Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Similar documents
Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

CONDENSERS AND CONDENSING UNITS

ALL PRODUCTS BROCHURE

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Innovative Design, Performance, & Serviceability

THE ULTIMATE ROOFTOP SOLUTION

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

From 230 tons to. Water-Source Heat Pump Products. Premium Performance Environmentally Friendly Superior Construction

Water-Source Heat Pumps

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

RoofPak Applied Rooftop Systems

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Tulsa, OK Longview, TX

Energy Recovery with Cooling and Heating Model ERCH

Cultivator & Hybrid Cultivator

Maverick II Commercial Rooftop Systems 15 to 75 tons

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Energy Recovery with Cooling and Heating

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

Commercial Packaged Rooftop Systems

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

Best Practices for Applied Rooftop ` Systems - Application and. Jerry Cohen President Jacco & Assoc. Installation

RT-OA TM Rooftop Outdoor-Air (DOAS)

62DA,DB,DC,DD,DE,DF07-38

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Modular Supply Make-Up Air Unit

Best Practices for Applied Rooftop ` Systems, Applications and. Jerry Cohen President Jacco & Assoc. Installation

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Direct Gas-Fired Make-Up Air Models DG and DGX

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

Centeral Station Air Handling Unit

TYPICAL CPA SPECIFICATIONS

Submittal Summary Page

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

MACH N-407 Heat Pump Air-Cooled Chiller

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

1.1 This section applies to air handling units for HVAC Systems.

VertiCool Aurora Engineering Guide

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

LL Series Chillers and Outdoor Mechanical Rooms. Engineering Catalog

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Advance Release September 2009

Air Handling Units. Ranging from 15 to 2,000+ tons and 500 to 400,000+ CFM

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Trane Performance Climate Changer Air Handlers. An air handler for every need.

30GT FLOTRONIC AIR-COOLED CHILLERS

DOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR

SKYPAK II, 3 Ton Series, gives you a

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

PITTSBURG STATE UNIVERSITY. HVAC and BUILDING AUTOMATION SYSTEM STANDARDS

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

The ultimate fresh air solution.

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Optiline Fan Array. The optimum number of fans for every application. The Optimum in Sound Energy Size Redundancy Reliability.

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

30GN FLOTRONIC II AIR-COOLED CHILLERS

Trane Performance Climate Changer Air Handlers. An air handler for every need.

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

VariCool VAV Engineering Guide

SKYPAK II, 3 Ton Series, gives you a

C13-Series Engineering Guide

XeteX, Inc. All Rights Reserved.

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Mammoth Water Source Heat Pumps

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Addendum Downsville Pike Hagerstown MD April 29, 2016

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

Direct Gas-Fired Make-Up Air

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

EHH SERIES DRAW THROUGH FAN COILS CFM

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

AIR HANDLER SPECIFICATION

STEP INSIDE FOR A BREATH OF FRESH AIR. Designed to provide significant outdoor ventilation air to any space.

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Vision and Skyline Semi-custom Air Handlers

AHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Transcription:

RZ PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS Features: Air-cooled condenser, water-cooled condenser, or evaporative-cooled condenser packaged rooftop units from 55-240 tons Water-source and geothermal heat pump options Chilled water or non-compressorized DX air handling units, from 8,900-75,500 cfm R-410A scroll compressors or R-134a oil-free magnetic bearing Turbocor centrifugal compressors Double wall rigid polyurethane foam insulated cabinet construction Optional walk-in compressor and control service vestibule Unit access doors with full length hinges and lockable handles Spring isolated direct drive backward curved plenum supply fans Blow-through and draw-through fan configurations Electric, steam, hot water, indirect fired gas, and direct fired gas heating Power exhaust and power return options Factory installed AAONAIRE sensible and total energy recovery wheels Humidity control features including return air bypass and modulating hot gas reheat Option boxes available for field installed components Application Flexibility Minimizes Installation Time and Reduces Cost Makeup Air Applications Up to 100% Outside Air Dehumidification and Filtration Capabilities Easy to Install and Service Factory Installed or Customer Specific Control Options

