HIGH-POWER HEAT PUMPS. Up to 300 kw

Similar documents
your tree NEW TREE for you Several facts on trees: Follow our Green Tree heat pumps

AIRLINE - commercial heat pumps Air / water heat pump for heating, cooling and DHW production - commercial use

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

HEAT PUMPS LINE AS AIR TO WATER

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

V018-EN-02 AIR TO WATER HEAT PUMPS 2019 HEART OF YOUR HOME

Technical data LA 60TU

Technical data LA 9S-TU

Technical data LA 28TBS

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

ECOFOREST GEOTERMIA. ecogeo. Ground/Air Source Heat Pumps.

Advance Split

Heating with airborne and geothermal energy making the best possible use of renewables

V016-EN-01 AIR TO WATER HEAT PUMPS 2016 HEART OF YOUR HOME

EVI Scroll Air To Water Heat Pumps

V017-EN-01 AIR TO WATER HEAT PUMPS HEART OF YOUR HOME

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Technical data LA 60TUR+

Starting current with soft starter Fuse protection

Technical data. Danfoss DHP-L

Heat pumps. Heating systems Industrial systems Refrigeration systems

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Natural geothermal energy

HITACHI line up: YUTAKI S 80 Very high water temperature Heat Pump

LZT High efficiency air to water heat pumps with E.V.I. compressors

Natural Heat VITOCAL 300-A VITOCAL 350-A. Air source heat pumps

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

PRODUCT RANGE HEAT PUMPS 2012

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

H4T R410A. refrigerant

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Press. Heat pumps from Viessmann: efficient heat generation with renewable energy and electricity

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

NIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump

Oilon Ground Source Heat Pumps

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

VIESMANN. VITOCAL Air/water heat pumps. Technical guide. VITOCAL 300-A Type AWC-I and AW-O. VITOCAL 350-A Type AWH-I and AWH-O


NABILATON PRO. The Nabilaton Pro heat pumps consist of MDV brand outdoor units and suitable hydraulic modules from Nabilaton.

Dimplex High efficiency air-to-water heat pump for indoor installation. (Low temperature) Order reference

S-Therm Air to Water Heat Pumps

Starting current with soft starter Fuse protection. Heat source connection

Heating with airborne and geothermal heat

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

Starting current with soft starter Fuse protection

WZH Ground source heat pumps

WHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES

Type summary Albatros 2

SUMMARY. S-THERM+, S-THERM and SWH technology. S-THERM+ introduction. S-THERM indoor unit. S-THERM outdoor unit. S-THERM+ control

WHY A MHI HEAT PUMP?

Heating with natural heat

50A KP 70A KP 90A KP 120A KP 150A KP 210A

Ground Source Heat Pumps

LZA High efficiency air to water heat pumps with HP compressor

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

Do you want a versatile solution

Technical description. Atec.

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

THE HEART OF YOUR COMFORT

Efficient heating that won t cost the earth

HEAT PUMPS EN - flyer 10/p/2017 Made in Poland

Technical Information

Aquaflair TRAC-TRAF-TRAH

Planning guide. Atec.

LG Electronics AE Company, Commercial Air Conditioning

Heat pump systems and Chillers

- cooling operation - built-in heat meter - electronic circulating pumps

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

Control Products & Systems OEM

PRODUCT LINEUP AIR TO WATER. For RESIDENTIAL. Room Heating & Cooling

PRODUCT GUIDE

LG Electronics AE Company, Commercial Air Conditioning

prestige Control Application Supplement - TriMax

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

A2/W35: 8.6kW, Power consumption: 2.39kW, COP 3,6. A2/W35: 10.1kW, Power consumption: 2,8kW, COP 3,6

Heat Pumps. ground-to-water models air-to-water models. Energy-saving solutions

Air cooled industrial chillers

HEAT PUMPS AQUAGOR G / TERRAGOR G / AEROGOR SPLIT G 55/62 C -20 C

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

HT V2 HT Split

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Mobile Heating System K e - for high comfort and remote control. HEYLO All Rights Reserved. EXPERT FOR PROFESSIONALS

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Air / Water Heat Pump - Compact Design Modulating 8 18 kw

Air to water Heat Pump System

EVI + INVERTER MODELS A Q U A P U R A

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating

Technical data. Danfoss DHP-A

CONTENT. S-THERM+, S-THERM and SWH technology. S-THERM+ introduction. S-THERM indoor unit. S-THERM outdoor unit. S-THERM+ control

BWL air heat pumps BWS brine heat pumps

food-retail.danfoss.com Overview Brochure ADAP-KOOL Evaporator Controllers Achieve best-in-class energy efficiency and food safety

Transcription:

HIGH-POWER HEAT PUMPS Up to 300 kw 1

2

NEW GENERATION OF HEAT PUMPS GORENJE 4 COMPLETE RANGE OF NEW GENERATION HIGH-POWER HEAT PUMPS 8 MODERN CONTROL UNIT HEAT PUMPS AIR-WATER 10 Heat pumps AEROGOR COMPACT W 11 Heat pumps AEROGOR COMPACT EVI W 12 Heat pumps AEROGOR SPLIT AW W 13 Heat pumps AEROGOR SPLIT AW EVI W 14 Heat pumps AEROGOR SPLIT HD W 15 Heat pumps AEROGOR SPLIT HD EVI W GEOTHERMAL HEAT PUMPS BRINE-WATER AND WATER-WATER 18 Heat pumps AQUAGOR TERRAGOR W 19 Heat pumps AQUAGOR TERRAGOR EVI W 20 Table of recommended circulating pumps 21 Operating range 22 Technical specification 3

COMPLETE RANGE OF NEW GENERATION HIGH-POWER HEAT PUMPS Model name Outlet water temperature Number of compressors Model name Outlet water temperature Number of compressors Model name Outlet water temperature Number of compressors Aerogor Compact 25 54 W 60 C 1 Aerogor Split AW 25 54 W 60 C 1 Aerogor Split HD 107 W 60 C 2 Aerogor Compact EVI 27 56 W 65 C 1 Aerogor Split AW EVI 20 55 W 65 C 1 Aerogor Split HD EVI 109 W 65 C 2 4

Model name Outlet water temperature Number of compressors Model name Outlet water temperature Number of compressors Model name Outlet water temperature Number of compressors Aerogor Split HD EVI 163 W 65 C 3 Aquagor 37 W 60 C 2 Aquagor 50-115W 60 C 2 Terragor 28 W 60 C 2 Terragor 38-83 W 60 C 2 Aquagor EVI 48-126W 65 C 2 Terragor EVI 37-98 W 65 C 2 5

