INSTRUCTIONS for installation and operation of electrical direct-heating convector PROTHERM

Similar documents
ECOLEC PANEL HEATERS GENERAL NOTES.

INSTRUCTIONS AND WARRANTY

CERAMIC TOWER FAN HEATER PL2000

INSTALLATION MANUAL & OPERATING INSTRUCTIONS

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

Models: RP-10, RP-15, RP-20. User Manual

AP24MT, AP24ET, AP15ET, AP10ET. Convection Panel Heaters. Instruction Manual

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

ELECTRIC CONVECTOR HEATER. This product is only suitable for well insulated spaces or occasional use.

Installation Instructions & Operating Manual IMPORTANT

INSTALLATION & USER INSTRUCTIONS

MICATHERMIC PANEL HEATER

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

2 KW OIL FILLED RADIATOR

INSTALLATION & USER INSTRUCTIONS

Manual for Ceiling Patio Heater

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

Oil-filled Radiator NY23EC-11L User Manual

FAN HEATER FH118 User Manual

PTC Tower Heater. Instruction Manual THE SCIENCE BEHIND HEAT.

INSTALLATION & USER INSTRUCTIONS

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER

ONE. User Manual. Heating Element and Electric Radiator

OWNERS INSTRUCTION MANUAL

QUALITY SPACE HEATERS

OPERATING INSTRUCTIONS

Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

900W OIL FILLED RADIATOR

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

WALL HUNG FIRE Model: LDBL2000A-DD4BR Ref:22217

ST E /ST E / ST E / ST E ST E / ST E / ST E

Instructions for Operation and Maintenance of Containers

2 KW OIL FILLED RADIATOR

16 XD Mk2 Inset Electric Fire

INSTRUCTIONS AND WARRANTY

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

Contact Details. Please note that some of the contact details on this PDF document may not be current.

AirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation

General Care and Safety Guide

INSTALLATION & USER INSTRUCTIONS

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

INSTALLATION & USER INSTRUCTIONS

quality european heating appliances

16 Ultiflame Inset Electric Fire

General Care and Safety Guide

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

Portable Electric Patio Heater User's manual

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

17 OPERATING AND INSTALLATION MANUAL - EN

Instruction manual. Remote control electric IR HEATER

Dear Customer. Contents. 1) Vantage Electric Radiator characteristics Pag.3. 2) Technical specifications Pag.3. 3) Warnings Pag.4

USER S INFORMATION MANUAL

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

Installation and user manual

AH-470. Flat Panel Micathermic Space Heater OWNERS MANUAL. Read and save these instructions.

OIL FILLED RADIATOR Instruction manual

Dayton Electric Infrared Fireplace User Manual

IMPORTANT: RETAIN FOR FUTURE REFERENCE

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h

200W Frostwatch Radiant Heater Operation Manual

INFRARED ZONE HEATING SYSTEM

AVANT DGS. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

MILLI CUBE HEATED TOWEL RAIL 825 X 600

User's Instructions. Alpha CB50

CSH COMBINED STORAGE HEATERS INSTALLATION INSTRUCTIONS AND USER GUIDE

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Convection Panel Heater

OPERATING AND INSTALLATION MANUAL

Instruction Manual. Portable Air Conditioner

Conception Wall Fire. Instruction Manual THE SCIENCE BEHIND CLEAN.

USER S INFORMATION MANUAL

User Guide PLEASE READ BEFORE USE AND KEEP FOR FUTURE REFERENCE.

2.8KW ELECTRIC FAN HEATER

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use.

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

Industrial infrared heater IR For premises with large volumes and high ceilings

INSTRUCTIONS AND WARRANTY

1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA

instructions OIL FILLED RADIATOR V V and V551225

General Care and Safety Guide

Instruction Manual. Oil Heaters. Model: OIL5, OIL7, OIL9 & OIL11T READ AND SAVE THESE INSTRUCTIONS

INSTALLATION MANUAL Wolfen Slimline Hand Dryer Stainless Steel. Installation Details Warranty

CLASSIC PLUS INFRARED ZONE HEATER

Charlotte CRT20AB, Charlotte CRT20BR & Brookline BKL20

Q1 - Q2 - Q3 - Q4 Q2

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

5KW ELECTRIC FAN HEATER

SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

How to install and use your storage heater

WHE 2.24 / WHE 2.24 FF

Elztrip EZ100. Elztrip EZ100. Single panel radiant heater for offices, shops etc. Product specifications

!""#$# !%&'())('*+%,-, #./0('*%1,!%&'023'*+%&

FLCH4R Garage and Utility Electric Heater

TF1800 Thermofan Installation Guide YOUR STEP-BY-STEP GUIDE TO THE PERFECT INSTALLATION

Transcription:

INSTRUCTIONS for installation and operation of electrical direct-heating convector PROTHERM PROTHERM, s.r.o. [Ltd] 909 01 Skalica, Pplk Pljušťa 45, Slovak Republic phone: +421 346966101 fax: +421 346966111

