Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Similar documents
Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Hygro/hygrothermal transducers (hygrometric)

It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes.

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

VALTRONICS IAQ Monitor

02/11/2015

Duct Air Quality Sensors

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

for relative humidity and temperature with calibration certificates

02/11/2015

LC1350 Level Controller

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Accuracy by Design Products for the HVAC Professional

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Hygro/hygrothermal transducers (hygrometric)

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

Key Features. General Description

Hygrostats (hygrometric)

Model D12-IR. Digital Gas Transmitter...

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

DP 300 mobile dew point instrument

HYGRASREG RELIABLE PROTECTION AGAINST HUMIDITY FÜHLBARE PRÄZISION PRODUCT RANGE > Mechanical > Electronic > Guards

for relative humidity and temperature

Temperature Controllers

BC3250. Blowdown Controller

QPM21 Series Duct CO 2 and Air Quality Sensors

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Air Quality Sensors. Particle Matter, CO 2, Humidity, Temperature and Dust Products. OEM Sensor Components for Air Quality and Environmental Control

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Using the Model 1500 Portable Chilled Mirror Hygrometer

Environmental simulation chamber for complex alternating climate profiles

Sensors and switches. Temperature, Pressure, Humidity, Air flow, CO 2., CO and NO 2

Infrared Carbon Dioxide Sensor Module CM1107-Dual Beam

QFM21... Duct sensors. Symaro. for relative humidity and temperature

DMFPM-2R MULTIFUNCTIONAL

Constant climate chambers

A and B Series Sensors for humidity and temperature for digital transfer RS485 / MODBUS-RTU or RS232


Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

gas monitoring system

IR25 Dual Gas Series Datasheet

Oxygen Sensing Solutions

General Specifications

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

A and B Series Sensors for humidity and temperature for digital transfer RS485 / MODBUS-RTU or RS232

THM80X Series Operation Manual Industry Degree Temp. & Humidity Transmitter V 0.1

SIMRAD GD10PE IR GAS DETECTOR

KANE-ALERT-CO 2 Monitor with Temperature

Room air quality sensors

Constant climate chambers

COA-2010-F Electronic CO 2

Constant climate chamber with humidity

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

Constant climate chambers

Pressure measuring instruments

portable gas analyser

Datasheet: K-22 LO Sensor

Constant climate chamber with ICH-compliant illumination

Duct Temperature Sensors

Technical data Humidity Temperatur General data Electrical data Two designs duct version (LK) wall mounting

Lamp Supply (Recommended)

KMF Environmental test chamber for constant climate

RS485 MODBUS Module 8AI

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

CO 2 Incubators INCO 2

Relative Humidity Transmitters

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

Constant climate chambers

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

CTT8 TEMPERATURE MONITOR DEVICE

HYGROPHIL H process hygrometer

RS Pro Infrared Temperature Sensor

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

ECOLOG-NET LA8 and WA8 (wireless), 8 x 4..20mA signals

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

D Series Sensors for Humidity and Temperature Measurement With calibrated dmodul

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

P R O D U C T D ATA S H E E T

portable gas analyser

GMH 285 / GMH 285-BNC

MO n : 12JMC rév A

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Chlorine gas leak detector

Transcription:

Data Sheet 907021 Page 1/9 Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring For measuring relative air humidity, temperature, and fresh air quality Available in indoor, wall-mounted, duct, and rod versions For applications in building management and in areas of climate and ventilation monitoring Option of LCD display Available with current, voltage, or Modbus output, and passive resistance output for temperature These capacitive humidity measuring probes are designed for the most common applications in heating, air-conditioning, and ventilation technology and stand out in particular due to their high measuring accuracy, excellent long-term stability, and good chemical resistance. The modern case concepts make for low costs and offer the greatest possible protection from pollutants and condensation, which in turn allows the best and most fault-free continuous operation possible. The CO 2 measuring probes use proven infrared technology for measuring the carbon dioxide concentration. The NDIR procedure used in this has a patented auto calibration function, eliminates aging effects, and so allows accurate measurement of the CO 2 values with long-term stability. Different combination options between the measurands carbon dioxide (CO 2 ), humidity (RH), and temperature (T) in visually appealing and easy-to-install cases once again set new standards in heating, air-conditioning, and ventilation technology, as well as in many other areas in which relevant measurement technology is used. This series enables a broad spectrum of uses in indoor, wall-mounted, duct, and rod versions. Standardized current or voltage signals are available as outputs, and for some devices passive resistance outputs as well as a digital output are also available as an option. Measuring probes in indoor and wall-mounted versions can be equipped with a digital display. Furthermore a battery-operated tabletop and wall-mounted indicator is the ideal and cost-effective solution if just a simple display is needed. Depending on the particular version and design type, applications exist across practically the entire building management sector, and in all areas of air-conditioning and ventilation technology. Areas of application: humidification and de-humidification plants, accommodation and office areas, public buildings, agriculture and stables, incubators, drying chambers, greenhouses, storage rooms and cold stores, production halls, indoor swimming pools, etc.