MAIN ADVANTAGES OF HEAT PUMP WATER HEATERS -20 C LOW OPERATING COSTS HIGH TEMPERATURE OPERATION OPERATION AT ENVIRONMENT TEMPERATURE OF DOWN TO -20 C EUROPEAN QUALITY SILENT AND RELIABLE OPERATION Efficient operation with high coefficient of performance excellent COP. The heat pump reaches high temperatures of heating water; therefore, it is also suitable for conventional radiator systems. It is appropriate for both floor heating and radiator heating system (with higher heating water requirements of up to 65 C). The system can successfully operate down to environment temperatures of -20 C. Components by European manufacturers are installed in the heat pump, which guarantees quality and long useful life. It is allowed by the scroll compressor technology, topclass sound insulation, and ultrasilent axial fan. 6

ECONOMICAL AND EFFICIENT GORENJE HIGH-POWER HEAT PUMPS ARE INTENDED FOR LARGE BUILDINGS Economical and efficient heating system with Gorenje heat pumps is a smart choice for both new and existing buildings. High-power heat pumps are intended for larger buildings housing, for example, public institutions (schools, kindergardens, banks etc.) or smaller to medium-sized industrial and commercial premises (offices, sports halls, restaurants etc.). They are suitable for both low-temperature heating systems (new buildings with floor heating or low-temperature radiators) and buildings with high-temperature heating systems with conventional radiators (refurbished or older buildings) as they can heat the water to a temperature of 55 to 65 C. We offer two types of high-power geothermal heat pumps: Characteristics of high-power heat pumps: Aquagor W water/water heat pumps with heating capacity ranging from 37 to 115 kw. Terragor W brine/water heat pumps with heating capacity ranging from 28 to 83 kw. Aquagor EVI W water/water heat pump with heating capacity ranging from 48 to 126 kw. Terragor EVI W brine/water heat pumps with heating capacity ranging from 37 to 98 kw. Moreover, we offer different types of air-water heat pumps with wide range of heating capacity (20-163 kw): Aerogor Compact 25-54 W Aerogor Compact EVI 27-56 W Aerogor Split AW 25-54 W Aerogor Split AW EVI 20-55 W Aerogor Split HD 107 W Aerogor Split HD EVI 109/163 W Geothermal heat pumps operate in two levels/cycles: Two compressors operate in a cascade system to allow the adjustment of heating power to the heating requirements of the building in different periods of the heating season. High-temperature heat pumps can heat the water to a temperature of 65 C: Aerogor Compact EVI W / Split AW EVI W / Split HD EVI W Terragor EVI W Aquagor EVI W Low-temperature heat pumps can heat the water to a temperature of 55 to 60 C: Aerogor Compact W / Split AW W / Split HD W Terragor W Aquagor W Complete range or air-water heat pumps allows active cooling mode during the hot summer months (serial integrated 4- way reversible valve and electronic expanison valve enables this procces). Geothermal heat pumps (brine-water / water- water) allows passive cooling mode in combination with preheat exchanger. Active cooling mode - optionally (on the request). ACTIVE/PASIVE COOLING HEATING MODE The heat pumps can operate in cascade system: 60/65 C DOMESTIC HOT WATER ACTIVE COOLING HEATING MODE DOMESTIC HOT WATER 7

MODERN CONTROL UNIT Modern control unit allows different settings for heating, cooling, and domestic hot water heating. The regulation is weather-dependent. The control unit regulates the heat pump and heating system operation according to the outdoor environment temperature and the desired indoor temperature in the user s home. Owing to a special algorithm, the heat pump only generates as much heat as required by the heating system, in any given moment. Basic regulation Basic regulation of RVS 61 supports two independent heating circuits one direct and one mixing circuit. For each circuit, the heating curve is set independently. Basic regulation of RVS 21 supports regulation of one direct heating circuit and DHW circuit. Basic regulation (RVS 61 and RVS 21) also supports heating of sanitary water with anti-legionella program, as well as alternative sources such as solar panels or wood-fired furnaces. It also allows hasslefree regulation of additional sources such as a heating oil or gas burner. Electronic controls are universal for all types of heat pumps and heating methods. In case of major systems, upgrading the basic regulation unit is quite straightforward. In most cases, heating circuit regulation depends on the exterior temperature. The heating curve depends on the characteristics of the building being heated, which is the only warranty that the heat pump, regardless of the outdoor temperature, will always heat the water to the lowest acceptable temperature. The level of temperature thus defines the efficiency of the heating system. The lower the heating temperature, the higher the Coefficient of Performance. RVS 21 RVS 61 Easy control Menu navigation is plain and simple. Each screen is indicated with a consecutive number so that the user is aware at all times which page of the menu is currently open. Commands re indicated with appropriate wording. The unit can be controlled via user keyboard on the heat pump, or through an additional room control unit. Basic functions are available through keys on the control unit and heating system temperature is easily set with a rotating dial located in the middle of the control unit. For advanced users, controls can also be routed hrough interfaces to a personal computer or even to an intelligent home system. INSTALLED HP CONTROLLER SIEMENS RVS 61 Control of direct HC*: Control of DHW circuit: Control active/passive cooling mode: Control of mixing HC*: Control of direct pump HC*: Solar system control: *HC = heating circuit Aerogor Compact 25 54 W Aerogor Compact EVI 27 56 W Aerogor Split AW 20 54 W Aerogor Split AW EVI 25 55 W Aerogor Split HD 107 W Aerogor Split HD EVI 109 W Aerogor Split HD EVI 163 W Aquagor Terragor W INSTALLED HP CONTROLLER SIEMENS RVS 21 Control of direct HC*: Control of DHW circuit: Active cooling mode: Control of mixed HC*: Control of direct pump HC*: Solar system control: with EXM** with EXM** with EXM** 8 Aquagor Terragor EVI W *HC = heating circuit **EXM = Extension module

