SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Similar documents
4) Intrinsic Safety Certification

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Inductive slot sensor

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

RT FLOW RATE TOTALISER

SET Installation and Operating Instructions. Level switch for one sensor

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Technical Data. Dimensions

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

SET-2000 Hi Level/Oil

Technical Data. Dimensions

AO Annunciator Module

INSTRUCTION MANUAL (ATEX)

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

PEPPERL+FUCHS GmbH

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

IECEx Certificate of Conformity

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

Technical Data. Dimensions

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Certificate of Compliance

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Technical Data. General specifications. Rated operating distance s n 5 mm

INSTRUCTION MANUAL. Frequency-Pulse Converter, Repeater and Trip Amplifiers Din-Rail Model D1060S D1060S

Instrumentation Products and Applications

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

E2S Datasheet v10a

Technical Data. Dimensions

Process Alarm Module RTA 421

PROTECT SRB 200EXi-1A

SET-2000 Oil/Sludge 12 VDC

Intrinsically Safe Flame Detector Installation Guide

Operating Instructions Edition 02/2007

EU DECLARATION OF CONFORMITY

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

OilSET-1000 (12 VDC)

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

DB5 Intrinsically Safe Sounder Type DB-5

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

FDCL221-Ex Line adapter (Ex)

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

OPTIBAR P 1010/2010 C Supplementary instructions

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Declaration of conformity

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Operating Manual MS220DA

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Universal Tank Alarm Type Installation, Operation & Maintenance

IECEx Certificate of Conformity

OPTIWAVE X500 Supplementary Instructions

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

Manual Isolating Barrier D461R1 (Revision 01)

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

industrial electronics electronic level measurement system

FAHM Co. Temperature Transmitter PTT74 Series

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Intrinsically Safe Solutions

OPTIBAR DP 7060 Supplementary Instructions

FDOOT241-A9-Ex Multisensor fire detector

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Annubar Flowmeter Series

VERSAFLOW VORTEX Supplementary instructions

BA374C Intrinsically safe field mounting indicating temperature transmitter

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

INSTRUCTION & SERVICE MANUAL

OOH740-A9-Ex Multi-sensor fire detector

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

OOH740-A9-Ex Multisensor fire detector

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

Integrated Solutions Low Voltage Systems

INSTRUCTION MANUAL (ATEX / IECEx)

Manual Isolating Barrier D461 (Revision 05)

srra, of Conformity IECEx Gert f cate ?-ot,b

Leakage detection sensor

Rosemount 3490 Series

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

Installation and Operating Instruction

IECEx Certificate of Conformity

INSTRUCTION MANUAL (ATEX / IECEx)

DICTATOR Hold-Open Systems for Hazardous Areas

Operating Manual MS220KA and MSR220KA

Manual Power relay SR853

Transcription:

