Radiant Cooling Nonresidential HVAC Stakeholder Meeting #2

Similar documents
Using Embedded Tube Radiant Cooling Systems to Maximize LEED Points

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

EMBEDDED PIPE SYSTEMS. SURFACE HEATING AND COOLING Heat transfer coefficient COOLING CAPACITY. Max. heating-cooling-capacity

Water and Space Heating Nonresidential HVAC Stakeholder Meeting #2

Radiant Heating & Cooling for Commercial Buildings

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Summary Comparison of Simulation Program Features

Modelling Appliance Loads in Multi-Unit Residential Buildings

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

Optimisation of cooling coil performance during operation stage for improved humidity control

August 15, 2013 Page 1 of 19

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active.

HVAC 101. H V A C S y s t e m s

ASHRAE JOURNAL ON REHEAT

HVAC Controls Upgrades: Requirement Details ( )

HVAC DISTRIBUTION and DELIVERY SYSTEMS

7. MECHANICAL SYSTEM DESIGN

Radiant Exchange in Stratified Environments: Considerations and Challenges for Hourly Energy Simulation of UFAD, DV, and Radiant Cooling Systems

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

APPLICATION GUIDE BEAMS

Displacement Ventilation

CHAPTER 4. HVAC DELIVERY SYSTEMS

RADIANT COOLING SYSTEMS OPPORTUNITIES FOR RADIANT COOLING IN NORTH AMERICAN CONSTRUCTION DALE HANSCOMB, REHAU Sales Manager Building Technology

MECHANICAL SERVICES 101. Ian White

Overview: EPIC* radiant systems project. FlexLab Infrared Image of Radiant System

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

HVAC Controls Upgrades: Requirement Details ( )

Daikin VRV Systems Plugin VE2012 User Guide

design brief This design brief provides an introduction into the design and application of DV. It addresses the following issues:

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

- Essay Control Functions and Benefits

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

Process Air Compressors, Boilers, and Water Heaters Stakeholder Meeting 2

Daikin VRV Sizing & Simulation Plug-in User Guide

GARCIA GALUSKA DESOUSA Consulting Engineers

EnergyPlus Testing with Global Energy Balance Test

2009 IECC Commercial Mechanical Requirements

EarthWise System Seminar

Improving Performance with a Building Tune-Up. Janice Peterson, P.E. LEED AP Market Manager, Building Operations BetterBricks

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

White Paper Dehumidification in Humid Climates - A Theoretical Case Study

Copyright 2017 Integrated Environmental Solutions Limited. All rights reserved.

Presented By: John Dolan, P.E.

UniTrane U-Line ductable water terminals Optimum efficiency with a sound reduction bonus

Air Conditioning Clinic

Demand Responsive Lighting Controls

Hello, my name is Sarah Hilden and I am a Marketing Engineer in the C.D.S. group at Trane.

Study Final Report. Priority Cool Refrigerant Study

VARIABLE HEAT RECOVERY IN DOUBLE BUNDLE ELECTRIC CHILLERS. Richard J Liesen 1, Rahul J Chillar 2 1 University of Illinois at Urbana Champaign

New and Emerging HVAC Technologies. Rod Rhoads, GDS Associates Dave McCullaugh, Mitsubishi Electric Trane HVAC US Dave Binz, Cambridge Engineering

CONSTRUCTION AND ENERGY COSTS FOR RADIANT VS. VAV SYSTEMS

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

Dehumidifying with Dedicated Outdoor Air

Chilled Ceilings / Beams Working Principles & Applications

Passive building in Hot and Humid Climates

Technical Investigation, Part Three Elizabeth C. Krauss Mechanical Option September 18, 2013

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Advanced Installation and Configuration Instructions

Chilled Beam and Radiant Cooling Basics. Salt Lake City, UT ASHRAE Chapter December 2013 Nick Searle

Energy Recovery Ventilation

Modular Active. Chilled. Beams

Heating Installation Guide published by

Technical Assignment 3 11/15/04. Executive Summary

Emerging Technologies: VFDs for Condensers. Douglas T. Reindl Director, IRC University of Wisconsin-Madison. University of Wisconsin-Madison