Electronic control enable regulation of different heating systems Smart Web - remote control Large buildings in lot of cases need for different parts of the building different temperature regulation. Control units of heat pumps Gorenje enable regulation of different heating/cooling zones. Here are solutions for some cases. Regulation of different heating zones with control unit Siemens RVS 61 CASE 1: 3 HEATING ZONES WITH 3 MIXING HEATING CIRCUITS: 1st mixing heating circuit: controlled by Basic control unit RVS 61 2nd mixing heating circuit: Extension module Siemens AVS75.390/109 1 x NTC temperature sensor 3rd mixing heating circuit: Extension module RVS46.530/101 Regulation of different heating zones with control unit Siemens RVS 21 CASE 1: 3 HEATING ZONES WITH 3 MIXING HEATING CIRCUITS: 1st mixing heating circuit: Extension module Siemens AVS75.390/109 1 x NTC temperature sensor 2nd mixing heating circuit: Extension module Siemens AVS75.390/109 1 x NTC temperature sensor 3rd mixing heating circuit: Extension module RVS46.530/101 1 x NTC temperature sensor Room unit advanced/cooling/wired QAA75.611/701 CASE 2: 3 HEATING ZONES WITH 1 DIRECT AND 2 MIXING CIRCUITS: 1st direct heating circuit: The Smart Web application allows you to monitor your heat pump operation regardless of where you are. An internet connection can be used to connect the heat pump controllers to your personal computer or your cell phone. Thus, the system allows you to monitor the settings, to keep up to date with the device operating status, and to receive a warning in case of any failures. This makes remote control of your heating system convenient as well as cost and energy-effective due to constant control over equipment operation. Heat pump electronic control unit 1 x NTC temperature sensor Room unit advanced/cooling/wired QAA75.611/701 controlled by Basic control unit RVS 21 2nd mixixng heating circuit: USB Ethernet CASE 2: 3 HEATING ZONES WITH 1 DIRECT AND 2 MIXING CIRCUITS: 1st direct heating circuit: Extension module Siemens AVS75.390/109 1 x NTC temperature sensor OZW 164 controlled by Basic control unit RVS 61 3rd direct heating circuit: 1st mixing heating circuit: Extension module Siemens AVS75.390/109 controlled by Basic control unit RVS 61 1 x NTC temperature sensor 2nd mixing heating circuit: CASE 3: 3 ZONES WITH 3 DIRECT HEATING CIRCUITS: Extension module AVS75.390/109 1st direct heating circuit: 1 x NTC Temperature sensor controlled by Basic control unit RVS 21 CASE 3: 3 ZONES WITH 3 DIRECT HEATING CIRCUITS: 2nd direct heating circuit: Alarm email 1st and 2nd direct heating circuit: controlled by Basic control unit RVS 61 Extension module Siemens AVS75.390/10 1 x NTC temperature sensor Internet 3rd direct heating circuit: 3nd direct heating circuit: Extension module Siemens AVS75.390/109 Extension module Siemens AVS75.390/109 1 x NTC temperature sensor 1 x NTC temperature sensor 9

HEAT PUMPS AEROGOR COMPACT W AIR WATER AEROGOR COMPACT 25 54 W The main components and temperature sensors Compact outdoor unit Indoor unit Basic: DisplayBox W Display of control unit (HMI) Heating/Cooling mode HIGH TEMPERATURE OPERATION Advanced: ControlBox W main power switch display from control unit 1 x extension module AVS75.370 Heating/Cooling/DHW mode LEGEND MAIN ADVANTAGES Operating modes 10 Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 Type: Copeland scroll ZH High efficiency and quite scroll technology Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor Max. Outlet water temperature: 60 C (55 C up to ambient temperature -15 C) High efficiency Scroll ZH compressor (1 X) SWEP heat exchanger Tilting compact electro box with safety elements and control system 1 x EEV (electonic expansion valve) + 1 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part APS System Multi layer sound insulation Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST 10 meter LAN cable with RJ45 connectors 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package

HEAT PUMPS AEROGOR COMPACT EVI W AIR WATER AEROGOR COMPACT EVI 27 56 W The main components and temperature sensors Compact outdoor unit Indoor unit Basic: DisplayBox W Display of control unit (HMI) Heating/Cooling mode HIGH TEMPERATURE OPERATION Advanced: ControlBox W main power switch display from control unit 1 x extension module AVS75.370 Heating/Cooling/DHW mode LEGEND MAIN ADVANTAGES Operating modes Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 Type: Copeland scroll ZH EVI Extreme good performances Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor Max. Outlet water temperature: 65 C (up to ambient temperature -20 C) High efficiency Scroll EVI compressor (1 X) SWEP heat exchanger Tilting compact electro box with safety elements and control system 1 x EEV (electonic expansion valve) + 1 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part APS System Multi layer sound insulation Serial integrated circulating pump Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST 10 meter LAN cable with RJ45 connectors 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package 11

HEAT PUMPS AEROGOR SPLIT AW W AIR WATER AEROGOR SPLIT AW 25 54 W The main components and temperature sensors Compact outdoor unit Indoor unit HIGH TEMPERATURE OPERATION LEGEND MAIN ADVANTAGES Operating modes 12 Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 Type: Copeland scroll ZH High efficiency and quite scroll technology Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor Max. Outlet water temperature: 60 C (55 C up to ambient temperature -15 C) High efficiency Scroll ZH compressor (1 X) SWEP heat exchanger Tilting compact electro box with safety elements and control system 1 x EEV (electonic expansion valve) + 1 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part APS System Multi layer sound insulation Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package

HEAT PUMPS AEROGOR SPLIT AW EVI W AIR WATER AEROGOR SPLIT AW EVI 20 55 W The main components and temperature sensors Compact outdoor unit Indoor unit HIGH TEMPERATURE OPERATION LEGEND MAIN ADVANTAGES Operating modes Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 Type: Copeland scroll ZH EVI Extreme good performances Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor Max. Outlet water temperature: 65 C (up to ambient temperature -20 C) High efficiency Scroll EVI compressor (1 X) SWEP heat exchanger Tilting compact electro box with safety elements and control system 1 x EEV (electonic expansion valve) + 1 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part APS System Multi layer sound insulation Serial integrated circulating pump Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package 13

HEAT PUMPS AEROGOR SPLIT HD W AIR WATER AEROGOR SPLIT HD 107 W The main components and temperature sensors Outdoor unit 1 Outdoor unit 2 Indoor unit (2 x compressors) HIGH TEMPERATURE OPERATION LEGEND MAIN ADVANTAGES Operating modes 14 Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 and 2 Type: Copeland scroll ZH High efficiency and quite scroll technology Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor Max. Outlet water temperature: 60 C (up to ambient temperature -15 C) 2 X High efficiency Scroll ZH compressor SWEP heat exchanger Tilting compact electro box with safety elements and control system 2 x EEV (electonic expansion valve) + 2 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part APS System Multi layer sound insulation Without serial integrated circulating pump Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package

HEAT PUMPS AEROGOR SPLIT HD EVI W AIR WATER AEROGOR SPLIT HD EVI 109 W The main components and temperature sensors Outdoor unit 1 Outdoor unit 2 Indoor unit (2 x compressors) HIGH TEMPERATURE OPERATION LEGEND MAIN ADVANTAGES Operating modes Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 and 2 Type: Copeland scroll ZH EVI Extreme good performances Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor Max. Outlet water temperature: 65 C (up to ambient temperature -20 C) 2 X High efficiency Scroll EVI compressor SWEP heat exchanger Tilting compact electro box with safety elements and control system 2 x EEV (electonic expansion valve) + 2 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part APS System Multi layer sound insulation Without serial integrated circulating pump Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package 15

HEAT PUMPS AEROGOR SPLIT HD EVI W AIR WATER AEROGOR SPLIT HD EVI 163 W The main components and temperature sensors Outdoor unit 1 Outdoor unit 2 Outdoor unit 3 Indoor unit (3 x compressors) HIGH TEMPERATURE OPERATION LEGEND MAIN ADVANTAGES Operating modes 16 Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressors 1, 2, 3 Type: Copeland scroll ZH EVI Extreme good performances Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor Max. Outlet water temperature: 65 C (up to ambient temperature -20 C) 3 X High efficiency Scroll EVI compressor SWEP heat exchanger Tilting compact electro box with safety elements and control system 3 x EEV (electonic expansion valve) + 3 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part APS System Multi layer sound insulation Without serial integrated circulating pump Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package

