Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Similar documents
Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Hygro/hygrothermal transducers (hygrometric)

Hygro/hygrothermal transducers (hygrometric)

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

Hygrostats (hygrometric)

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

DP 300 mobile dew point instrument

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Relative Humidity Transmitters

It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes.

for relative humidity and temperature

Sensors and switches. Temperature, Pressure, Humidity, Air flow, CO 2., CO and NO 2

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Product data sheet AIRWIN BO-FK-120J Humidity sensors

for relative humidity and temperature with calibration certificates

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

Duct Humidity/Temp Sensor

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Outside Air Humidity & Temperature Sensor

M7100 Pressure Transducer

SITRANS F M MAG 3100 P:

HYGROMER MP 100 A Meteorology probe

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Condensation drying for industry and trade

Room Humidity/Temp Sensor

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

HYGRASREG RELIABLE PROTECTION AGAINST HUMIDITY FÜHLBARE PRÄZISION PRODUCT RANGE > Mechanical > Electronic > Guards

HUM-M2 Humidity Sensor Module Description

Potential Applications

Rules for Intruder Alarm Systems

Selecting the right humidity sensor for your application

Measurement and Control Technology

Digital Salt / TDS Meter. 390a. The Value Leader TM

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

HYGROMER - MP 400 A Meteorology probe

Product data sheet AIRWIN BO-120 Hygrostats

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

GMH 285 / GMH 285-BNC

Model 5190-F Temperature/Humidity Probe

MP 601A Humidity Probe INSTRUCTION MANUAL

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Using the Model 1500 Portable Chilled Mirror Hygrometer

Gas cylinder scale Model GCS-1

WIO200 Water In Oil measuring instrument

Flame detector. The QRA4.U is for use with the following types of burner control:

Introduction to humidistats

M5200 Industrial Pressure Transducer

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

THERMASREG TR 040 THERMASREG TR 060

Accessories, interfaces, sensors and complete solutions.

Duct Temperature Sensors

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

U5300 Industrial Pressure Transducer

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

TSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits

Inductive slot sensor

Are Thermistors the Right Choice for Your Temperature Measurement Application?

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

Model 144H. Product Data Sheet , Rev DB February Content

Room Temperature Sensors

Flame detector. Building Technologies Division Infrastructure & Cities Sector

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

FAST RESPONSE TEMPERATURE SENSORS 42.11a

Duct Temperature Sensors

LOW PRESSURE Intrinsically Safe Transducer AST44LP

Snifter ATEX22 VERSION. User Manual. Distributor

INTERNAL STIRRING CF LIQUIDS

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

Light is simple Compact Monsun The LED damp-proof luminaire range for challenging lighting tasks.

MELA Sensortechnik GmbH

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Flame detector. The QRA4.U is for use with the following types of burner control:

Model 5190-E Temperature/Humidity Probe

Sitron s CF Line of Flow Switch Monitors

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

UDC100 Universal Digital Controller Specifications

Model 144H. Product Data Sheet , Rev DB February Content

Reproducible Climate...

Complete packages with Software and Controller

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

U5600. Wireless Pressure Transducer SPECIFICATIONS

Sintrol Snifter A1+ Manual. Version 1.2.2

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

Transcription:

Data Sheet 90.7021 Page 1/6 Hygro and hygrothermo transducers (capacitive) for HVAC monitoring for measuring relative humidity and temperature for HVAC applications as indoor, wall and duct versions special miniature rod version for OEM applications with current or voltage outputs These humidity transducers have been especially developed for HVAC applications and are characterized by their outstanding long-term stability, high measuring accuracy, excellent high-humidity response and good chemical resistance. Attractively designed cases as wall or duct models for indoor use, and as miniature rod models, can optimally handle almost any air-conditioning task. Transducers for humidity, as well as combined instruments for humidity and temperature with current or voltage outputs are available. Applications include the complete air conditioning and ventilation sector in domestic and office buildings, as well as in storage areas and greenhouses. For the especially high requirements of indoor swimming pools and stables, transducers in version A have proved particularly successful, in addition to achieving excellent measurement results in metereology. Furthermore, the special rod model is available for integrating humidity measurement into existing systems where space is tight, thus making it particularly suitable for OEM applications. Technical data Humidity sensor Humidity range Humidity working ranges Humidity accuracy at 20 C capacitive, condensation permitted 0 100% rh 10 90% rh: indoor version 20 90% rh: wall and duct version (version B); rod version 0 100% rh: wall and duct version (version A) ± 3% rh: indoor version with voltage output ± 3% rh: indoor version with current output; wall and duct version (version B) within humidity range 40 60% rh ± 5% rh: indoor version with current output; wall and duct version (version B) in remaining damp area ± 3% rh: rod version at 54% rh ± 5% rh: rod version in remaining damp area ± 2% rh: wall and duct version (version A) in damp area 0 90% rh ± 3% rh: wall and duct version (version A) in remaining damp area Temperature error at 45% rh typically -0.05% rh / C Temperature sensor platinum-chip temperature sensor Pt1000 to EN 60 751, tolerance class A Temperature ranges 0 to +50 C: indoor version; wall and duct version (version B) -20 to +80 C: wall and duct version (version A) -40 to +60 C: rod version Temperature accuracy at 20 C ± 0.3 C: indoor version: voltage output; wall and duct version (version A) ± 0.5 C: indoor version: current output; wall and duct version (version B); rod version Output signals 4 20mA, 0 1V, 0 5V, 0 10V (instrument version according to order code)

