Multi-Application Peripherals and Accessories

Similar documents
IDNet and MAPNET II Addressable Devices

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

Rev. B. TrueAlert Addressable Controller Application Manual

Multi-Application Peripherals

Z-20 Fire Control Panels

TrueAlert Notification Appliances

TrueAlarm Analog Sensing

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

SIGA-CC1 Single Input Signal Module Installation Sheet

TECHNICAL DATA OBSOLETE

TrueAlarm Fire Alarm Controls

Print Specification. Publication. Instructions. Specific requirements. General requirements

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

TrueAlarm Analog Sensing

LifeAlarm Fire Alarm Control Panels

Releasing System Peripherals

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

SLVMC - Oncology & Infusion Remodel & Add 17D /4/2017

TrueAlarm Fire Alarm Systems

4007ES Fire Control Panels

Specification/ Data Sheet

TrueAlert Addressable Notification Appliances

TrueAlarm ES Analog Sensing

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

Fire Alarm System Accessories

Multi-Point Peripherals

TrueAlarm Analog Sensing

Release Control Fire Alarm Systems

Multi-Point Peripherals

, -9686, -9688, -9755, Duct Detector/Sensor Installation Instructions

System Accessories, LCD Annunciators

ECC-50/100C. Emergency Command Center

good things in small packages

asimplex 4020 Fire Alarm System Contractor Installation Instructions Technical Manuals Online! -

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

TrueAlert Addressable Notification

AL800ULADA. NAC Power Extender. Installation Guide

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

TrueAlarm Fire Alarm Controls

ALARMS Fire Alarm Priority 2 Alarm. Fire Alarm Priority 2. Ack Event Time Enable Disable Emergency Operating Instructions.

4007ES Fire Control Panels

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

30.45 Electric Release PDRP-2001

Multiple Input and Output Modules

June 10, 2002 DF C S2424

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

LifeAlarm Fire Alarm Controls

UEI-1 UNIVERSAL END-OF-LINE / ISOLATOR TESTER

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

TrueAlarm Addressable Fire Alarm Control Panels

Model 4880 Status Output Display Module Manual

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

TrueAlert Addressable Notification Appliances

ANNUNCIATOR FIXED MODULE

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

ECC-50/100(E) Emergency Command Center

TrueAlert Addressable Notification Appliances

F220-B6PS/M. Installation Guide. Addressable Detector Bases

4100ES Fire Control Panels

TrueAlarm Smoke Detectors

Expansion Modules & Accessories

Electric Release Panel Wiring Tips

TrueAlert Addressable Notification Appliances

TrueAlert ES Addressable Notification Appliances

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

FireShield Plus. GE Security. EST Life Safety & Communications Conventional Small Building Solutions. Conventional Fire Alarm Control Panels

INSTALLATION AND MAINTENANCE

Fire Control Units. Addressable Fire Detection and Basic Control Unit Modules and Accessories. UL, ULC Listed, FM Approved* Features

INTELLIGENT FIRE ALARM CONTROL PANEL

A. This Section covers fire alarm systems, including initiating devices, notification appliances, controls, and supervisory devices.

4007ES Fire Control Panels

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

/5121/5122 TrueAlert Power Supply Installation Instructions

Signature Series Auto-Sync Output Module (CC1S)

AND ARCHITECT SPECIFICATIONS

E-FSC. Conventional Fire Alarm Control Panels. Standard Features. Overview

B. Special Documentation Requirements. C. Materials and methods of Construction

These instructions detail procedures to follow in order to avoid damage to equipment.