1 Function of an Electrical Convector A convector is a heating device the function of which is based on conversion of electrical energy into heat and on the upward flow of warm air. It uses traditional principles of electrical heating and the chimney effect in an advanced combination. Thus, an electrical conveyor forms something like a small chimney fitted with an electrical heating element in its bottom part. The element heats air which then flows upwards inside the convector and into the room it is heating. Cooler air drops down, the convector takes it in, reheats it and returns it back to into the room. Therefore, we can call the convector a chimney radiator, which can function without a fan, silently and efficiently. To achieve a pleasant temperature in a room, only minimum consumption of 30 W per cu.m is required. 1 - cold air 2 - heat exchanger 3 - heating element 4 - wall 5 - thermostat sensor 6 - warm air Fig. 1: Diagram of the chimney effect

Te convector is a modern version of the tried-and-tested hot-air heating. The convector is equipped with a thermostat for controlling the required room temperature between 5 C and 30 C. If more than one convectors are used connected to an independent power supply, the temperature can be regulated by a central room thermostat or a programmable regulator. The convector is fitted with a thermal fuse which cuts out the power supply to the convector in case of overheating. power switch thermostat control Fig. 2: Convector control panel 2 Technical Specifications Output (W): 500, 1000, 1500, 2000 The convector output is specified on the product labelling and also on the heating element body for service purposes. Regulation range: 5 C - 30 C Nominal voltage: 230 V± 10 %, 50 Hz Dimensions and weight Type dimensions (mm) weight (kg) 0,5 kw 455 x 460 x 75 6,1 1 kw 455 x 460 x 75 6,1 1,5 kw 610 x 460 x 75 7,8 2 kw 765 x 460 x 75 9,6

3 Use The electrical convector can be used: - as an additional heating device to a current heating system (it can be easily plugged into an electrical socket) - for comprehensive heating of flats, houses, offices, etc. at the attractive electricity rate BP. 4 Location and Installation The convector is designed to be used in a normal environment AA5/AB5 as per ČSN 33 2000-3 and ČSN 33 2000-5-51 (i.e. ambient temperature + 5 C to + 40 C, humidity depending on temperature up to max. 85%). The wall on which the convector is mounted must be non-flammable (non-flammable materials classified in group A as per ČSN 73 0832). The convector must not be installed in rooms with a bath, bathrooms, wash rooms and showers, in zones 0, 1 and 2 as per ČSN 33 2000-7- 701. It may not be installed also in zones 3 if there is a possible occurrence of water jets used for cleaning in municipal spas (municipal spas are baths and showers used in schools, factories, sports clubs, etc., including any other such facilities for public use). If used in zone 3, extra local interconnection must be done as per ČSN 33 2000-7-701. Convector must not be installed directly under the mains plug! Wiring to a power mains and electrical installation must be performed only by an authorized person, qualified under Regulation No. 718/2002 Z.z. Colour coding of conductors (to the fixed terminals in the preinstalled flushmounted wall conduit box): protective conductor yellow-green central conductor light blue phase conductor - brown Electrical convector control is designed to be operated by persons without any electro-technical qualification. The person operating the convector may adjust only the controls specified in these Operating Instructions!

Assembly suspension on a wall is depicted in Fig. 3. Fig. 3: Wall mounting In order for the convector to function to your absolute satisfaction, the following conditions must be met: - it must be mounted (we recommend suspended on a wall) so that the bottom edge is at least 15 cm above the floor, - the convectors bottom and top openings must be free of obstacles to allow for unobstructed circulation of air, - foreign objects (furniture) must not obstruct air circulation, and must be located at least 20 cm from the front, top and side walls of the convector. 5 Operation Start the convector by switching on the power switch (see Fig.2). Set the thermostat controller to the maximum temperature position. Heat the room until the required temperature is achieved (check the room thermometer). Then turn the thermostat controller back towards a lower temperature until the convector switches off. Leave the thermostat in this position. The room temperature shall automatically be maintained at the selected value.

Caution: During the first start up of the convector a slight odour might be perceived, which is caused by the burn-off of residues inside the convector. After longer time of not using convector (summer, holiday...) after restarting up it could appear slight odour caused by the burn-off dust on the heating elements. ATTENTION! To prevent overheating, do not cover over convector! 6 Thermal Fuse The convector is fitted with a fuse that cuts out the power supply to the heating element in case of convector overheating. This condition could arise only if you prevent the free circulation of air through the convector (unsuitable location of convector, covered convector air ducts, e. g. towel, etc.). After cooling the fuse is reset and the convector can be operated again. 7 Maintenance The convector does not require any special maintenance. We recommend normal cleaning of the surface with a moist cloth and detergent. The convector must be switched off before cleaning. Dust can be removed from slits by vacuuming. 8 Failure and Repair In case of convector failure, first check that the convector switch is turned on, and that the convector is plugged into a power socket. If it is, then check the thermostat setting and free circulation of air. If these measures do not help, seek advice from an authorized service centre. Service is provided by the dealer. 9 Delivery The convector is supplied with a connected cable, 150 cm long, without terminal. The delivery also contains a special bracket for wall mounting.

10 Warranty The supplier provides a warranty as is set out in the Warranty Certificate and the terms and conditions therein. Any defects subject to warranty must be reported to the supplier. The Warranty Certificate and proof of purchase must be submitted when making a warranty claim. 11 Safety This product is approved under ŠS SKTC 101. The PROTHERM convector is a class 1 product, protection cover IP 31. Fig. 4: Wiring diagram