weil-McLain Vent/Air Intake Termination Kit) Slope vent pipe downward, toward boiler, minimum ¼ per foot. Slope Vent pipe Figure 4 GV non-direct vent through sidewall (using Weil- McLain Vent/Air Intake Termination Kit) (See WARNING above.) Vent pipe Air pipe Slope vent pipe downward, toward boiler, minimum ¼ per foot. Slope 26501 26502 Figure 5 GV direct vent (using Weil-McLain Through-Roof or Through-Unused-Chimney Termination Kit) Figure 6 GV non-direct vent through sidewall (using termination coupling) (See WARNING above) Figure 7 GV non-direct vent through roof (See WARNING above) Slope vent pipe downward, toward boiler, minimum ¼ per foot. Slope vent pipe downward, toward boiler, minimum ¼ per foot. Slope vent pipe downward, toward boiler, minimum ¼ per foot. 26504 26505 26503 5

GOLD GV Series 3 & 4 Venting Supplement for 3" venting Installation assembly Connect to boiler Follow the instructions in the GV Boiler Manual to connect the to the boiler. Construct vent and optional combustion air run Follow vent pipe manufacturer's instructions for sealing the vent. Vent and combustion air connector piping must be sealed gas-tight to prevent possibility of flue gas spillage and carbon monoxide emissions, resulting in severe personal injury or death. 1. Follow manufacturer's instructions to construct vent run and for methods of supporting vent runs. Clean joints before sealing. See vent pipe manufacturer's instructions to clean joints. Use their specified sealant (maximum 250 0 F flue temperature). Do not use screws. Do not mix types or manufacturers of vent materials. Maintain minimum one-inch clearance from combustible materials to vent pipe; 0" clearance for noncombustible materials. Install vent pipe with seams on top of vent runs. If needed, use slip connector to adjust for nonstandard pipe lengths. See vent pipe manufacturer's instructions for use. 2. If installing with direct vent through sidewall method, use instructions provided with Weil-McLain Vent/Air Intake Termination Kit. See Figure 3 page 5. Connect vent run to termination Venting through sidewall 1. If using Weil-McLain Vent/Air Intake Termination Kit, see instructions provided in that kit. Applies to direct (Figure 3, page 5) or non-direct vent (Figure 4, page 5) method. 2. If using non-direct method with termination coupling only, see Figures 8 and 9. Do not seal slip connector to inside or outside plate. If passing through noncombustible wall, provide hole diameter large enough to insert the slip connector through. Sleeve and spacers are not required. 3. Maintain minimum one-inch clearance from combustible materials to vent pipe; 0" clearance for noncombustible materials. 4. Refer to vent termination WARNING, item 19 on page 3. Venting through existing chimney or roof 1. Direct vent method follow instructions supplied in Weil-McLain Through-Roof or Through-Unused-Chimney Termination Kit to assemble termination. 2. Non-Direct vent method (only through the roof, not through chimney): Vent pipe must extend through roof flashing, jacket or thimble. See Figure 10. Vent may pass through floor, inside wall or concealed space when installed according to vent pipe manufacturer's instructions. 2. Maintain minimum one-inch clearance from combustible materials to vent pipe. 6

GOLD GV Series 3 & 4 Venting Supplement for 3" venting Installation assembly continued Figure 8 Sidewall termination installation (non-direct venting) ¼" to ¾" between stop on termination and metal plate 4" Galvanized sleeve (within 4-1/8" hole for combustible wall) 1/8" Slip connector, 3" Pipe section Metal plate Band clamp Spacer to support sleeve on vent Termination coupling Sealant Metal plate 26509 Figure 9 Non-direct vent through sidewall (using termination coupling) Follow manufacturer s instructions for proper installation of vent runs, including slope and support. Figure 10 Non-direct vent through roof Follow manufacturer s instructions for proper installation of vent runs, including slope and support. 26504b 26505b 7

GOLD GV Series 3 & 4 Venting Supplement for 3" venting Installation assembly continued Finish the vent installation Installing condensate tubing Figure 11 Installation of condensate tubing 1. See Figure 11 to install condensate tubing (provided by others). Use condensate pump if floor drain is higher than condensate drain on boiler. If required: use a low-profile pump OR set boiler on foundation (see GV Boiler Manual) to allow gravity flow to discharge. 2. Size pump in gal/hr (boiler model): 0.78 (GV-3) 1.17 (GV-4) 1.56 (GV-5) 1.95 (GV-6) Refer to pump manufacturer's instructions. Drain to a non-freezing area. Vent 5/8" O.D. tubing, provided by others 26506 If vent pipe or combustion air pipe must be reassembled When vent pipe or combustion air pipe is disconnected for any reason, it must be reassembled and resealed according to this Venting Supplement, the direct vent termination kit instructions and the vent pipe manufacturer's instructions. Sealant recommended by vent pipe manufacturer must be used as indicated in their instructions. Vent and combustion air connector piping must be sealed gas-tight to prevent possibility of flue gas spillage and carbon monoxide emissions, resulting in severe personal injury or death. 8