RZ Rooftop/Air Handling Units AAON continuously strives to satisfy the dynamic industry requirement for large energy efficient packaged rooftop equipment. The RZ design incorporates the AAON long term commitment and dedication to excel as the premier manufacturer of rooftop equipment. RZ units are available in multiple configurations and include many standard features that make AAON synonymous with quality products for any application. Rooftop Conditioners Superior Features Access doors are provided in areas subject to scheduled maintenance. Walk-in doors are constructed with stainless steel piano hinges, perimeter gaskets, and zinc cast lockable handles that operate from a single point. Aluminum tread plate floor covering in appropriate equipment access areas for improved durability and safety. Selectable number of draw-through or blow-through direct drive backward curved plenum fans allows design flexibility for quieter applications and redundancy for applications where unit up time is critical. Microprocessor controls are compatible with BACnet, Modbus, LonTalk, and Fox protocols for integration with a variety of controls systems. Corrosion resistant polyurethane paint exceeds a 2,500-hour salt spray test. Refrigerant circuits are provided with removable core filter driers and isolation valves for ease of service; no need to cut the refrigerant line as is done with brazed in filter driers. Unit specific color-coded wiring diagrams are provided in point-to-point and ladder form and are laminated and permanently affixed inside the control compartment for ease of service. Factory installed, sensible or enthalpy controlled, AMCA Certified Class 2 low leakage gear driven economizer dampers allows for free cooling. H L Full Featured, Energy Efficient, Packaged Rooftop Units to Meet Today s Requirements! W Premier Options Staged or VFD driven variable speed scroll compressors are available for load matching cooling and increased part load efficiency. Oil-Free magnetic bearing R-134a Turbocor centrifugal compressor option provides load matching cooling capacities with quiet, energy efficient operation. Optional walk-in compressor and control service vestibule provides complete access to all components. Marine service lights for quick and convenient maintenance. Compressor isolation valves are available for improved service efficiency. Double pane viewing windows can be installed in all doors where viewing of operating equipment or interior cabinet is needed. Multiple methods of humidity control including: High Capacity Cooling Coils, Return Air Bypass, and Modulating Hot Gas Reheat Humidity Control which provides efficient dehumidification, even with low sensible heat loads, without the temperature swings common with on/off reheat systems. Multiple high efficiency filtration options, including pleated, cartridge, or bag type, with up to a MERV 14 efficiency rating. Factory installed total and sensible AAONAIRE energy recovery wheels save cooling and heating dollars. Return fans are available for high return static applications. Polymer e-coated coils are available to extend the life of the coils and protect them in corrosive environments. Interior corrosion protection option protects interior components of the unit in corrosive environments. Option boxes are segments of the unit that can be left empty from the factory so that components may be installed in the field without the trouble of installation and service in a crowded cabinet.

Air-Cooled, Water-Cooled, or Evaporative-Cooled Condensers Air-Cooled Condensing Microchannel condenser coils are more efficient due to their enhanced heat transfer. They are also up to 30 percent lighter and use less refrigerant than traditional fin and tube coils. The outward facing coils are intrusion protected with perforated metal screens. All condenser coils are designed for minimum 10 F of refrigerant sub-cooling. VFD can be installed on the condenser fans for head pressure control and greater operating temperature range, as well as to provide reduced sound levels at off design ambient temperatures. All condenser fans are direct drive, axial flow propeller type, and discharge vertically. Evaporative-Cooled Condensing When compared to air-cooled designs these units deliver both outstanding energy efficiency and significant operational cost savings. Energy cost reduction can be 20% to 40% annually dependent on geographic location. Geographic locations that typically require a central chiller and cooling tower are considered primary locations for application of the evaporative-cooled condenser RZ rooftop unit. Factory installed AAON evaporative-cooled condenser, with air-cooled de-superheater and variable frequency drive controlled fans, can be 20-40% more energy efficient than a comparable air-cooled condenser, can use 22-100% less water than a conventional evaporative-cooled condenser, and require 22-100% less chemical usage than a conventional evaporative cooled condenser. Interior of evaporative-cooled condenser is constructed of 304 stainless steel and other non-corrosive materials. De-superheater coils include polymer e-coating for corrosion protection. Water-Cooled Condensing The energy efficient water-cooled units are of particular application value when there exists an accessible water source or when cooling tower water is available. The standard water-cooled RZ units include these features: Shell and tube refrigerant-to-water heat exchangers. Each heat exchanger is provided with are movable and cleanable type basket filter. Heat exchanger piping connections are made within the condensing section of the roof top unit. Air Handling Units The RZ also fits the job when units are required without compressors. The unit will be built without a condensing section and walk-in compressor and control vestibule. All other features and options are readily available. Air handling units may include the following options: Supplied with a DX coil and expansion valves. Supplied with a chilled water coil in 4, 6, or 8 rows. The unit may be specified with any of the heating options to provide a year-round rooftop heating and cooling package. RZ Model Condenser Type Compressor Type Compressors/ Circuits Width Height Length 055 065 075 090 105 120 130 140 Air-Cooled, Water-Cooled Evaporative-Cooled or Air Handling Unit R-410A Scroll 4/2 142 104 Length varies depending on options selected. 090 120 150 180 181 240 Evaporative-Cooled R-134a Centrifugal Turbocor 1/1 2/1 All dimensions are in inches. 142 104 Length varies RZ depending on options selected. Rooftop/Air Handling Units