17

GEOTHERMAL HEAT PUMPS BRINE-WATER AND WATER-WATER HEAT PUMPS AQUAGOR TERRAGOR W The main components and temperature sensors Geothermal heat pumps operate in two levels/cycles: Two compressors operate in a cascade system to allow the adjustment of heating power to the heating requirements of the building in different periods of the heating season. HIGH TEMPERATURE OPERATION ACCESSORIES LIST 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package MAIN ADVANTAGES Max. Outlet water temperature: 60 C Passive cooling mode Reverse active cooling optional 2 X High efficiency Scroll ZH compressor SWEP heat exchanger Tilting compact electro box with safety elements and control system 1 x EEV (electonic expansion valve) Large surface condenser and evaporator plate heat exchanger Robust and solid refrigeration cycle designed for highest stability and long term high performance Operating modes 18 LEGEND Q8: circulating pump on source side Q9: circulating pump on the secondary side (condenser) B91: inlet temperature sensor of source side (evaporator) B92: outlet temperature sensor of source side (evaporator) K1 / E11: compressor 1 K2 / E12: compressor 2 B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Multi layer sound insulation Without serial integrated circulating pump Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE/PASIVE COOLING

HEAT PUMPS AQUAGOR TERRAGOR EVI W The main components and temperature sensors Geothermal heat pumps operate in two levels/cycles: Two compressors operate in a cascade system to allow the adjustment of heating power to the heating requirements of the building in different periods of the heating season. HIGH TEMPERATURE OPERATION ACCESSORIES LIST 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package MAIN ADVANTAGES Max. Outlet water temperature: 65 C Passive cooling mode Reverse active cooling optional 2 X High efficiency Scroll ZH compressor SWEP heat exchanger Tilting compact electro box with safety elements and control system 2 x EEV (electonic expansion valve) Large surface condenser and evaporator plate heat exchanger Robust and solid refrigeration cycle designed for highest stability and long term high performance Operating modes LEGEND Q8: circulating pump on source side Q9: circulating pump on the secondary side (condenser) B91: inlet temperature sensor of source side (evaporator) B92: outlet temperature sensor of source side (evaporator) K1 / E11: compressor 1 K2 / E12: compressor 2 B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Multi layer sound insulation Without serial integrated circulating pump Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE/PASIVE COOLING 19

OPERATING RANGE FOR AEROGOR COMPACT W AND AEROGOR COMPACT EVI W 70 OPERATING RANGE OF: AEROGOR COMPACT EVI W AEROGOR SPLIT HD EVI W OUTLET WATER TEMPERATURE [ C] 65 60 55 50 45 40 35 30 25-25 -20-15 -10-5 0 5 10 15 20 25 30 35 40 45 OUTSIDE AMBIENT TEMPERATURE [ C] Optimum Maximum 70 OPERATING RANGE OF: AEROGOR COMPACT W AEROGOR SPLIT AW W, AEROGOR SPLIT HD W OUTLET WATER TEMPERATURE [ C] 65 60 55 50 45 40 35 30 25-25 -20-15 -10-5 0 5 10 15 20 25 30 35 40 45 OUTSIDE AMBIENT TEMPERATURE [ C] 20

OPERATING RANGE FOR AQUAGOR TERRAGOR W AND AQUAGOR TERRAGOR EVI W OPERATING RANGE TERRAGOR W OPERATING RANGE TERRAGOR EVI W 70 70 OUTLET WATER TEMPERATURE [ C] 65 60 55 50 45 40 35 30 OUTLET WATER TEMPERATURE [ C] 65 60 55 50 45 40 35 30 25-10 -5 0 5 10 15 20 25 30 25-10 -5 0 5 10 15 20 25 30 SOURCE (BRINE) TEMPERATURE [ C] SOURCE (BRINE) TEMPERATURE [ C] OPERATING RANGE AQUAGOR W OPERATING RANGE AQUAGOR EVI W 70 70 OUTLET WATER TEMPERATURE [ C] 65 60 55 50 45 40 35 30 OUTLET WATER TEMPERATURE [ C] 65 60 55 50 45 40 35 30 25-10 -5 0 5 10 15 20 25 30 25-10 -5 0 5 10 15 20 25 30 SOURCE (WATER) TEMPERATURE [ C] SOURCE (WATER) TEMPERATURE [ C] 21

TABLE OF RECOMMENDED CIRCULATING PUMPS FOR AQUAGOR TERRAGOR W AND AQUAGOR TERRAGOR EVI W Model name Primary side source side (brine)* Secondary side heating side Terragor 28 W Aquagor 37 W Terragor 38 W Aquagor 50 W Terragor 43 W Aquagor 59 W Terragor 52 W Aquagor 67 W Terragor 56 W Aquagor 78 W Terragor 65 W Aquagor 89 W Terragor 70 W Aquagor 100 W Terragor 83 W Aquagor 115 W Terragor EVI 67 W Aquagor EVI 87 W Terragor EVI 81 W Aquagor EVI 105 W Terragor EVI 98 W Aquagor EVI 126 W WILO Stratos 40/1-8 WILO Stratos 30/1-8 WILO Stratos 50/1-8 WILO Stratos 50/1-8 WILO Stratos 50/1-8 WILO Stratos 50/1-8 WILO Stratos 50/1-9 WILO Stratos 50/1-8 WILO Stratos 50/1-9 WILO Stratos 50/1-8 WILO Stratos 65/1-12 WILO Stratos 65/1-12 WILO Stratos 80/1-12 WILO Stratos 80/1-12 WILO Stratos 80/1-12 WILO Stratos 80/1-12 WILO Stratos 65/1-12 WILO Stratos 65/1-12 WILO Stratos 80/1-12 WILO Stratos 80/1-12 WILO Stratos 80/1-12 WILO Stratos 80/1-12 22 * Valid only for systems brine-water. On the primary (source) side of heat pump waterwater must be built-in submersible pump for the underground water. Type of submersible pump is depend on the deepness of borehole of and the distance (pipe length) from borehole to the heat pump.