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

RELEASE DEVICE CONTROLS

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT

MODEL B2 INSTALLATION MANUAL

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 28 Electronic Safety and Security 4600 Fire Detection and Alarm

4.1 Mounting the 5820 Cabinet Removing the 5820 Assembly from the Housing AC Connection Battery Connection...

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Commercial and Light Industrial Fire Alarm Control Panel

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

Transcription:

ON UL, ULC Listed FM Approved MultiApplication Peripherals and Accessories Communicating Devices Communications Individually Addressable Devices FEATURES Individually addressable communications over a single pair of wires for interfacing to: Initiating devices Notification appliance circuits Control relays Fire alarm control panel displays device location and status, for use with Simplex: 4100 Series fire alarm control panels 4100 Series Universal Transponders 4120 Series Network node fire alarm control panels 4020 Series fire alarm control panels 2120 Communicating Device Transponders Zone Adapter Modules (ZAMS): Provide addressable interface to conventional zoned circuits communications* can be wired: NFPA Style 4/Class B or Style 6/Class A Style 4/Class B communications may be wired either T tapped or In/Out Convenient DIP switch address selection UL listing Standards: Addressable stations are listed to Standard 38 All other addressable devices are listed to Standard 864 INTRODUCTION communicating devices individually annunciate identity and accurate status to the connected control panel. Applications include interface to manual fire alarm stations, sprinkler flow switches (or any typical fire detecting device) and addressable control. New installation wiring is via twisted, shielded wire. Performance is compatible with most retrofit wiring where unshielded and untwisted wire exist. GENERAL SPECIFICATIONS input...24 to 40 VDC with data Current... see chart, page 2 Address Means... DIP switch, 8 position Temperature... 32 F to 120 F (0 C to 49 C) Humidity... 85% noncondensing @ 86 F (30 C) PULL DOWN Addressable Manual Stations 21909155.09A 21909157.012A INSTAL. INSTRUC. 575592 21909161.04A 21909163.04A INSTAL..INSTRUC. 575279 3333 BAUD RATE 28 VDC 519576 A ADDRESS CODE Zone Adapter Modules (ZAMs) 519638 A D D R E S S C O D E Supervised Individual Addressable Module (IAM) * MAPNET addressable communication operation is protected by U.S. Patent No. 4,796,025. SIMPLEX TIME REC. CO. 1999 Simplex Time Recorder Co. All rights reserved. S2190001213 7/99

ADDRESSABLE DEVICE SELECTION CHART Addressable Manual Fire Alarm Stations*** (refer to page 3) Model Description Current 20999795 Single Action 20999797 Single Action, Local Fire Alarm Cover 20999796 Double Action, Breakglass 20999761 Double Action, PushPull 20999135 Double Action, PushPull without Simplex logo 20999813 Semiflush Trim Plate 20999814 Surface Trim Plate 29759178 Back Box Supplied by communications Not Applicable Zone Adapter Modules, Monitor ZAMs* (separate 24 VDC power required) (refer to page 4) Model Cover Type Description Supervisory Current Alarm Current 21909153 Surface 21909154 Flush Monitor ZAM, Style D 21909155 Surface 21909156 Flush Monitor ZAM, Style B 20 ma @ 24 VDC 90 ma @ 24 VDC 21909157 Surface 21909158 Flush 4Wire Detector ZAM Zone Adapter Modules, Signal and Control ZAMs* (separate 24 VDC power required) (refer to page 5) Model Cover Type Description Supervisory Current Alarm Current 21909159 Surface 21909160 Flush 21909161 Surface 21909162 Flush 21909163 Surface 21909164 Flush Signal ZAM, Style Z 15 ma @ 24 VDC 65 ma @ 24 VDC Signal ZAM, Style Y Control Relay ZAM, DPDT Contacts 15 ma @ 24 VDC 10 ma @ 24 VDC 40 ma @ 24 VDC Addressable Supervised IAM* (refer to page 7) Model Description Ref. Data Sheet Current 21909172 Supervised IAM** S21900018 Supplied by communications * For ULC listed products, add a C suffix (example: 20989201 C). ** 21909172 is considered as 1.5 devices each for circuit loading. Refer to data sheet S21900018 for more information. *** For ULC listed products, add the suffix C if in English, CF if in French, or CB if Bilingual. S2190001213 7/99 page 2