SBEx-4 BISTATE SEPARATOR,, 3 or 4 channels in rail housing (TS3,,mm width) - group I category (M), group II and III category () accompanying device, - intrinsically safe input circuits with ia protection level compliance with ATEX, - EC-Type Examination Certificate: KDB 04ATEX0/ ATEX FEATURE: I (M) [Ex ia] I; II () G [Ex ia] IIC; II () D [Ex ia] IIIC Protection level IP0 Operating temperature range -..+0 C Inputs: NAMUR proximity sensors, opto-relays, contacts, transistor switches etc. Can be used as resistance value comparator. Relay or opto-relay outputs. Version SBEx-4 option Q is a functional substitute for separator D03Q. Output of channel number and 3, as well as and 4 have a common terminal. Version SBEx-4 option D is a functional substitute for separator D03D. Output of channel number and 3, as well as and 4 have a common terminal. Activation phase is settable with switchers accessible after opening the housing. Inputs, outputs and power supply are mutually galvanically separated. - Intrinsically safe input circuits can operate with intrinsically safe circuits with ia or ib protection level of a device installed in explosion hazardous zone group I and in zones 0,,, 0,, of group II of any mixtures including e.g. proximity sensor, turbine flow sensor, contact etc. - Output, ALARM indication and power supply circuits can operate with any non-intrinsically safe circuits of devices with voltage Um=3V e.g. supplied from 30Vac network. - Separator can be installed in a room that is safe in terms of explosion and protected against access of persons not trained in maintenance and operating the transducer. - Separator installed in a hazardous area can have a flameproof housing. Separator can be removed from the housing shortly after power in group I is turned off, because it does not contain any energy storage elements and do not become too hot. A 0 minutes delay is necessary in group II and III (gases and dusts). SBEx-4 standard zone 0,,, 0,, safe zone 9,V In- 0,V In-,V 3 In3-4,V In4- Inputs: proximity sensor, potential-free contact, Supply OC transisotr NPN, PNP 4Vdc 3 + 4 - Out Out Out3 Out4 Alarm Note: While the power is turned off output relay s contacts Pk ; Pk, Pk ; Pk, Pk3 ; Pk, Pk4 ; Pk and alarm contacts PkA ; Pk are opened. Pk Pk Pk Pk3 Pk4 PkA Application: Separator can be used to transfer a of a contact or OC type transistor to galvanically separated side. It is designed to operate with NAMUR proximity sensors which switch current. /. ma (DIN 934). It can also be used as resistor values comparator. After agreement switching current can be adjusted as well as hysteresis width. These parameters should be specified in writing. Note: for SBEx-4 all four outputs ( Out, Out, Out3, Out4 ) together with Alarm output have common terminal number ( Pk ). Ordering code for standard : SBEx-4- binary separator,,,3 or 4 channels SBEx-4-- one channel SBEx-4-- two channels SBEx-4-3- three channels SBEx-4-4- four channels - PK PK, PK, PK3, PK4 relay outputs - OPTO OP, OP, OP3, OP4 opto-relay outputs Order example for standard : Binary separator, two channels, opto-relay outputs: type SBEx-4--OP/OP For atypical application switching resistance or current thresholds and hysteresis should be described. tel. 0 0 0, 0 9 4, fax 0 0 9 4; 04- Warsaw, ul. Czechowicka 9

Version SBEx-4 option Q is a functional substitute for separator D03Q. Outputs of channel number and 3, as well as and 4 have a common terminal. zone 0,,, 0,, Inputs: proximity sensor, potential-free contact, OC transisotr NPN, PNP SBEx-4 Q safe zone +,V Out Pk 9 In 0 +,V Out Pk In +,V Out3 Pk3 3 In3 4 +,V Out4 Pk4 In4 Supply 4Vdc 3 + 4 - Application of SBEx-4 option Q: There are four independent inputs. There is no ALARM opto-relay output. Detection of shorting or opening of connection line between separator s terminals and set of two resistors installed on the end of the line from hazardous zone side can be indicated only by LEDs. Outputs of channel and 3 have a common terminal number and are galvanically separated from output set of channel and 4 which have a common terminal number. Similar as in standard, output phase of each output can be set by switchers accessible after removing the housing. Ordering code for with option Q: is identical as for standard. Example: Binary separator, four channels, relay outputs: type SBEx-4-4-PK/PK/PK3/PK4 option Q Version SBEx-4 option D is a functional substitute for separator D03D. Outputs of channel number and 3, as well as and 4 have a common terminal. zone 0,,, 0,, In In Inputs: proximity sensor, potential-free contact, OC transisotr NPN, PNP SBEx-4 D safe zone +,V Out Pk 9 0 +,V Supply 4Vdc 3 + 4 - Out Out3 Out4 Pk Pk3 Pk4 Application of SBEx-4 option D: There are two independent inputs. Input In controls outputs number and 3. Input In controls outputs number and 4. There is no ALARM opto-relay output. Detection of shorting or opening of connection line between separator s terminals and set of two resistors installed on the end of the line from hazardous zone side can be indicated only by LEDs. Outputs of channel and 3 have a common terminal number and are galvanically separated from output set of channel and 4 which have a common terminal number. Similar as in standard, output phase of each output can be set by switchers accessible after removing the housing. Ordering code for with option D: is identical as for standard. Example: Binary separator, four channels, relay outputs: type SBEx-4-4-PK/PK/PK3/PK4 option D tel. +4 0 0, 0 9 4, fax 0 9 4; 04- Warsaw, ul. Czechowicka 9