Split system air / water : outdoor unit + indoor unit AEROGOR SPLIT HD W and SPLIT EVI HD W Model name Aerogor Split HD 107 W 2 x outdoor unit Aerogor Split HD EVI 109 W 2 x outdoor unit Aerogor Split HD EVI 163 W 3 x outdoor unit Operating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Code number 2 x 468624 / 477670 2 x 468624 / 477701 3 x 468624 / 477702 Connection between outdoor and indoor unit Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Heating capacity A7/W35 kw 106,60 109,04 163,33 COP A7/W35 / 4,77 4,91 4,91 Heating capacity A7/W45 kw 102,37 110,31 165,24 COP A7/W45 / 3,79 4,04 4,04 Heating capacity A7/W55 kw 96,66 112,34 168,28 COP A7/W55 / 3,00 3,31 3,31 Heating capacity A7/W65 kw / 112,76 168,91 COP A7/W65 / / 2,72 2,72 Heating capacity A2/W35 kw 86,73 93,46 140,00 COP A2/W35 / 3,70 3,80 3,80 Heating capacity A2/W45 kw 83,37 94,14 141,02 COP A2/W45 / 3,02 3,12 3,12 Heating capacity A2/W55 kw 79,21 95,24 142,66 COP A2/W55 / 2,39 2,56 2,56 Heating capacity A2/W65 kw / 96,25 144,18 COP A2/W65 / / 2,10 2,10 Heating capacity A-2/W35 kw 72,88 86,49 129,56 COP A-2/W35 / 3,32 3,44 3,44 Heating capacity A-7/W35 kw 61,22 80,59 120,72 COP A-7/W35 / 3,06 3,09 3,09 Heating capacity A-15/W35 kw 49,81 67,05 100,43 COP A-15/W35 / 2,45 2,59 2,59 Maximum outlet water temperature C 60 65 65 Operating range C -20 C to +40 C -20 C to +40 C -20 C to +40 C Active cooling / yes yes yes Cooling capacity - reversible operation A35/W12 kw 68,4 73,6 110,4 Power input - reversible operation A35/W12 kw 31 33,4 50,1 ERR / 2,2 2,2 2,2 Neto weight - outdoor unit kg 410 450 740 Neto weight - indoor unit kg 2 x 185 2 x 185 3 x 185 Dimensions of outdoor unit (W x D x H) mm 1050 x 1700 x 1530 1050 x 1700 x 1530 1050 x 1700 x 1530 Dimensions of indoor unit (W x D x H) mm 1233 x 1371 x 1300 1233 x 1371 x 1300 1233 x 1371 x 1300 Voltage V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz Noise emissions [5m] - indoor unit db 59 59 61 Noise emissions [8m] - outdoor unit db 69 69 73 Connecting dimensions primary side mm 2 x (22 mm / 35 mm) 2 x (22 mm / 35 mm) 3 x (22 mm / 35 mm) Connecting dimensions secondary side 1 1/2 1 1/2 1 1/2 Type of screw thread - outdoor unit / inner inner inner Air flow - primary side m 3 /h 2 x 14.067 2 x 14.067 3 x 14.067 Nominal water flow - secondary side m 3 /h 2 x 5,1 2 x 5,7 3 x 5,7 Pressure drop - primary side kpa 2 x 0,061 2 x 0,061 3 x 0,061 Pressure drop - secondary side kpa max 20 max 20 max 20 Recommended temperature difference (flow / return) K 7 7 7 Main connection cable dimension mm 2 5 x 25 mm 2 5 x 25 mm 2 5x25 mm 2 Power connection (indoor - outdoor unit) mm 2 2 x 3 x 1,5 mm 2 2 x 3 x 1,5 mm 2 3 x 3 x 1,5 mm 2 Electrical connection cable between indoor - outdoor unit [sheathed] mm 2 2 x 10 x 0,75 mm 2 2 x 10 x 0,75 mm 2 3 x 10 x 0,75 mm 2 Fuse / Type A 63 A / C 80 A / C 100 A / C Current nominal A 2 x 18 2 x 20,8 3 x 20,8 Current maximal A 2 x 36,3 2 x 35,9 3 x 35,9 Softstart / 2 x MCD201 2 x MCD201 3 x MCD201 Starting current A 2 x 47,52 2 x 54,91 3 x 54,91 Type of refrigerant / R407C R407C R407C Volume of refrigerant kg 2 x 12,5 2 x 14 3 x 14 Type of expansion valve / EEV EEV EEV Type of compressor / Copeland SCROLL ZH Copeland SCROLL EVI Copeland SCROLL EVI Number of compressors / 2 2 3 Circulating pumps - return flow / no no no Fan type / Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Back-up electrical flow heater / no no no 3-way diverting valve / no no no Serial integrated controller / Siemens RVS 21 Siemens RVS 21 Siemens RVS 21 Control of mixing heating cirquit / with extension module with extension module with extension module Control of direct heating cirquit / with extension module with extension module with extension module Solar system control / with extension module with extension module with extension module ModBus / with extension module with extension module with extension module WebControl / with WebServer module with WebServer module with WebServer module Option for cascade system / (with LPB module) (with LPB module) (with LPB module) 23