Data Sheet 907021 Page 2/9 Technical data Humidity (RH) Humidity sensor Capacitive, can take condensation (with sensor coating) Humidity measuring range 0 to 100 % RH Humidity working range 10 to 90 % RH: Tabletop and wall-mounted indicator, indoor version 10 to 9 % RH: Wall-mounted and duct version (HVAC) 0 to 100 % RH: Wall-mounted and duct version, rod version Humidity accuracy at 20 C ±2 % RH: Indoor version and display unit in the humidity range of 40 to 60 % RH, wall-mounted and duct version in the humidity range of 0 to 90 % RH, rod version with Modbus output, (in the remaining range ±3 % RH) ±2. % RH: Wall-mounted and duct version (HVAC), rod version (for DC 24 V, 20 C and 0.2 m/s) ±3 % RH: Indoor version with CO 2 in the humidity range of 30 to 70 % RH, (in the remaining range ± % RH) Temperature dependency ±0.03 % RH/ C (typical) Sensor coating Sensor coating for the humidity sensor is an additional protective coating, which offers better protection from contaminants for the humidity sensor and in many cases allows for longer service life, especially with particularly contaminated or aggressive atmospheres. With the exception of the indoor version, all devices are equipped with this feature for increased protection as standard. Temperature (T) Temperature sensor Platinum-chip temperature sensor Pt1000 according to DIN EN 6071, (passive also Pt100) Temperature measuring range 0 to 0 C: Indoor version; wall-mounted and duct version (HVAC) and (CO 2 ) - to + C: Tabletop and wall-mounted indicator -40 to +80 C: Wall-mounted and duct version (observe admissible ambient temperature) -40 to +60 C: Rod version (-40 to +80 C with Modbus output) Temperature accuracy at 20 C ±0.2 C: Wall-mounted and duct version, rod version with Modbus output (±0.6 C in the end range at 20 C) ±0.3 C: Indoor version voltage output, duct version (CO 2 ) ±0.4 C: Indoor version current output (±0.7 C with CO 2 ) ±0.3 C: Wall-mounted and duct version (HVAC); rod version, tabletop and wall-mounted indicator Carbon dioxide (CO 2 ) Measuring principle Sensor Measuring range Accuracy at 2 C and 3 mbar Temperature dependency Long-term stability Sampling rate Response time Warm-up time NDIR (non-dispersive infrared technology) 2-beam infrared cells 0 to 2000 ppm, 0 to 000 ppm 0 to 10000 ppm (only wall-mounted and duct version) ±(0 ppm +2 % of the measured value) for 0 to 2000 ppm ±(0 ppm +3 % of the measured value) for 0 to 000 ppm ±(100 ppm + % of the measured value) for 0 to 10000 ppm 2 ppm CO 2 / C (typical) 20 ppm/a (typical) Approx. 1 s < 19 s (300 s for wall-mounted version) <min