ADDRESSABLE MANUAL STATIONS addressable manual stations have an integrally mounted addressable module that monitors the station contact status and communicates changes to the connected control panel via the communications wiring. Addressable stations are available in either single or double action or single action with Local Alarm cover. Mounting is surface or semiflush using either standard boxes or the Simplex red back box, model 29759178. Addressable Manual Station Mounting Options LOCAL PULL DOWN 20999814 Surface trim for Wiremold box 5 1/8"H x 5"W (130 mm x 127 mm) Wiremold receptacle box (by others) see note 1 Gangable switch box (by others) see note 2 20999797, Single Action with "LOCAL " Cover BREAK GLASS PULL DOWN PULL DOWN 20999796 Double Action, Breakglass PULL PUSH DOWN 20999795, Single Action Addressable Manual Station Housing dimensions: 5" H x 3 3/4" W x 1" D (127 mm x 95 mm x 25 mm) 20999813 Semiflush trim for 2gang switch box 6" H x 4 1/2" W (152 mm x 114 mm) 20999761 Double Action, PushPull Simplex 29759178 box, no mounting plate required 5 3/16" H x 4" W x 2 3/16" D (132 mm x 102 mm x 56 mm) see note 3 Notes: 1. Use a Wiremold box no. 57442, deep receptacle box, 4 3/4 L x 4 3/4 W x 2 1/4 D (121 mm x 121 mm x 57 mm), with the 20999814 surface trim band. 2. Use two gangable switch boxes, 3 L x 2 W x 2 3/4 D (76 mm x 51 mm x 70 mm), with the 20999813 semiflush trim band. 3. When the 29759178 box is used, no trim is required. 4. The address code dipswitch is accessible when the pull station cover is in the open position. S2190001213 7/99 page 3

ZONE ADAPTER MODULE MONITOR ZAM Monitor ZAMs are used when the fire detecting devices or supervisory switches are mounted separately from the addressable electronics. It provides status monitoring and supervision to the device circuit zone and is used for circuits with nonaddressable detectors and for other contact closures such as waterflow and tamper switches or nonaddressable manual stations. Monitor ZAM models are available for monitoring as: Style B (Class B) Style D (Class A) Style B with separate detector power output (4wire detector operation) Typical ZAM Mounting, Monitor, Signal, or Control 4 11/16" (119 mm) Square box, 2 1/8" (54 mm) deep ZAM assembly SIMPLEX TIME REC. CO. 21909155.09A 21909157.012A INSTAL. INSTRUC. 575592 21909161.04A 21909163.04A INSTAL..INSTRUC. 575279 3333 BAUD RATE 28 VDC 519576 A ADDRESS CODE 4 11/16" (119 mm) Square extension ring, 1 1/2" (54 mm) deep Flush cover, 5 7/16" square (138 mm) Surface cover, 4 15/16" square (125 mm) Monitor ZAM Wiring Diagrams 24 VDC "T" Tapped or IN/OUT wiring Monitor ZAM Class B, Style B 2 wire monitor circuit Shield Monitor circuit Monitor circuit Return Resettable Detector power End of line relay Class A/Style D 2wire monitor circuit 4 Wire detector ZAM wiring S2190001213 7/99 page 4

ZONE ADAPTER MODULE SIGNAL ZAM Signal ZAMs are used to supervise and operate 24 VDC notification appliances, speakers, and telephone circuits. Output capacity is up to 2 A @ 24 VDC, or 50 W of 25 VRMS speakers, or up to three simultaneously activated firefighter phones. The signal ZAM is available for either Style Y/Class B or Style Z/Class A operation for notification appliance circuits. Wiring diagrams are shown in the following illustrations. Signal ZAM Wiring Information "T" Tapped or IN/OUT wiring 24 VDC Class B/Style Y notification appliance circuit (speakers shown for reference) Signal input, audio or phone Shield Primary Return Class A/Style Z notification appliance circuit Signal input, audio or phone ZAM Package Reference Drawings SIMPLEX TIME REC. CO. 21909155.09A 21909157.012A INSTAL. INSTRUC. 575592 21909161.04A 21909163.04A INSTAL..INSTRUC. 575279 3333 BAUD RATE 28 VDC 519576 A SIMPLEX TIME REC. CO. 21909155.09A 21909157.012A INSTAL. INSTRUC. 575592 21909161.04A 21909163.04A INSTAL..INSTRUC. 575279 3333 BAUD RATE 28 VDC 519576 A ADDRESS CODE ADDRESS CODE Signal ZAM/Control ZAM Monitor ZAM S2190001213 7/99 page 5