DESCRIPTION OF TECHNOLOGY

NOVEMBER 2012 THE EUROPEAN EXPERIENCE

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

The Ed Roberts Campus Berkeley, CA

General HVAC Recommendations

Benefits Offered by Passive Dehumidification Wheel Speed Control

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

ApacheHVAC User Guide Part F: Loads Analysis and Reporting Tools

Hello, my name is Audra Benzschawel and I m a marketing engineer in the C.D.S. Slide 1 TRACE 700

Displacement Ventilation in Classrooms

SPACE CONDITIONING IN COMMERCIAL BUILDINGS Overview

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

Technical Report Three

4. OVERVIEW OF MECHANICAL SYSTEM

Managing HVAC in High Performance Buildings

The electrical wattage needed by the circulator is:

Hot Water Heating and Distribution Possible CASE Initiatives for 2011 T24 Standards

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK

IDL20e (2 way discharge) IDS60e (4 way discharge) Inffusers. UDI (vertical discharge) Frequently Asked Questions

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Technical Assignment 3

Madeira City Schools Madeira, Ohio. HVAC Assessment. December 2011 (Revised February 2012)

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Comfort and health-indoor air quality

The School District of Philadelphia Administration Headquarters Shell and Core Renovations 440 North Broad Street Philadelphia, PA

COMcheck Software Version Mechanical Compliance Certificate

Transcription:

1 Radiant Cooling Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program Abhijeet Pande Heschong Mahone Group, Inc. Kristin Heinemeier Western Cooling Efficiency Center December 9, 2010 12/09/2010

2 Radiant Cooling Summary of current code requirements Typical practice Summary of code change proposals Data/findings Specifics of code change proposals Remaining data collection and analysis Specific stakeholder requests

Current Code Requirements 3 Prescriptive Requirements No specific requirements exist for radiant systems Performance approach Nonresidential ACM For Primary Systems No system type defined for radiant cooling For Perimeter Systems Independent HVAC systems (typically heating only) which serve perimeter zones They do not connect to the primary system but supply heating/cooling through separate air outlets or heat transfer surfaces. System 12: Convective/radiant. Zone perimeter system may be a convective or radiant system, such as baseboard or radiant ceiling panels.

Typical Practice 4 For compliance calculations, one can model the radiant system using other system types as proxies Built-up single zone with cooling coil but no fan Four Pipe Fan Coil with adjustments to fan energy Induction Cooling with adjustments to fan energy

Potential for Radiant Cooling Radiant Cooling systems being used for highefficiency designs in commercial buildings PNNL identifies radiant cooling as a strategy to meet 50% better than code performance relative to ASHRAE 90.1-2004 Wal-Mart has installed radiant cooling systems in conjunction with dedicated outdoor air systems (DAOS) on several stores Newer products significantly reduce time and labor needed for installing radiant tubes in floors Need for more accurate modeling of radiant cooling system savings when it comes to compliance with Title 24 5

Summary of Code Change Proposals Performance Approach: Develop optional system type for radiant cooling in the nonresidential ACM Floor-based hydronic low-temperature radiant systems Large, open-plan spaces with high ceilings Retail, Warehouse, Atriums Review and revise ACM schedules to add temperature set points appropriate for radiant cooling Develop intelligent defaults for the ACM model With user over-rides where appropriate 6

Data / Findings 7 Interviews with Manufacturers/Designers System Types Costs (materials and installation) Energy Savings (calculations and field data) Design Practice regarding sizing and controls Review Simulation/Analysis Tools Engineering Analysis Tools EnergyPlus ASHRAE Tool-kit (RP 1383) Simulation Inputs Defaults and allowable range of inputs

Summary of Interviews 8 11 Individuals Interviewed: 4 Design Engineers, 5 Manufacturers, 2 Owners Reps System Types Available for Floor-based Installations: PEX pipe systems PEX pipe mats Radiant panels Building Types Suitable for Radiant Cooling: Institutional Airports, museums, universities, churches Commercial Big-Box retail Office buildings with lobby or foyer Any building with high solar gains Projects going for LEED

Summary of Interviews 9 Design Criteria: Pipe size ½ - ¾ ( 5/8 is most common) Pipe Spacing - 6-9 (up to 12 for heating) Controls for supply water temperature and flow rate Mostly variable temperature with constant flow Some use variable temperature and variable flow for optimized control Some use constant temperature, constant flow as well Thermostatic control of system operation Zone air temperature most commonly used Sometimes based on radiant temperature Time of use Not much use of pre-cooling or night-cooling to charge the mass before occupied hours or outside of peak hours Optimum start or adaptive control used by some

