Keep your home snow and ice free with. WARMUP Outdoor Heating Solutions. From the world s best-selling electric floor heating brand

Similar documents
Design Guide. The world s best-selling floor heating brand

Polymer solutions Heating mat EM2-CM

Toll Free:

CATALOG. Toll Free:

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

F1202 TRACE HEATING. Road & Ramp

ComfortTile Floor Heating Systems

Snow melting for ramps, access ways, and footpaths

PLSRR Heat Trace Cable Data Sheet

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

Self-regulating Roof Heat and Gutter Trace Cable

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Toll Free:

Self-regulating Roof Heat Cable

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

SECTION ELECTRIC FLOOR HEATING AND SNOW MELTING EQUIPMENT

Foil Heaters. Installation Manual: TECHNICAL HELPLINE

COMMERCIAL & RESIDENTIAL MARKETS U.S. ELECTRICAL

Anti frost. Snow Melting USA 2012 USA 2014

SAFETY & COMFORT FOR THE HOME RESIDENTIAL MARKET U.S. PLUMBING CANADA PLUMBING AND ELECTRICAL

CATALOG. Toll Free:

Underlaminate Foil Heater

Technology for human beings that is, compatible with nature, creating permanent HEAT TRACING Dreams that can greatly improve the quality of life,

DS-8C RAIN/SNOW SENSOR CONTROLLER INSTALLATION INSTRUCTIONS

DS-5C RAIN/SNOW SENSOR CONTROLLER INSTALLATION INSTRUCTIONS

Drexan Energy Systems Inc.

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.

Underfloor Heating Inscreed Cable System

Installation Manual. Frost Protection Cable. Warmup Ireland Web: Telephone:

MANUAL. Type ETO2 Controller for ice and snow melting. Warmup Inc. The world s best-selling electric floor heating brand

Electric Floor Warming Systems Installation and Operation Instructions. Mat Heating Systems and Cable Heating Systems. UL Listed for USA and Canada

Toll Free:

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

Radiant Heating & Snow Melting

Toll Free:

STEP Snowmelt. Installation Manual. Low Voltage System

US: CA:

L J Visit to learn about the Danfoss Installer Certification program. Dual Self-Adhesive Mats. Installs in minutes!

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

ADDITIONAL INFORMATION

Multi-Use Freeze Protection for Pipes, Tanks and Vessels of All Types and Sizes.

ClearZone Snow Melting Systems

DISTRIBUTOR GUIDE FOR SELLING QUALITY TO CONTRACTORS

Warm Feet For Uncoupling Membrane Pour membrane de désolidarisation. Installation Guide Floor Heating Cable

Gardian W51. Approvals

QuickNet System Installation Manual Manuel d installation du système QuickNet Manual de instalación del sistema QuickNet

ELEKTRA RadiantFloor Heating

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

Ground application. Ice & Snow Melting. Application manual. Intelligent solutions with lasting effect Visit devi.com

Warmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL AUTOMATED SYSTEMS ENGINEERING ENCLOSURE TYPE 3R

Freezer Frost Heave Prevention

INSTRUCTION. Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors. Danfoss heating cable mat type 100/150

Always make sure to check the heating film before, during, and after installation of the floor covering.

Installation Instruction

Affiliations: Code Listings and Standards C O U N C I L

Principle of Operation:

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

Commercial and Residential Self-Regulating Heating Products

AKOCABLE Heating Cable Solutions Electrical Tracing

LIFETIME. INSTALLATION MANUAL emat Pro 100w/150w/200w WARRANTY

Chromalox PRECISION HEAT AND CONTROL. Cold Weather Electric Heat and Control Products

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

Electric Floor Heating & Snow Melting Solutions

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

Roof and Gutter De-Icing

ETO 2 - Controller for ice and snow melting

CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description

Product catalogue. Outdoors

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

Heating cable solutions for temperature-related problems

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES. thermal ManaGeMent.