ZONE ADAPTER MODULE CONTROL ZAM Control ZAMs are used to provide addressable control functions such as elevator capture, HVAC control, pressurization fan control, damper control, etc. Control ZAM Wiring Diagram Control ZAM "T" Tapped or IN/OUT wiring 24 VDC N. C. 1 Common 1 N.O. 1 N. C. 2 Shield Common 2 N.O. 2 Controlled device Control Power Control ZAM Relay Ratings (DPDT Contacts) Application Resistive Rating Inductive Rating** Power Limited* 2 A @ 28 VDC 1 A @ 28 VDC NonPower Limited 2 A @ 28 VDC 1 A @ 28 VDC 1/2 A @ 120 VAC 1/2 A @ 120 VAC * DC Voltage must be from a listed Fire Alarm power supply. ** Inductive loads must be properly suppressed. S2190001213 7/99 page 6

SUPERVISED INDIVIDUAL ADDRESSABLE MODULE (IAM), MODEL 21909172 The 21909172 Supervised IAM provides location specific addressability to a single initiating device or multiple devices by monitoring normally open, dry contacts. Closure of the monitored contacts initiates an alarm. An open in the initiating circuit wiring will cause a trouble to be reported at the fire alarm control panel. The small package size of 2 1/4 L x 1 1/8 W x 1/2 D (57 mm x 29 mm x 13 mm) allows easy mounting. If the initiating device contacts are momentary, such as from a rateofrise heat detector, enabling the latch feature allows the IAM to latch the alarm condition until the system is reset. For applications where the contact closure latches, or if its condition needs to be tracked at the control panel, nonlatching operation may be enabled. The following illustrates typical connection information for interfacing into a Simplex fire alarm control panel via. Use with a single station detector is to annunciate the alarm status and to supervise the connector. By using a separate, additional IAM, an isolated heat sensor contact can be monitored. Typical Supervised IAM Wiring Diagrams RED 21909172 SUPERVISED IAM MONITOR (YELLOW) MONITOR (GRAY) TYPICAL INITIATING DEVICES TYPICAL SINGLE STATION SMOKE DETECTOR CONNECTION BLACK INTERNAL ENDOFLINE RESISTOR MAXIMUM DISTANCE FROM ENDOFLINE RESISTOR TO MONITOR WIRES IS 400 FT. ALTERNATE ENDOFLINE RESISTOR LOCATION (100 kω, 1/2W) HEAT SENSOR GRAY GRAY 21909172 SUPERVISED IAM AUX. CONTACTS CONTACTS TANDEM YELLOW ORANGE BLUE VIOLET VIOLET/BLACK RED/YELLOW BLACK YELLOW GRAY MONITOR INTERNAL ENDOFLINE RESISTOR RED BLACK CONNECTION POWER WHITE TO 120 VAC S2190001213 7/99 page 7

ON Supervised IAM Mounting with Single Station Detector 4" (102 mm) Square box, 2 1/8" (54 mm) deep DETECTOR WILL NOT OPERATE WITHOUT POWER ON 519638 A D D R E S S C O D E NORMAL WARNING: READ INSTRUCTION MANUAL: TO ORDER, WRITE TO ADDRESS ON BACK TEST 1 GENTEX TEST WEEKLY 21909172 Supervised IAM Single Station (Residential) Detector Simplex, the Simplex logo, and are registered trademarks of the Simplex Time Recorder Co. in the U.S. and/or other countries. NFPA is a registered trademarks of the National Fire Protection Association. S2190001213 7/99 Gardner, Massachusetts 014410001 U. S. A. Offices and Representatives Throughout the World Visit us on the world wide web at www.simplexnet.com. All specifications and other information shown were current as of printing and are subject to change without notice.