Summary of Interviews 10 Design Criteria: Condensation control Radiant systems control sensible loads only Dedicated outdoor air system to handle latent loads Limit slab surface temperature to dewpoint temperature plus 1-3 degrees Occupant Comfort Slab surface temperature maintained at or above 66 F to prevent floors from being too cold

Summary of Interviews 11 Analysis Procedures Rules of Thumb Manufacturers will tailor systems to meet loads Load calculations provided by mechanical engineers Manufacturers use Finite Element Analysis or other proprietary tools System Design Tools Energy Plus for system modeling Trane Trace for sizing loads Custom software used by mechanical engineers/designers

Summary of Interviews 12 System Costs Material Costs $1-$2/sqft for pipes, fittings, valves Installed Costs Pipes, fittings, valves RS Means: $4-$5.25/sqft w/o controls (conservative estimate) $2-$30/sqft additional for controls Entire system including dedicated outdoor air systems (DAOS) & Plant $9.30/sf 7.6 year payback Source: PNNL analysis for 50% savings beyond ASHRAE 90.1-2004

Simulation Tools Review 13 Compliance with DOE-2.1E Several options to model None explicit in modeling radiant heat exchange Example project Building with floor-based hydronic radiant system Using compliance model for a recently constructed building Option 1 Modeled as Four Pipe Fan Coil Compliance margin at 12% above code Cooling uses 14% less energy than standard design Option 2 Modeled as Induction Unit Compliance margin at 16% above code Cooling uses 28% less energy than standard design Engineering calculations predict energy savings beyond code at ~30% for all end-uses

Simulation Tools Review 14 Engineering Analysis Rules of thumb for heat exchange rate from radiant slab to space 15-16 btu/sf in best conditions 8-12 btu/sf heat transfer is typical 4-5 btu/sf worst case scenario Typical design process Spreadsheet-based tools to size system output Pipe size and spacing (best practices) used to develop water temperature and flow-rate profiles Parametric analysis of pipe sizing and spacing to get desired temperature and flow-rates If system is under-sized, then supplemental cooling is needed with air-side system

Simulation Tools Review 15 EnergyPlus Full-featured energy analysis software has built-in modules for several radiant technologies High-temperature radiant systems Hydronic or eletric Low-temperature radiant systems Hydronic or electric Low-temperature hydronic radiant systems Define construction where piping is embedded Define pipe diameter, spacing and location Define schedules and controls Variable OR constant flow Variable OR constant temperature

Simulation Tools Review 16 ASHRAE Tool-kit ASHRAE research project RP1383 is developing a Radiant System Module for the Simulation and Analysis of spaces and systems Radiant cooling algorithms based on EnergyPlus Extends capabilities of the ASHRAE toolkits Allow comparison of thermal environments for radiant systems and some limited number of forced air systems Model low temperature hydronic systems (floor, ceiling and wall) as well as electric powered systems Model thermal comfort assessment criteria Limited amount of input for single room (emphasis on a single room environment under load calculation conditions) Not yet available for use

Energy Simulation with EnergyPlus 17 Retail store sales floor with a radiant cooling slab Actual Operation Variable volume & variable temperature Air-cooled chiller and fluid cooler for free cooling and refrigeration racks Air-side system for heating / ventilation uses IDEC and heat recovery (not modeled for simplicity) Advanced controls sequencing Initial runs Parametric analysis Supply water temperature to slab Occupant density in space Control temperature (air temp, MRT, Operative Temp, Outside DB, Outside WB)

Effect of CHW Supply Temperature 18

Effect of CHW Supply Temperature 19

Effect of Occupant Density 20

Specifics of Code Change Proposals 21 Add Optional System Type Description in Nonresidential Alternative Compliance Manual Section 3.3.5 Move existing section 3.3.5 to 3.3.6 Modeling rules for low-temperature hydronic radiant systems Constant Flow Systems Variable Flow Systems

Specifics of Code Change Proposals 22 Low-Temperature Radiant with Variable Flow Input Keyword Acceptable Range by Software Acceptable Range for Compliance Calculations Surface Name or Radiant Surface Group Name Walls, Floors, Ceilings Floors Hydronic Tubing Length X > 0, no max, no default, can autosize No-autosizing (required input). Max TBD. e.g. 0-400 ft/loop of piping between headers. Hydronic Tubing Inside Diameter X > 0, no max, default = ½ 1/2-3/4 Temperature Control Type Operative Temperature, Mean Air Temp, Mean Radiant Temp, ODB, OWB Maximum Cold Water Flow Rate No default, no max TBD Mean Air Temp, Operative Temp (?)