24 System air / water - Compact outdoor unit AEROGOR COMPACT W + DisplayBox W / ControlBox W Model name Basic solution: Aerogor Compact 25 W + DisplayBox W Aerogor Compact 36 W + DisplayBox W Aerogor Compact 44 W + DisplayBox W Aerogor Compact 54 W + DisplayBox W Aerogor Compact EVI 27 W + DisplayBox W Operating modes Heating / Cooling Heating / Cooling Heating / Cooling Heating / Cooling Heating / Cooling Model name Advanced solution: Aerogor Compact 25 W + ControlBox W Aerogor Compact 36 W + ControlBox W Aerogor Compact 44 W + ControlBox W Aerogor Compact 54 W + ControlBox W Aerogor Compact EVI 27 W + ControlBox W Operating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Code numbers - Aerogor Compact W 432865 452269 452270 452291 452292 Code numbers - DisplayBox W 477970 477970 477970 477970 477970 Code numbers - ControlBox W 452714 452714 452714 452714 452714 Connection between outdoor unit and heating system water pipe connection water pipe connection water pipe connection water pipe connection water pipe connection Heating capacity A7/W35 kw 25,31 35,77 44,41 53,83 25,90 COP A7/W35 / 4,64 4,77 4,64 4,77 4,79 Heating capacity A7/W45 kw 24,30 34,35 42,65 51,70 26,20 COP A7/W45 / 3,69 3,79 3,69 3,79 3,93 Heating capacity A7/W55 kw 22,95 32,43 40,27 48,82 26,68 COP A7/W55 / 2,92 3,00 2,92 3,00 3,23 Heating capacity A7/W65 kw / / / / 26,78 COP A7/W65 / / / / / 2,65 Heating capacity A2/W35 kw 20,59 29,10 36,13 43,80 22,20 COP A2/W35 / 3,60 3,70 3,60 3,70 3,70 Heating capacity A2/W45 kw 19,79 27,97 34,73 42,10 22,36 COP A2/W45 / 2,93 3,70 2,93 3,70 3,04 Heating capacity A2/W55 kw 18,81 26,58 33,00 40,00 22,62 COP A2/W55 / 2,33 2,39 2,33 2,39 2,49 Heating capacity A2/W65 kw / / / / 22,86 COP A2/W65 / / / / / 2,05 Heating capacity A-2/W35 kw 17,30 24,45 30,36 36,80 20,54 COP A-2/W35 / 3,23 3,32 3,23 3,32 3,35 Heating capacity A-7/W35 kw 14,53 20,45 25,50 30,92 19,14 COP A-7/W35 / 2,98 3,06 2,98 3,06 3,01 Heating capacity A-15/W35 kw 11,82 16,71 20,75 25,15 15,93 COP A-15/W35 / 2,39 2,45 2,39 2,45 2,52 Maximum outlet water temperature C 60 60 60 60 65 Operating range C -20 C to +40 C -20 C to +40 C -20 C to +40 C -20 C to +40 C -20 C to +40 C Active cooling / yes yes yes yes yes Cooling capacity - reversible operation A35/W12 kw 16,50 23,30 28,20 34,20 18,60 Power input - reversible operation A35/W12 kw 7,10 10,10 12,80 15,50 8,00 ERR / 2,3 2,3 2,2 2,2 2,3 Neto weight - outdoor unit kg 290 350 350 350 350 Neto weight - indoor unit kg 27 27 27 27 27 Dimensions of outdoor unit (W x D x H) mm 1345 x 930 x 943 1776 x 1371 x 1246 1776 x 1371 x 1246 1776 x 1371 x 1246 1776 x 1371 x 1246 Dimensions of indoor unit (W x D x H) mm 535 x 350 x 590 535 x 350 x 590 535 x 350 x 590 535 x 350 x 590 535 x 350 x 590 Voltage V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz Noise emissions [5m] - indoor unit db 0 0 0 0 0 Noise emissions [8m] - outdoor unit db 58 61 61 66 58 Connecting dimensions secondary side 1 1/4 1 1/2 1 1/2 1 1/2 1 1/4 Type of screw thread - outdoor unit / inner inner inner inner inner Air flow - primary side m 3 /h 4959 5800 10000 14067 10300 Nominal water flow - secondary side m 3 /h 3,20 4,60 4,10 5,10 3,90 Pressure drop - primary side kpa 0,05 0,057 0,043 0,061 0,057 Pressure drop - secondary side kpa max 20 max 20 max 20 max 20 max 20 Recommended temperature difference (flow / return) K 5 5 7 7 5 Main connection cable dimension mm 2 5 x 6 mm 2 5 x 6 mm 2 5 x 6 mm 2 5 x 10 mm 2 5 x 6 mm 2 Power connection (indoor - outdoor unit) mm 2 5 x 6 mm 2 5 x 6 mm 2 5 x 6 mm 2 5 x 10 mm 2 5 x 6 mm 2 Electrical connection cable between indoor - outdoor unit [sheathed] mm 2 UTP & 5 x 0,75 mm 2 UTP & 5 x 0,75 mm 2 UTP & 5 x 0,75 mm 2 UTP & 5 x 0,75 mm 2 UTP & 5 x 0,75 mm 2 Fuse / Type A 32 A / C 25 A / C 32 A / C 40 A / C 32 A / C Current nominal A 11,60 11,80 16,80 18,00 11,80 Current maximal A 27,90 23,90 28,90 36,30 29,90 Softstart / MCI 25 MCI 25 MCD201 MCD201 MCI 25 Starting current A 30,62 31,15 44,35 47,52 31,15 Type of refrigerant / R407C R407C R407C R407C R407C Volume of refrigerant kg 7,00 7,30 12,00 12,50 8,20 Type of expansion valve / EEV EEV EEV EEV EEV Type of compressor / Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL EVI Number of compressors / 1 1 1 1 1 Circulating pumps - return flow / yes yes yes yes yes Fan type / Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Back-up electrical flow heater / no no no no no 3-way diverting valve / no no no no no Serial integrated controller / Siemens RVS 21 Siemens RVS 21 Siemens RVS 21 Siemens RVS 21 Siemens RVS 21 Control of mixing heating cirquit / with extension module with extension module with extension module with extension module with extension module Control of direct heating cirquit / yes yes yes yes yes Solar system control / with extension module with extension module with extension module with extension module with extension module ModBus / with extension module with extension module with extension module with extension module with extension module WebControl / with WebServer module with WebServer module with WebServer module with WebServer module with WebServer module Option for cascade system / (with LPB module) (with LPB module) (with LPB module) (with LPB module) (with LPB module)

System air / water - Compact outdoor unit AEROGOR COMPACT W + DisplayBox W / ControlBox W Model name Basic solution: Aerogor Compact EVI 37 W + DisplayBox W Aerogor Compact EVI 48 W + DisplayBox W Aerogor Compact EVI 56 W + DisplayBox W Operating modes Heating / Cooling Heating / Cooling Heating / Cooling Model name Advanced solution: Aerogor Compact EVI 37 W + ControlBox W Aerogor Compact EVI 48 W + ControlBox W Aerogor Compact EVI 56 W + ControlBox W Operating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Code numbers - Aerogor Compact W 452293 452294 452296 Code numbers - DisplayBox W 477970 477970 477970 Code numbers - ControlBox W 452714 452714 452714 Connection between outdoor unit and heating system water pipe connection water pipe connection water pipe connection Heating capacity A7/W35 kw 35,58 47,13 54,95 COP A7/W35 / 4,79 4,91 4,91 Heating capacity A7/W45 kw 36,00 47,68 55,59 COP A7/W45 / 3,93 4,04 4,04 Heating capacity A7/W55 kw 36,66 48,56 56,61 COP A7/W55 / 3,23 3,31 3,31 Heating capacity A7/W65 kw 36,80 48,74 56,83 COP A7/W65 / 2,65 2,72 2,72 Heating capacity A2/W35 kw 30,50 40,40 47,10 COP A2/W35 / 3,70 3,80 3,80 Heating capacity A2/W45 kw 30,72 40,69 47,44 COP A2/W45 / 30,40 3,12 3,12 Heating capacity A2/W55 kw 31,08 41,17 48,00 COP A2/W55 / 2,49 2,56 2,56 Heating capacity A2/W65 kw 31,41 41,61 48,51 COP A2/W65 / 2,05 2,10 2,10 Heating capacity A-2/W35 kw 28,23 37,39 43,59 COP A-2/W35 / 3,35 3,44 3,44 Heating capacity A-7/W35 kw 26,30 34,84 40,62 COP A-7/W35 / 3,01 3,09 3,09 Heating capacity A-15/W35 kw 21,88 28,98 33,79 COP A-15/W35 / 2,52 2,59 2,59 Maximum outlet water temperature C 65 65 65 Operating range C -20 C to +40 C -20 C to +40 C -20 C to +40 C Active cooling / yes yes yes Cooling capacity - reversible operation A35/W12 kw 23,90 31,80 36,80 Power input - reversible operation A35/W12 kw 10,80 13,80 16,70 ERR / 2,2 2,3 2,2 Neto weight - outdoor unit kg 380 380 390 Neto weight - indoor unit kg 27 27 27 Dimensions of outdoor unit (W x D x H) mm 1776 x 1371 x 1246 1776 x 1371 x 1246 1776 x 1371 x 1246 Dimensions of indoor unit (W x D x H) mm 535 x 350 x 590 535 x 350 x 590 535 x 350 x 590 Voltage V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz Noise emissions [5m] - indoor unit db 0 0 0 Noise emissions [8m] - outdoor unit db 61 66 66 Connecting dimensions secondary side 1 1/2 1 1/2 1 1/2 Type of screw thread - outdoor unit / inner inner inner Air flow - primary side m 3 /h 10300 14067 14067 Nominal water flow - secondary side m 3 /h 5,20 4,80 5,70 Pressure drop - primary side kpa 0,075 0,043 0,061 Pressure drop - secondary side kpa max 20 max 20 max 20 Recommended temperature difference (flow / return) K 5 7 7 Main connection cable dimension mm 2 5 x 6 mm 2 5 x 10 mm 2 5 x 10 mm 2 Power connection (indoor - outdoor unit) mm 2 5 x 6 mm 2 5 x 10 mm 2 5 x 10 mm 2 Electrical connection cable between indoor - outdoor unit [sheathed] mm 2 UTP & 5 x 0,75 mm 2 UTP & 5 x 0,75 mm 2 UTP & 5 x 0,75 mm 2 Fuse / Type A 32 A / C 32 A / C 40 A / C Current nominal A 14,60 16,80 20,80 Current maximal A 27,10 30,60 35,90 Softstart / MCI 25 MCD201 MCD201 Starting current A 38,54 44,35 51,91 Type of refrigerant / R407C R407C R407C Volume of refrigerant kg 9,50 13,00 14,00 Type of expansion valve / EEV EEV EEV Type of compressor / Copeland SCROLL EVI Copeland SCROLL EVI Copeland SCROLL EVI Number of compressors / 1 1 1 Circulating pumps - return flow / yes yes yes Fan type / Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Back-up electrical flow heater / no no no 3-way diverting valve / no no no Serial integrated controller / Siemens RVS 21 Siemens RVS 21 Siemens RVS 21 Control of mixing heating cirquit / with extension module with extension module with extension module Control of direct heating cirquit / yes yes yes Solar system control / with extension module with extension module with extension module ModBus / with extension module with extension module with extension module WebControl / with WebServer module with WebServer module with WebServer module Option for cascade system / (with LPB module) (with LPB module) (with LPB module) 25