On the input terminals is voltage.v. In case of driving the separator from NPN OC transistor terminals In+ 9, In+, In3+ 3, In4+ should be connected to collector. A typical sensor operating with the input of the separator is a sensor with output type NAMUR./.mA e.g. inductive proximity sensor. For atypical application values of resistance or current switching thresholds and hysteresis should be specified in the order. Switchers SW, SW, SW3, SW4 (accessible after removing the housing) are used for inversing output relays. Position ON means in operation of that channel. If switchers SW, SW, SW, SW (accessible after removing the housing) are set in ON positions detection of damage in input connection line is turned on. Position OFF means turning off damage line alarm in this channel. For SW, SW, SW3, SW4 OFF and for SW, SW, SW, SW ON output contacts and LED signalization is as follows: - increase of input signal above value switching level + 0. hysteresis causes shorting of output relay s contact (terminals Pk; Pk, Pk; Pk, Pk3; Pk, Pk4; Pk ) and lighting up green LED ( Pk, Pk, Pk3, Pk4 ). Lighting up red LED Alarm and contact PkA; Pk shorting means a break in connection line (I<0.mA). Lighting up orange LED Alarm and contact PkA; Pk shorting means shorting in connection line (I>mA). Contacts of alarm PkA, Pk are common signalization for all channels the user should check which channel is damaged by looking at LEDs. Note: to allow proper signalization of shorting/opening in sensor connection line in case of operating with contact or transistor, to the terminals of the sensor (in Ex zone) should be connected a parallel resistor 3 k and a serial resistor 90 000. It is shown on the figure on page. 3 Technical data: One, two, three or four channels with the following parameters. Input signal type - contact, transistor switch or NAMUR proximity sensor e.g. PCIN by SELS standard switching thresholds -.4 /. ma or according to the order sensor supply voltage -. V input resistance - k Opening in connection line - opened I < 0.mA signalization threshold not opened I > 0.3mA Shorting in connection line - I > 4.4mA signalization threshold not I < 3.9mA Output potential-free contact of relay PK, PK, PK3, PK4 - switching time - max 0 ms - switching frequency - max 0 Hz - mechanical durability - 0 (for Hz 4 months) - switched power - max A / 0Vac or 30Vdc Opto-relay - 30V, 0.A, 40 Hz, r=30 After agreement this opto-relay - 0V, 0.A, 00 Hz In SBEx-4 all outputs have common terminals marked as Pk. Output ALARM PKA - opto-relay - 30V, 0.A, 40 Hz, r=30 Power supply voltage - 0 30V DC ma for four channels ma for one channel Note: If supply voltage exceeds 30V the fuse of the protection barrier may be burnt repair only by the manufacturer. Galvani separation: isolation test voltage between inputs - kv inputs/outputs/supply - kv Connections - cables 0.. mm TS3 rail housing - housing and terminals IP0 housing material - self-extinguishing poliamid PA. compliance with directive EMC 004/0/WE - PN-EN 000--4, PN-EN 000-- Pk4 Pk3 Pk Pk PK4 PK3 PK PK PK4 PK3 PK PK -4 +3 4Vdc PkA Pk -4 +3 4Vdc -4 +3 4Vdc SBEx-4 99 PK PK4 Sup. PK PK3 Status/Alarm zone 0,,,0,, IN IN - + -0 +9 PK PK4 Sup. PK PK3 SBEx-4-Q zone 0,,,0,, IN IN - + -0 +9 PK PK4 Sup. PK PK3 SBEx-4-D zone 0,,,0,, IN IN - + -0 +9 4. IN 4 IN 3 - + -4 +3. IN 4 IN 3 + - -4 +3 tel. +4 0 0, 0 9 4, fax 0 9 4; 04- Warsaw, ul. Czechowicka 9