Packaged Terminal Air Conditioner (PTAC)

COMMERCIAL HEAT TRACING. Products and Services

Electric Floor Heating Cables

57654C 02/11 (MBC) 2011 OJ Electronics A/S. Type ETR2 Ice and snow melting

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM

Tubular Industrial Process

Installation Instructions DTC-24 SNOw MELTING &

Type ETO2. Controller for ice and snow melting 67222A 04/14 (JRK) GREEN COMFORT Maximum comfort with low energy consumption OJ Electronics A/S

XL-Trace System Application and Design Guide

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

The IceFree Eave System

MARATHON HEATER. File # E Made in USA

RX1200 ROOF AND GUTTER DE-ICING CONTROLLER INSTALLATION AND OPERATION MANUAL

Floor Heating. Towel Warmers. Radiant Panels 2017/2018. Controls. Product Catalog. Snow Melting

Heating Tapes/Mats HEATING TAPES HEATING CORDS HEATING MATS DRUM HEATERS GREAT FOR HEATING SMALL TUBES! MOISTURE RESISTANT!

Packaged Terminal Air Conditioner (PTAC)

AKOCable Heating Cable Solutions Electrical Tracing

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

DIVISION LOW VOLTAGE DE-ICING / SNOW MELTING SYSTEM IN EXISTING ASPHALT/CONCRETE

ACS-30-EU-VIA-DU-20-MOD

The Laboratory is qualified to update standards identifying the test procedures.

GB-DAS. Installation and user manual DEVIreg 850 controller

Overview Frost Heave Prevention for Freezer floors on ground.

INSTALLATIONGUIDE. HotSeam TM Overview ICE ROOF

Packaged Terminal Air Conditioner (PTAC)

Transcription:

Keep your home snow and ice free with WARMUP Outdoor Heating Solutions From the world s best-selling electric floor heating brand

Applications for stairs for walkways for driveways for roofs & gutters for access ramps for flat roofs Stay safe, avoid costly accidents and eliminate the need for back-breaking shovelling. With Warmup s snow melting product range you can prevent snow and ice buildup on stairs, driveways, slippery walkways and more by maintaining a temperature just above 32 F (0 C). Our systems are triggered automatically by either a temperature or moisture-sensitive sensor and ideal where safety is paramount. Keep gutters and roofs snow and ice free with Warmup s deicing and self-regulating cables. Warmup deicing cable and heat trace system eliminate dangerous snow build up and provide freeze protection. They create a drain path needed for melted snow and ice to drain freely. IDEAL FOR COMMERCIAL AND RESIDENTIAL USE Applications in asphalt, concrete and under pavers, as well as in roofs and gutters.

For paths, driveways and stairs Snow Melting mats Warmup Snow Melting Mats are uniquely designed for snow melting in parking lots, driveways, pavements, stairs and more. The cable has a layer of shielding and insulation, suitable for low temperatures, is UV resistant and environmentally friendly, making it ideal for outdoor use. Versatile installation in asphalt, concrete or under pavers Cable, fixed to roll-out mat, is quick and easy to install Energy efficient twin-conductor heating cable of 1/4 (6mm) 10-Year Warranty Approved by CSA Operating voltage: 120V and 240V Output rating: 50 W/ft 2 (500W/m 2 ) Mat width: 2 (61 cm) Range of lengths: from 3 (91.4cm) up to 60 (1828.8cm) Maximum operating temperature: 464 F (240 C) Cold tail length: 16.4 (610cm) Area (ft²) Heaters Length (ft) Watts (W) Amps (A) Resistance (Ω) 6 WSMM-D-0300-120 3 300 2.5 48.0 10 WSMM-D-0500-120 5 500 4.2 28.8 120 Volts 20 WSMM-D-1000-120 10 1000 8.3 14.4 30 WSMM-D-1500-120 15 1500 12.5 9.6 40 WSMM-D-2000-120 20 2000 16.7 7.2 50 WSMM-D-2500-120 25 2500 20.8 5.8 60 WSMM-D-3000-120 30 3000 25.0 4.8 6 WSMM-D-0300-240 3 300 1.3 192.0 10 WSMM-D-0500-240 5 500 2.1 115.2 20 WSMM-D-1000-240 10 1000 4.2 57.6 240 Volts 30 WSMM-D-1500-240 15 1500 6.3 38.4 40 WSMM-D-2000-240 20 2000 8.3 28.8 50 WSMM-D-2500-240 25 2500 10.4 23.0 100 WSMM-D-5000-240 50 5000 20.8 11.5 120 WSMM-D-6000-240 60 6000 25.0 9.6