26 Split system air / water : outdoor unit + indoor unit AEROGOR SPLIT AW W and SPLIT AW EVI W Model name Aerogor Split AW 25 W Aerogor Split AW 36 W Aerogor Split AW 44 W Aerogor Split AW 54 W Aerogor Split AW 47 EVI W Aerogor Split AW 55 EVI W Operating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Code number 461562 / 455397 453966 / 477703 468624 / 477704 468624 / 477705 468624 / 477706 468624 / 468630 Connection between outdoor and indoor unit Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Heating capacity A7/W35 kw 25,31 35,77 44,41 53,83 47,13 54,95 COP A7/W35 / 4,64 4,77 4,64 4,77 4,91 4,91 Heating capacity A7/W45 kw 24,30 34,35 42,65 51,70 47,68 55,59 COP A7/W45 / 3,69 3,79 3,69 3,79 4,04 4,04 Heating capacity A7/W55 kw 22,95 32,43 40,27 48,83 48,56 56,61 COP A7/W55 / 2,92 3,00 2,92 3,00 3,31 3,31 Heating capacity A7/W65 kw / / / / 48,74 56,83 COP A7/W65 / / / / / 2,72 2,72 Heating capacity A2/W35 kw 20,59 29,10 36,13 43,80 40,40 47,10 COP A2/W35 / 3,60 3,70 3,60 3,70 3,80 3,80 Heating capacity A2/W45 kw 19,79 27,97 34,73 42,10 40,69 47,44 COP A2/W45 / 2,93 3,02 2,93 3,02 3,12 3,12 Heating capacity A2/W55 kw 18,81 26,58 33,00 40,00 41,17 48,00 COP A2/W55 / 2,33 2,39 2,33 2,39 2,56 2,56 Heating capacity A2/W65 kw / / / / 41,61 48,51 COP A2/W65 / / / / / 2,10 2,10 Heating capacity A-2/W35 kw 17,30 24,45 30,36 36,80 37,39 43,59 COP A-2/W35 / 3,23 3,32 3,23 3,32 3,44 3,44 Heating capacity A-7/W35 kw 14,53 20,54 25,50 30,92 34,84 40,62 COP A-7/W35 / 2,98 3,06 2,98 3,06 3,09 3,09 Heating capacity A-15/W35 kw 11,82 16,71 20,75 25,15 28,98 33,79 COP A-15/W35 / 2,39 2,45 2,39 2,45 2,59 2,59 Maximum outlet water temperature C 60 60 60 60 65 65 Operating range C -20 C to +40 C -20 C to +40 C -20 C to +40 C -20 C to +40 C -20 C to +40 C -20 C to +40 C Active cooling / yes yes yes yes yes yes Cooling capacity - reversible operation A35/W12 kw 16,5 23,3 28,2 34,2 31,8 36,8 Power input - reversible operation A35/W12 kw 7,1 10,1 12,8 15,5 13,8 16,7 ERR / 2,3 2,3 2,2 2,2 2,3 2,2 Neto weight - outdoor unit kg 149 170 175 198 210 210 Neto weight - indoor unit kg 142 155 185 185 185 185 Dimensions of outdoor unit (W x D x H) mm 800 x 580 x 1105 800 x 580 x 1105 800 x 785 x 1105 800 x 785 x 1105 800 x 785 x 1105 800 x 785 x 1105 Dimensions of indoor unit (W x D x H) mm 800 x 900 x 775 1200 x 1290 x 1045 1200 x 1290 x 1045 1200 x 1290 x 1045 1200 x 1290 x 1045 1200 x 1290 x 1045 Voltage V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz Noise emissions [5m] - indoor unit db 52 54 55 57 55 57 Noise emissions [8m] - outdoor unit db 54 59 59 64 64 64 Connecting dimensions primary side mm 16 mm / 28 mm 18 mm / 28 mm 18 mm / 35 mm 22 mm / 35 mm 18mm / 35mm 22 mm / 35 mm Connecting dimensions secondary side 1 1/4 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 Type of screw thread - outdoor unit / inner inner inner inner inner inner Air flow - primary side m 3 /h 4959 5800 10.000 14.067 14067 14067 Nominal water flow - secondary side m 3 /h 3,2 4,6 4,1 5,1 4,8 5,7 Pressure drop - primary side kpa 0,05 0,057 0,043 0,061 0,043 0,061 Pressure drop - secondary side kpa max 20 max 20 max 20 max 20 max 20 max 20 Recommended temperature difference (flow / return) K 5 5 7 7 7 7 Main connection cable dimension mm 2 5 x 6 mm 2 5 x 6 mm 2 5 x 6 mm 2 5 x 10 mm 2 5 x 10 mm 2 5 x 10 mm 2 Power connection (indoor - outdoor unit) mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 Electrical connection cable between indoor - outdoor unit [sheathed] mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 Fuse / Type A 32 A / C 25 A / C 32 A / C 40 A / C 32 A / C 40 A / C Current nominal A 11,6 11,8 16,8 18 16,8 20,8 Current maximal A 27,9 23,9 28,9 36,3 30,6 35,9 Softstart / MCI 25 MCI 25 MCD201 MCD201 MCD201 MCD201 Starting current A 30,62 31,15 44,35 47,52 44,35 54,91 Type of refrigerant / R407C R407C R407C R407C R407C R407C Volume of refrigerant kg 7 7,3 12 12,5 13 14 Type of expansion valve / EEV EEV EEV EEV EEV EEV Type of compressor / Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL EVI Copeland SCROLL EVI Number of compressors / 1 1 1 1 1 1 Circulating pumps - return flow / yes yes yes yes yes yes Fan type / Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Back-up electrical flow heater / no no no no no no 3-way diverting valve / no no no no no no Serial integrated controller / Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Control of mixing heating cirquit / yes yes yes yes yes yes Control of direct heating cirquit / yes yes yes yes yes yes Solar system control / yes yes yes yes yes yes ModBus / with extension module with extension module with extension module with extension module with extension module with extension module WebControl / z Web modulom z Web modulom z Web modulom z Web modulom with WebServer module with WebServer module Option for cascade system / (with LPB module) (with LPB module) (with LPB module) (with LPB module) (with LPB module) (with LPB module)