RZ Features Evaporative-Cooled Condenser Interior of evaporative-cooled condenser is constructed of 304 stainless steel and other non-corrosive materials. A desuperheater is installed above the moisture eliminators, spray nozzles and the copper tube condensers are below. Evaporative-cooled condenser with de-superheater can use 22-100% less water than a conventional cooling tower. AAON furnishes complete three chemical system and all associated controls, injector pumps, and control components to ensure the proper treatment of the water system. Electric Heat Low watt density, nickel chromium element, electric resistance coils. Modules are 40KW individual circuit fused with manual reset high temperature switches. Walk-In Service Vestibule The walk-in service vestibule provides shelter for the maintenance and service personnel while periodic maintenance is performed on the unit. A fluorescent light fixture is furnished in the compartment, controlled by a light switch at the door, and the vestibule can be heated and/or cooled for comfort. AAONAIRE This energy recovery ventilation option can be provided in all model sizes allowing reduced equipment size and operating cost savings while pre-conditioning the outside air being introduced into the conditioned space. Economizer A full line of economizer options are available. All are AMCA certified low leakage with extruded airfoil blades and rubber edge and aluminum end seals. Gas Heat Exchanger Constructed from stainless steel with patented dimpled heat exchanger design to maximize efficiency at all inlet air conditions. Burners have electronic ignition and safety shutdown. Evaporator Coils Each evaporator coil has an expansion valve. Double sloped stainless steel drain pan is provided for positive drainage. Tubing is dressed and structurally supported. Blower Section Single or multiple direct drive, single inlet plenum fans with spring isolation on the entire assembly allows optimization of fan diameter, sound level, and efficiency. Spring Isolators Spring isolators provide sound attenuation for the main blower section. Microchannel Air-Cooled Condenser Coils Microchannel condenser coils are more efficient, lighter, and use less refrigerant than traditional fin and tube condenser coils.

RZ Rooftop/Air Handling Units 130 ton Air-Cooled Condenser Horizontal Configuration RZ Rooftop Unit High efficiency microchannel air-cooled condenser with horizontal supply and return for application flexibility. Modulating gas heating for precise supply air temperature heating control. Tandem VFD controlled variable speed scroll compressors for load matching cooling and increased part load efficiency. VFD controlled condenser fan head pressure control for stable operation and improved part load efficiency. Multiple humidity control options including high capacity evaporator coils and modulating hot gas reheat. Lockable Handles Walk-in doors are constructed with stainless steel piano hinges, perimeter gaskets, and zinc cast lockable handles that operate from a single point. Optional Exhaust and Return Fans The axial flow and plenum power exhaust and return fans are directly driven by the motor. Hinged Access Doors Full length stainless steel piano hinges provide improved reliability over single point hinges.

Patented De-Superheater Design reduces water consumption and chemical treatment Evaporative-Cooled Condenser Rooftop Unit Blow-Through Design Three Tank Water Treatment System AAONAIRE Energy Recovery Wheel Standard Double Sloped Stainless Steel Drain Pan Outside Air Intake Rigid polyurethane foam panel construction provides greater thermal resistance and improved indoor air quality Water-Cooled Condenser Power Exhaust Fan R-410A Scroll Compressor SCR Controlled Electric Heat VFD Controlled Direct Drive Fan Assembly Walk-in Service Vestibule AAONAIRE Integral Energy Recovery Wheel Standard Double Sloped Stainless Steel Drain Pan Water-Cooled Condenser Rooftop Unit Power Return Blower Power Exhaust Fan Outside Air Intake