For roofs and gutters Roof & Gutter Deicing Cable (constant wattage) The Warmup Roof & Gutter Deicing cable (Constant Wattage) has been designed for the purpose of preventing ice buildup [i.e. ice dams] which form on roofs, gutters and downspouts. The resistance-heating element is UV resistant and environmentally friendly, making it ideal for outdoor use. UV resistant cable Available in a wide range of lengths to suit your requirements Roof cable can be wired to operate together with snow melting mats for a complete roof/ground application Dual conductor cable, one-point connection 10-year Warranty Approved by CSA Operating voltage: 120V and 240V Cable heat output: 5.5 watts/ linear foot Maximum operating temperature: 464 F (240 C) Cold tail length: 16.4 (610cm) Thickness: 3/8 (9.5mm) Length (ft) Heaters Wattage (W) Amps (A) Resistance (Ω) 28 WRGH-D-120V-18W/150 150 1.3 92.3 120 Volts 62 WRGH-D-120V-18W/350 350 2.9 41.4 88 WRGH-D-120V-18W/475 475 4.0 30.0 156 WRGH-D-120V-18W/850 850 7.1 16.9 219 WRGH-D-120V-18W/1200 1200 10.0 12.0 93 WRGH-D-240V-18W/500 500 2.1 114.3 176 WRGH-D-240V-18W/950 950 4.0 60.0 240 Volts 250 WRGH-D-240V-18W/1300 1300 5.4 44.4 312 WRGH-D-240V-18W/1700 1700 7.1 33.8 437 WRGH-D-240V-18W/2400 2400 10.0 24.0 625 WRGH-D-240V-18W/3400 3400 14.2 16.9 28 WRGH-D-120V-18W/150-KITGF 150 1.3 92.3 120 Volts Kits 62 WRGH-D-120V-18W/150-KITGF 350 2.9 41.4 88 WRGH-D-120V-18W/150-KITGF 475 4.0 30.0 156 WRGH-D-120V-18W/150-KITGF 850 7.1 16.9 219 WRGH-D-120V-18W/150-KITGF 1200 10.0 12.0 You can also use Self-regulating Cables for Roof & Gutter applications. See next page for more info.

For pipes and gutters Self-regulating Cable Warmup Self-regulating cable is ideal for keeping metal and plastic pipes warm in commercial and residential construction, institutional buildings and some industrial freeze protection applications. The nature of the self regulating cable causes its output of 3, 5 or 8 W/linear foot to vary automatically with the outside conditions, thereby guaranteeing the safeguard of ducts and pipes. Available in 3, 5, and 8 watts per linear foot For use on metal and plastic pipes Available in pre-terminated kits or stock spools of 500ft Easy to install, the self-regulating cable can be cut to any length in the field. Energy efficient, the self-regulating cable uses less energy when less heat is required. 10-year Warranty CSA approved Voltages: 120, 208-277V Maximum maintenance temperature: 100 F (38 C) Maximum exposure temperature: 185 F (85 C, power off) Approximate size: 3/8 W x 1/8 H (9.5x3mm) Industrial Grade: 16 AWG Buss Wire Minimum Bend Radius 1-1/8 Circuit Lengths: up to 660 ft 120 Volts Length (ft) Systems Wattage (W/lin) 500 NAMSR-3W-120V 3 500 NAMSR-5W-120V 5 500 NAMSR-8W-120V 8 240 Volts 120V Kits 500 NAMSR-3W-240V 3 500 NAMSR-5W-240V 5 500 NAMSR-8W-240V 8 6 NAMSRK-6FT 5 12 NAMSRK-12FT 5 18 NAMSRK-18FT 5 24 NAMSRK-24FT 5 50 NAMSRK-50FT 5 CRDS-15 / 6ft lead with 3-prong molded plug, Nema 5-15p, 15 amp, 14/3 CRDS-15-GFI / 6ft lead with GFCI 3-prong molded plug, Nema 5-15p, 15 amp, 14/3 NOTE: To use Self-regulating Cables in Roof & Gutter applications, choose between NAMSR-5W-120V, NAMSR-5W-240V and the 120V kits. v0611