Data Sheet 90.7021 Page 2/6 Supply 15 35V DC; 24V AC ± 20%: instruments with voltage output 20 28V DC: instruments with current output 4.5 27V DC: only for rod version Electromagnetic compatibility to EN 50 081-1 and EN 55 104 Case ABS plastic for indoor version PC plastic with wall, duct and rod version Protection IP20: indoor version IP40: wall and duct version (version B) IP65: wall and duct version (version A); rod version Load resistance R L 500 Ohm max. for current output Current 20mA max., 5mA for rod version Ambient temperature - 5 to +50 C: indoor, wall and duct version (version B) -20 to +50 C (sensor head +80 C): wall and duct version (version A) -20 to +60 C: rod version Storage temperature -30 to +60 C Weight approx. 100g for indoor version approx. 150g for wall version approx. 250g for duct version approx. 50g for rod version Accessories Dust filter Membrane filter (standard) for low-level contamination in the HVAC area (indoor application) Sintered bronze filter for mechanical loads and very dusty atmospheres Sintered stainless steel filter extremely effective with mechanical and thermal loads, as well as with corrosive media Metal mesh filter for high humidity, risk of condensation or rapidly changing humidity cycles Humidity sensors Temperature sensor Humidity sensor checks Type: HC 101 for rod version nominal capacity 200 ± 20pF operating temperature -40 to +120 C Type: HC 200 for wall and duct versions (version B) nominal capacity 200 ± 20pF operating temperature -40 to +110 C Type: HC 1000 for indoor, wall and duct versions (version A) nominal capacity 500 ± 50pF operating temperature -40 to +120 C platinum-chip temperature sensor made in thin-film technology to EN 60 751, tolerance class A nominal value 1000 Ohm at 0 C dimensions in mm (W x L x H) 2.0 x 5.0 x 1.3 temperature range -50 to +400 C Humidity sensor checks can be carried out, to check the accuracy of humidity transducers. The checking procedure is described in detail in DIN 50 008, IEC Publication 260, ISO/R 483-1966. The underlying principle is that a certain climate forms in the air above an aqueous, saturated salt solution. Sensor check sets with values of 33%, 55% and 76% rh are available from stock.

Data Sheet 90.7021 Page 3/6 Dimensions Indoor version Type 907021/10 Wall version Type 907021/20 Type 907021/21 Duct version Type 907021/30 Type 907021/31 Rod version Type 907021/40 Measurements in mm.

Data Sheet 90.7021 Page 4/6 Connection diagram Indoor version Type 907021/10 Wall/duct version Type 907021/20, Type 907021/21, Type 907021/30, Type 907021/31 Rod version Type 907021/40

Data Sheet 90.7021 Page 5/6 Order details: Hygro and hygrothermo transducers (capacitive) for HVAC monitoring (1) Basic version 907021/10 Hygro/hygrothermo transducer, indoor version 907021/20 Hygro/hygrothermo transducer, wall version (version A) 907021/21 Hygro/hygrothermo transducer, wall version (version B) 907021/30 Hygro/hygrothermo transducer, duct version (version A) 907021/31 Hygro/hygrothermo transducer, duct version (version B) 907021/40 Hygro/hygrothermo transducer, rod version (2) Hygro/hygrothermo transducer X X X X X X 1 Humidity X X X X X X 2 Humidity and temperature 1 (3) Ranges X 32 0 100% rh; 0 to +50 C X X 34 0 100% rh; 0 to +50 C X X 10 0 100% rh; -20 to +80 C X 14 0 100% rh; -40 to +60 C (4) Output signals X X X X X 005 4 20mA X X X 051 0 1V X X 057 0 5V X X X X X 065 0 10V (1) (2) (3) (4) Order code - - - Order example 907021/10-1 - 32-005 1. Please take note of the humidity working ranges under Technical Data! Stock versions: (1) (2) (3) (4) Sales No. - - - 907021/10-1 - 32-005 90/00388168 907021/10-2 - 32-005 90/00388169 907021/20-1 - 10-005 90/00388170 907021/20-2 - 10-005 90/00388171 907021/21-1 - 34-005 90/00388172 907021/21-2 - 34-005 90/00388173 907021/30-1 - 10-005 90/00388174 907021/30-2 - 10-005 90/00388175 907021/31-1 - 34-005 90/00388176 907021/31-2 - 34-005 90/00388177 907021/40-1 - 14-051 90/00388179 907021/40-2 - 14-051 90/00388180

Data Sheet 90.7021 Page 6/6 Order details: Accessories (1) Basic version 907021/90 Filter 907021/91 Humidity sensors, capacitive 907021/92 Temperature sensor 907021/93 Humidity sensor check sets (2) Filter X 801 Membrane filter (standard) X 802 Sintered bronze filter X 803 Sintered stainless steel filter X 804 Metal mesh filter (2) Humidity sensors X 806 HC 1000 X 807 HC 200 X 808 HC 101 (2) Temperature sensor X 005 Pt 1000 (2) Humidity sensor checks X 820 33% rh magnesium chloride X 821 55% rh magnesium nitrate X 822 76% rh sodium chloride (1) (2) Order code - Order example 907021/90-801 Stock versions (1) (2) Sales No. - 907021/90-801 90/00388181 907021/90-802 90/00388182 907021/90-803 90/00388183 907021/90-804 90/00389114 907021/91-806 90/00388184 907021/91-807 90/00388185 907021/91-808 90/00388193 907021/92-005 90/00358359 907021/93-820 90/00332758 907021/93-821 90/00332759 907021/93-822 90/00332760