Heating and Cooling Options The RZ can be configured as either a draw-through or blow-through arrangement with supply or return fans. The supply blower assemblies are direct drive, unhoused, single inlet, single width, fans with spring isolation. The AAON ECat selection software easily allows selection for constant or variable air flow applications. The software determines the most efficient alternatives for the application as a function of fan quantity, fan diameter, fan blade width, and rpm. Inlet and outlet sound ratings are provided for each combination of fans and unit inlet and outlet sound ratings are determined for the overall unit configuration. Multiple fans can provide improved reliability, greater efficiency, lower sound levels, and greater service options. Gas Heat A system unique to AAON, the all stainless steel design construction assures dependable, long term functionality. Through elimination of the need for internal turbulators, this unique design assures trouble free service, capacity, and efficient performance. Electric Heat Electric resistance heating coils are open type with low watt density nickel chromium elements. The heating modules are 40 KW with individual circuit fusing and a manually reset high temperature limit switch. Hot Water and Steam Heat Coils Hot water and steam coils are available in 1 or 2 row configurations with multiple different face areas to meet job requirements. with either spun or die formed end caps. Chilled Water coils are available in 4, 6, or 8 rows deep in two different face areas for each cabinet size. Hot Water or Steam Preheat Coils When jobsite conditions require, coils are available to precondition the outside air. 1 or 2 row hot water or steam coils may be supplied to match the system requirements. Variable Capacity Compressors RZ unit are available with variable capacity compressors which allow the unit to be able to provide a consistent supply air temperature at all operating conditions. VFD driven variable speed R-410A scroll compressors are available for load matching cooling capabilities and increased part load efficiency. Variable capacity R-134a centrifugal compressors provide load matching cooling capabilities, with quiet energy efficient operation. During part load operation, reducing compressor capacity saves system operating costs. Flexibility The wide range of unit sizes, capacities, airflow rates, as well as, the standard design features and the many available options make the RZ the wise selection. A Trend Setting Design In the past when greater airflows were required, the diameter of the single plenum fan was simply increased to meet the requirement. This results in higher tip speeds, which also means higher sound levels. With the AAON RZ, the greater airflow rates can be accomplished with multiple fans of smaller diameter, which inherently will be quieter than a single larger diameter fan. All the fans are also directly driven by the motor, which eliminates the drive belt assembly and associated requirement for maintenance. The entire assembly is then spring mounted to further enhance the vibration isolation and reduce sound transmission. Staged or VFD Driven Variable Speed Scroll Compressor Chilled Water Coils Chilled water coils are constructed of copper tubing mechanically expanded to bond with the aluminum fins. Tube sheets are constructed of 16 GA galvanized steel and extruded holes for the copper tubing. All headers are constructed of heavy wall copper tubing Oil-Free Magnetic Bearing Variable Capacity RZ Centrifugal Turbocor Compressor Rooftop/Air Handling Units

AAON Environmentally Friendly HVAC Product Family Custom & Cataloged Air Handling Units (800-200,000+ cfm) Condensers & Condensing Units (2-230 tons) Chillers (Air-Cooled & Evaporative-Cooled) (4-540 tons) Rooftop Units (2-240 tons) Outdoor Equipment Rooms (Chillers, Boilers & Pumps) Self-Contained Units (3-70 tons) Residential Systems (2-5 tons) Heating and Cooling for... Auditoriums Convenience Stores Health Clubs Healthcare Facilities Homes Lodgings Manufacturing Museums & Libraries Natatoriums Office Buildings Restaurants Retail Stores Schools Supermarkets Geothermal & WSHP Units (2-230 tons) Air-Source Heat Pumps (2-230 tons) Heating and Cooling Coils (Booster, Hydronic, & DX) Defining Quality. Building Comfort. 2425 S. Yukon Ave. Tulsa, OK 74107-2728 www.aaon.com Fluid Coolers (50-450 tons) It is the intent of AAON to provide accurate and current product information. However, in the interest of product improvement, AAON reserves the right to change pricing, specifications, and/or design of its product without notice, obligation, or liability. Copyright AAON, all rights reserved throughout the world. AAON and AAONAIRE are registered trademarks of AAON, Inc., Tulsa, OK. RZ V62360 151008