Configuration: Below table describes logic of output relays and respectively LEDs on the example of one channel. of relays and LEDs current ( of the input contact) I > ma ALARM ( line R L <300 ) I >. ma (shorting contact) I <.4 ma (opening contact) I < 0. ma ALARM (opened line R L >40k ) of output contacts in channels,, 3, 4 respectively for SW, SW, SW3, SW4 in OFF opened of output contacts in channels,, 3, 4 respectively for SW, SW, SW3, SW4 in ON opened 4 LED in channel with active alarm SW or SW or SW or SW in ON orange green off red LED in channel with inactive alarm SW or SW or SW or SW in OFF green off of PkA; Pk ALARM contact with active alarm in channel SW or SW or SW or SW in ON opened if no alarms on other channels of PkA; Pk ALARM contact with inactive alarm in channel SW or SW or SW or SW in OFF opened if no alarms on other channels In SBEx-4 all output contacts Pk; Pk, Pk; Pk, Pk3; Pk, Pk4; Pk and alarm contact PkA; Pk have one common terminal Pk. It means that output terminals are not galvanically separated from each other. Safety parameters for SBEx-4 input circuits with ia protection level: Terminal sets IN, IN, IN3, IN4 for SBEx-4 are individual galvanically separated intrinsically safe circuits. For simultaneous connection of these circuits can be used one multi-wire cable type A or B compliant with IEC 009-4 or separated cables. a) Intrinsically safe input circuits: IN - terminals 9-0, IN - terminals -, IN3 - terminals 3-4, IN4 - terminals - for SBEx-4 Clustered parameters Lo, Co. Clustered values Co, Lo and connection cable parameters L/R should be taken according to the table below. Data refer to clustered values can also be applied to cables. Uo Io Po L/R [mh/ ] Lo [H] Co [ F] [V] [ma] [mw] I and IIA IIB IIC I and IIA IIB IIC I and IIA IIB IIC 0, 0, 0, 4, 0, SBEx-4 0 9, 0 4,3,, 0,0 0,0 0,0 4,3 3 0, 0,0 0,0 0,00 4,9 3,4 0,3 Distributed parameters Lo, Co. Distributed values Co, Lo for connection cable should be taken according to the table on the right. L/R connection cable parameters should be taken according to the table above. Lo [mh] Co [ F] I and IIA IIB IIC I and IIA IIB IIC SBEx-4 00 00 00 0 3, Safety parameters with serial galvanic connection of any of two out of four separated intrinsically safe input circuits for SBEx-4. Sets (set is two serial connected circuits) of galvanically separated intrinsically safe input circuits are individual intrinsically safe circuits. For simultaneous connection of these circuits can be used one multiwire cable type A or B compliant with IEC 009-4 or separated cables. tel. +4 0 0, 0 9 4, fax 0 9 4; 04- Warsaw, ul. Czechowicka 9