Controllers All-in-one Sensor/Controller (ASE-DS2/5) The Warmup All-in-one sensor/controller (ASE-DS2/5) has a built-in sensor to automatically activate the snowmelt heaters. It is ideal for projects like stairs and driveways. Backed with a 1-Year Warranty. ASE-DS2 (30A) ASE-DS5 (60A) Sensors & controller in one outdoor unit Full access to electronics for manual overrides Automatic activation - only on when needed Rain, snow and temperature detection Heaters connect directly into unit for simplicity Adjustable delay-off drying cycle Adjustable temperature trigger point Remote control and monitor capabilities CSA approved Operating voltage: 100-120V / 220 / 240V, 50-60 Hz Heating load: 30A@240VAC (DS2) and 60A@240VAC (DS5) Temperature range: -40 F/+185 F (-40 C/+85 C) Trigger temperature: 34 F/44 F (1.1 C/6.6 C) Dimensions: 4.7 H x7 W x2.7 D (120x178x70mm) Housing: weatherproof enclosure

Controllers Snowmelt Advanced Thermostat The Warmup Snowmelt Advanced Thermostat (USET02) is used for multiple-zone projects such as a combined roof and ground application. The system automatically activates via readings from temperature and moisture sensors. Backed with a 1-Year Warranty. 2 zone control in one unit. Can control roof, ground or roof & ground zones Can be switched to standby or forced on to override timer settings in extreme weather conditions Economical control of ice and snow melting Indoor mounting Electronic on/off control up to 11 KW Detection of temperature and moisture Alarm relay for external signal CSA approved Operating voltage: 120V / 240V, 50-60 Hz Output rating: 11 kw Output relay: 3 x 16A Temperature range: 32/50 F ( 0/+10 C) Housing: IP20 Dimensions: 3.5 H x 6.1 W x1.8 D (90x156x45mm) Dimensions (with box): 6.7 H x 6.4 W x1.8 D (170x162x45mm) US92023 (mounting box) ETOG-55 (ground) ETF-744/99 (temp) ETOR-55 (roof)

Insulation board Insulation board Warmup Insulation board is made of waterproof extruded polystyrene with a fiberglass mesh embedded on each face into a cement polymer adhesive. Easy to cut with a knife, it installs to any surface and is ready for thinset and tiles. Free of harmful asbestos, this board poses no health or safety risks and is unaffected by the freeze/thaw cycle. Maximum tile loading weight [CERAM121107]: 62 kg/m 2 (12.7 lb/ft 2 ) Density: 290 kg/m 3 (19.5 lb/ft 3 ) Thermal conductivity initial [DIN 52612]: 0.19 BTU.in./hr.ft 2. F (0.027 Watt/mK) Thermal conductivity (5 years) [BS EN 13164]: 0.22 BTU.in./(hr.ft2. F) (0.33 Watt/mK) Compressive strength [BSEN 826]: 6144 lb/ft 2 (0.30N/mm2) Water absorption (immersion) [ISO2896]: 0.2% by vol Water absorption (capillary) [DIN 53428]: Nil Coefficient of linear expansion: 30 x 10-6 K-1 Flammability [DIN 4102]: B1 Impact sound reduction [BS-ISO140-8]: dlw = 21 10 Kingsbridge Garden Circle, Suite 704, Mississauga, ON L5R 3K6 Canada Toll Free: 1-888-5-WARMUP/ 1-888-592-7687 Landline: 905-990-2075 Fax: 905-990-1732 ca@warmup.com www.warmup.ca Warmup Inc. 52 Federal Road, Unit 1F, Danbury, Connecticut, CT 06810 USA Toll Free: 1-888-WARMFEET / 1-888-927-6333 Fax: 1-888-927-4721 us@warmup.com www.warmup.com YOUR LOCAL WARMUP DEALER: The WARMUP word and associated logos are trade marks. Warmup Plc. 2011 Regd. TM Nos. 1257724, 4409934, 4409926, 5265707. E & OE. V032011