Data Sheet 907021 Page 3/9 Electrical data Voltage supply Current consumption Load resistance Output signals Case 2 DC 1. V alkaline batteries: DC 1 to 3 V, AC 24 V ±20 %: DC 20 to 28 V: DC 20 to 3 V: DC 4. to 30 V: DC 9 to 28 V: DC 4 to 18 V: Tabletop and wall-mounted indicator For output of 0 to 10 V / RS48 or CO 2 measuring probe For output of 4 to 20 ma For output of 4 to 20 ma (HVAC) Only rod version with voltage output Only rod version with current output Only rod version with Modbus output to 1 ma for DC voltage supply (wall-mounted and duct version) 13 to 2 ma for AC voltage supply (wall-mounted and duct version) 1. ma for rod version (typical 0.4 ma for Modbus output, sampling rate 1 s) 10 ma plus output current, max. 0. A for 0.3 s for CO 2 measuring probe R L < 00 ohm with current output Electromagnetic compatibility EN 61326-1 and EN 61326-2-3 Connection Screw terminals max. 1. mm 2 Connection diagram 4 to 20 ma and 0 to 1 V, 0 to 10 V, passive also Pt100 and Pt1000 RS48 digital output (basic types see order details) See operating manual Case Polycarbonate Protection type IP20: indoor version, tabletop and wall-mounted indicator IP6: wall-mounted, duct and rod version Cable entry M16 1. wall-mounted and duct version Ambient temperature -20 to +60 C: Indoor version, wall-mounted and duct version (CO 2 ) - to + C: Indoor version with LCD display, tabletop and wall-mounted indicator -1 to +60 C: Wall-mounted and duct version (HVAC) -40 to +60 C: Wall-mounted and duct version (-20 to +0 C with LCD display) -40 to +60 C: Rod version Storage temperature -20 to +60 C: Indoor version -2 to +60 C Wall-mounted and duct version (HVAC) -40 to +60 C Wall-mounted, duct and rod version Weight Approx. 100 g: Indoor version and tabletop and wall-mounted indicator Approx. 10 g: Wall-mounted version Approx. 20 g: Duct version Approx. 10 g: Rod version (1. m connecting cable, standard) Approx. 180 g: Rod version (3 m connecting cable)

Data Sheet 907021 Page 4/9 Accessories Filters Humidity sensor checks Plastic-grid membrane filter "HA001" (standard): For low to normal contamination levels in the area of heating, ventilation, and air-conditioning. Pore size 1 µm, t 10/90 approx. 1 s Stainless steel sinter filter "HA003": Most positive effects for high mechanical and thermic stresses. Unsuitable for high-humidity range. Pore size 10 µm, t 10/90 approx. 30 s Plastic-grid power-line filter "HA006": With high humidity, danger of condensation, or rapidly changing humidity cycles. For average contamination level. Pore size 100 µm, t 10/90 approx. 7 s PTFE filter "HA00": For high chemical resistance. Pore size 0 µm, t 10/90 approx. 14 s Humidity sensor checks can be used to test the accuracy of humidity measuring probes. The test procedure is described in DIN 0008, IEC publication 260, ISO /R 483-1966. The basic principle consists of an appropriate climate being produced above an aqueous, saturated salt solution. Humidity sensor checks with values of 33 % RH, 3 % RH, and 76 % RH are available from stock.

Data Sheet 907021 Page /9 Dimensions 34 106 100 (3000) 34 41 8 Ø 13 Basic type 907021/11 and 907021/80 indoor version and basic type 907021/12 tabletop and wall-mounted indicator Ø 12 Basic type 907021/60 hygrothermal transducer, rod version with 1. m (3 m) connecting cable Ø 12 Basic type 907021/71 hygrothermal transducer, rod version with M12 1-plug connector Ø > 13 20 Sealing ring 60 ±0.3 Ø 12 M16 1. Ø > 16 6 19 M16 1. Basic type 907021/160 hygrothermal transducer, wall-mounted version (HVAC) and basic type 907021/161 hygrothermal transducer, duct version (HVAC)

Data Sheet 907021 Page 6/9 Ø > 13 20 Sealing ring 60 ±0.3 Ø 12 M16 1. Ø > 16 6 19 M16 1. Basic type 907021/210 hygrothermal transducer, wall-mounted version and basic type 907021/211 hygrothermal transducer, duct version 19 M16 1. Basic type 907021/820 CO 2 measuring probe, wall-mounted version Ø > 13 200 Sealing ring 60 ±0.3 19 Ø > 16 6 M16 1. Basic type 907021/80 CO 2 measuring probe, duct version