Clustered parameters Lo, Co. Clustered values Co, Lo and connection cable parameters L/R should be taken according to the table below. Data refer to clustered values can also be applied to cables. Uo Io Po L/R [mh/ ] Lo [mh] Co [ F] [V] [ma] [mw] I and IIA IIB IIC I and IIA IIB IIC I and IIA IIB IIC 0 0 0, 0, 0, SBEx-4 0 9, 0 4 3 0,,4 0,9 0,,, 0, Distributed parameters Lo, Co. Distributed values Co, Lo for connection cable should be taken according to the table on the right. L/R connection cable parameters should be taken according to the table above. Lo [mh] Co [ F] I and IIA IIB IIC I and IIA IIB IIC SBEx-4 00 00 00,,4 0,4 Safety parameters with parallel galvanic connection of any of two out of four separated intrinsically safe input circuits for SBEx-4. Sets (set is two parallel connected circuits) of galvanically separated intrinsically safe input circuits are individual intrinsically safe circuits. For simultaneous connection of these circuits can be used one multiwire cable type A or B compliant with IEC 009-4 or separated cables. Clustered parameters Lo, Co. Clustered values Co, Lo and connection cable parameters L/R should be taken according to the table below. Data refer to clustered values can also be applied to cables. Uo Io Po L/R [mh/ ] Lo [H] Co [ F] [V] [ma] [mw] I and IIA IIB IIC I and IIA IIB IIC I and IIA IIB IIC 0 0 0 3,9, 0, SBEx-4 0 9, 0 4 3 0, 0 0 4,4 3,0 0,, 3, 0,9 Distributed parameters Lo, Co. Distributed values Co, Lo for connection cable should be taken according to the table on the right. L/R connection cable parameters should be taken according to the table above. Lo [mh] Co [ F] I and IIA IIB IIC I and IIA IIB IIC SBEx-4 00 00 00 0 3, b) Non-intrinsically safe circuit parameters: terminals Um SBEx-4 Pk-Pk terminals -, Pk-Pk terminals -, Pk3-Pk terminals -, Pk4-Pk terminals -, PkA-Pk terminals - and Supply 4V - terminals 3-4 3 V Application condition: Maximal value of capacitance and inductance joined to intrinsically safe terminals IN, IN, IN3, IN4 should be selected based on joining circuits safety parameters (given in conditions of use of devices which will be connected to the input of the separator SBEx-4) but cannot exceed the values given in the tables above. ATEX compliance - directive 94/9/WE: PN-EN 009-0:009, PN-EN 009-:0, PN-EN 0303:004. tel. +4 0 0, 0 9 4, fax 0 9 4; 04- Warsaw, ul. Czechowicka 9

Operation condition : Ambient temperature - for storage - -30 +0 C Ambient temperature - operation - - +0 o C Relative humidity - max 90% Ambient atmosphere - no dust and aggressive gases Working position - any Configuration additional information: Phase activation selection of output relays (does not concern alarm relay) and activation of connection line breaking detection alarm is made by switches SW, SW, SW3, SW4 accessible after opening the housing. Table. Channel 3 4 output output contact Pk; Pk output contact Pk; Pk output contact Pk3; Pk output contact Pk4; Pk input input opened I <.4 ma when SW OFF when SW OFF when SW3 OFF when SW4 OFF input opened I <.4 ma when SW ON when SW ON when SW3 ON when SW4 ON input closed I >. ma input closed I >. ma when SW OFF when SW ON when SW OFF when SW ON when SW3 OFF when SW3 ON when SW4 OFF when SW4 ON Choosing of a channel from which detection of connection line damage is summed to the result of detection from other channels is selected with switches SW, SW, SW, SW accessible after removing the housing. Table. Channel 3 4 detection of connection line damage alarm off when SW OFF when SW OFF when SW OFF when SW OFF alarm on when SW ON when SW ON when SW ON when SW ON Table 3 describes function of switches for setting output relays phase: in or no in. State no in : Iin>.mA input output State in : Iin>,mA input output. Switchers SW, SW, SW3, SW4 refers respectively to phase in of output relays contacts PK, PK, PK3, PK4. Table 3. switchers relays PK channel relay PK channel relay PK3 channel 3 relay PK4 channel 4 relay SW, SW, SW3, SW4 ON in OFF no in Table 4 describes function of switcher for activation or blockade ALARM function for each channel. There is one common output terminal PkA; Pk for ALARM function. It operates as a logical sum it is enough if alarm appears on only one of channels activated for alarm. Switchers SW, SW, SW, SW refers respectively for activation of detection of alarm s I<0.mA or I>mA in channels,, 3, 4. Contacts PkA; Pk us closed when I<0.mA or I>mA on at least one of channels activated for alarm. Table 4. switchers LEDs status/alarm and ALARM relay LEDs Pk, Pk, Pk3, Pk4 contacts PkA; Pk of ALARM relay SW, SW, SW, SW ON OFF - red - off I < 0. ma I < 0. ma - orange - green I >. ma I >. ma - closed - opened When in one of channels All = OFF or in all activated for alarm channels activated I<0.mA or I>mA for alarm 0.3<I<4mA tel. +4 0 0, 0 9 4, fax 0 9 4; 04- Warsaw, ul. Czechowicka 9