Specifics of Code Change Proposals 23 Low-Temperature Radiant with Variable Flow Input Keyword Acceptable Range by Software Acceptable Range for Compliance Cooling Control Throttling Range Deg F - No min, no max User inputs Cooling Control Temperature No default User inputs Condensation Control Type Off, SimpleOff, VariableOff SimpleOff, VariableOff Condensation Control Dewpoint Offset No min or max 2 deg F above dewpoint Also establish limits on hours load un-met by radiant system Establish appropriate mean air temperature setpoints when used to control radiant systems

Specifics of Code Change Proposals 24 Low-Temperature Radiant with Constant Flow Input Keyword Acceptable Range by Software Acceptable Range for Compliance Calculations Surface Name or Radiant Surface Group Name Walls, Floors, Ceilings Floors Hydronic Tubing Length X > 0, no max, no default, can autosize No-autosizing (required input). Max TBD. e.g. 0-400 ft/loop of piping between headers. Hydronic Tubing Inside Diameter X > 0, no max, default = ½ 1/2-3/4 Temperature Control Type Operative Temperature, Mean Air Temp, Mean Radiant Temp, ODB, OWB Rated Flow Rate No default no max TBD Rated Pump Power Consumption No min, no max No max Mean Air Temp, Operative Temp (?) Motor Efficiency 0-100% Premium Motors

Specifics of Code Change Proposals 25 Low-Temperature Radiant with Constant Flow Input Keyword Acceptable Range by Software Acceptable Range for Compliance Rated Pump Head Default = 60 User input. Max TBD Fraction of Motor Inefficiencies to 0-1.0. Default =0 User Input Fluid Stream Cooling High Water Temperature Max supply water temp. No limits. User Input Cooling Low Water Temperature Min supply water temp. No limits Min 55 deg F Condensation Control Type Off, SimpleOff SimpleOff Condensation Control Dewpoint Offset No min or max 2 deg F above dewpoint Also establish limits on hours load un-met by radiant system Establish appropriate mean air temperature setpoints when used to control radiant systems

Simulation Guidelines 26 What about users of DOE-2.1E? Specify modeling procedures using Four Pipe Fan Coil model Fan power set to zero for radiant modeling CHW supply temperatures appropriate for radiant systems IES-VE and other engineering tools provide procedures for effective slab conductivity Modify slab conductivity based on calculating temperature of embedded pipes and heat trasnfer to/from the slab

Specifics of Code Change Proposals 27 Adjusted slab conductivity example Input the green values. Read the red value. Pipe radius a 0.00794 m Pipe spacing s 0.1524 m Slab thickness above pipes d 0.1524 m Slab conductivity lambda 1.4000 W/mK Floor surface resistance rsurf 0.1200 m2k/w Effective slab thickness d' 0.3204 m s/a 19.2000 d'/s 2.1024 z 13.2095 sinh(z) 272769.9744 dt/v0 14.3266 Effectiveness* eta 0.9220 Adjusted slab conductivity lambda' 1.1887 W/mK Conductivity adj. factor lambda'/lambda 0.8491 *Effectiveness is ratio of the actual heat output to the heat output that would result if the pipe zone temperature equalled the water temperature.

Remaining Data Collection and Analysis 28 Complete parametric analysis of EnergyPlus inputs Complete comparison of monitored data with simulation results Continue market surveys with designers, manufacturers Develop acceptable ranges for compliance inputs and modeling guidelines

Specific Stakeholder Requests 29 Market and design practices To develop acceptable ranges for simulation inputs and modeling guidelines System energy savings Case studies

30 Radiant Cooling QUESTIONS & COMMENTS