Data Sheet 907021 Page 7/9 Order details (1) Basic type 907021/11 Hygro transducer, hygrothermal transducer, indoor version 907021/12 Hygro thermometer, tabletop and wall-mounted indicator 907021/160 Hygrothermal transducer, wall-mounted version (HVAC) 907021/161 Hygrothermal transducer, duct version (HVAC) 907021/210 Hygrothermal transducer, wall-mounted version 907021/211 Hygrothermal transducer, duct version 907021/60 Hygrothermal transducer, rod version with 1. m connecting cable 907021/71 Hygrothermal transducer, rod version with M12 1-plug connector (2) Version x x x x x x x 2 Humidity and temperature x x x 3 Humidity and temperature (T passive) x x x x x 9 Humidity and temperature (digital) (3) Measuring ranges / scaling (observe admissible ambient temperature) x x 10 0to100%RH; -20to+80 C x x x 14 0to100%RH; -40to+60 C x x 22 0to100%RH;-30to+70 C x 33 10to90%RH;-to+ C x x x x x 34 0to100%RH; 0to0 C x x x x x 90 Digital output (4) Output x 000 None x x x x x 00 4to20mA / 4to20mA x x x 006 4 to 20 ma / temperature (T passive) Pt100 class A x x x 007 4 to 20 ma / temperature (T passive) Pt1000 class A x 01 0to1V / 0to1V x x x x x x 06 0to10V / 0to10V x x x 066 0 to 10 V / temperature (T passive) Pt100 class A x x x 067 0 to 10 V / temperature (T passive) Pt1000 class A x x x x x 30 RS48 Modbus interface (configuration in plain text, see table "Interface parameters digital output") () Extra codes x x x x x x x x 000 None x x x 793 Integrated LCD display (indoor version for humidity and temperature, alternating display) x x x 794 Integrated LCD display (as extra code 793, but with temperature display in F) (non-metric) x 847 Longer connecting cable length 3 m (1) (2) (3) (4) () Order code - - - / Order example 907021/11-2 - 34-06 / 000 Interface parameters digital output (output "30") Protocol Baud rate Parity Stop bit(s) Unit Modbus (1) 9600 (A) odd (O) 1 stop bit (1) metric (M) 19200 (B) even (E) 2 stop bits (2) non-metric (N) 38400 (C) no parity (N) Note: Please also observe the humidity working range and the admissable ambient temperatures (see "Technical data") A third output is only available for multi-channel devices and not always possible for all device combinations.

Data Sheet 907021 Page 8/9 Order details (1) Basic type 907021/80 CO 2 measuring probe indoor version 907021/820 CO 2 measuring probe wall-mounted version 907021/80 CO 2 measuring probe duct version (2) Version x x 4 CO 2 (1-channel output) x x CO 2 and temperature (only for duct version 0 to 10 V) x x 6 CO 2 and temperature (T passive) x 7 CO 2, temperature, and humidity (only for 0 to 10 V) (3) Measuring ranges / scaling (observe admissible ambient temperature) x x x 040 0 to 2000 ppm; 0 to 0 C; 0 to 100 % RH x x x 041 0 to 000 ppm; 0 to 0 C; 0 to 100 % RH x x 042 0 to 10000 ppm; 0 to 0 C; 0 to 100 % RH (4) Output x x x 00 4to20mA / 4to20mA x 006 4 to 20 ma / temperature (T passive) Pt100 class A x x 007 4 to 20 ma / temperature (T passive) Pt1000 class A x x x 06 0to10V / 0to10V x 066 0 to 10 V / temperature (T passive) Pt100 class A x x 067 0 to 10 V / temperature (T passive) Pt1000 class A () Extra codes x x x 000 None x 793 Integrated LCD display (indoor version for humidity and temperature, alternating display) x 794 Integrated LCD display (as extra code 793, but with temperature display in F) (non-metric) (1) (2) (3) (4) () Order code - - - / Order example 907021/80 - - 040-00 / 000 Note: A second output is only available for multi-channel devices and is not always possible with all device combinations.

Data Sheet 907021 Page 9/9 Stock versions Order code Part no. 907021/11-2-34-00/000 00436298 907021/11-2-34-00/793 0044142 907021/12-2-33-000/000 00440647 907021/160-2-34-00/000 00630604 907021/161-2-34-00/000 00630609 907021/210-2-10-00/000 00630616 907021/210-2-14-00/000 00630624 907021/210-2-14-00/793 00630630 907021/211-2-10-00/000 006306 907021/211-2-14-00/000 00630790 907021/60-2-14-01/000 00630791 907021/80--40-00/000 0078092 907021/80--40-00/793 0078093 907021/80-7-40-00/793 0078094 907021/820-4-41-00/000 00630792 907021/80-4-40-00/000 00630796 907021/80-6-40-007/000 00630797 Accessories Description Part no. Plastic-grid membrane filter "HA001" 00388181 Stainless steel sinter filter "HA003" 00388183 Plastic-grid power-line filter "HA006" 00389114 PTFE filter "HA00" 00037 Humidity sensor check 33 % RH 0033278 Humidity sensor check 3 % RH 0033279 Humidity sensor check 76 % RH 00332760 Mating coupling M12 1 for the case "HA01070" 0064218 Mating coupling M12 1 can be modified, IP67 "HA010707" 00642189 PUR extension cable M12 1 (shielded), length 2 m 000377 PUR extension cable M12 1 (shielded), length m 000378 PUR extension cable M12 1 (shielded), length 10 m 000379