Split system air / water : outdoor unit + indoor unit AEROGOR SPLIT AW W and SPLIT AW EVI W Model name Aerogor Split AW 20 EVI W Aerogor Split AW 26 EVI W Aerogor Split AW 36 EVI W Aerogor Split AW 47 EVI W Aerogor Split AW 55 EVI W Operating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Code number 461562 / 461561 453966 / 472083 453966 / 453965 468624 / 477706 468624 / 468630 Connection between outdoor and indoor unit Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Heating capacity A7/W35 kw 19,95 25,90 35,58 47,13 54,95 COP A7/W35 / 4,91 4,79 4,79 4,91 4,91 Heating capacity A7/W45 kw 20,18 26,20 36,00 47,68 55,59 COP A7/W45 / 4,04 3,93 3,93 4,04 4,04 Heating capacity A7/W55 kw 20,55 26,68 36,66 48,56 56,61 COP A7/W55 / 3,31 3,23 3,23 3,31 3,31 Heating capacity A7/W65 kw 20,63 26,78 36,80 48,74 56,83 COP A7/W65 / 2,72 2,65 2,65 2,72 2,72 Heating capacity A2/W35 kw 17,10 22,20 30,50 40,40 47,10 COP A2/W35 / 3,80 3,70 3,70 3,80 3,80 Heating capacity A2/W45 kw 17,22 22,36 30,72 40,69 47,44 COP A2/W45 / 3,12 3,04 3,04 3,12 3,12 Heating capacity A2/W55 kw 17,43 22,62 31,08 41,17 48,00 COP A2/W55 / 2,56 2,49 2,49 2,56 2,56 Heating capacity A2/W65 kw 17,61 22,86 31,41 41,61 48,51 COP A2/W65 / 2,10 2,05 2,05 2,10 2,10 Heating capacity A-2/W35 kw 15,82 20,54 28,23 37,39 43,59 COP A-2/W35 / 3,44 3,35 3,35 3,44 3,44 Heating capacity A-7/W35 kw 14,75 19,14 26,30 34,84 40,62 COP A-7/W35 / 3,09 3,01 3,01 3,09 3,09 Heating capacity A-15/W35 kw 12,27 15,93 21,88 28,98 33,79 COP A-15/W35 / 2,59 2,52 2,52 2,59 2,59 Maximum outlet water temperature C 65 65 65 65 65 Operating range C -20 C to +40 C -20 C to +40 C -20 C to +40 C -20 C to +40 C -20 C to +40 C Active cooling / yes yes yes yes yes Cooling capacity - reversible operation A35/W12 kw 14,6 18,6 23,9 31,8 36,8 Power input - reversible operation A35/W12 kw 6,6 8 10,8 13,8 16,7 ERR / 2,2 2,3 2,2 2,3 2,2 Neto weight - outdoor unit kg 145 185 195 210 210 Neto weight - indoor unit kg 142 155 155 185 185 Dimensions of outdoor unit (W x D x H) mm 600 x 580 x 1105 800 x 580 x 1105 800 x 580 x 1105 800 x 785 x 1105 800 x 785 x 1105 Dimensions of indoor unit (W x D x H) mm 800 x 900 x 775 1200 x 1290 x 1045 1200 x 1290 x 1045 1200 x 1290 x 1045 1200 x 1290 x 1045 Voltage V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz Noise emissions [5m] - indoor unit db 48 49 53 55 57 Noise emissions [8m] - outdoor unit db 54 59 59 64 64 Connecting dimensions primary side mm 12 mm / 22 mm 16 mm / 28 mm 16mm / 28mm 18mm / 35mm 22 mm / 35 mm Connecting dimensions secondary side 1 1/4 1 1/4 1 1/2 1 1/2 1 1/2 Type of screw thread - outdoor unit / inner inner inner inner inner Air flow - primary side m 3 /h 4959 10.300 10.300 14067 14067 Nominal water flow - secondary side m 3 /h 3 3,9 5,2 4,8 5,7 Pressure drop - primary side kpa 0,05 0,057 0,075 0,043 0,061 Pressure drop - secondary side kpa max 20 max 20 max 20 max 20 max 20 Recommended temperature difference (flow / return) K 5 5 5 7 7 Main connection cable dimension mm 2 5 x 4 mm 2 5 x 6 mm 2 5 x 6 mm 2 5 x 10 mm 2 5 x 10 mm 2 Power connection (indoor - outdoor unit) mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 Electrical connection cable between indoor - outdoor unit [sheathed] mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 Fuse / Type A 25 A / C 32 A / C 32 A / C 32 A / C 40 A / C Current nominal A 9,7 11,8 14,6 16,8 20,8 Current maximal A 25,5 29,9 27,1 30,6 35,9 Softstart / MCI 15 MCI 25 MCI 25 MCD201 MCD201 Starting current A 25,6 31,15 38,54 44,35 54,91 Type of refrigerant / R407C R407C R407C R407C R407C Volume of refrigerant kg 5,9 8,2 9,5 13 14 Type of expansion valve / 4.5 (12/16) EEV EEV EEV EEV Type of compressor / Copeland SCROLL EVI Copeland SCROLL EVI Copeland SCROLL EVI Copeland SCROLL EVI Copeland SCROLL EVI Number of compressors / 1 1 1 1 1 Circulating pumps - return flow / yes yes yes yes yes Fan type / Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Back-up electrical flow heater / yes, 3 x 2kW no no no no 3-way diverting valve / yes no no no no Serial integrated controller / Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Control of mixing heating cirquit / yes yes yes yes yes Control of direct heating cirquit / yes yes yes yes yes Solar system control / yes yes yes yes yes ModBus / with extension module with extension module with extension module with extension module with extension module WebControl / with WebServer module with WebServer module with WebServer module with WebServer module with WebServer module Option for cascade system / (with LPB module) (with LPB module) (with LPB module) (with LPB module) (with LPB module) 27